Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-12-2025 | TD DRG | Other | 26-12-2025 |
| 2 | 12-12-2025 | REV OF DRG-1 | Other | 26-12-2025 |
| 3 | 12-12-2025 | REV OF DRG | Other | 26-12-2025 |
| 4 | 12-12-2025 | BOQ REVISION | BOQ | 26-12-2025 |
| 5 | 04-12-2025 | DATECORRNO10 | Date | 19-12-2025 |
| 6 | 27-11-2025 | DATECORRNO09 | Date | 12-12-2025 |
| 7 | 20-11-2025 | DATE CORR No08 | Date | 05-12-2025 |
| 8 | 14-11-2025 | DATE_CORRNO07 | Date | 28-11-2025 |
| 9 | 06-11-2025 | DATE_CORRNO06 | Date | 21-11-2025 |
| 10 | 30-10-2025 | DATECORRNO05 | Date | 14-11-2025 |
| 11 | 23-10-2025 | DATECORR | Date | 07-11-2025 |
| 12 | 15-10-2025 | DATE CORR No03 | Date | 31-10-2025 |
| 13 | 08-10-2025 | DTCORR08.10 | Date | 24-10-2025 |
| 14 | 30-09-2025 | DATE CORR | Date | 17-10-2025 |
| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Design, fabrication, erection & construction of store for AC Tyres, Rubberised spare, AC Plant & AHU room, Office bldgand connected amenties as shown in PLAN DRG NO CE (AF)/PRZ/1214/AR Sheet 1/1 and oher drgs as per List of Drgs (TOTAL AREA 1816.35 SQ MTR)usingstructure combined with PEB steel structure complete all as specified as shown in drawings:-Note: - (a) Building shall be constructed with PEB technology designed as per approved design parameters.(b) Building shall be constructed as a composite building wherever shown in the drgs or as directed by employer/its representative. |
| 3 | Sch A Part II (INTERNAL WATER SUPPLY) |
| 4 | Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II. |
| 5 | Sch A Part III (INTERNAL ELECTRIFICATIONS) |
| 6 | Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III . |
| 7 | Sch A Part IV (EXTERNAL WATER SUPPLY) |
| 8 | Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV . |
| 9 | Sch A Part V (EXTERNAL ELECTRIFICATIONS AND DEG SET) |
| 10 | Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V. |
| 11 | Sch A Part VI (SEWAGE DISPOSAL) |
| 12 | Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI. |
| 13 | Sch A Part VII (LIGHTENING PROTECTION) |
| 14 | Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII |
| 15 | Sch A Part VIII(ROAD, PATH, CULVERT AND RAMP) |
| 16 | Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII |
| 17 | Sch A Part IX (FENCING AND GATE) |
| 18 | Lump sum price worked out by the contractor for Demolition and Dismantling as listed in Sch ‘A’ Part IX |
| 19 | Sch A Part X (SITE CLEARANCE & DEVELOPMENT) |
| 20 | Lump sum price worked out by the contractor for Site Clearance & Development as listed in Sch ‘A’ Part X |
| 21 | Sch A PartXI (Miscellaneous Items of B/R and E/M) |
| 22 | S&F in repair factory made perforated Precast RCC drain cover 75 mm thick of any shape & size incl 1mm thick MS Sheet all around the cover all as specified and as directed |
| 23 | S& F On site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., including 100 mm th PCC 1:2:4all around complete for 20 Users With UPFLOW FILTER INLCUDING MEDIA |
| 24 | M & L for Soakage, well includingexcavation in ordinary soil, foundation in PCC 1:3:6, wells of honey combed and solid brick work in CM 1:4 , RCC slab covers, filling with brick bats, complete of 2.4 M dia X 3.0 M effective depth for 20 Users Complete all as specified and shown in relevent TD Drg. |
| 25 | Supply, Installation, commissioning & testing of horizontal, water-cooled, floor-mounted compact chiller unit of actual Minimum Cooling Capacity 3 x not less than 26 TR 2Working +1Standby), at local ambient conditions at Agra, with scroll-type multiple compressor (s), star/delta starter, S/T type water cooled condenser, S/T type insulated evaporator, step control as per manufacturer, common base frame, interconnected copper refrigerant piping, vibration isolators, gauge panel, automatic safety controls, Ozone friendly CFC-free refrigerant gas R-407C/134a & oil, polyvinyl nitrile rubber insulation of chiller and suction pipe. The motor shall be suitable for operation on 415 Volt ± 10%, 3-Phase, 50 Hz AC power supply. The chiller unit shall be complete with its microprocessor based control panel with starter for motors and condensors, required capacity capacitor bank, under and over voltage protection, single phase preventor, communication card starter with main switch. The chiller panel shall be compatible for remote control operation & should provide status (additional potential free contacts shallbe required to perform this function). The chiller unit should be complete with discharge service valves to isolate refrigeration circuit, vibration isolators, antifreeze thermostat. Necessary civil work viz. PCC foundation, iron structure for placement of chillers, shall be covered in the scope of work. The chiller shall be as per the approved particulartechnical specifications and shall meet the following tentative design criteria: |
| 26 | [a] Max Local ambient temperature: 105 °F[b] Temperature drop through chiller : 4.4°C[d] Evaporator fouling factor: 0.0001° hr.Sq m2 / K Cal[e] Refrigerant (Ozone friendly type): R-407C/410/134aNote : 1. Temperature to be maintained by the plant is 20 + 5 degree celcius and R 4 up to 55+5.2. The contractor will check required TR of the chillers. In case there is requirement of higher capacity chiller than that mentioned in tender for maintaining temperature as specified above, he shall provide detailed Heat Load calculation in support of his claim within one month of acceptance of tender In case of requirement of TR more than specified in tender, financial adjustment will be done through DO. 3. Minimum CoP = 4.7 and Min IPLV = 5.8 4. The noise level at 2 m should not exceed 75 dba 5. The rate quoted is inclusive of micrprocessor controlled cxapacitior bank to ensure PF of 0.95 (minimum). 6. All cabling will be with XLPE armoured 1100 Volt fireretardent cable. Internal wiring in control panel should be with PVC insulated FRLSH copper cable |
| 27 | Supply, Installation, testing and commissioning of FRP bottle-shaped induced draft counter-flow, CTI certified cooling tower of capacity not less than65 TR and Flow rate matching with condensor water pump complete with FRP basin of capacity adequate for 30 min operation without make up water, PVC fills, SS sprinkler pipe with polypropylene nozzle, FRP body, hot-dipped galvanized suction and discharge screen, access ladder, weather-proof TEFC energy efficient electric motor complying to IS: 12615, IE 3 class, die-cast aluminium / FRP blade fan, motor guard, inlet, outlet, make up and quick-fill arrangement, drain and over-flow nozzle connections, etc. Note : 1. Cooling Tower should be suitable for refrigeration capacity plus heat of compression which is generally 20 % of refigeration capacity.2. Cooling Tower should be suitable to meet heat load in monsoon as well as summer for weather onditions of Agra. |
| 28 | Supply, Installation, testing & commissioning of double-skin type horizontal, floor-mounted, top / side discharge air handling unit of capacity not less than 20000 CFM at 75 mm water gauge static pressure having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 25 mm double skin panel with pressure injected CFC & HCFC free PUF with \"k\" value of 0.02 W /°C m & density not less than 38 Kg/Cum, pre-coated pre-plasticized galvanized outer and inner skin 0.8 mm thick with 120 gm per Sqmm thick Zinc coating, airtight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, copper coils of 6 rows deep with anti corrosion Aluminum fins with combination of hot and chilled, PVC Nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan (0.8 mm thick) of sufficient width and difffernetial slope to drain condensate water insulated wth 10 mm PUF / nitril rubber, pre-filters, inspection windows / doors, mixing box and supply / return / fresh air dampers, moisture drop eliminators. Note: Cost of necessary civil work viz PCC foundation for placement of AHU and electric cum control panel for auto operation of AHU shall be covered in the quoted rate. The AHU shall be as per the approved particular technical specifications and the following design criteria. |
| 29 | [a] Suitable DIDW forward fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 Volt ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, 2 nos suitably matched oil resistant belts, guard, double canvass connections with zip to discharge duct / plenum. [d] 50 mm thick washable HDPE, 90% down 10 micron pre-filtersand micro V filter with active coal , Micro V filter having dustfiltration capacity 95% down to 5 micron filters, fixing frame work, hinge type access doors. [e] 4 row deep chilled water coil section with aluminium fins and copper tube tested on 21 Kg per Sqcm with SS sandwiched drain tray.[f] 2 row deep heating coil section with copper fins and copper tube tested on 21 Kg per Sqcm with SS sandwiched drain tray. [g] 18 gauge MS CRCA duly powder coated AHU sub panel board in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor complete with relays, timers, contactors, PT, push buttons, switches, internal wiring. (h) Electrically controlled and operated humidistate and micro controller based temperature controller (i) Pan type humidistate and re-heaters to controll humidity in 50+20% (j) Aluminium extruded Fresh air intake louvers of suitable size as per fresh air requirement with bird screen, damper and rain protection Note: A copy of computer selection and drawing showing pipingand fitting connections of AHU shall be submitted to Accepting Officer for prior approval. The contractor wil submit total static pressure (inernal and external) to verify adequacy of static pressure of fan. |
| 30 | Supply, Installation, testing & commissioning of end-suction & top-discharge, back pullout typecentrifugal pumps for chilled water re-circulation-03 Nos (2Working +1Standby), complete with cast iron body, bronze impeller, mechanical seals, TEFC fan cooled type,squirrel cage high efficiency, IE3 classinduction motor, base plate, mounting channel frame, accessories and fittings i.e. mechanical seal, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3 Phase AC supply.The Pumps shall be insulated with expanded polysterene (TF quality) ofsuitable thickness but not less than 25 mm. The pump shall be suitable for given duty point as mentioned under :-[a] Capacity : 100 US GPMapprox [b] Head: 30 RM [c] Impeller: Bronze metal [d] Approximate Motor Rating: 3 HPNote :1. Pumpsets will be arranged in 2Working+1Standby configuration. Neccessary plumbing work will be done accordingly 2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO. |
| 31 | Supply, Installation, testing & commissioning of end-suction & top-discharge, back pullout type, centrifugal pumps for condensor water re-circulation-03 Nos (2Working+1Standby), complete with cast iron body, bronze impeller, mechanical seals, TEFCfan cooled type, squirrel cage high efficiency, IE3 class induction motor, base plate, mounting channel frame, accessories and fittingsmechanical seal,drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3-Phase AC supply. [a] Capacity :100 US GPM approx [b] Head :40 RM [c] Impeller: Bronzemetal[d] Approximate Motor Rating : 5 HP Note : Pumpsets will be arranged in 2Working+1Standby configuration. Neccessary plumbing work will be done accordingly.2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in hpmore than specified in tender, financial adjustment will be done through DO. |
| 32 | Supply, Installation, testing & commissioning of MS ERW Class \"C\" Conforming to IS: 1239 condenser water piping with all necessary fittings i.e. bends, tees, reducers, flanges pipe resting on half round wooden blocks, structural steel support etc complete all as specified.NOTEAll pipes, pipe support, structure shall be painted with two coats of synthetic enamel paint of color as per colour coding over one coat of red oxide primer with lettering and marking of flow in white paint |
| 33 | (a) 80 mm(30 mm thcik insulation) |
| 34 | (b) 60 mm dia (30 mm thcik insulation) |
| 35 | (c) 100 mm (30 mm thick insulation) |
| 36 | Supply, Providing and fixing in position the 60 mm bore dia Butterfly Valves with insulation as per specificationsand drawings: |
| 37 | Supply, Providing and fixing in position the 80 mm bore dia Butterfly Valves with insulation as per specificationsand drawings: |
| 38 | Supply, Providing and fixing in position the 80 mm bore dia Butterfly Valves as per specificationsand drawings: |
| 39 | Supply, Providing and fixing in position the 60 mm bore dia Butterfly Valves as per specificationsand drawings: |
| 40 | Supply, Providing and fixing in position the 50 mm bore dia Butterfly Valves as per specificationsand drawings: |
| 41 | Supply, Providing and fixing in position the 80 mm dia Balancing Valves with insulation as per specifications and drawings: |
| 42 | Supply and fixing in position the 60 mm dia Balancing Valves with insulation as per specifications and drawings: |
| 43 | Supply and fixing in position the 80 mm bore dia Y -Strainers with insulation as per specifications and drawings: |
| 44 | Supply and fixing in position the 80 mm dia non-return valves as per specifications and drawings: |
| 45 | Providing and fixing in position the 100 mm bore dia post strainer as per specifications and drawings: |
| 46 | Supply,Installation, testing & commissioning of 100 mm dial type bourdan pressure gauge of appropriate range and SS isolation valves & other fitting inchilled water, hot waterand condensor waterlinecomplete. |
| 47 | Supply, Installation, testing & commissioning of set of 150 mm dial type temperature gauge of appropriate range with thermowell and SS valves & other fitting in chilled water, hot water and condensor waterline complete. |
| 48 | S & F closed cell Class O, elastomeric nitrile rubber 19 mm thick thermal insulation for SA / RA ducts insulation with aluminum foil0.1 mm laminated on one side, having thermal conductivity not exceeding 0.037 W / mK atmean temperature of 20° C as per EN 12667, density (without the foil ) between 40 to 55 kg / cum applied using manufacturer recommended rubber based adhesivecomplete. |
| 49 | Supply & Fixing under deck insulation with resin bonded fibre glass wool conforming to IS :8913, density 24 Kg per cub meter, 60 mm thick, wrapped in 200 +20 GSM virgin polythene bags fixed to ceiling with metallic cleat 50x50x3 mm at 60 cm ctentre to centre and steel wire mesh of 12.5 mmx24 G wire complete. |
| 50 | Supply, Installation, testing & commissioning of square / rectangular supply air diffusers / grills of extruded powder coated aluminum sections with duly powder coated with aluminium volume control; damper, anti smudge ring and removable core complete. |
| 51 | Supply, Installation, testing & commissioning of square / rectangular return air diffusers / grills of extruded powder coated aluminum sections without damper complete. |
| 52 | Supply, Installation, testing and commissioning of fire and smokedamper of required size completeNOTE :- The fire dampers shall be motorised and spring return type so as to close damper automtically in event of power failure. Damper should be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU and damper complete. |
| 53 | Supply, Installation, testing and commissioning of actuiator with smoke fire censore of required size complete.NOTE :- The fire dampers shall be motorised and spring return type so as to close damper automtically in event of power failure. Damper should be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU and damper complete. |
| 54 | Supply, Installation, testing, balancing & commissioning of galvanized steel sheet (GSS) square / rectangular / round ducting for supply / return air fabricated from galvanized steel sheet of the following thicknesses having zinc coating of 120 gm per Sqm total on both sides complete with neprene rubber gaskets, elbows, splitters, vanes, hangers, structural steel supports as per IS: 655 with required scaffolding work to install the ducts at site complete all as specified.NOTE :- 1. GI sheet will conform to IS277.Rate quoted for ducting is inclusive of all accessories, hanging arrangement required for duct work 2. Before executig duct work, design and drawings will be get approved from Accepting Officer. |
| 55 | (a) 24 gauge galvanized sheet steel (0.63 mm thick) |
| 56 | (b) 22 gauge galvanized sheet steel (0.70 mm thick) |
| 57 | ©20 gauge galvanized sheet |
| 58 | Supply, Installation, testing & commissioning of MS Class \"C\" INSIDE PLANT ROOM/OUTSIDE PLANT ROOMconforming to IS:1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supportsclamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 Kg per cum, min thickness 50 mm thick, finished with 24 gauge aluminimum sheet over vapour barrier of 120 gm per Sqm polythene sheet with 50 mm overlap, tied down with lacing wire with type 3 grade 1 roofing feltstrip at joints incl making good to damages to building as per adjoining surface |
| 59 | 80 mm dia |
| 60 | 50 mm dia |
| 61 | 65 mm dia |
| 62 | Supply and fixing Cast iron butterfly valves 80 mm bore dia, complete all as specified and directed. |
| 63 | Supply and fixing Cast iron butterfly valves 50 mm bore dia, complete all as specified and directed. |
| 64 | Supply installation testing and commissioning of humidifier spray type complete all as specified and directed. |
| 65 | Supply, Installation, testing & commissioning of SS 304 shell type vertical electric hot water generator suitable for 30 KW heat output for hot water output with ater inlet at 45º C and outlet 50º C, working pressure 100 PSIg (tested for 350 psig pressure), having 50 mm thick insulation of resin bonded with fiber glasswool with 0.63 mm aluminium cladding, thermostat for individual step, digital thermometer for inlet & outlet pipes, pressure gauge with ball valve for inlet & outlet pipes, SCR based stepless linear controller, float switch, audio/visual alarm for low water level, auto vent audio/visual alarm for high temperature, pressure relief valve, door switch, safety thermostat, etc. complete as specified and directed. |
| 66 | Supply, Install, testing and commissioning centrifugal monoblock pump for pumping hot water from HWG to heating coil in AHU with energy efficient motor confirming to IS: 12615. The pump shall be suitable for given duty point[a] Impeller: Bronze metal, Shaft High Tensile steel, Pump Mpotor body : CI[b] Approximate Motor Rating: 3 HPNote : 1. Pumpsets will be arranged in 1Working+1Standby configuration. Neccessary plumbing work will be done accordingly2. Contractor will provide calculation of Head and HP of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO.3. Rate quoted is inclusive of foundation as per OEM recommendation |
| 67 | Supply install, testing and commisioning of electrical cable with electrical panelcomplete all as specified and directed |
| 68 | M & L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in Electric plate no.3 of SSR-2009 (Part-I) and testing on completion completeall as specified and directed. |
| 69 | M&L forEarthing complete with galvanised steel earth plate electrode 60×60cm.× 6mmthick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised iron strip of size 25X4 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point of made by gunmetal or bronze completeall as specified or indicated incl excavation and earth work and disposal of surplus soil incl 40mm GI tubing light grade and necessaryfitting for protection of copper strip incl laying of charcoal dust and common salt, PCC (1:3:6) type C-1 ( using 20mm graded stone aggregate) as in earth pit with 40x40x6mm MS Angle iron frame of required size 40mm thick and pit cover of well dressed dholpur stone 40mm thick 40x40cm size andwith well dressed and having of handle of made by 12mm MS Rod for lifting of pit cover,15mm thick plastering with CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia medium grade GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part-I (2009) and connected to earth test incl testing complete all as specified and directed. |
| 70 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal grond level with top edge of eathplate at a depth not less than 1.5 metre below normal ground level, earth plate surronded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts check nuts and washers made of galvanised iron and connected to main switch board or main control board or equipment with testing point to check the earthing values and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, and PCC chamber pit with PCC (1:3:6) Type C-1 using 20mm graded stone aggregate, 40cm x 40cmx40mm thick well dressed jodhpur stone by holing at middle including MS handle of made by 10mmdia MS rod, including excavation and earth work in any type of soil returning filling and disposal of surplus soil to a distance not exceeding 50m. all as specified and shown in electrical plate No 3 of SSR 2009 (Part-1) complete all as specified and as directed by Engineer-in-charge. |
| 71 | M&L for chemical earthing complete with Copper plate electrode of size 900mmx600mmx5 mm thick buried directly in earth pit not less than 4.7 meter below normal ground level and complete size of pit 1.6 meter x 0.61 meter x 5.10 meter earth plate connected to copper strip 32x6mm by means of copper/ brass nut, bolts earth strip protected with 40 mm bore light grade GI pipe from electrode, 20mm bore watering pipe, medium grade GI pipe including funnel wiremess providing alternate layer of 10 cm each charcoal salt and magnesium sulphate layer upto 1.2 meter and 2 Kg coper sulphate to be added around including excavation, returning in filling, removal of surplus soil to a distance not exceeding 50m, PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in earth pit with 40 x 40 x 6 mm MS Angle iron frame of required size 40mm thick and pitcover of well dressed dholpur stone 40mm thick 40x40m size with providing handle in center by ,aking hole and handle made by 12mm MS Rod in round/rectangle shape of handleof 100mm grip, 15mm thick plastering with CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia medium grade GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part-I (2020) and connected to earth test incl testing complete all as specified and directed. |
| 72 | Supply and Fixing the Porceleing insulator suitable for fixing the Aluminum strip/copper strip/GI Strip and fixing on roof/wall with screws and all as specified and direted. |
| 73 | Supply and fixing the PVC rigid conduit with accessories heavy duty concealed in walls etc for CCTV, AF net and LAWN connectors of size 25 mm dia with all connected accessories, complete all as specified and directed. |
| 74 | Supply and fixing the PVC rigid conduit with accessories heavy duty concealed in walls etc for CCTV, AF net and LAWN connectors of size 20 mm dia with all connected accessories, complete all as specified and directed. |
| 75 | Supplying and fixingHDPE water storage tank 10000 Litre capacity ISI marked cylindrical type with inlet, outlet, drain and over flow connections with float valves 25 mm dia pipe PVC ball of duly inter coneected connected to each other with 50 mm bore length not less than 1 RM including PCC foundation to be installed on suitable RCC / brick staging of 4 RM height complete all as specified. |
| 76 | Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, three phase 440 V, 50 Hz, made out of MS/ CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge s q u a r e perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1- 1.5 m/sec air velocity at floor level for door opening size 70\"\"x96\"\" along with sensor to operating commands as per human movement based type all as specified and directed. |
| 77 | M & L for sub main wiring with two run of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 4 Sqmm drawin in and including ERW stove enammelled rigid mild steel conduit not less than 20 mm dia with its accessories, surface type including one run of single core 4 Sqmm FRLSH PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor and connected to common earth dolly, complete all as specified and directed.NOTE : Two run of 04 Sqmm cable and one run of 04 Sqmm cable alongwith ERW steel conduit including its accessories shall be measured and paid as one unit |
| 78 | M&L for brick masonary valve pit of size 90 cm x 90 cm x90 cm (internal of chamber ) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 60 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 50 mm x 50 mmx5 mm with fixing arrangement , hinges and locking arrangement and painting two coat of synethetic enamel paint over a coat of red oxide primer on MS cover and frame , inlcuding necessary excavation and earth work in any type of soil , returning , filling in approved soil disposal of surplus soil to a distance not exc.50 mtr , 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation , brick work in cement motor (1:6) 15 mm thick plastering in cement mortoar (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as directed suitable for upto50mm dia. |
| 79 | M&L For taking down the DI Pipe line by excavtion and removing the rubber joint of existing pipeline 150mm Dia and keeping aside safely to re-use the same and all as specified and directed.Note : earth work like excavtion and returning, filling wiil be measured seperately under relevent item of Schedule. |
| 80 | Supply and layingductile Iron , Class “K-7” ,150 mm (6”) dia with rubber gasket spigot socket type including all fitting / specials etc completeall as specified and directed. |
| 81 | M&L For re-laying the DI Pipe line 150mm dia with new rubber joint and testing the leakage of water and all as specified and directed. |
| 82 | Supply only Rubber mat of 1mtrx2mtrx19mm. |
| 83 | Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board,400 Amp Copper bus bar insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use withangle iron 50 x 5 0 x 6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland.(a)MCCB 4 pole 250 amps 35 KA -01 NO (INCOMING)(b) On-Load change over switch 160 Amp 4pole 415 volts-01 No(c )MCCB 4 pole 160 amps 35 KA-02 NO(OUTGOING) (d ) MCCB 4 pole 63 amps 25 KA-01 NO(OUTGOING) (e ) MCCB 4 pole 40 amps 25 KA-03 NO(OUTGOING) (f ) MCB SPn 40 Amp 10 KA -02No (out going)(g )Ampere meter (digital type)with selector switch - 01 No( h)Volt meter (digital type) 0-400 volts with selector switch - 01 No(j )Indicator lamp RYB (3 Nos) - 01 Set(k )CT\"s of suitable cap |
| 84 | M&L For cuttung /modification of existing LT Panel to Fixing the MCCB 250Amp 4 pole and making hole and welding/ cutting the outer cover as per frame size of MCCB and all as speified and directed by Engr-in-Charge. |
| 85 | Supply and Fixing Air circulator fan metal body , Wall Mounting type 230 Volts , 50Hz and Oscillating 450mm Sweep with fixinh on wall/pillar alongwith mounting clamp and all other accessories. |
| 86 | Supply and Fixing in replacement of loop-in/loop-out box of outer size 160x200x98mm made out of FRP body (hot mulded type) with IP-63 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 50 Amp rated 2 pole connector suitable to insert the cable size 25 Sqmm-01 No,with neutral linkand din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on PCC/Brick work pillar including cable glands, aluminum lugs/thimbles for incoming and out going cales andall as specified and directed. |
| 87 | Supply and laying the slottedHDPE pipe of double wall courrigated type 50/38mm diafor protection of LT UG cables size 10x2 core to 35x3.5 Core under the trench with jointing rubber in between two lengths of length 6mtrs and all accessories and all as specified and directed. |
| 88 | Supply and laying the slotted HDPE pipe of double wall courrigated type 110/90mm diafor protection of LT UG cables size up to 300 Sqmm 3.5 Core under the trench with jointing rubber in between two lengths of length 6mtrs and all accessories and all as specified and directed. |
| 89 | Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Disel Engine driven Generating set of capacity 100KVA, CPCB-IV ,water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum.The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe, battery of adequate capacity as per OEM recommendations for self starting purpose complete and suitable for conditions prevalent at Agra (capacity of engine, alternators shall worked out taking allderating factors into consideration) including PCC foundation 1:2:4 type B1 (using 20 mm graded stone aggregate) size 3.5mtr x 2mtrs anti-vibration pads complete all as specified and directed. The DG set shall be fitted with retrofitting of emission control devices (RECD) as per NGT normsincluding all feature to comply with latest CPCB guidelines and comprising of following components:- |
| 90 | (a).DIESEL ENGINE :-Diesel engine 1500RPM, direct injection, multi cylinders, four stroke, conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 100 KVA at outdoor atmospheric conditions at Agra ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:-(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type(iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level(v) Radiator cooling (vi)Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel hoses (ix) Fuel injection pump (FIP)(x) Fan and water pump assesembly (xi) Lub oil filter and pump(xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid battery as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc01 set |
| 91 | (xiii) Engine safety shut down system against lowoil pressure and high water pressure. (xiv) Exhaust gas driven turbo charge(xv) Oil filter (xvi) Lub oil cooler(xvii) Engine main manual with spare part list(xviii) Suitable designed acoustic enclosure as per CPCB regulations(xix) Any other item not included / specified but is a standard design of the manufacturer. |
| 92 | (b). Engine insttrument panel : Engine instrument panel shall comprising of thefollowing:-(i) Starting on /off switch.(ii) water temp auge. (iii) Hour meter cum RPM indicator(iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure.(viii) Any other item not included/specified but is a standard design of the manufacturer. |
| 93 | (c ). ALTERNATOR shall be self excited, self regulated, brush less for 100KVA continuous operation at the speed of 1500RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition. |
| 94 | Bottom mounted (or as per manufacturer design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continuous operation inside canopy withfuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed. |
| 95 | (d). Bypass arrangement by providing separate indoor panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 160 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter.(ii) Any other item not included/ specified but is a standard design to the manufacturer. |
| 96 | (e). AMF CONTROL PANEL: Supply, fabricating and testing of factory made/fabricated cubical automatic main failure panel indoor type with degree of protection IP-42 conforming to IS-2147, suitable for 100KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated copper bus bar,contactors of adequate rating for auto transfer of main/DG supply, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories all as specified and directed :- (i) Master switch for auto/manual/reset/off-01 No.(ii) Digital type multifunctional meter for ampere, voltage, power factor, frequency etc -01 No. (iii) Push button start, stop, reset-01 No.(iv) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure.(v) Battery charger connected to load.(vi) Transformer of adequate rating.(vii) Ractifiers(viii) DC ampere meter and voltmeter.(ix) Fault accept / reset push button. (x) Set of relays and contactor140 Amp suitable for 100KVA DG Set for automatic start and automatically shut down of suitable rating and capacityand 2 Nos MCCB 4 pole, 160 Amp, 25 KA, 4 pole thermal adjustable type of range 70-100% fixed on main supply and DG set supply. (xi) Make of AMF control panel shall be as per OEM recommendations. |
| 97 | Supply and laying the slotted HDPE pipe of double wall courrigated type 110/90mm diafor protection of LT UG cables size up to 300 Sqmm 3.5 Core under the trench with jointing rubber in between two lengths of length 6mtrs and all accessories and all as specified and directed. |
| 98 | S & F wall mounted type LED light fitting batten type complete with LED 1x 20watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twin coretwisted flexible copper conductor cable complete all as specified and as directed. |
| 99 | S & F factory made epoxy powder coated distribution board VTPN DB 4 ways coniform to IS 8623-1, IEC-61439-1&3 metal double door ,IP54 with acrylic top coverfabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including with insulated vertical phase bus bars, neutral bar, stranded DIN rail, earth bar,colour coded interconnectingwire setand cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| 100 | S & F factory made epoxy powder coated distribution board VTPN DB 6 ways coniform to IS 8623-1, IEC-61439-1&3 metal double door ,IP54 with acrylic top coverfabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including with insulated vertical phase bus bars, neutral bar, stranded DIN rail, earth bar,colour coded interconnectingwire setand cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail