Tender For Special Repair In Bldg No P-35 (Or Living) And P-39 (Jcos Living) At Old Ilp Loc Engr Regt Under Ge Missamari; 1 Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) 2 Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) 3 S&Ffor 165 x 60 mmPressed steel frames for doorwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed 4 S&F for 105 x 60 mmPressed steel frames for doorwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed 5 M&L for cement concrete 1:3:6, type-C-0 (12.5 mm graded stone aggrgate) as in filling in steel frame/roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed. 6 S&F for 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides. 7 S&F for 35 mm thick 2nd Class hardwood Glazed andskeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars),edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified inSSR Part-I, Section 8, Clause 8.24 (a) supplied and fitted to chowkats 8 S&F for Solid PVC Door Frame of size 50 mm x 95 mm made out of 5mm wood grain colour PVC Sheet reinforced with MS Square etc. 9 S&F for Factory Made Solid PVC Moulded Door Shutter with Particle Board Core, 28 to 30mm thick (stiles) with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed. 10 S&F for powder coated aluminium frame for doors, windows, ventiletors with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.(minimum thickness of poweder coating 50 micron). 11 S&F powder coated aluminiumwindow/ventiletor shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type-B-21, 100 mm long ( 2 No) suitable handle 1 No complete all as specified and as directed (thickness of powder coating not less than 50 micron). 12 S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165 13 S&F in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified. 14 S&F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beadsin squares not exceeding 0.5 Sqm in each pane 15 S&F 4 mm thick frosted glass, ordinary quality and glazing with wooden beadsin squares not exceeding 0.5 Sqm in each pane 16 S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 17 M&L in repairs 18/19 mm thick pre-laminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in Wooden frame work in piano hinges complete all as specified and directed. 18 M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm gradedstone aggregate) as in hold fast. 19 S&F 100 mm long extruded aluminium alloy with galvanised mild steel Butt hinges and fixed type B-21. 20 S&F 100 mm long medium weight, cold rolled mild steel Butt hinges and fixed. 21 S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. 22 S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section 23 S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. 24 Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises. 25 Glazed ceramic coloured tiles in vertical surfaces 300 x 600 x 7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl plaster 10 mm thick plasterin CM 1:4 . 26 M&LNon-skid Ceramic tiles 7 to 8 mm thick (square/rectangular) of size 300 x 300 mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. 27 M&LNon-skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) 600 x 1200 mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. 28 Demolition of stone slabs tiles of any description or thickness in floors apronslaid bedded and pointed in any morter etc 29 M&L for Kota stone slab flooring of 20-25 mm thick over cement screed jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete incl 20 mm thick screed bed 1:6 CM in floors. 30 M&L for Kota stone slabof 20-25 mm thick in riser of steps, skirting, dado over cement screed jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete incl 10 mm thick screed bed 1:4 CM in floors. 31 Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) 32 M&L Reinforced cement concrete Nominal mix for (B1) 1:2:4 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like 33 Form work to side & soffits of floor or roof beams, slab, lintels & similar works. 34 M&L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etc binding with mild steel wire not less than 0.90 mm dia (annealed) complete all as directed and specified. 35 Demolition of un- reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) 36 M&L for 75 mm thick cement concrete as in plinth protection/ path etctype C-2 1:3:6 (using 40mm graded aggregate) finishing concrete surface even and smooth with using extra cement complete all as specified and directed. 37 Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water etc. 38 Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish complete all as specified and directed. 39 M&L for half brick work burnt modular bricks built in cement mortar 1:4 straight or curved on plan exceeding 6mtr mean radius and all as directed. 40 M&L for brick work with burnt modular bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius and all as directed. 41 M&L for 15mm thick plaster in on fair faces of brick work or concrete surface in cm (1:4) with WPC @2% by weight of cement face of conc work to wall surface and the surface is finished even and smooth without using extra cement.WPC paid separetely 42 M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth. 43 M&L rendering 5mm thick of cement plaster 1:3on concrete surfaces of ceiling finished even and smooth (without using extra cement). 44 Removing complete existing treatment incl PCC pedding of roof surfaces by picking, sweeping clean and washing down with water to remove dust etc. and crushing neat cement slurry with 03 Kg of cement per Sqm and rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 (Internal water proof compound measured seperately) including25 mm thick cement concrete PCC Type B0 1:2:4 using 12.5 mm graded aggregate and applyingAPP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric weight not less than 150 gms/sqm and on primed surface by forced applicationincluding coating the surface with water based bituminous primer blow bitumen of 85/25 or 90/15 at 1.2 Kg/Sqm both at bottom and top of the membrance and finally finished with one coat of bitumenous aluminium paint at 100 gm per sqm complete all as specified. 45 Taking down rain water pipes inculding all fittings any size and pattern 46 S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. 47 S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls. 48 S&F 110 mm bore PVC (SWR) bends of any radius. 49 S&F 75 mm bore PVC (SWR) bends of any radius. 50 S&F 110 mm bore PVC (SWR) junction single (Single `T) equal or unequal with access door 51 S&F 110 mm bore PVC (SWR) Vent Cowl 52 M&L 75 mm bore for PVCfloor trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 53 M&L 75 mm bore for PVCNahani trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 54 Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store 55 Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store 56 Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store 57 Supply and laying 15 mm dia bore steel tubes,mediumgrade galvanised, with all fitting an fixed complete to walls and ceilings or laid in floors complete all as specified 58 Supply and laying 20 mm dia bore steel tubes,mediumgrade galvanised, with all fitting an fixed complete to walls and ceilings or laid in floors complete all as specified 59 Supply and laying25 mm dia bore steel tubes,mediumgrade galvanised, with all fitting an fixed complete to walls and ceilings or laid in floors complete all as specified 60 S&F in repairs 10 Ltrs capacity PVC flusing cistern low level slimline or equivalen make / model with all accessories. 61 S&F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including cutting for and pinning ends of brackets or erecting stand and waste pipe as requred complete all as specified an as directed 62 S&F in repairs Vitreous China squatting pan Orissa patern size 630 x 450mm white with integral foot rest (Excluding flushing cistern & flush pipe) 63 S&F in repairs Vitreous EWC size 580 x 440 mm white with includig P or S traps. 64 S &F in repairs Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) 65 PVC connection 15 mm bore450 mm long 66 S&F in repairs 15mm bore angular/ concealed stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. 67 S&F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. 68 S&F in repairs 15 mm bore chromium plated bib taps concealed type, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. 69 S&F in repairsTowel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) 70 Preparation of old paintedsteel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of synthetic enamel paint. 71 Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer over applying two coat of synthetic enamel paint. 72 Material & Labour for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @2.20 litre/10 sqm over new surface over 1 mm thick wall care putty. 73 M&L for Complete removal of old surfacefor preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface over 1 mm thick wall care putty. 74 M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper including one coat of chalk whiting on plastered surface to prepara-tory to distempering complete all as specified and directed over 1 mm thick wall care putty. 75 M&L for complete removal of old surfaces of walls and applying two coats of acrylic distemper including one coat ofchalk whiting on plastered/putty surface to preparatory to distempering complete all as specified and directed over 1 mm thick wall care putty. 76 Preparing new surfaces of ceilings by brooming down or by steel wire brushing and applying three coats of white wash. 77 M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash complete. 78 Dismantling PVC/RCC water tanks and removing to store exc 500 & not exc 1000 ltrs 79 S&F 1000 Ltrs capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed. 80 M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and even and smooth without using extra cement including mixing of water proofing compound wherever required for floors and sides of wall in sunken floorsNote : Water proofing compound will be measured separately 81 M&L applying one coat of NITTO proof to sides and bottom of floors to sunken floors. 82 M&L for plain cement concrete Type E2 1:5:10 (using 40mm graded granite stone aggregate) in foundations, filling and mass concrete. 83 M&L for plain cement concrete Type B2 1:2:4 (using 40mm graded granite stone aggregate) in floor sub base and mass concrete. 84 M&L for granite of any type 20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 20 mm thick screed bed 1:6 CM in floors. 85 S&F in repairssinks with drainage board made of stainless steel lmm thick kitchen or laboratorywith plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed 86 Supply only Integral water proofing compound 87 Taking down carefully existingunserviceable copper/ aluminiumpoint wiring (light,call bell, two way, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators,bracket light fittings and making goodto the disturbedsurface complete all asdirected by Engr-in-Charge. 88 Taking down the existing unservicable main switch /change over / cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified by Engr-in- Charge. 89 Taking down carefully unsv aluminium submain wiring of any type /loc includingconduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge. 90 Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles all as specified and directed. 91 M & L for Point wiring with 1.5 Sq mm copper conductor single core FRLSH PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC Concealed conduit and its accessories of suitable size, high grade ISI markedin walls /roof and PVC boxes of suitable size including fixing/grouting sunken/ surface as per site requirement for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor FRLSH PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for :(a) One light point controlled by one, one way switch 5 Amps 92 (b) One ceiling fan / exhaust fan point controlled by one , one way switch and regulator 93 (c) One 3 point 5 Amps socket outlets point controlled by one switch on the same board 94 (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board 95 Description all as per item No 91 here in before but for one light point controlled by one, two way switch 5 Amps 96 All as per item No 91 above but with two run of 2.5 sqmm multi stranded Single core copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with one run of FRLSH PVC 2.5 Sqmm multi standard insulated sheathed copper wire as earth continuity conductor along with wiring and connecting to the common earth dolly on independent board. 97 S & F Switch piano (White)flush type single pole one way, 6 amps, 230 Volts.complete all as specified and directed. 98 S & F switch piano (White)single pole flush type, two way, 6 amps, 230 volts.complete all as specified and directed. 99 S & F Socket outlet (White)2 in 1, 5 pin, 5 Amps complete all as specified and directed. 100 S & F Switch socket combination(White)flush type multipurpose 5 pin 5 Amps two in one , 230volts complete all as specified 101 S&F Switch socket combination (White)2 in 1 5/6 pin, 15 Amp flush type universal. 102 S&F ceilling rose (White)three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specified 103 S & F ceiling fan regulator (White)step type 2 Module, flush type heavy duty suitable to work on 230 Volt AC supply complete all as specified. 104 S & FLamp holder (White)with insulated body, with back plate suitable for batten fittingscomplete all as directed. 105 S & F LED ADORE 10 W B22 CDL 5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. 106 S & F sheet metal enclosure MCBVTPN 08 wayDouble door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for4 Pole MCCB 200 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed. 107 S & F MCCB 4 Pole 415 volts 200Amps with thermal - magnetic release with breaking capacity 25 KA and with adjustable overload setting complete all as specified. 108 S & F sheet metal enclosure MCB DBTPN 4 way with 200 amps rated bus bar 415 volts double door with locking system complete grouted on walls complete all as specified and directed. 109 S & F sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door withlocking system complete grouted on walls complete all as specified. 110 S & F sheet metal enclosure MCBDBSPN4 way with 200 Amps rated bus bar 240 volts double door withlocking system completegrouted on walls complete all as specified. 111 S & F MCBFP415 volts suitable for fixing in MCB TPN DB of capacity 63 amps complete all as specified and directed. 112 S & F MCBSPN230volts suitable for fixing on MCB DB of capacity 32Amps , 10KV , C Cuvrecomplete all as specified. 113 S & F MCB SP, 240 volts, 6-32A Amps 50 Hz ,confirms to IS/IEC 60898 Breaking Capacity of 10 kA, B-curve, complete all as specified and directed. 114 Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 115 S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as directed by Engineer-in-Charge. 116 Excavation in trenches n exc 1.50 m wide andn exc 1.50 m depthin soft /loosesoil andgetting out for lying of cable and errection pipeetc complete all as directed. 117 Returning, filling in, trenches insoft /loose soilincluding spreading, leveling, watering and well ramming in layers not exc 25 cmcomplete all as directed. 118 Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting pointcomplete all as directed. 119 M & L sand cushioning in trenches for cable protection with coarse sand laid dry in trenches with uniform thickness including consolidation complete all as directed. 120 Supply & Laying well burnt brick , locally available best quality (sub class B bricks) laid in trences perpendicular to UG Cable protection complete all as specified. 121 Supply & Laying XLPE LT heavy duty UG Cable of size 95 Sqmm 3.5 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. 122 Supply & Laying XLPE LT heavy duty UG Cable of size 50 Sqmm 3.5 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. 123 S & F GI Tubing medium grade of size 40 mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed. 124 S & F GI Tubing light grade of size 50 mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed. 125 S & F GI Tubing light grade of size 80 mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed. 126 Taking down ceiling fan/ Exhaust Fan of any sweep, keeping with safe custody and refixing the same with new fan hook andreplacement of unsv core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal over hauling the fan complete all as specified and as directed. 127 M&L for replacement Sub main wiring4 x 6 Sqmm multi-strand FRLSH PVC insulated copper conductor unsheathed cable including concealed conduitand continuous earthwire of FRLSH PVC insulated multi-strand copper conductor of size 6.0 sqmm complete all as specified and directed. Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. 128 M & L Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheated (FRLSH) multistranded 1100 volts grade with copper conductor duly cutting chases on walls anddrawn through and including non-metalic Rigid PVC Conduit ISI marked and itsaccessoriesincluding one run of single core 6.0 sqmm PVC insulatedunsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board with proper copper lugs and making good disturbed surfaces and matching with existing colour complete all as specified and directed. 129 Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item. 130 Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GIearth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mmbore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wiremesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I. 131 Supply and Fix Cable end termination kit for LT1.1 KV Cable for Cable 70 Sqmm 3.5 Core cable complete all as specified and directed . 132 Supply and Fix Cable end termination kit for LT1.1 KV Cable for Cable 50Sqmm 3.5 Core cable complete all as specified and directed .