E-Tender For Procurement Of Some Consumable Items For Two Years From The Date Of Award Of Contract (Aoc) , Biopsy Gun, Trus Biopsy Needle(Core Needle Biopsy Gun)- Tissue Biopsy Needle, 18 G , 20/25 Cm, Biopsy Needle/ 14G (10Cm,16Cm) / 16G (16Cm) / 14G (10Cm,16Cm,20Cm) , Biopsy Gun, Kidney Biopsy Gun 10X16g , Double Layered (3 Ply) Washable Green Mask. , Disposable Dual Heated Neonatal And Pediatric Ventilator Circuit: • The Circuit Should Be Compatible With Infant Ventilator With Flow > 4 L/Min As Well As < 4 L/ Min. • The Circuit Should Be Dual-Heated. • The Length Of Inspiratory Limb Should Be At-Least 1 M And Should Be Supplied With 0.3 M Incubator Extension. • It Should Have An Autofeedhumidifier Chamber. • The Expiratory Tube Should Have Heating Element With-In The Circuit In-Order To Avoid Condensation Or Rain Drop-Out. • The Length Of Expiratory Limb Should Be At-Least 1.5 M. • It Should Have Humidifier Connection Tube With No Port, Swivel Wye-Piece, Pressure Line, Different Adaptors For Ventilators In Use In Various Hospitals (Drager/Maquet& Sle Ventilators). • Limbs Shouldn’T Made With Natural Rubber Latex. • It Should Be Disposable According To Hospital Protocol. , Suction Machine & Apparatus : Powder Coated Mild Steel Cabinet • Rotary Vane Type Pump With -710 ± 10 Mm Hg • Noise Level Of Suction Apparatus Is 50 Db ± 03 Db • 2 X 2.0 Ltrs. Glass Jars With Overflow Safety Device • Free Air Displacement 28 ~ 33 Ltrs • Electrical Requirement - 220~230Vac, 50Hz, 1Phase • Heavy Duty Hn-50 Castors • 1/2 H.P. Crompton Motors. • 63 Mm Vacuum Gauge • Non Collapsible Suction Tubing , High Flow Nasal Cannula–Newborn, Infant, & Paediatric: The Cannula Should Be Anatomically Contoured To Fit Preterm, Term Neonates, Infants And Pediatric Population. Nasal Cannula Diameter Should Be Suitable To Fit Preterm, Term Neonates, Infants And Pediatric Population To Deliver Wide Range Of Flows To Allow Flexibility Of Treatments. Suitable For Delivery Of Flows Between 2-25 L/Min. Made Of Soft Material To Minimize Nasal Trauma & Should Be Made Of Free Tubing’S Materials E.G. Latex Free / Thermoplastic Elastomer (Tpe) / Medical Pvc. Should Have Adhesive That Stick On Skin To Secure Prongs. The Material Of Adhesive Tape Should Be Suitable For Use In Preterm Neonates (Preferably Hydrocolloid). Adhesive Pads Should Be Easily Replaceable In Case Of Long Duration Use. , Micropipette , Automatic Fixed Volume Dispenser Of Different Volume With Spare Parts 10, 20, 50, 100, 200, 500, 1000 Micro Litre Is 4364, Is 5155 , Apd Cassette 4 Prong Specification : Automated Pd Set W/4 Prong Cassette ; 4 Inlets ; 1 Outlet; 1 Patient Connect More Than 5Ft Tube; Compatible With Apd Cycler , Ca 250 Line Specification : Ca 250 Line - Prismaflex Calcium Line/ Ca250 Lines: Used With Regional Citrate Anticoagulation For Compensating Patients Calcium , Manual Pd Drain Bag 2 Lits Specification : Capd Sample Disconnect Set For 2 Its Compatible Pd Bags Compatible With Patient Used Transfer Set , Oxiris Specification : Having Three Layers For Removing Cytokines, Endotoxins And Performing Crrt All Together. An69 Layer Removes Cytokines, Pei Layers Remove Endotoxins And A Heparin Graft Is Present For Maintaining Thrombogenecity. Applicable For More Than 30Kg Patient. Filter Surface