}

Tender For Special Repair To Kitchen No 1 At Cadets Mess At Nda Khadakwasla., khadakwasla-Maharashtra

Military Engineer Services has published Tender For Special Repair To Kitchen No 1 At Cadets Mess At Nda Khadakwasla.. Submission Date for this Tender is 22-09-2025. Building Work Tenders in khadakwasla Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

51139676
Tender For Special Repair To Kitchen No 1 At Cadets Mess At Nda Khadakwasla.
Tender
Indian
Maharashtra
Khadakwasla
22-09-2025
BootCamp

Tender Details

Tender For Special Repair To Kitchen No 1 At Cadets Mess At Nda Khadakwasla.; 1 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc laid beded & pointed in any mortar etc all as specified and as directed 2 M&Lfor 18 to 20mm thick granite (of any type) work (table rubbed 7 polished ) in window door cills/jambs, platformlike in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade with granite. over 20 mm thick screed bed in CM 1:4 including complete all as specified and directed 3 M&L for 18 to 20 mm thick Granite(of any type) work (table rubbed and polished) in Jet Black or any colour leather finish granite for top & Sides of Platform, steps tread, skid surface, Wash basin topetc. and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade over 15mm thick screed bed in CM 1:4 etc complete allas specified and as directed. 4 M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete etc complete allas specified and as directed. 5 M&Lfor Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 20mm thick screed bed in CM 1:4 etc complete allas specified and as directed. 6 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situationscomplete allas specified and as directed. 7 Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete allas specified and as directed. 8 M&L for glazedcoloured ceramic joint freetiles 300x450x8-10 mm thick on vertical surfaces such as skirting/ dado laid over 10 mm thick backing coat in CM (1:4), set and jointed with polymer modified tiles adhesive (white colour) and pointed in white or coloured cement to match all as specified and directed 9 Demolition of cement concrete in ground floor & pavings of any description and in any position complete allas specified and as directed. 10 M & L for plain cement concrete 1:3:6type C2 (using 40mm graded stone aggregate) as in sub base of floor or simillar work complete allas specified and as directed. 11 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard / dense soil.etc complete allas specified and as directed. 12 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete allas specified and as directed. 13 Removing excavated soil material exc. 250m and n.exc 500m depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed . 14 M&L for precast cement concrete blocks masonry with solid blocks of PCC (1:3:6) type C1 (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed)exc 10cm in width and set and jointedin Cement Mortar (1:4) etc complete all as specified and directed 15 M&L for Providing precast cement concrete solid building blocks Type C-1, 1:3:6 using 20mm graded stone aggr or slabs n.exc 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls and set and jointedin Cement Mortar (1:4) etc complete all as specified and directed 16 Taking down cement plaster on brick or stone walls, ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed 17 M&L for checken wire mesh fixed to wall surface with nails etc before rendering etc complete all as specified and directed . 18 M&L for rendering 10 mm thick in CM 1:4 finising even& smooth without using extra cement on fair faces of brickwork or concrete surfaces all as specified and directed. . 19 M&L for rendering 10 mm thick in CM 1:4, with sagol finish on plastered surface of internal drain fair faces of brickwork or concrete surfaces all as specified and directed. 20 M&L for Providing and fixing stainless steel (Grade 304) made of hollow tube or Sheet for drain /Duct /grating /drain with covermadeofchannels, plates,angles etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the ductwith necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the wall and floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge,Note: For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. 21 M&L for core cutting of 150mm dia, n exc 600mm deptth in stone wall and making good disturbed surfaces and filling the remaining area with cement concrete (1:2:4)type B-1 using 20mm graded stone aggregate all as specified and directed 22 M&L for RCC M-20 (design mix) using RMC as in basement Slabsusing 20 mm graded stone aggr) supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc all as specified and directed. 23 M&L for RCC 1:1 1/2:3 (M-20) (Nominal mix ,( using 20 mm graded stone aggr) as in drain Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttressesetc all as specified and directed 24 M&L for Formwork to faces of flat rough finfished surfaces of concrete walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter etc all as specified and directed . 