}

Tender For Addn/Altn To Jco/Or Md Accommodation Under Age B/R-I Of Ge (N) Mamun., mamun-Punjab

Military Engineer Services has published Tender For Addn/Altn To Jco/Or Md Accommodation Under Age B/R-I Of Ge (N) Mamun.. Submission Date for this Tender is 30-09-2025. Building Work Tenders in mamun Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

51116592
Tender For Addn/Altn To Jco/Or Md Accommodation Under Age B/R-I Of Ge (N) Mamun.
Tender
Indian
Punjab
Mamun
30-09-2025
BootCamp

Tender Details

Tender For Addn/Altn To Jco/Or Md Accommodation Under Age B/R-I Of Ge (N) Mamun.; 1 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each complete all as specified and directed. 2 Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. 3 Taking down shutters of any description exc 1.5 Sqm but n exc 2 Sqm each complete all as specified and directed. 4 S&F pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats and two coats of synthentic enamel paint complete all as specified and directed. 5 S&F pressed steel frames for doors/windows of size size 105x60 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats and two coats of synthentic enamel paint complete all as specified and directed. 6 S&F Solid PVC door frame of size 50 x 47 mm made out of 5mm wood grain printedPVC sheet used instead of plain colour PVC sheet & edges shall be painted to matchwith printed sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed. 7 S&F pressed steel frames for doors/windows of size size 75x50 mm (1.25mm thick MS sheet)with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats and two coats of synthentic enamel paint complete all as specified and directed. 8 S&F 35mm thick factory made plain framed panelled shutters of2nd class hard wood, one panels with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both face.The size of rail and stile as per IS-1003 (Part-I)(Larger size to be provided) Kiln seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed. 9 S&F 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per section 8 clause 8.20 (a) of SSR Part-I (larger size to be provided)complete all as specified and directed 10 M & L preparation of new wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint over a coat of pink primer complete all as specified & directed. 11 S&F factory made18mm thick WPC (wood plastic composit boards) sheet one side prelam sheet and other side wood nature colour for cupboard shutter of density 600 kg/cm3 bent 90 with 100% termite/water proof, fire rertradent, Eco friendly and finish at all edges at level for making edges lippingusing binding tape etc as in Kitchen cupboard, Cabinet etc complete all as specified /Manufacturers specification and directed 12 All as per Srl item No 11 above but both side without printed. 13 S&F Factory Made Solid PVC Moulded door Shutter With wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded woodgrain collured prelaminated PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. 14 Repair to old steel window not exc 1 sqm including replacement of unserviceable/ damagedhinges, all handles, necessarywelding to shutters and chowkhat for making window in serviceable condition, all members grinding to smooth surface and applying redoxide primer to grinded surface, complete all as specified and directed. 15 S&F Box type Steel windows and ventilators comprised of tubular frameand shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (including 03mm thick plain/ frosted window glass and wire mest etc) with side hung shutters with steel handle and steel peg staydovetailedor welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed. 16 M & L preparation of old wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint complete all as specified & directed. 17 M&L for preparation old steel or iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paintcomplete all as specified and as directed. 18 M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved shade over a coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfacescomplete all as specified and as directed. 19 S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed. 20 Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/clips, rubbish off the premises complete all as specified and directed. 21 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane all as specified and directed. 22 S&F 3 mm thick figured glass , pin head typeand glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane all as specified and directed. 23 S&F 100 mm size butt hinges (as per sample) medium weight, cold rolled mild steel complete all as specified and directed. 24 S&F 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed. 25 S&F aluminiumanodized barrel tower bolts 200 mm of extruded section (as per sample) fixed complete all as specified and directed. 26 S&F 150 mm size aluminium alloy handles, febricated type extruded section(as per sample), complete all as specified and directed. 27 S&F 300mm, ordinary rat tail door springs for door closer, complete all as specified and directed. 28 S&F 100mm hasp and staples,mild steel, wire type stove enamelled black including bolt to hinge plate and fixed with screws complete all as specified and directed. 29 S&F 25mm curtain rails anodised aluminium alloy with brackets, end bulbs, fancy type, fixed in position (as per sample)complete all as specified and directed. 30 Demolition of brick work built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. 31 Brick work(except bricks, using old bricks), sub classB bricksstraight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified & directed. 32 Brick work with fly ash bricks (Old Size bricks)straight or curved on plan exc 6 mtr mean radius built in CM 1:6complete all as specified and directed. 33 Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed. 34 M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed. 35 M&L for Rendering 5mm thick cement plaster on fair faces of brick work, concrete sruface in cement mortar (1:3) as in ceiling finished even and smooth without using extra cement complete all as specified and directed. 36 M&L for rendering 15 mm thick cemet plster on fair faces of brick work or concrte surfacesin CM 1:4 in two layers (5mm finishing layer over 10mm base layer) finished even and surface without using extra cemen with WPC over finishing layercomplete all as specified and directed.Note: WPC shall be measured and paid seperately) 37 M&L for rendering or plastering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas,roof projections, drainge etc including taking out peeled off plaster/ concrete and making the edges in line, in true shape and finishing the surface without using extra cement complete all as specified and directed. 38 M&L for cleaning, breaking, loose concrete, changingofcorressive reinforcement with new reinforcement (if required) and filling plain cement concrete 1:1 1/2 :3 type B0 using 12.5mm graded aggregate using approved bonding chamical(from Fosroc/STP/Sikka/ Dr. Fixit) at places like chajja, sunchades, roof projection, fascia, etc beams, columns etc including necessary scafolding, formwork (upto G+2 floor) etccomplete all as specified and directed. Note :- The cost of scafoldings, formwork, reinforcement etc shall deemed to be included in the quoted rate of item. Reinforcement shall be measured and paid for seperately. 39 M&L for preparation of new plastered surface of external wall and chajjas,making surface smooth using sand paper, priming the surface with alkali resistance primer paintfor external surface, applying one coat of external wall care putty and two coats of exterior emulsion (weather coat) paint complete all as specified & directed. 40 M&L for preparation of new plastered surface of external wall by applying 2mm thick wall care putty and making the surfaace smoothapplying two coats of distemper oil emulsion over a coat of primer of new surface complete all as specified & directed. 41 M&L for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and as directed. 42 M&L for three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and as directed. 43 M&L for preparation of old surface of wall complete removal of existing treatment and applying 2mm thick wall care putty over one coat of primer and making surface even and smooth and applying two coats of oil emulshion distempercomplete all as specified & directed. 44 M&L for complete removal of old existing treatment including preparation of plaster/unplaster surfaces ofwalls, chajja, fascia etc and applying one coat of external wall care putty and two coat of exteior emulsion paint (weather coat) over a coa of primer any shade or colour complete all as specified and directed. 45 M&L two caot of white wash on surface of wall including preparation of old plastered surface complete all as specified & directed 46 M&L two caot of white wash on surface of ceiling including preparation of old plastered surface complete all as specified & directed 47 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqmbut not exceeding 0.18 sqmin floor, skirting/dado or verticle surface etc set and jointed(joint free) in neat cement slurry and pointed in coloured cementover 15mm thick screed bed or bedding layer of mortar in CM 1:4 inculidng dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises, complete all as specified and directed. 48 M&L for glazed ceramic coloured tiles in vertical surface 450x350x7mm or 450x300x7mm thick set and jointedin neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing),rubish off the premises complete all as specified and directed. 49 M&L green Marble work 18-20mm thick (table rubbed and polished) in cooking plateform,window cill, steps, stair case trade & riser etc in 15 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra complete all as specified & directed. 50 M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., Brushing neat cement slurry with 3.0kg of cement per sq. meter complete all as specified and directed 51 M&L for Round chamfering to the edgesof marble/granite slabs not exc 15 mm wide complete all as specified and directed. 52 Taking up or down steel water tubing and connections including cleaning for refixing of pipe 20mm bore dia all as specified and directed. 53 All as per item No 52 here above but 15 mm bore 54 S&F15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. 55 Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed. 56 M&L for cutting chases, pinning in brick work,making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed. 57 S&F20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed. 58 Refixing of old steel tubing 20 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed. 59 S&F 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed. 60 S&F Stop valve concealed cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch lever handle screwed both ends for iron pipe 15mm bore dia fixed in repair, complete all as specified and directed. 61 S&F 15mm bore dia Bib taps, cast copper alloy, chromium plated fancy typeISI marked (as per sample) with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed. 62 S&F in repair towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed. 63 S & F brass CP Shower rose with or without swivel joints,(any size) including fixing to steel pipe or union complete all as specified & directed. 64 S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. 65 S&F in repair Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern(including fixingofflush pipe) including provision of cement concrete bedding, in repair complete all as specified & directed. 66 Demolition of cement concrete unreinforced of any description and in any position not specifically providedand removal of rubbish beyond MOD land complete all as specified and directed. 67 PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete (sunken floors etc) including demolotion of PCC complete all as specified. 68 Rendering 15mm thick on brick work or concrete surfaces in CM 1:4 mixed with water proofing compound to sunken portion with proper slope towards outside, finishing cement concrete or brick work surface even and smooth using extra cement, provide 90 micron polythene film duly applying bitumen coating @ 3.00 Kg/Sqm complete all as specified and directed. Note: WPC shall measured and paid for separately. 69 S & F in repair 10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets including 32mm dia PVC flush pipe of suitable size and making necessary connections to water supply pipe line and jointing to WC,complete all as specified and directed. 70 S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 71 Rotational moulded polyethlene water storage tanks of capacity exc 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existing RCC/PVC tank of any capacity complete all as specified & directed. 72 S&F in repair 20 mm size gun metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixedcast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed. 73 S&F in repair corner glass shelf assembly (as per sample) consisting of 5.5mm thick sheet glass size not less then 300x300x70mm with chromium plated brackets double guard and railing complete all as specified and directed. 74 S&F in repair stainless steel kitchen plate rack of size 750 x 900 mm not less than 1mm thick sheet thickness of approved make fixed with mild steel screw complete all as specified and directed. 75 S&F in repair for Chromium plated peg stay 6 hook as per sample approved by Engr-in-charge, complete all as specified and directed. 76 S&Fkitchen sinks with drainage board made of stainless steel 1mm thick with plugs, washers , PVC waste pipefixed in repair including waste copling; bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. 77 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etccomplete all as specified and directed. 78 S&F in repair 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. 79 S&F in repair 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. 80 S&F in repair 110mm bore dia PVC (SWR) reducers, complete all as specified and directed. 81 S&F in repair 110mm bore dia PVC (SWR) branch piece, single (single Y) equal or unequal with parrallel branches fitted with oval access doors, fixed in repairs complete all as specified and directed. 82 S&F in repair 110mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. 83 S&F in repair 75mm bore dia PVC (SWR) bends, fixed in repair, complete all as specified and directed. 84 S&F in repair PVC (SWR) 75mm bore Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors, fixed in repair complete all as specified and directed. 85 S&F in repair 75mm bore pipe PVC (SWR) vent cowl, fixed in repair, complete all as specified and directed. 86 S&F in PVC floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified and directed. 87 S&F Mild steelTMT bars bars 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed. 88 All asper srl item No 87 above but6 to 8mm dia. 89 M&L 20 mm thick cement plaster in cement mortar 1:4 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid separately) 90 M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid ploymersand reinfoecing acrylic fibers with sun reflective index(SRI) of 100-110 having maximumelongation of 350% tensile strength od 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 grm/sqm and pastinf it properly with overlaping of 50mm and allow it to dry, Apply second coat of undiluted coat @ 0.45 ltr/ Sqm . Apply third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacture of authorised applicator complete all as specified and directed. 91 Note for item No 90 :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface.(b) Conduct ponding test after 7 days, continnue curing of 14 days.(c) All Shifting/ removing of any wire/cable/AC unit/Water tank of any capacity or other any object as per site requirement an re-fixing the same, if needed shall deemed to be included in the quoted rates by the contractor. (d) Removal of any loose/packed items such as mud phuska, terrace tiles, cement screed bed shall be removed and surface shall be made free from depressions before applying treatment to the roof. Quoted rates shall deemed to be includedthis fact into account and no extra payment shall be made on this account. (e) Contractor shall verify availability of the materials in full qty from market before quoting the rates as no extension of time on this ground shall be granted.(f) All the sample/ make for water proofing material mentioned in item shall be got approved from the GE before procuring bulk quantity of material. 92 Supply only liquid water proofing compoundcomplete all as specified and directed. 93 Cutting into existing manholes for connecting new drains for ineternal dia of pipe 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. 94 MS frame work for cooler stand & ladder of Fe 410-w(gde E-250) complete all as specified and directed. 95 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixturesuch as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit and making good disturbed surfaces of walls, floors, etc with cement moratr and finishers to match existing surface complete all as specified and directed. 96 M&L for point wiringusing 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI/MS pressed steel sunken box of pressed steel sunken boxes of adequate size,3mm thick plastic laminated sheet cover fixed with brass screws including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note:- 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible.2) Rate of supplying and fixing modular GI/MS pressed sunken box with support frame deemed to be included in the quoted rates. 97 All as per Ser item No 95 but for one two light point controlled bytwo 2 way switch. 98 All as per Ser item No 95 but for one5/6 Amp socket outlet point on same board controlled by one switch. 99 All as per Ser item No 95 but for one5/6 Amp socket outlet points on independentboard controlled by one switch. 100 All as per Srl item No 95 here-in-before for one 15/16 amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor. 101 S&F switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed. 102 S&F socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type with shutters, 240 volts complete all as specified and as directed. 103 S&F socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed. 104 S&F switch 15/16 Amps, flush type, 240 volts complete all as specified and as directed. 105 S&F switch piano flush button single pole two way 6 Amp 240 volts complete all as specified and as directed. 106 S&FBell push, flush type, 5/6 Amp AC 230 Volt etc complete all as specified and directed. 107 S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed. 108 S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals. 109 S&F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type complete all as specified and directed. 110 S&FLamp holder jumbo modular type, PVC/Polycarbonate type with back plate suitable for batten fitting including 15 W LED Lamp complete all as specified. 111 Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit, removing materials to store for keeping in safe custodyfor taking credit complete all as specified. 112 M & L for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 25mm dia 1.5mm thickwith all accessories incl cutting chases on wall andmaking good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed. 113 Taking out carefully electric meters from meter box after disconnecting electrically and repair/replacement of burnt links, cable peices, drawing cables through PVC flexible conduit of suitable size and refixing the electric meter in same or other indicated location in meter box and sealing meters with high grade tranparent polycarbonate material and galvanized steel wire of suitable length and making electric connections using copper/brass thimbles complete all as specified and directed.Note : (i) Rate of PVC flexible conduit deemed to be included in quoted rates. (ii) PVC wire should be measured and paid seperately under respective item. 114 S&F in replacement of meter boxfor fixing of four single piece moulded without any joint, light weight, weather proof, shockproof material, grey colour with transparent cover, cable entry from bottom and or sides, concealed metal hinges, maintenance free suitable to accommodated one three phase energy energy meter including dismentling of old existing meter & meter box, breaking of seal of meter and fixing new meter box to flush in wall and making good all disturbed surfaces in CM 1:4 to match with existing surface and fixing existing electric energy meter in the box with making all electrical connections with proper thimbles, flexible pipes, refixing seals complete all as specified and directed. 115 Disconneting & taking down ceiling fan / exhaust fan any type/ cap refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors complete all as specified and directed. 116 Disconneting & taking down geyser any type/capacity complete,refixing to the same/other location with all connected accessories afer cleaning replacing anchor bolts complete all as specified and directed. 117 S&F 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. 118 All as per ser item No 116 but for 10 W LED batten fitting 2 feet long. 119 MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar, neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wallincluding cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, painting the plastered surface with same colour complete all as specified and directed. 120 S&Fsurface mounted, bulk head LED luminaire 10 W with and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V, IP 65 protectioncomplete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed. 121 S&Fround/square shaped LED 15Watt recessed/ surface mounted type panel,220 volts AC with Polycarbobnate housing and high efficiency diffuse for glare free light complete with drivers, mounting clips suitable for roof ceiling including connecting up suitabel size flexible copper conductor cable complete all as specified and directed. 122 S&F distribution board iron clad, double door with IP-43 1K-09 protection suitablefor MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 V, 100 Amps, 16 kA of the same make as of distribution board, with MCBs i.e. DP 63A-04 Nos and SP 6 to 32 A-4 Nos of required size making connection with suitable size thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface in CM 1:4 to match the surface as per existing complete all as specified and directed. 123 S&F MCB SP 240V, 50Hz of rating6 to 32 Amp, B curve using suitable size copper thimbles complete all as specified and directed. 124 All as per Ser item No 122 but for size 40 Amps MCB SPN. 125 S&F LED wall security lights of 35 Watt, 230 V having pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W,IP65 protection, IK07 rating,inbuilt electronic driver withPF>0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. 126 Supply, laying and testing ofXLPE insulated, screened, PVC beded galvanized steel srtip or wire armoured, electric cable heavy duty 1100 Volts gradewith standed aluminium conductor of size 35 Sqmm 3.5 core, including taking out old cable complete all as specified and directed. 127 Excavation in trenches in any type of soil not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for laying of cables complete all as specified and directed. 128 Returning filling, in including spreading , levelling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed. 129 Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. 130 M&L for sand filling in trenches as cushion to under ground cables 8 cm thick before laying the cable and 15 cm thick when cables are laid and tested complete all as specified and directed. Note: Only punned thickness i.e 18cm shall be measured and paid. 131 M&L for Sub class ‘B’ bricks (fly ash bricks) old size laid dry, flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed. 132 40mm dia GI tubing, light grade with all fitting laid in trenches or fixed on wall/under road/ floor or pole by means of GI/MS clamps, nut bolts and washers complete all as specified and directed. 133 M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit alongwith angel iron 40x40x3mm frame and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 3 of SSR part I or directedand testing on completion.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 42.96 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail