}

Tender For Special Repair To Bldg No P-52 At Cgdhq-1 Under Ge (I) Cg Porbandar, porbandar-Gujarat

Military Engineer Services has published Tender For Special Repair To Bldg No P-52 At Cgdhq-1 Under Ge (I) Cg Porbandar. Submission Date for this Tender is 29-09-2025. Building Work Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

51138782
Tender For Special Repair To Bldg No P-52 At Cgdhq-1 Under Ge (I) Cg Porbandar
Tender
Indian
Gujarat
Porbandar
29-09-2025
BootCamp

Tender Details

Tender For Special Repair To Bldg No P-52 At Cgdhq-1 Under Ge (I) Cg Porbandar; 1 Schedule A B/R 2 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified & directed by Engineer-in-Charge. 3 Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc., complete all as specified & directed by Engineer-in-Charge. 4 Taking down chowkhat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 sqm in each panel, complete all as specified & directed by Engineer-in-Charge. 5 Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 sqm but not exceeding 4.0 sqm in each panel, complete all as specified & directed by Engineer-in-Charge. 6 Demolition of Concrete of any description and in any position not otherwise specifically provided, complete all as specified & directed by Engineer-in-Charge. 7 Dismantling/ Demolition of brick work or stone masonry or RCC Pre cast Jali & Jafari built in cement mortar including all quoins, arches, pillars, etc., complete all as specified & directed by Engineer-in-Charge. 8 Taking down cement plaster on stone wall including racking out joints, hacking for key scrubbing with water etc., complete all as specified & directed by Engineer-in-Charge. 9 Taking up or down 15/16mm bore dia, steel tubing & connections including cleaning for re-fixing or removal to store, complete all as specified & directed by Engineer-in-Charge. 10 Taking up or down for 20mm bore steel water tubing galvanised with connection, complete all as specified & directed by Engineer-in-Charge. 11 Dismantling water tanks of capacity exceeding 250 Litre but not exceeding 500 litres removing to store, complete all as specified & directed by Engineer-in-Charge. 12 Supply & Fixing for 2nd class HW plain chowkhat and framed, rebated on the solidrounded or chamfered put together with glue pinned at joints, complete all as specified & directed by Engineer-in-Charge. 13 Supply & Fixing for 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. as specified in SSR Part I, Section 8, clause 8.20 (a), complete all as specified & directed by Engineer-in-Charge. 14 Supply & Fixing for 35mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified & directed by Engineer-in-Charge. 15 Supply & Fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified & directed by Engineer-in-Charge. 16 Supply & Fixing Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified & directed by Engineer-in-Charge. 17 Providing 30mm thick factory made 100% solid WPC (Wood polymer composite) Solid Plain / Prelam / Enrouted Plain / Enrouted Painted flush Door Shutter of required size comprising of Virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibres (Wood Powders / rice husk / Wheat husk) and Non-toxic additives made from Extrusion process WPC foam sheet single Extruded (Inner) with density not less than 650 Kg/cum manufacture by an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw withdrawal strength of 2000 N (face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, Modulusof elasticity 850N/mm2 and resistance of spread flame of Class A category with Property of being Termite/Borer Free, Water/Moisture Proof, Fire Retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws for WC/Bathroom/Toilet/Kitchen/Balcony Doors, complete all as specified & directed by Engineer-in-Charge. 18 Providing and Fixing factory made 100% Solid WPC (Wood Polymer Composite) - Door frame of size 75mm x 50mm made from wood Polymer Composite (Single Extruded process) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium carbonate and Natural fibres (Wood Powder/Rice Husk/Wheat Husk) and Non-toxic additives fabricated with meter joints after applying PVC solvent cement & Screwed with full body threaded star headed screws having minimum frame density of 780 Kg /cum manufacture by an ISO 9001-2015 certified Company, having good screw holding capacity(Screw withdrawal strengthof (Min 990N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Draft Fasteners/Hold Fast of required dia and length for WC/Bathroom/Toilet and external uses, complete all as specified & directed by Engineer-in-Charge. 19 Supply & Fixing for factory made uPVC white colour Sliding Window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water ets, making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area n. exc. 2.00 sqm each fixed from ground floor to height of any floors, complete all as specified & directed by Engineer-in-Charge. 20 Supply & Fixing for 7mm thick aluminium grills of surrounded by aluminium C channel and size of opening 75mm x 75mm all as specified and directed fixed from ground floor to height of any floors, complete all as specified & directed by Engineer-in-Charge. 21 Supply & Fixing factory made uPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3 mm (±2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x74mm). Glazed bead (35mm x 20mm) will be mitered cut and fusion welded at all corners. including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick. galvanized steel frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. 5mm thick glazing with selected quality glass (Note: The unit rateexcludes cost of glass and includes all other connected accessories.) area n. exc. 1.00 sqm each fixed from ground floor to height of any floors, complete all as specified & directed by Engineer-in-Charge. 22 Material & labour for preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described applying one coat of pink primer and applying two coat of synthetic enamel paint, complete all as specified & directed by Engineer-in-Charge. 23 Supply & Fixing 300mm long brass ordinary rat tail rod pattern springs including roller, complete all as specified & directed by Engineer-in-Charge. 24 Supply & Fixing 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified & directed by Engineer-in-Charge. 25 Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified & directed by Engineer-in-Charge. 26 Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified & directed by Engineer-in-Charge. 27 Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified & directed by Engineer-in-Charge. 28 Supply & Fixing Hasp and staple for 100mm, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as specified & directed by Engineer-in-Charge. 29 Supply & Fixing 140mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified & directed by Engineer-in-Charge. 30 Supply & Fixing 4mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified & directed by Engineer-in-Charge. 31 Supply & Fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium/pvc sections, complete all as specified & directed by Engineer-in-Charge. 32 Material & labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick with Cement Mortar 1:6, complete all as specified & directed by Engineer-in-Charge. 33 Material & labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over cement mortar 15mm thick with Cement Mortar 1:4, complete all as specified & directed by Engineer-in-Charge. 34 Material & labour for PCC (1:2:4) type B-0 using 12.5mm graded aggregate as in floor of average 25mm thick, complete all as specified & directed by Engineer-in-Charge. 35 Material & labour for 75mm thick cement concrete type C–1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etc., complete all as specified & directed by Engineer-in-Charge. 36 Material & Labour for Non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile not exceeding 0.11 sqm in floors, over and including 15mm thick screed in Cement Mortar (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified & directed by Engineer-in-Charge. 37 Material & Labour for Non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm in floors, over and including 15mm thick screed in Cement Mortar (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified & directed by Engineer-in-Charge. 38 Material & labour for Glazed ceramic tiles in vertical surface 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 15mm cement plaster in 1:4 Cement Mortar, complete all as specified & directed by Engineer-in-Charge. 39 Material & labour for granite (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including, grinding, polishing, moulding the edges and polishing and including over screed bed 20mm thick in Cement Mortar 1:6, complete all as specified & directed by Engineer-in-Charge. 40 Material & labour for 20 to 25mm thick machine cut Kota stone (single piece of required size for steps) flooring over cement screed base laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and Mirror polishing and including 15mm thick screed bed in Cement Mortar 1:4, complete all as specified & directed by Engineer-in-Charge.Note:- Kota stone in S /case should be provided in single piece upto 1.5 m length or as per site requirements complete all as specified and as directed by Engineer-in-Charge. 41 ditto - all as above but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting , dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed, complete all as specified & directed by Engineer-in-Charge.Note:- Kota stone in S /case should be provided in single piece upto 1.5 m length 42 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified & directed by Engineer-in-Charge. 43 Material & labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement mortar 1:4, complete all as specified & directed by Engineer-in-Charge. 44 Material & labour for Porbandar stone masonry, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified & directed by Engineer-in-Charge. 45 Material & labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:3 and even and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge. 46 Material & labour for rendering 15mm thick on stone surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge. 47 Material & labour for 15mm thick rendering in Cement Mortar 1:6 to stone surfaces trowelled to even & smooth w/o using extra cement, complete all as specified & directed by Engineer-in-Charge. 48 Material & Labour for preparing surfaces plastered or un-plastered new surface of walls applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish as per manufacture’s instruction with smooth roller finish complete all as specified and as directed by Engineer-in-Charge. Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. 49 Material & Labour for complete removal of existing treatment by washing down and smoothing old surface of walls including scrapping and applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified & directed by Engineer-in-Charge.Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. 50 Material & Labour for preparing surfaces plastered or un-plastered new surface of ceiling applying two coats of oil bound distemper over a coat of primer two coats as per manufacture instruction with smooth roller finish, complete all as specified & directed by Engineer-in-Charge.Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. 51 Material & Labour for preparing surfaces plastered or un-plastered old surface of ceiling applying two coats of oil bound distemper over a coat of primer two coats as per manufacture instruction with smooth roller finish, complete all as specified & directed by Engineer-in-Charge.Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. 52 Material & labour for complete removal of old plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer’s instructions, complete all as specified & directed by Engineer-in-Charge. 53 Material & labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer’s instructions, complete all as specified & directed by Engineer-in-Charge. 54 Supply & Fixing in repair PVC Floor trap 75mm bore with grating including jointing using solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified & directed by Engineer-in-Charge. 55 Supply & Fixing in repair PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement fixed in cement concrete type B-1 (1:2:4), complete all as specified & directed by Engineer-in-Charge. 56 Taking down eaves gutter or RWP of any description, complete all as specified & directed by Engineer-in-Charge. 57 Supply & Fixing 110mm dia PVC rain water pipe of pressure single socketed with rubber joint, jointed with solvent joint fixed to wall, complete all as specified & directed by Engineer-in-Charge. 58 Supply & Fixing 110mm dia PVC band any radius, complete all as specified & directed by Engineer-in-Charge. 59 Supply & Fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified & directed by Engineer-in-Charge. 60 Supply & Fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified & directed by Engineer-in-Charge. 61 Supply & Fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified & directed by Engineer-in-Charge. 62 Supply & Fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified & directed by Engineer-in-Charge. 63 Supply & Fixing PVC (SWR) bends 110mm bore with/without access door any radius, complete all as specified & directed by Engineer-in-Charge. 64 Supply & Fixing PVC (SWR) bends 75mm bore with/without access door any radius, complete all as specified & directed by Engineer-in-Charge. 65 Supply & Fixing PVC (SWR) single junction T 75mm bore with access door any radius, complete all as specified & directed by Engineer-in-Charge. 66 Supply & Fixing PVC (SWR) single junction T 110mm bore with access door any radius, complete all as specified & directed by Engineer-in-Charge. 67 Supply & Fixing PVC (SWR) vent cowl 110mm dia., complete all as specified & directed by Engineer-in-Charge. 68 Supplying and laying of 16mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified & directed by Engineer-in-Charge. 69 Supplying and laying of 20mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified & directed by Engineer-in-Charge. 70 Supply & Fixing Brass Elbow forspecial fitting of 16mm bore CPVC pipe, complete all as specified & directed by Engineer-in-Charge. 71 Supply & Fixing Brass Tee for special fitting of 16mm bore CPVC pipe, complete all as specified & directed by Engineer-in-Charge. 72 Supply & Fixing Male Brass threaded Adaptor Tee for special fitting of 16mm bore CPVC pipe, complete all as specified & directed by Engineer-in-Charge. 73 Supply & Fixing in repair 15mm bib tap (fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified & directed by Engineer-in-Charge. 74 Supply & Fixing in repairs brass CP shower rose 125mm size fancy type with swivel joint any size including fixing to steel pipe/union for 15mm dia., complete all as specified & directed by Engineer-in-Charge. 75 Supply & Fixing in repair PVC connection of 15mm dia length 600mm, complete all as specified & directed by Engineer-in-Charge. 76 Supply & Fixing in repair Vitreous China wash down water closet pan (pedestal pattern), white with P or S trap with and including plastic water closet seat cover, connection to trap, flushing pipe & anti-syphonage pipe etc., including necessary materials for fittings & making good to floor, complete all as specified & directed by Engineer-in-Charge. 77 Supply & Fixing for in repairs 10 Ltrs. Capacity PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets slim line or equivalent make / model with all accessories, complete all as specified & directed by Engineer-in-Charge. 78 Supply & Fixing for in repair Vitreous China ware wash hand basin white, flat back, size 550mm x 400mm size with cutting for and pinning ends of brackets or erecting stand including 32mm PVC bottle trap, chromium plated 15mm pillar cock, PVC connection 450mm long, CP waste coupling, 32mm dia PVC pipe, complete all as specified & directed by Engineer-in-Charge. 79 Supply & Fixing in repair Bevelled edge mirror, 600mm x 450mm of selected quality glass, mounted on 6mm thick or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed, complete all as specified & directed by Engineer-in-Charge. 80 Supply & Fixing Peg set of three made of teak wood and Aluminium pegs of size 10cm, complete all as specified & directed by Engineer-in-Charge. 81 Supply & Fixing in repair 20mm Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified & directed by Engineer-in-Charge. 82 Supply & Fixing in repair 15mm dia CP Health Faucet with 1mtr long lead fixed in pipe, complete all as specified & directed by Engineer-in-Charge. 83 Supply & Fixing 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position, complete all as specified & directed by Engineer-in-Charge. 84 Supply & Fixing in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete with waste coupling and waste pipes of suitable capacity, complete all as specified & directed by Engineer-in-Charge. 85 Supply & Fixing in repair 15mm bore stop valves/ Angle valve, cast copper alloy fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified & directed by Engineer-in-Charge. 86 Supply & Fixing in repair 15mm dia CP two way angle valve fixed in pipe, complete all as specified & directed by Engineer-in-Charge. 87 Supply & Fixing in repair 20mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed by Engineer-in-Charge. 88 Supply & Fixing in repair Stop valves/Angle valves of size 15mm dia fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed by Engineer-in-Charge. 89 Supply & Fixing in repair Harrison rails (Curtain rod/drapery rod),anodised aluminium alloy, 20mm dia, bracket 2 Nos of each opening and side stopper fancy type of required shape and size, complete all as specified & directed by Engineer-in-Charge. 90 Supply & Fixing in repair Plate racks made out of 1mm thick Stainless steel, of size 750mm x 600mm x 250mm all as specified and directed (make of plate to be used shall be SAIL, IINDAL, SURAJ or equivalent as approved by GE), complete all as specified & directed by Engineer-in-Charge. 91 Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc., including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified & directed by Engineer-in-Charge. 92 Material & labour for 40mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 5mm thick in one layers on concrete surface cement sand mortar 1:3 using water proofing compound @ 3% by weight of cement finished even fair and smooth without using extra cement, complete all as specified & directed by Engineer-in-Charge.Note:- WPC will be measuredand paid separately. 93 Material & labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumens primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely.(ii) Applying APP based pre-fabricated with non-woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method.(iii)Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface. 94 Supply only liquid water proofing compound, complete all as specified & directed by Engineer-in-Charge. 95 Material & labour for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed: -(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely.Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout.(ii) Rendering of uneven surfaces with 6mm thick Cement Mortar 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out. (iii)All junctions’ points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sika guard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE. (iv)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Top seal 107 or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement: Sika Fab-1 or equivalent make in Fosroc / Thremax as approved by GE over base coat as per manufacturers instruction to bottom and vertical sides up to finished floor level+100mm height.The thickness of two layer shall be 1mm.When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. 96 (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick Cement Mortar 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed as per manufacturers specification including rounding of corners and in junctions sloping towards spout. (vii)All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint.(viii) The sunken floor shall be filled with lean concrete 1:7:12. Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained.The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all Material & labour is included in the rates quoted above. 97 Material & labour for weld-mesh of size 75mm x 75mm x 3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and applying Cement Mortar 1:3 all in complete as per the technical specifications and manufacturers instructions, complete all as specified & directed by Engineer-in-Charge. 98 Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth for shafts, cesspits, manholes, pier holes, etc., and getting out in loose/soft soil, complete all as specified & directed by Engineer-in-Charge. 99 Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each, complete all as specified & directed by Engineer-in-Charge. 100 Removing excavated soil not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified & directed by Engineer-in-Charge. 101 Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar, complete all as specified & directed by Engineer-in-Charge. 102 Material & labour for Concrete bed to drain pipes 150mm bore including packing under and hunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, complete all as specified & directed by Engineer-in-Charge. 103 Material & labour for reinforced concrete pipes 150mm bore, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, complete all as specified & directed by Engineer-in-Charge. 104 Material & labour for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified & directed by Engineer-in-Charge. 105 Material & labour for Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in surface channels and drains, complete all as specified & directed by Engineer-in-Charge. 106 Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, bed blocks, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified & directed by Engineer-in-Charge. 107 Supply & Fixing Joist, channel, angle, or tee sections, Fe-410-W (Gde- E-250) quality-B fixed independently, without connecting plates, etc., complete all as specified & directed by Engineer-in-Charge. 108 Material & labour including preparing new surface of steel of any desc over 10 cm width or girth and applying two coat of synthetic enamel paint over red oxide, complete all as specified & directed by Engineer-in-Charge. 109 Material & labour Machine cut kota stone slab 20-25mm thick rubbing and polishing, for Cup-board Shelves, complete all as specified & directed by Engineer-in-Charge. 110 Material & labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in filling in chowkhats, hold fast block etc., complete all as specified & directed by Engineer-in-Charge. 111 Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where-ever required and to expose rusted reinforcement upto depth not exceeding 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor, complete all as specified & directed by Engineer-in-Charge. 112 Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat, complete all as specified & directed by Engineer-in-Charge.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar). 113 Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2mm of Sika Top Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78, complete all as specified & directed by Engineer-in-Charge.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar) 114 Material & labour for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturers specification including preparation of surface thoroughly and cleaning complete where-ever required with using Product: Sikadur ®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTMC 881-78, Type II Grade 2 Class B+C, complete all as specified & directed by Engineer-in-Charge. 115 Material & labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortaras per the technical specifications and manufacturers instructions, complete all as specified & directed by Engineer-in-Charge. 116 Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: SikaRep ® Microcrete-4+ adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep ® Microcrete-4orequivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99, complete all as specified & directed by Engineer-in-Charge. Note: 1 Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work. This is not paid separately.Note: 2 Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement. This is not paid separately. 117 Material & labour Mild CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified & directed by Engineer-in-Charge. 118 -ditto- all as per item No.115 above, but 6mm to 8mm dia. complete all as specified & directed by Engineer-in-Charge. 119 -ditto- all as per item No.115 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified & directed by Engineer-in-Charge. 120 Supply & Fixing in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms), complete all as specified & directed by Engineer-in-Charge. 121 Schedule A E/M 122 Taking down carefully copper /aluminium point wiring (light, fan, socket or power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good distribution surfaces of walls, floors, etc., complete all as specified and directed by Engineer-in-Charge. 123 Taking down unserviceable sub main wiring of any size and including PVC conduit and accessories & removing from site, complete all as specified and directed by Engineer-in-Charge. 124 Taking down electric connections and taking down old unserviceable MCB SPN/SP/TPN/MS, DBs etc., of any capacity, complete all as specified and directed by Engineer-in-Charge. 125 Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- 126 One light point controlled by one, one way switch 127 One fan/Exhaust point controlled by one, one way switch 128 One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size 129 One 3 pin 6 Amps socket outlet on same board 130 One 3 pin 6 Amps socket outlet on independent board. 131 Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multi-strand copper conductor FRLS cable 650/1100Volts grade conforming toIS-694 drawn through PVC conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge. 132 Material & Labour for Point wiring complete with 4 Sqmm single core PVC insulated but unsheathed multi-strand copper conductor FRLS cable 650/1100 Volts grade conforming toIS-694 drawn through PVC conduit (minimum 20mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 4 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, for AC Point including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge. 133 Supply and fixing modular switch 1 way, 6 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. 134 Supply and fixing modular switch 1 way, 16 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. 135 Supply and fixing modular socket, 6 Amps, 2/3 pin combined 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. 136 Supply and fixing modular socket, 6/16 Amps, 2/3 pin combined 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. 137 Supply and fixing modular fan regulator, 120 watt, 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. 138 Supply and fixing ceiling rose, surface Bakelite, 65 x 17 mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. 139 Supply and fixing Buzzer, Ding dong, AC 230Volts single pole, complete all as specified and directed by Engineer-in-Charge. 140 Supply and fixing Modular Bell push 6A 1 module, complete all as specified and directed by Engineer-in-Charge. 141 Supply and fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.Make Philips - Cat Part No- BN100C LED40S-6500 PSU L120 GR or equivalent to Wipro/GE lighting or equivalent make mentioned in Appendix ‘B’ 142 Supply and fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge.Make Philips -Cat Part No BN 021 LED12S 6500 PSU GR or equivalent to Wipro/GE Lighting or equivalent make mentioned in Appendix ‘B’ 143 Supply and fixing in repair of LED 25 Watts (5700K) Bldg Security light fitting, and including with GI Pipe 32 mm dia bracket with connected with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting in position at site, complete all as specified and directed by Engineer-in-Charge.Make: Wipro Cat No LR02-291-XXX-57-XX /Philips / Havells /CG or equivalent make mentioned in Appendix ‘B’ 144 Taking up & down Ceiling Fan, dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material, replacement of 2.5mfd capacitor and re-assembling. including painting of fan and blades, complete all as specified and directed by Engineer-in-Charge. 