Area 1.5M2. Extracorporeal Blood Bolume: 193Ml. Specifically Indicated For Sepsis+Aki , Pd Drain Bag 15 Lts (In Pairs) Specification : Cycler Drainage Set / 15 Its Apd Drain Bag ; Compatible With Patient Used 4 Prong Apd Cassette , Peel Apart Introducer For Tenckhoff Catheter Specification : 16 Fr. Pull Apart Sheath And Dilator, Introducer Needle, Guide Wire All Compatible With 31, 37 And 42 Cm Tenckhoff Pd Catheter , Peritoneal Dialysis Catheter Set W/2 Cuffs 57 Cm Coiled Specification : Catheter 57Cm Straight With Coiled Tip; Should Come In A Sterile Pack, Numerous Inflow/Outflow Holes, Made Of Translucent Medical Grade Silicon Rubber, Radiopaque Stripe, Beta-Cap Adapter, Beta-Cap Clamp, Two Attached Cuffs. , Peritoneal Dialysis Catheter Set W/2 Cuffs 62 Cm Coiled Specification : Catheter 63 Cm Straight With Coiled Tip; Should Come In A Sterile Pack, Numerous Inflow/Outflow Holes, Made Of Translucent Medical Grade Silicon Rubber, Radiopaque Stripe, Beta-Cap Adapter, Beta-Cap Clamp, Two Attached Cuffs. , Prismaflex Hf20 Specification : Filter Having Paes Membrane For More Bio Compatibility, Applicable For 8-11Kg Patient. Filtersurface Area 0.2 M2. Extracorporeal Blood Volume: 58Ml. , Prismaflex M60 Specification : Filter Having An69 Membrane , Applicable For 11-30Kg Patient. Filter Surface Area 0.6M2. Extracorporeal Blood Bolume: 93Ml. , Prismaflex M100 Specification : Filter Having An69 Membrane , Applicable For More Than 30Kg Patient. Filter Surface Area 0.9M2. Extracorporeal Blood Bolume: 152 Ml. , Prismaflex M150 Specification : Filter Having An69 Membrane , Applicable For More Than 30Kg Patient. Filter Surface Area 0.9M2. Extracorporeal Blood Bolume: 152 Ml. , Quinton Catheter Accessories Specification : Hd Permanent Single Cuff Staggered Tip Catheter Double Lumen Straight 14.5 Fr (Tip To Cuff 19Cm, Right Side); Catheter Should Come In A Kit With Carbothane/Silicon Catheter, Introducer Needle, Guide Wire, Syringe, Dilator, Island Dressings, Sealing Caps And 16 Fr. Pull Apart Sheath And Tunneling Stylet.Flow Rate Min 450 Ml/Min. Catheter Should Be Us/Fda Approved. , Soft Tenckhoff Pd Catheter 37 Cm Straight Double Cuff. Specification : Catheter 36Cm Straight ; Should Come In A Sterile Pack, Numerous Inflow/Outflow Holes, Made Of Translucent Medical Grade Silicon Rubber, Radiopaque Stripe, Beta-Cap Adapter, Beta-Cap Clamp, Two Attached Cuffs. , Soft Tenckhoff Pd Catheter 42 Cm Straight Double Cuff. Specification : Catheter 42-43Cm Straight ; Should Come In A Sterile Pack, Numerous Inflow/Outflow Holes, Made Of Translucent Medical Grade Silicon Rubber, Radiopaque Stripe, Beta-Cap Adapter, Beta-Cap Clamp, Two Attached Cuffs. , Stiff Pd Catheter (Paediatric) Specification : Stiff Tenckhoff-Type Catheter For Peritoneal Dialysis (Pd), Suitable For Surgical, Laparoscopic, Or Percutaneous Insertion. Designed For Optimal Inflow/Outflow, With Biocompatible Materials For Temporary Or Permanent Access.Material (• Medical-Grade Biocompatible Silicone • Non-Toxic, Non-Pyrogenic, Latex-Free, Dehp-Free •Radiopaque For X-Ray Visibility)• Straight Or Curved Configuration With Double Dacron Cuffs • Multiple Side Holes Near Tip For Optimal Dialysate Flow • Includes Removable/Fixed Stiffening Wire Or Stylet. Outer Diameter (Od)-3.5–4.5 Mm (10–12 Fr).Length - 30–36 Cm. Cuff Position- Proximal: 1–2 Cm From Exit , Distal: 6–8 Cm From Tip.Two (Double Cuffed), Straight (Preferred). Accessories(• Stylet Or Stiffening Wire • Tunneler • Trocar (If Applicable) • Transfer Set Connector/Adaptor • End Cap • Sterile Pack With User Manual)• Eto Sterilized Or Equivalent • Shelf Life: Minimum 3 Years • Sal: 10?6. • Ce Marked / Us Fda / Cdsco Approved • Manufacturer Must Be Iso 13485 Certified.• Individually Sterile-Packed • Label Must Include Product Code, Size, Expiry, Batch Number, Manufacturer, Sterilization Method.• Supplier To Provide User Training/Demo If Needed • Certificate Of Analysis (Coa) And Sterility Certificate With Each Batch • Warranty Against Manufacturing Defects , Stiff Pd Catheter (Adult) Specification : Stiff Tenckhoff-Type Catheter For Peritoneal Dialysis (Pd), Suitable For Surgical, Laparoscopic, Or Percutaneous Insertion. Designed For Optimal Inflow/Outflow, With Biocompatible Materials For Temporary Or Permanent Access.Material (• Medical-Grade Biocompatible Silicone • Non-Toxic, Non-Pyrogenic, Latex-Free, Dehp-Free •Radiopaque For X-Ray Visibility)• Straight Or Curved Configuration With Double Dacron Cuffs • Multiple Side Holes Near Tip For Optimal Dialysate Flow • Includes Removable/Fixed Stiffening Wire Or Stylet. Outer Diameter (Od)-4.5–5.5 Mm (14–16 Fr).Length - 42–48 Cm. Cuff Position- Proximal: 1–2 Cm From Exit ,Distal: 8–10 Cm From Tip. Two (Double Cuffed), Straight Or Curved. Accessories(• Stylet Or Stiffening Wire • Tunneler • Trocar (If Applicable) • Transfer Set Connector/Adaptor • End Cap • Sterile Pack With User Manual)• Eto Sterilized Or Equivalent • Shelf Life: Minimum 3 Years • Sal: 10?6. • Ce Marked / Us Fda / Cdsco Approved • Manufacturer Must Be Iso 13485 Certified.• Individually Sterile-Packed • Label Must Include Product Code, Size, Expiry, Batch Number, Manufacturer, Sterilization Method.• Supplier To Provide User Training/Demo If Needed • Certificate Of Analysis (Coa) And Sterility Certificate With Each Batch • Warranty Against Manufacturing Defects , Important Note: 1. All Prospective Bidders Are Requested To Quote The Rate In Boq As Per Accounting Unit (Au) Repeat As Per Accounting Unit (Au) & Item Specifications As Mentioned In The Table-1. Wrong Quoting Of The Rate In Boq Will Be Dealt With As Per Penal Provisions Of The T&C Of The Tender. 2. Quality Of The Product Supplied, May Be Ascertained By Testing / Physical Examination By The Experts At Any Stage Of The Tender Period. 3. The Equipment Should Be Us Fda/ Ce/ Bis/ Cdsco Approved (Us Fda/ Ce Requirements Will Be Applicable Only When The Indian Standards Like Bis/ Cdsco Is Not Available). 4. The Prospective Bidders Of The Said Tender Are Requested To Make A Declaration In Affidavit Under Annexure Vi(B)In Case Of Sole Manufacturer/Importer (I.E. Proprietary In Nature). 5. If The Item(S) Under Sole Manufacturer / Importer Is (Are) Proprietary In Nature, Quarterly Intimation Is Solicited From The Approved Bidders Positively Regarding The Status Of Their Item(S) Proprietary In Nature, Otherwise Their Item(S) Will Be Blocked In The Smis. 6. In Case Of Tie Bid, Decision Will Be Taken By The Tia As Per G.O. No. 2320-F(Y), Dated 07.06.2022 Issued From Finance Department Audit Branch (Group T).