| 1 | [23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE [Through Rate] |
| 2 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 3 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 4 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 5 | [24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate] |
| 6 | [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] |
| 7 | Supply and erection of Traffic Light Assembly with following features: - 300mm dia LED Lamp- Size min. 385X385mm- Material of Assembly- Polycarbonate Plastic - Material of Hood - HDPE Plastic- Length of Hood - Min. 250mm- Certifications- IP-65 approved as per IEC60529- Lamp - LED type (5mm dia LEDs)-LEDs inLamp-Red/Amber-190Nos. andGreen Arrow - 66 Nos. - Light Intensity of LEDs - Min. 5000mCd- Currentof LED Lamp - 20mA forward Current-Wattage of LED Lamp-6Watt nominal for red/amber and 4 Watt for Green (Make- RRE/CMS/BEL/KELTRONRED/ AMBER BALL TYPE |
| 8 | Supplyanderectionof TrafficLightAssemblywith following features: - 300mm dia LED Lamp- Size min. 385X385mm- Material of Assembly- Polycarbonate Plastic - Material of Hood - HDPE Plastic- Length of Hood - Min. 250mm- Certifications- IP-65 approved as per IEC60529- Lamp - LED type (5mm dia LEDs)-LEDs inLamp-Red/Amber-190Nos. andGreen Arrow - 66 Nos. - Light Intensity of LEDs - Min. 5000mCd- Currentof LED Lamp - 20mA forward Current-Wattage of LED Lamp-6Watt nominal for red/amber and 4 Watt for Green (Make- RRE/CMS/BEL/KELTRONGREEN COLOUR IN ARROW |
| 9 | Supplyanderectionof TrafficLightAssemblywith following features: - 300mm dia LED Lamp- Size min. 385X385mm- Material of Assembly- Polycarbonate Plastic - Material of Hood - HDPE Plastic- Length of Hood - Min. 250mm- Certifications- IP-65 approved as per IEC60529- Lamp - LED type (5mm dia LEDs)-LEDs inLamp-Red/Amber-190Nos. andGreen Arrow - 66 Nos. - Light Intensity of LEDs - Min. 5000mCd- Currentof LED Lamp - 20mA forward Current-Wattage of LED Lamp-6Watt nominal for red/amber and 4 Watt for Green (Make- RRE/CMS/BEL/KELTRONPEDESTRIAN ASSEMBLY WITH RED STANDING and GREEN WALKING TYPE |
| 10 | S/E of fully adaptive Intelligent traffic Light Control Systemtorun3/4/5/6 roador roundabout traffic signal system as per site requirements of traffic flow and osendrealtime adaptive data to Downcounter Timers and communicate with Internet based Servers. The following minimum specifications shall be provided:-Controller shall have facility for Fixed Mode/ VehicleActuatedMode/AreaTrafficControl (ATCS) modeandshall support InternetCommunicationin all modes-Controller shall haveuptominimum64different lights for various roads ormaximumas per site requirement-Max. twosetsofLightsshallbeoperatedonone output to prevent failure of all traffic signals-Provision for atleast 10different typesofphase timings per day in fixedmode/ realtime phase timings in vehicle Actuated mode as per traffic flow-Controller shouldbeabletoworkwithCamera/ radarsensors ifavailableatsiteinVehicleActuated Control Mode or Area Traffic Control Modes-ShallhaveinbuiltNon-VolatileRAMtostoredatain case of long power failure-Various ports suchas Serial/RS232/Digital Input and Internet/Wifi Ports shall be available-Police Control Application shall be provided for local operation inChowkAreaandapplication for long distance Control Room Operation.-TrafficPolice/ Site Incharge/ Electricianshould receivemessage/notificationincaseofPower fail/ Signal OFF-All TrafficControllerDatashall bechangedfrom any nearby locationor city remote control room location- Internet Package Support is in-built-Controller shouldhave capability to receiveand execute all commands such as-All Lights OFF, particularGreenSequenceON/OFF,BlinkerON,All RED, Time Increase or Decrease, Sets Data Change-TrafficPolice/ Site Incharge/ Electricianshould receive notification in case of Power fail/ Signal OFF-All TrafficControllerDatashall bechangedfrom any nearby locationor city remote control room location- Internet Package Support is in-built- Time Synchronisation through GPS/GSM Modems-Local control at site level or remoteapplication shall be inbuilt-RemoteSoftware/Applicationshallbeprovidedto Police/Municipal Corporation and maintenance support for minimum 3 years shall be included.- Mobile Application for local junction is included.-Municipal Authorities can check log details of power, signal On/OFF of controller for 6 months-LiveViewofTrafficLightfunctioningin4g/5gtime lag-Vehicle Actuation System-Inbuilt and all parameters such as Minimum Time, Maximum Number of Cycles, Skip to times should be configurable-Controller shouldsenddatatothedowncounter timersinrealtimeandalsosendSKIPDatatimingsin every step -VehicleActuationparametersshallbeconfigurable from control room-Upto5locationsControlRoomapplicationsmaybe allowed and served-ControllershallbetestedfromNABLLabsandtest report to be attached before installation at site (Make of Controllers- RRE/CMS/BEL/KELTRON) |
| 11 | SupplyanderectionofCantileverGIpoleforTraffic Signals 9.00 mtr long with following minimum specifications:-All Pipeused infabricationofpoleshall beGI B Class of Tata/Jindal make only- Length of Lower portion – 6 mtr long 150mm dia- Length of upper portion-3 mtr long 125mm dia- Cantilever portion – 4 meter long 50 mm dia -Plates and Flanges–270mmdia 6mm thick minimum all of Mild Steel- Foundation size- 0.6X 0.6 X 1.5 mtr - Foundation Concrete Ratio- M20 - Termination of Cables – Top of pole -_Reinforced Plastic Junction Box to prevent induction at top and NO junction box shall be provided at lower level to prevent from theft-Dual coatofpaint inGoldenYellow/Greyshade after etching and primer coats |
| 12 | Supply and erection of GI pole 6mtr long with following minimum specifications:- All Pipe used in fabrication of pole shall be GI A Class of Tata/Jindal make only- Length of Lower portion – 6 mtr long 150mm dia- Plates and Flanges – 200mm dia 3mm thick minimum - Foundation- 0.5 x 0.5 X 1 mtr - Foundation Concrete Ratio- M20 - Termination of Cables – Top of pole- Reinforced Plastic Junction Box to prevent induction at top and NO junction box shall be provided at lower level to prevent from theft- Dual coat of paint in Golden Yellow/ Grey shade after etching and primer coats |
| 13 | S/E of fully adaptive and ATCS Mode compatible real time live working Downcounting Displays with the following features: The display shall have three sections with following hardware and software features: Mode of Communications:- Adaptive Mode: The Downcounting Display shall receive live inputs from Controller to display the Red/Green time as per Vehicle Detector inputs and should show green light SKIP if the vehicles are not present on the road at that moment. Similarly it should show GO and STOP on start of Green and Red Lights respectively. Time values should change immediately.- ATCS Mode: The Downcounting Display shall receive live inputs from Controller to display the Red/Green time as per Vehicle Detector inputs and should work in realtime with active commands from the ATCS Controller at site via LAN Cable Ethernet communication- Normal/fixed Mode- The Downcounting Display shall receive inputs from Traffic Signal Lamps and display the remaining time when ATCS Mode is not available. The display shall weather-poof, and excellent capability of antisepsis, waterproof. • Display Size – 384mm X 768mm X 100mm • No. of LED Pixels in Frame- 128 X 256 • LED pitch- 6mm • Brightness- 5000mCd • LED Config- 1R, 1G, 1B in 1 SMD• Modular Construction ensures easy carrying and assembling. • Power Supply Bank of min Capacity 20Amperes @5V. • Housing /Display – MS CRCA Sheet Thickness- 1.5mm •Available Modes of Communication- a) Modbus TCP/IP Ethernetb) Digital Input c) Serial CAN interfaces (Make- RRE/CMS/BEL/KELTRON) |
| 14 | S/E of MS Aspect holding Stand for 2/3/4/5 Aspect Light fabricated from 3mm thick MS Flat complete in all respects |
| 15 | S/E of Backing strips of reflective Silver /White colour for LED Traffic Assemblies to be fabricated for 2/3/4/5 Aspect Assemblies |
| 16 | S/E of Video Camera based Traffic and Human pedestrian detection System recording facility for each road of the junction with the following minimum specifications: - Image Sensor1/2.7? Progressive Scan CMOS-Pixels Minimum2.0mp-Video CompressionH.264, H.265 and Motion JPEG-Video Bit rate32 Kbps –16 Mbps-Memory 500 MB RAM-Frame Rate SupportBetween 20 to 30 fps-Minimum Illumination Color: 0.002Lux @ (F1.2, AGC ON), Black and white:0.0002Lux@ (F2.0, AGC ON)-Shutter Speed1/3 s - 1/100,000 s-S/N Ratio 50 dB or better-Video StandardPAL-Lens MountCS or C Mount-Lens Type Varifocal, C/CS Mount-Lens 3mm - 12 mm or as per site requirement-Focus Simple focus / Manual, Button control (Manual, Simple focus)-Day/Night ModeAuto (ICR) /Color / B/W Configuration-Function:Vehicle Detector for counting of vehicles at each arm of the traffic junctions. The detector to be managed through web-based interface locally. The outputs of the detectors shall indicate the presence of vehicles and shall be used to influence the operation of the traffic signal controller and shall generate counts.- The Detector system should send traffic flow data to the Server and show the counts of vehicles per hour basis or in format as desired. - Width of Detection 1 to 3 lanes- IR Detection (In-Built or external) - IntegrationThe camera shall provide view of the area covered.- EnclosureExternal IP rated housing- Certification CE/FCC/BIS- Makes: Traficam/Trafiloop/Vehant/ VIION/Video netic |
| 17 | S/E of Junction Box of size 300mmX300mmx200mmfabricated from 1.5mm thick MS Sheet with mounting clamps and provided with pipe inlet and |
| 18 | S/E of PVC under ground copper conductor Cable with following minimum specifications:- Size ofConductor 1.5mm Sq mm- Number of Cores – 14 Core - Standards – ISS 1554-1998 - Placement of cables - In existing pipe or in trench |
| 19 | S/E of PVC under ground copper conductor Cable with following minimum specifications:- Size of Copper Conductor 1.5mm Sq mm- Number of Cores – 8 Core - Standards – ISS 1554-1998 - Placement of cables - In existing pipe or in trench |
| 20 | Laying of Undeground Cables Via trenchless boring to be laid atleast 1.5 meters deep below ground level at the lowest point. Cost includes making pits on both sides of the road and refilling the same with dug out earth to restore to the original finish complete in all respects |
| 21 | Laying of Undeground Cables by machine slit cutting 100m X100mmX 50mm Cut through deployment of machines. Cost shall include recarpeting with CC Mixture and Tar and restoration to the original finish |
| 22 | S/E of ISI marked Wire to connect LED Assemblies with Copper Cable Termination boxeswith minimum following specifications: - PVC copper conductor 6 core 1mmsq. |
| 23 | S/E of Battery Bank- Capacity of Battery Bank 300Amp-Hr - Voltage – 24V DC (12v connected in series)- Make of batteries – Exide - Type of battery - Sealed Maintenance free LeadAcid Battery- Placement of battery - In existing Panels/MS Boxes - Theft arrangement provision shall be |
| 24 | S/E of AC-DC Rectifier Unit- Type of rectifier- Transformer Type- Voltage tappings - 24V /12V DC - Capacity - Upto 20Ampere Capacity @24V DC |
| 25 | S/E of Battery Charger Systems - Type of Charger - Industrial Grade Intelligent Charger- Capacity -upto 1400W - Battery Capacity to be charged - 300Ahbatteries @ 24V - Charging- Float charging - Cutoffs - Low/high voltage cut-off- 12V Charging Option should also be provided (Make- APLAB/ELAK/RRE/EXIDE) |
| 26 | S/E of Traffic Signal control panel box with special theft proof arrangements including multiple cabins for housing battery, battery charger unit, control system and sub control unit with Rectifier unit- Size of Box - 900 X 600 X 600mm (Nominal) - Type of Sheet – Mild Steeel CRGA- Thickness of Sheet – 1.6mm - Coating on Box- Powder Coating in Grey Colour- Ventilation- Forced Cooling with Fans- Locking Arrangment- Almirah type and TheftProof- Antennae for Controller intrenet communication- Intenal Supports – MS Angle Iron/Flats - Mounting in Earth - Pedestal box shall have 4 legs 70cm long of 35 x35x 6mm - Foundation depth – 400mm deep- Foundation Concrete Ratio- M20 |
| 27 | S/E of 12 Port Layer 2 LAN Switch for connecting the Downcounter Timers, ameras, Controller and internet routers together make including cost of programming at site and setup (Make: Netgear/Cisco/Dell/TP-Link/D-Link) |
| 28 | Provision of Internet Connectivity by providing high speed4G/5G connectivity at all junctions by Sim Cards/Internet from Jio/Airtel/Idea/Vodafone/BSNL including all activation charges etc and to be provided at individual sites on per month sites |
| 29 | S/E of underground grade double jacket cable LAN Cat 6e cable for connecting Cameras and Timers to the Control Panel complete in all respects |
| 30 | Maintenance Charges for T traffic Signals system for a periodof2yearsafterexpiryof12monthwarranty including cost of manpower, vehicles, transportation, reprogramming ofMicrocontroller, repair and replacement of damaged controller components, but does not include accidents damages, road cutting damages etc complete in all respectsNOTE BREAKDOWN COMPLAINTATTEND IN VARIU |