25 M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc all as specified and directed 26 M&L for TMT Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc all as specified and directed 27 Taking up or down steel tubing and connections incl cleaning for re-fixing or removal to stores, 15mm dia pipes complete all as specified and directed 28 Taking up or down steel tubing and connections incl cleaning for re-fixing or removal to stores, 20mm dia pipes complete all as specified and directed 29 Taking down up or down steel tubing and connections incl cleaning for re-fixing or removal to stores , 25mm dia pipes complete all as specified and directed 30 M&L for 15mm bore GI Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed . 31 M&L for 20mm bore GI Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed . 32 M&L for 25mm bore GI Tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed . 33 S&F in repairs of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors 16mm outer dia including all fittings like elbow, tees, sockets, union, nipple, adaptor etc complete all as specified and directed . 34 S&F in repairs of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors 20mm outer dia including all fittings like elbow, tees, sockets, union, nipple, adaptor etc complete all as specified and directed . 35 S&F in repairs for providingangular stop cock cast copper alloy fancy type screwed down high pressure with cruntch or butterfly handle, screwed both ends for iron pipe or for union and fixed for 15mm bore of pipe with long shunk and cup (concealed type) all as specified and directed 36 S & F in repairs for long body bib cock, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to pipe etc complete all as specified and directed. 37 S&F in repairs 150mm Grating SS Square fittings made in two parts for smell and mosquito proofing with minimum 25 mm water seal of PTMT (minimum wight 85 gms) all as specified and directed 38 S & FPVC connections 15 mm size with PTMT nuts of length 900mm etc all as specified and directed 39 S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm etc., complete all as specified and directed 40 M&L for prepration of new concrete surface and applying two coat of Synthetic enamel paint over one coat of priming paints plaster coat on wall exc 10 cm width or girth etc complete all as specified and directed 41 M&L for complete removing of existing treatmenton ceiling and applying two coats of Synthetic enamel paint over one coat of primer on ceilings exc 10 cm width or girth etc complete all as specified and directed 42 Demolition & breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including bed concrete internal dia of pipe 250mm and removal of demolished materail out of MoD land complete all as specified and directed. 43 M&L for 250mm bore Reinforced Cement Concrete pipes, class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I) as specified in particular specification clause No.12.14 laid and jointed complete all as specified and directed 44 M&L for PCC (1:3:6), type C-2, using 20mm graded stone aggregate as concrete bed to drain pipes of 250mm bore including packing under and haunching against the sides of pipes, after they are laid and tested complete all as specified and directed 45 M&L for Broken glass coping @ 3 Kg per Sqm bellow the floor for protection of Rat entry inside kitchen etc complete all as specified and directed 46 Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed 47 S&F factory made 35mm thick 1st class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, supplied and fitted to chowkats, etc complete all as specified and directed 48 S&F 150mm Double action spring hinges, mild steel with steel wire spring, stove enamelled, black etc complete all as specified and directed 49 S&F extruded SS plate handle, fabricated type polished bright,175mmlong of shape ascomplete all as specified and directed 50 S&F decorative type SS sliding door bolt 300mm long with sand or die-cast brass hasp,staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed etc complete all as specified and directed 51 S&F SS barrel tower bolt, heavy 450mm long, with cast or sheet barrel and rolled or cast bolts and fixed etc complete all as specified and directed 52 M&L for prepararion of new wood surfaces and applying two or more coats of Melamine wood polishing up to desired finished by mechanical method (gun spray)of any description width or girth with wood fillar if necessary to fill the crack and holes etc complete all as specified and directed 53 Taking down Aluminium chowkat including shutters of any description exc 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed 54 S&F, Powder coated (minimum thickness of powder coating 50 mm micron) aluminium frame & shutter for door, window and ventilator including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, hinges, tower bolt, etc complete all as specified and directed . Note :- Floor door spring & sheet glass shall be measured and paid seperately. 55 S&F, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed 56 S&F 4.00mm thick sheet glass, ordinary quality and glazing with rubber packing in squares exceeding 0.5 Sqm in each pane complete all as specified & directed 57 Taking down exiting copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed 58 M&L for point wiring in and including new In stove enamelled steel conduit medium grade with the help of multi-strandedunsheathed FRLSH copper cable 1.5 sqmm 650/1100Vconforming IS:3419 -1988 adhereing to colour codeincluding earth wire of the size 1.5 Sqmm green colored with modular steel or cast iron terminal boxes and modular cover plates as required at site including making good the distrubed surfaces and matching it with existing surface for the following :- (a)One light/Fan point controlled by one way switch 6 Amps 240 volts 59 (b) One 3 pin socket outlet, 5/6 Amps on the same board with other switches 60 (c) One 3 pin socket outlet, 5/6 Amps, independent 61 (d) M&Lpoint wiring for one 3 pin socket outlet 15 Amp Independent with 4 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable in and including PVC conduit not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLS cable size 4 sq mm copper conductor as earth wire to common earth dolly all as specified. 62 S&F modular switch 1 way 10 A 1 module complete all as specified and directed . 63 S&F Modular socket 6 A 2/3 Pin2 module complete all as specified and directed . 64 S&F modular switch 1 way 16 A 1 module complete all as specified and directed . 65 S&F Modular socket 6 A/16A 2/3 Pin2 module complete all as specified and directed . 66 S&F modular fan regulator, 2 module, suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed 67 S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body complete all as specified and directed . 68 S&F in replacement of Industrial LED batten 40 W with THD <10%.Surface/Suspended LED batten, CRCA housing for efficient heat dissipation with built-in electronic driver havingPerfect for lighting large areas like Kitchen & general purpose spaces including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified.Make-Havells -STOUTMINI1200BS40WLED865SPCWHor eqivalent make as mentioned at list of makes in PS 69 Dismantling and refixing the ceiling fan/Exhaust Fan complete of any type and size , cleaning, servicing, painting greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete spray painting complete all as specified and directed.Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted. 70 S & F Anchor Bolt on the RCC roof Drill holes at the marked locations using a masonry drill bit. Ensure the holes are deep enough to accommodate the entire length of the anchor bolts.Place the mounting bracket over the anchor bolts and secure it by tightening the nuts with a wrench. Ensure the bracket is firmly attached and level.Ensure all connections are secure and the fan is stable complete all as specified and directed . 71 M&L for repalcing the down rod of ceiling fans with 5 feet GI ceiling fan hanging down rod with necessary clamp accessories complete all as specified and directed 72 Taking down exiting copper/aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed 73 M&L forsub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 2.5 Sqmm , 1100 Volts grade in and including In Steelconduit medium grade with all fitting & other accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed.Note: Two runs of 2.5 Sqmm cable with 01run of 2.5 Sqmm earth wire along with Steelconduit medium grade shall be measured as one RM 74 M&L forsub main wiring with two single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including In Steelconduit medium grade with all fitting & other accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 04 Sqmm cable with 01run of 4 Sqmm earth wire along with Steelconduit medium grade shall be measured as one RM 75 M&L forsub main wiring with Two single core PVC insulated FRLScables with stranded copper conductors 6 Sqmm , 1100 Volts grade in and including In Steelconduit medium grade with all fitting & other accessories and copper cable 6 sqmm continuous earth wirecomplete all as specified and directed. Note: Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along withSteelconduit medium grade shall be measured as one RM 76 Supply and fix in replacement sheet metal enclosures with double pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc complete all as specified and directed Make: Legrand Cat part: 5078 10 or eqivalent make as mentioned at list of makes in PS 77 Supply and fix in replacement sheet metal enclosures with double pole MCB 20 Amps with a two pin and earth plug and socket complete with all accessaries etc complete all as specified and directed. Make: Legrand Cat part: 5078 10 or eqivalent make as mentioned at list of makes in PS 78 S&F in replacement of factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, and MCB as outgoing with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified and directed Note: MCCBs and MCBs will be measured and paid seperately under respective Sch A item in the schedule 79 S&F in replacement MCB DB 12 way SPN Double door sheet metal enclosure factory made suitable for MCB DBs 240 volts,concealed in wall complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site complete all as specified and directed. .Note - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced. 80 S&F replacement MCB DB 02 way SPN singledoor sheet metal enclosure factory made suitable for MCB DBs 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at site complete all as specified and directed 81 S&F MCB DB 04 way SPN single door sheet metal enclosure factory made suitable for MCB DBs 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and existing circuits complete as reqd at sitecomplete all as specified and directed 82 S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , B curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed 83 Supply and fix in replacement of C Curve MCB SPN 40 Amps working on 240 volts, 50 HZ,10 KAcomplete all as specified and directed 84 Supply and fix in replacement of C Curve MCB SPN 32 Amps working on 240 volts, 50 HZ,10 KAcomplete all as specified and directed 85 S&F MCB TPN 40 Amps 415V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed. 86 S&F in replacement of MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed 87 Taking downthe electric chimney Carefully remove the screws securing the chimney to the wall or cabinet. Gently pull the chimney away from its mount, ensuring not to damage any surrounding structures.Detach any additional accessories such as filters, duct covers, or lighting fixtures. Clean and store these parts if they are to be reused.Patch any holes or marks left on the wall or ceiling. Ensure all tools and removed parts are safely stored complete all as specified and directed. 88 Supply, laying and testing in replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed 89 Supply, laying and testingin replacement ofcable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core complete all as specified and directed 90 Supply, laying and testingin replacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Copper conductor of size 10 sq mm 5 core complete all as specified and directed 91 Supply, laying and testingin replacement ofcable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Copper conductor of size 4 sq mm 3 core complete all as specified and directed 92 Supply, Installation, Testing & Commissioning ofWire Meshgalvanized cable trays with a 50 mm x 200 mm mesh configuration along with all necessary accessories. Wire Mesh Cable Tray galvanized after manufacture in accordanceTrays should comply Standard EN ISO 14 61: at least 550 h of SST. The electrical resistance of the joints must not exceed 50 mΩ and must be tested in accordance with the procedure described in the standard IEC 61537. Assemblies with specific fire-resistant properties must have an E30-E90 certificate issued by an approved laboratory in accordance with the tests described in the standard DIN 4102-12. The wire cable tray short-circuit resistance must be tested by an independent laboratory. For the purpose of assembling the various wire cable tray, only fast coupling systems or screw-based (CE25/CE30) systems must be used. These must be designed, mechanically tested and supplied by the wire cable tray manufacturer.The electrical resistance of the joints must not exceed 50 mΩ and must be tested in accordance with the procedure described in the standard IEC 61537.Rod dia must be from 3.9mm to 5.9mm for different sizes. The loading capacities of the brackets and the hanger torques must be tested in accordance with the standard IEC 61537. The tray along with the accessories should not contain any metallic burrs to avoid damaging of cable insulation.CF54/200GC CABLE TRAY GC,CONSOLE CSN 200 GC,KITASSTRDC COUPLING KIT complete all as specified and directed, 93 S&F in replacement offactory made epoxy powder coated Sub Main Distribution Board (SMDB) with MCCB as incomer and MCCBs as outgoing devices SMDB 400 12 way DD ME OPTIUM F-I/c & TP F1 O/G-1 Nos, SMDB 400/630 cable alley 12 DD-1 Nos, bottomcable unit DD SMDB with F1 & F2 O/G-1 Nos,Corner unit DD-1 Nos,315 A 4P 26 KA MCCB-1 Nos,100A 3p 16 KA MCCB-10 Nos with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specified 94 M&L in replacement of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc complete all as specified and directed 95 M & L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed

Key Value

Document Fees
INR 500 /-
Tender Value
INR 48.34 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail