Tender For Addn / Altn To Cetain Cook House At 2003 Stn Under Ge (Af) Gurgaon.; 1 Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed. 2 Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed. 3 S&F pressed steel frame made out of MS sheet 1.25mm thick of size 105x60mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-0 (12.50 mm graded aggregate) back of chowkhats and incl two coats of synthentic enamel paint complete all as specified and directed. 4 S&F pressed steel frame made out of MS sheet 1.25mm thick of size 125x60mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-0 (12.50 mm graded aggregate) back of chowkhats and incl two coats of synthentic enamel paint complete all as specified and directed. 5 M&L for 30 mm 2nd class hard wood facoty made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain , chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats with wire mesh fitted complete all as specified and directed. 6 M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkatsall as specified and directed 7 M & L preparation of new wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint over a coat of pink primer all as specified and directed 8 S&F of aliminium anodized powder coated window double shutter glazed and guaged of stainless steel wire cloth having nominal dia of wire cloth having nominal dia of wire 0.36 and avg width of aperture1.40 mm along with aluminium section with 50 mm micron anodizing size of frame 125x44.5x6 mm gauge having size of shutter top/bottom/central rail shall be 44.5 x44.5x16 gauhe aluminium section with 50 micron anodizing and 5.5 mm thick black, tinted steel glass to be fixed on glazed portion including aluminium grill and stainless steel hoooks and eye to be provided as stay of shutters etc complete including necessary jointing, cleats, clips, rubber packing, aluminium fittings such as peg stay 150 mm long 1 no each leaf, hinge type B-21 of 100 mm long ( 02 no each leaf) and 100 aluminium tower bolts ( 02 no each leaf) complete all as specified and as directed. Note : cost of black/tinted sheet glass, stainless steel wire cloth, jointing and packing materials, anodized aluminium fitting etc shall be included in quoted rate complete all as specified and directed. 9 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. 10 S & F 3mm thick sheet glass ordinary quality and glazing with oil putty not exe 0.5 sqm in each pane complete all as specified and directed. 11 S & F stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.4 mm and fixed with stainless steel wire staples including necessary wooden bedding complete all as specified and directed. 12 S&F 125 mm long stainless steel Butt hinges, medium weight, cold rolledand fixed complete all as specified and directed. 13 S&F 300 mm long aluminium alloy, sliding door bolt withhasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed. 14 S&F in aluminium tower bolts 200 mm, stove enamelled black, with bright bolt and fixed complete all as specified and directed. 15 S&F 150 mm size aluminium handles, stove enamelled black, ISI markedcomplete all as specified and directed. 16 Supply & fix factory made solid panel PVC door frame of size 50mm x 47mm made out of 5mm thick wood grain printed PVC sheet & edges to printed to match with printed sheet, reinforced with MS Square tube, complete all as specified and directed. 17 S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails.MS frame shall becovered with heat moulded wood grain PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottim rail.Penelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. 18 Demolitin of brickwork built in cement mortar including all quions ,arches,pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles complete all as specified and directed. 19 M&L for Brick work with fly ash bricks (Old Size bricks) straight or curved on plan exc 6 mtr mean radius built in CM (1:6)complete all as specified and directed. 20 M&L for Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls,built in CM (1:4) complete all as specified and directed. 21 Taking down cement plaster on brick walls or stone walls any description etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed. 22 M&L for Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed. 23 M&L for Rendering 05 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3)as in ceiling finished even and fair without using extra cement all as specified and directed. 24 M&L Rendering 15 mm thick cement plaster on fair faces of stone masonry orbrick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cementcomplete all as specified and directed 25 M&L for Rough cast plaster on brick walls consisting under coat of cement and sand mortar 1:3 not less than 10mmm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even complete all as specified and directed. 26 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 27 M&L for preparation of new plastered surface of wall by applying 2mm thick wall care putty and making the surface smooth and applying two coat of oil emulsiondistemper complete all as specified and directed. 28 M&L three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed. 29 Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified & directed. 30 M&L for Cement concrete type C-1, 1:3:6 (using 40mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and smooth complete all as specified 31 M&L for 25 mm thick PCC ,type B-1 1:2:4(20 mm graded aggregate) in flooring cmplete all as specified and directed. 32 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debris from the premises all as specified and directed 33 M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match and the shade of the tilesincluding 15mm screed bed or bedding layer CM 1:6 complete all as specified and directed 34 M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, inskirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tilesincluding 10 mm thick renderingCM 1:4 all as specified and directed. 35 M&L for Baroda green marble stone slab shall be 15 to 19 mm thick laid over 15 mm thick scree bed in cement mortor 1:6 including pointing in white cement 1:2 marble dust shall be provided. The stone shall be meachine cut, uniform in colour , hard sound, dense and homogenious in texture , free from cracks, decay weathering flaws length and width og each peace not less than 1.00mtr all as specified.m thick screed bed or bedding layer of cement mortar 1:6 complete all as specified. 36 M&L glazedcoloured (digital/printed/design) ceramic tiles in vertical surface 450 mm x 300 mm x 7mm thick set and jointed in neat cement slurry and pointed incoloured cement to match the surface over and including 10 mm thick renderingin CM 1:4 complete all as specified and directed 37 Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar all as specified & directed. 38 M&L 20 mm thick Granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills cooking platforms & like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite over 15 mm thick cement screed/renderingin CM 1:4 including Roughening surfaces of old/newconcrete floor/wall by picking,sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with 3.00 kg per sqm complete all as specified & directed. 39 Round chamfering, to the edges of graniten.exc 15mm wide on granite stone shelves complete all as specified & directed. 40 Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm bore dia all as specified and directed. 41 Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 20mm bore dia all as specified and directed. 42 S&F CPVC 20 mm bore outer dia tubes with all fittings short pieces and fixed complete to walls, floor, ceiling etc allas specified. 43 M&L cutting chases pinning in brick mass and making good to facing where required and pointing in cement and making good in CM 1:3 cutting n.exc. 10 cm in girth complete all as specified & directed. 44 S&F 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc complete all as specified & directed. 45 S&F in repair Bib taps for 15 mm bore pipe, cast copper alloy fancy type chromium plated complete all as specified & directed. 46 S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm all as specified and directed 47 S & Fin repairs Vitreous china wash basin , white flat back,size 550 x 400 mm including waste pipe, brackets and cutting for and pinning in ends of brackets or errecting standand 32 mm diaPVC waste pipefixed in repair including waste copling 32mm size full thread, complete all as specified & directed. 48 S&F in replacement 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified & directed. 49 S&F in repair Vitreous china squatting pan (orissa pattern) size 580 X 440 mm, white, complete including fixing to trap, pan including all joints and making good the floor complete all as specified and as directed. 50 S&F in repair PVC flushing cistern 10 ltr capacity incl PVC connection inlet and and outletconnections,brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified & directed. 51 S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 52 Dismantling water tanks of any capacity and removing to store complete all as specified and directed. 53 M&L for Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed. 54 M&L for Rotational moulded polyethlene water storage tanks of capacity1000 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified & directed. 55 S&F in repair 20 mm ball brass valve, high pressure with polythene float and fly nut screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed 56 S&F in repair angle valve valves with iron wheel head, screwed both endsfor iron pipe and fixedcast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed . 57 S&F in repair 100 mm Internal dia PVC pipe in any length with or without ears fixed to walls with clamps or laid in floors with allied fittings complete all as specified and directed 58 S&F in repair 100 mm dia PVC bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed 59 M&L in repair for CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified and directed 60 Dismantling of boarding fix with screws as in kitchen cabnit/ cup board/ partition/ shutteretc and simlar work complete all as specified and as directed 61 S&F wood grain PVCBoard Scratch and strain free (weight not less 9 Kg/Sqm) in Door, Shelves for Cup Boards or Kitchen Cabinets, one side laminated,18/19mm thick as required,jointed by means of PVC Adhesive Solvent and fixed using Self-tapping Aluminium Screws, complete all as specified and as directed. 62 S&F Stainless Steel Silver chrome DoorHandle 100mm long, suitable for fixing of Brass screws inside of the board etc, and Fixed-in-repairs complete all as specified and as directed. 63 S&F Magnetic Door Catcher medium grade to hold approx 1000 mm opening cabinet door and Fixed-in-repairs complete all as specified and directed 64 S&F Continuous (piano) hinges 30 mm,mild steel, bright finish or electro galvanised all as specified and directed 65 M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm padding as roof , surface finished even and smooth in slope if required without using extra cement complete all as specified and directed 66 Taking down carefully existing bitumen tarfelt including plaster and roughning the surface cleaning the surface and removing of the rubbish to a distance exceeding 500m but not exc 1.50 Km and depositing where directed complete all as specified and directed 67 M&L for 15mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified and directed 68 M&L for cleaning the newly plastered surfaces thoroughly with wire brushes and providing water proofing treatment all as specified here in after :- (a) Bituminous primer @ 0.30liter per sqm conforming to IS 3384-1986(b) 3mm thick APP polymeric membrane minimum weighing 3 Kg/Sqm (one layer) laid by torch application method with over laps of 100 mm joints of traverse direction and 75 mm at longitudinal direction duly thermofused by flame torch all as specified in application manuel of the company (c) Applying two coat of aluminium paint @ 100ml/Sqm 69 Supply only liquid water proofing compound 70 Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed 71 M & L for false ceiling work of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the ntermediate channel with connecting clips across the intermediate channel at 600 mm centre to centre complete all as specified and directed 72 M & L for hanging of GI. false ceiling grid with 3 mm dia GI wire(upto necessary required length & 1.2 Mtr c/c) fixed to slopping roof (rafter/purlin/trusses) complete all as specified and directed 73 M & L Non asbestos fibre cement building boards 4 mm thick (one side embosed design), fixed or laid/ inserted to GI grid frame work in ceiling with clips complete all as specified and directed 74 S&F for Anodised powder coated aluminium frame for doors, windows, ventilators and fixed type partition wall with one or more rebates including joining cleat for fixing etc. complete all as specified and directed 75 S&F for 5.5 mmSheet plain/tinted glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane, rubber beading, glazing clips and all necessary fittings complete all as specified and directed 76 S&F for 12 mm PVC board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work complete all as specified and directed 77 M&L for factory made Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge complete all as specified and directed 78 S&F for4 leverMortice lock, vertical type, size 100 mm fixed to aluminium door and shutter complete all as specified and directed 79 S&F for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed 80 S&F for Aluminium body (Die cast) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed 81 Excavation in post holes (or similar holes) in hard /dense soil/any type of hard surface each n exe 0.5 cu.m, gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and as directed. 82 Removal of surplus soil to a distance not exceeding 1.50 km and n exc 5.0 km depositing outside of MOD land or where directed complete all as specified and as directed. 83 M&L for providing cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in foundation filling and mass concrete , post holes, cills, steps; seismic and other similar bands, plinth courses, string courses, ramp, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , on roofs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc including necessary formwork complete all as specified and directed 84 S&F rolled sections, MS Angles, MS tubular Structures, MS Channels, Tee, etc. (Fe 410-W Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins , posts,trusses (framed or unframed) structures where connected to common rafter and running rails and guides for sliding doors, fixed with angles clleats or other connecting plates complete all as specified and as directed. 85 M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specified and as directed. 86 Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any description complete all as specified and as directed. 87 S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding/ridge to wall, fixed with self tapping screws as complete all as specified and as directed. 88 M&L for surface dressing upto a depth of 15cm (on average) as in soft/loose soil complete all as specified and as directed. 89 M&L for 75 mm thick PCC 1:4:8 (40 mm aggregate) as in sub base complete all as specified and as directed. 90 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment complete all as specified and as directed. 91 M&L for 25mm thick sand cushioning including watering and consolidations etc complete all as specified and directed. 92 Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed 93 Dismantling fencing wire mesh, any type etc complete all as specified and directed 94 Dismantling post or struts (wood, steel or RCC) any section incl. taking out embedded in concrete or brickwork portion and making good disturbed ground posts embedded in natural ground complete all as specified and as directed. 95 Fixing only chain link fencingincludingline wires, any mesh, size and any type of standards, rails, straining bolts etc. complete all as specified and as directed. 96 Supply only Chain link MS galvanised fencing , any size or type complete all as specified and as directed. 97 S & F 10 mm dia and over MS bars as in strainers forchain link fencing including necessasary welding and fixing to angle iron complete all as specified and directed. 98 Taking down carefully copper/ Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed. 99 Taking down old u/s ceiling fans/ wall mounted fans of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, oiling and greasing complete including providing flexible twin copper conductor stranded cord from ceiling rose to connect fans complete all as specified and as directed. 100 Taking down old u/s exhaust fans of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, oiling and greasing complete including providing flexible twin copper conductor stranded cord from ceiling rose to connect fans complete all as specified and as directed. 101 Taking down unserviceable MCBDBs/ACs box alongwith MCB/MCCBs SP/SPN/TPN of any make and type including teakwood board to deposit in store for keeping in safe custody for reuse or takeing in schedule of credit of any size/rating and making good disturbed surface of wall/ roofs complete all as specified and as directed. 102 M&L for point wiring for light points controlled by one, one way switch using 1.5 Sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed FRLS cable in and including Heavy duty 2mm thick ISI marked concealed conduit of suitable dia complete with all ISI marked PVC conduit accessories/ fittings and 1.5 sqmm nominal cross sectional area stranded copper conductor PVC insulated unsheathed FRLS green colour cable earth wire and connecting to earth dolly etc. complete all as specified and directed.The point wiring shal include the wiring of light/ outlets of any length from the distribution board via switch to the point. 103 One light/ fan point controlled by one, one way switch. 104 One Socket 3 pin 5 Amps on independent board 105 One Socket 3 pin 5 Amps on the same board, complete all as specified. 106 Complete all as per item No 102 above but using 2.50 Sqmm single core multi stranded copper conductor PVC insulated and unshathed, FRLS grade cable for 15 Amp socket outlet on independent board including 2.50 Sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and directed for the following.Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green 107 S&F piano switch flush type 5 Amps 230 Volts single pole one way complete all as specified and directed. 108 S&F piano switch flush type 15 Amps 230 Volts single pole one way complete all as specified and directed. 109 S&F socket outlet combination 2 in 1, 3 pin 5 Amps flush type universal complete all as specified and directed. 110 S&F socket outlet combination 2 in 1, 3 pin 15 Amps flush type universal complete all as specified and directed. 111 S&F ceiling fan regulator stepped electronic type 120 watt rating, 230 volts, ISI markedcomplete all as specified and directed 112 S&F ceiling rose surface bakelite3 terminal with base plate. 113 S&F in replacement LED tube light fitting 1x16 Watt, 220 V, AC decorative box type with driver, holder incl LED light connecting up with 3 core flexible copper conductor all as specified and directed. 114 M&L for sub main wiring with tworuns of 1.50 Sqmm 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor confirming to IS-694with one run of 1.50 Sqmm single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including concealed conduit and conduit accessoriesincl taking down old u/s submain wiring complete all as specified and directed. Note : Two run of 1.50 sq. mm copper conductor and one run of 1.50 sqmm earthing wire, conduit and conduit accessories will be measured as one lengthh. 115 M&L for sub main wiring with tworuns of 2.50 Sqmm 1100 volts grade single core FRLSPVC insulated unsheathed multistranded copper conductor confirming to IS-694with one run of 2.50 Sqmm single core FRLS PVC insulated unsheathedcopper conductor cable as earth wire drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including concealed conduit and conduit accessoriesincl taking down old u/s submain wiring complete all as specified and directed. Note : Two run of 2.50 sq. mm copper conductor and one run of 2.50 sqmm earthing wire, conduit and conduit accessories will be measured as one lengthh. 116 S&F of double door three phase distribution board 4 way IP54 IK 09 loadline TPN made out of CRCA sheet 1.60 mm thick, phosphatised powder coated with copper bus bar 200 Amp, 415V, earth stud, Din rail, Polymade terminal blocks for inclming and ougoing circuits, inbuilt loose wire box, ground terminal box, poly layer for protection complte all speciifed and directed. Note : (a) Rate of MCCB and MCBs are not included in quoted rates.(b) capacity of Single pole MCB shall be provided as per requirement and direction.(c) Make of MCB, MCCBs and DBs should be same. 117 S&F sheet metal enclosure double door flush concealed suitable for SPN distribution board when MCB to be used having 200 Amp rated bus bar with common neutral link, factory fabricated 12 ways 240 V with IP43 protection including fixing in new location with connection of curcuit and submain as per site requirement complete all as specified and directed.Note : (a) MCBs are to be measured and paid seperately.(b) Makes of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall be deemed be included in quoted rates. 118 S&F sheet metal enclosure double door flush concealed suitable for SPN distribution board when MCB to be used having 200 Amp rated bus bar with common neutral link, factory fabricated 16 ways 240 V with IP43 protection including fixing in new location with connection of curcuit and submain as per site requirement complete all as specified and directed.Note : (a) MCBs are to be measured and paid seperately.(b) Makes of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall be deemed be included in quoted rates. 119 Supply and fixing MCB TPN 415 Volt, 50 Hz, 100 Amp complete all as specified and directed. 120 Supply and fixing miniature circuit breaker (MCB) of SP and current carrying capacity 5-32 Amps, 240V, C curve, in the MCB DB with overload and short circuit protection and rupturing cap not less than 10 kA Complete with connection testing and commissioning complete all as specified and directed. 121 Supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 volts grade earthed system and conforming to IS:7098 of 1995 and of size 3.5 core x 35 Sqmm and laid in trenches/ ducts/ pipe or on pole incl taking out/down old existing cable complete all as specified and directed 122 Excavation in trenches not exc 1.50 m wide and not exc 1.50 m depth, area not exc 10 Sqm on plan for foundation of poles/laying of cables/ stay/ strut and getting out in soft/loose soil complete all as specified and directed. 123 Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. 124 Removing excavated material (soil) n exc 50m and deposting where dirceted at a level not exc 1.50 mtr above the starting point complete all as specified and directed. 125 M&L for dry sand cushioning to under ground cables with 8 cm thick before laying cables and 15cm thick after laying (total 23 cm) and compaction till 18 cm for complete all as specified & directed. Note : Sand Compacted thickness 18cm shall be considered for measurement and payment purpose. 126 M&L for common burnt clay bricks, sub class B grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified & directed. 127 Supply and fixing in repair GI pipe ligt grade 40mm bore in trenches/wall/pole for protection of cables complete all as specified and directed. 128 M & L Earthing complete for sub station equipments with galvanized steel earth pole electrod of size 600x600x6.3mm thick burried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge ofplate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts,check nuts and washers of galvanised or steel all as specified or shown in electrical plate No. 3 of SSR-2009( Part-l), including ncessary earth work and excavation in any strata, GI pipe 20 mm dia light grade for protection of galvanised iron earthing strip upto 7.5 mtrs, and GI pipe 20 mm dia for watering from ground level to earth plate,including concrete chamber of PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) having copping in PCC (1:3:6) Type C-1using 20mm graded stone aggregate. Intemal surface of concrete chamber shall be plasteredwith 12mm thickcement mortar (1;4) and 50mm thick RCC cover in proportion (1:2:4) type B-1using 20mm gradedstone aggregate, reinforced with 8mm dia tor bar@ 80mm c/c both ways and charcoale dust common salt etc.,funneltesting point, 8 mesh per liner inch, including test point , testing, complete incl taking down existing u/s earthing. 129 Supply and fixing exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with blades and frame and louvers including making hole etc complete all as specified and directed. 130 Net Contract Sum will be after deducting Sch of Credit of Rs 85,604.00