145 Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed by Engineer-in-Charge.Note: Cutting of wall of appropriate size of fan and making good in cement 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item. 146 Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge.Note : Cutting of wall of appropriate size of fan and making good in cement 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item. 147 Supply and fixing electric water heater, storage type with inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star and above rated complete with all accessories such as safety valve, thermostat, NRV, with Anchor fasteners of suitable size and including Flexible hot/cold connection Pipe -02 Nos, complete all as specified and directed by Engineer-in-Charge. 148 Supply and fixing conventional single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor with pre-payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 along with parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition, complete all as specified and directed by Engineer-in-Charge. 149 Supply and fixing in repair distribution Board cum Meter box wall mounting type of size 980 X 950 X 330mm (minimum) fabricated from polycarbonate sheet, IP 54 cimpartmentalised design, indoor/wallmounting, Cable gland of suitable size prewired and comprising of following :-(a) MCCB cap 100 Amps, 4 Pole, 25 KA - 01 No.(In Coming)(b) MCB SPN 32 Amp, 10 KA - 08 Nos (Out Going)(c) Terminal for distribution (d) 08 Nos of cubical for housing single phase meter(e)06-32Amp SP MCBs-02. All as specified and as directed. Make Hensel or Equivalent 150 Material & Labour for sub mainwiring with two single core 2 x 6 Sqmm PVC (FRLS) insulated multi-strandedflexible copperconductorcable 660/1100 volts grade downin through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 6 Sqmmsinglecore singlestrand copperconductoras continuous earth wire in greencolour connected to commonearth dolly, complete all as specified and directed by Engineer-in-Charge.Note : 1.Two runs ofcable, one run of earth wire, one run of PVC conduit will be measured and paid one unit. 151 Supply & Fixing Sheet metal enclosure (factory made) double door for distribution board (when MCBs are to be used) Single pole neutral 240 V, 12 ways with 200 Amp rated bus bar connection with suitable size of thimbles, complete all as specified and directed by Engineer-in-Charge. 152 Supply and fixing amp rating 240V, 10KA C curve miniature circuit breaker (MCB) SPN 32Ampcurrent carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. 153 Supply and fixing 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. 154 Supply and fixing Modular Motor starter 16A capacity, 02 Module with metal flush box, cover plate of required module for ACs, complete all as specified and directed by Engineer-in-Charge.Make Legrand Cat No 681166 C&S/Anchor or or equivalent make mentioned in Appendix ‘B’ 155 Material & Labour Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 60cmx60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm as Earthing lead with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009, including taking down old unserviceable earthing, complete all as specified and directed by Engineer-in-Charge. 156 Supply and laying of XLPEinsulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor ofsize 50 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc., all connections, including taking down old unserviceable Cable, complete all as specified & directed by Engineer-in-Charge. 157 Supply and laying 50 /38mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor, including taking down old unserviceable DWC pipe, complete all as specified & directed by Engineer-in-Charge.Make : Rex / Poly/ Gemini 158 Material & Labour for cutting existing road/hard standing not exc 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming wateringfinish surface 10 cm from top using PCC 1:3:6; including removal of surpluses soil, complete all as specified & directed by Engineer-in-Charge. 159 Cutting the 50mm bore CI/DI pipes and reducing the required length before laying for inserting of new CI specials such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc., complete all as specified and directed by Engineer-in-Charge. 160 Supplying and laying of CPVC pipes of 40mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches & fitting on walls, ceiling or floors, including taking down old unserviceable CPVC Pipe, complete all as specified and directed by Engineer-in-Charge. 161 Supplying and laying of CPVC pipes of 25mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches & fitting on walls, ceiling or floors, including taking down old unserviceable CPVC Pipe, complete all as specified and directed by Engineer-in-Charge.. 162 Supply & fixing in repair CPVC ball valve of 40mm dia., complete all as specified & directed by Engineer-in-Charge. 163 Supply & fixing in repair CPVC ball valve of 25mm dia., complete all as specified & directed by Engineer-in-Charge.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 43.32 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail