Tender For Work No-91 Renovation Work Of The House Chamber In The Municipal Corporation Headquarters. - CIVIL WORKEarth workProviding preconstructional antitermite treatment and creating and chemical barrier under and around the coloumn pits wall trenches bascement excavation top surface inplinth filling juction of wall and floor, along the external per meter of binding expansion joints surrounding of pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measurd as per I.S. 6313(part Il 1981) Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor of chlordance will be used. The rate of application of chemicalemulsion shall be as follows :-1) Treatment for massonary and foundation 5 litesper sqmBack fill in immediate contact with foundation7 .. 5 lites per sqm3) Treatment of surface of plinth filling 5 lites per sqmTreatment of soil along external permeter of4)and injecting chemical for2)Building 2.25 liter per linear meter of theperimetr wall5) Treatment of soil under external permeter 5lites per sqm 2 BRICK WORKBrick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in :Cement mortar 1:4(1 cement:4 coarse sand) 3 1PLASTER WORK2MM cement plaster on rought side of single or half brick wall of mix1:4 (1 cement : 4 coarse sand) 4 PAINTING Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. 5 Finishing walls with ready mixed Premium acrylic emulsion paint (CompanyDepot Tinted) having VOC less than 50 gm/litre and UV resistance as perIS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint ofrequired shade with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqmover and including priming coat of exterior primer applied @0.90 litre/10 sqm. 6 FLOORING38 mm thick wood block flooring of first class teak wood laid over 25 mmthick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand:4 graded stone aggregate 10 mm nominal size) to be paid separately,coated with a thin layer of hot bitumen penetration 80/25 (blown type)@ 2.45 kg per sqm, including fixing blocks in position after dipping inhot bitumen (blown type) up to half depth, planed, levelled smooth andfinished complete. 7 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm includinggrouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gentlyand easily.Size of Tile 600 x 1200 mm 8 FALSE CEILINGSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(Fabrication drawing of the trusses to be submitted by contractor before the excuction)Hot finished seamless type tubes 9 Painting roofs or other iron in large areas with one coat priming and coat of approved(above one sq. metre) paint(british antesol or equivalent) including supply of all materials, labour, tools and plants etc. required for proper completion of the work. Paint to be used should confirm the ISI no 103-109. 10 DoorProviding wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately).SAL WOOD 11 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:30mm thick including ISI marked Stainless Steel butt hingeswith necessary screws 12 Providing & Fixing 1.00mm thick decorative highpressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quantity conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 13 P/f alluminium tower bolts isi marked anodised (anodic coating not less than grade AC 10 as per isi:1868)transparent or dyed to reuired colour or shade with necessary screw etc.complete300x10mm 14 Providing and fixing alluminium handles isi marked anodised (anodic coating not less than grade AC 10 as per isi:1868)transparent or dyed to reuired colour or shade with necessary screw etc.complete125mm 15 BACK WALL PANELProviding and fixing Fluted louver panels 4 wide 10 length inbcluding all necessery tools and labours 16 Providing and fixing 6mm thick ply board for surface making 17 Providing and fixing 0.1mm thick matt finished laminate as per selection 18 Providing and fixing cobe light as per the design on wall panelling area including all necesseryt items 19 Application: Hall Wall Absorption NRC 1 ( 1.2m Wall Height )Supplying & FixingStretch Fabric premium System on G.I studs 2400mm X 50mm web, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick insulation.Fibrette 600x1200x20mm tile with NRC 1.00 to be mechanically fastened on the G.I Studs. Acoustical infill of absorbwool 10mm which is adhered to the acoustical panel on the front side. Then 12mm/20mm Vinyl tracks are screw fixed on to the 6mm Ply and Acoustics panels. Then the fabric is stretchedover the Vinyl tracks. The installed system should provide NRC OF 1.00.Fabric colour as per Architect choice-Ref attached specifications for more details. To be installed on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving ithigh strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing of. 50mm thick,1000 GSM absorb wool tested as per Fire Retardant ASTMD 635-1991/Insulation and IS 15061-2002for excellent results.Make: Himalyan Acoustics/Heradesign/BAUX OR equevalent approved by architect.Ground floor hall wall area-85.2add 10% extra-9Coulumn area-01-32Coulumn area-02-16 20 Application: Hall Wall Absorption NRC 0.88 (Upto 2.4m Wall Height)Supplying & fixing Acoustics ‘’ Woodlot ’’ Premium 2430x131x16mm made of exterior grade HDF backed with acoustical Fleece providing sound absorption of 0.88 NRC as per ISO 354.To be installed with 15mm Aluminium profile conforms to Aluminium Alloy 6063-T 6.Temper As per BS:1474- 1987 and G.I Lock in clips on the back of tongue and Groove system. The density per panel is 750-800 kg/m3.The panels come with tongue & groove for seamless patterns,4-28mm Groove and visible panel. These slats are made from acoustical fibreboard with linear perforations for excellent uniformity. The perpendicular holes are available on the back of panel which are covered by black acoustical fleece. Achieves sound reduction of 0.88 NRC.To be installed on G.I studs 600x600mm centre to centre2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dippedgalvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life witha backing of 50mm thick,1000 GSM absorb wool tested as per Fire Retardant ASTMD 635-1991/Insulation and IS15061-2002 for excellent resultsMake: Himalyan Acoustics/Heradesign/BAUX OR equevalent approved by architect.Ground floor hall wall area-85add 10% extra-9Coulumn area-01-32Coulumn area-02-16 21 SUB-HEAD-I: CIRCUIT CUM POINT WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group-C (Primary point ) 22 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 23 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 24 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 25 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25/32 A modular socket outlet and 25/32 A modular SP MCB, “C” curve including connections, painting etc. as required. 26 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire For 6A Point 27 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire For 6A & Light Circuit Point 28 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire For 16A Power Circuit Point 29 SUB-HEAD-II:- DISTRIBUTION BOARDSSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections,powderpaintedincludingearthingetc.as required. (But without MCB/RCCB/Isolator)12 way, Double door 30 Supplyingand fixingoffollowingwayssurface/recess mounting,verticaltype,415V,TPNMCBdistributionboardof sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door 31 Supplyingandfixing5Ato32Arating,240/415V,10kA,C curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesintheexistingMCBDBcompletewithconnections, testing and commissioning etc. as required.Single Pole 32 Supplying and fixing following rating, double pole, 240 V, isolatorintheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required.40 A 33 Supplying and fixing following rating, four pole, 415 V, isolator intheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required.63 A 34 Supplyingandfixingfollowingrating,doublepole,(singlephase andneutral),240V,residualcurrentcircuitbreaker(RCCB), havingasensitivitycurrent30mAintheexistingMCBDB completewithconnections,testingandcommissioningetc.asrequired.40 A 35 Supplyingandfixingfollowingrating,doublepole,(singlephase andneutral),240V,residualcurrentcircuitbreaker(RCCB), havingasensitivitycurrent30mAintheexistingMCBDB completewithconnections,testingandcommissioningetc.asrequired.63 A 36 SUB-HEAD-III:- SUPPLY & FIXING OF LIGHTING FIXTURES.Supplying, installing, Fixing, testing and commissioning of Recessed mounting LED 36W LED recessed grid-ceiling luminaire, suitable for 600x600 module with White Powder Coated and enclosed with high efficientUV resistance flat low glarediffuser assembled with low trim metal frame. Constant Current Driver with THD≤ 10% Power Factor above 0.9 avilable in 3000K/4000K/6000K with CRI above 80, Compliance with LM 80 Standards with L70-50,000 burning hours Life, Efficacy -≥100 lm/W, IP PROTECTION -IP 20, single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (Make: Legero, Model no.Modena LER 2636 or Equivalent Philips, Syska LED) 37 Supply,Installation,TestingandCommissioningof1200mm sweep,BEE5starrated,ceilingfanwithBrushLessDirect Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm longdownrod,2nos.canopies,shacklekit,safetyrope,copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum6.00,Airdeliveryminimum210Cum/Min,350RPM (toleranceasperIS:374-2019),THDlessthan10%,remoteor electronicregulatorunitforspeed controland all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 38 SUB HEAD- IV: EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 39 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 40 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 41 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. 42 SUB HEAD- V: LT CABLESSupply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surfacethecablerunshallbefixedonM.S.clampsetc.of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.95 sq. mm 3-1/2 core 43 Supplyingandmakingendterminationwithbrasscompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.3½ X 95 sq. mm (45mm) 44 EXECUTIVE CHAIR 45 VISITORS CHAIR 46 Providing and fixing Laminates of aprroved color and texture on tables and partitions 47 Providind fixing fevicol 15kg pack for the application of laminates 48 Labour charges of applying laminates and other related work