}

Tender For Provision Of Proof Yard At Bharatpur Mil Station., bharatpur-Rajasthan

Military Engineer Services has published Tender For Provision Of Proof Yard At Bharatpur Mil Station.. Submission Date for this Tender is 14-10-2025. Building Work Tenders in bharatpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

51112439
Tender For Provision Of Proof Yard At Bharatpur Mil Station.
Tender
Indian
Rajasthan
Bharatpur
14-10-2025
BootCamp

Tender Details

Tender For Provision Of Proof Yard At Bharatpur Mil Station.; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH AND CULVERTas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for LIGHTNING PROTECTIONas listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for INTERNAL E&M SERVICESas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Sch A Part-XI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XIV (SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 12 INTERNAL ELECTRIFICATIONS&FFlame proof ceiling fan of 1200 mm sweep, 5 star ratingcopper wound with super energy efficient including connecting wire PVC insulated twisted flexible0.5 sqmm copper conductor canopy set, down rod, shackle kit, including all standard accessories complete all as specified and as directed byEngineer -in-charge . 13 Supply and fix flame proof exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louversincluding all standard accessories complete all as specified and as directed byEngineer -in-charge . 14 Supply and fixflame proofand weather proof industrial type DBs with various combination of incoming and outgoing MCB suitable for and including (a) 01 No MCB TPN 40 Amps, C type (incoming) (b)04 Nos MCB SP 10 Amps C type (c) 3 Nos MCB SP 20 Amps C type including necessary connection complete all as specified and directed by Engg-in-Charge. 15 ROAD PATH AND CULVERTM&L 200 micron polythene film (white) over sand cushioning all as specified and directed. Note-1Side and end overlaps is included in rate quoted against this Item. 2 Sand cishioning shall be measured and paid separately under respective item of schedule of work 16 SEWAGE DISPOSAL RCC NP3 150mm dia pipes laid on 150mm thick PCC 1:4:8 bed with excavation of 0.70-1.65min any type of soil, including manholes/drop manholes of standard size made of brickmasonary RCC /precast RCC with SFRC ventilating cover and frame .including all items and activities to excute and make sewer line functional. 17 RCC Septic tank designed to carry sewage and sullage water , excavation in any type of soil , PCC 1:4:8 below foundation RCC M-30 design mix in walls base slab, baffle walls and roof slab incl. beams etc with vent shaft, manhole opening with cover connection etc complete with effective depth of 1.5 mtr and overall depth of 3mtr(a )50 Users 18 Soakage wells of 3.00m dia x 4.5M deep exc, in ordinary soil, foundation in PCC (1:3:6) , walls of honey combed and solid RCC slab in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC coverslab in M-25/RR masonary /filling with bricks bats, 19 EXTERNAL WATER SUPPLY Supply, laying in trenches, under floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-7 class specification complete all as specified and directed.the including necessaary rubber gasket joints complete of the size 150 MM dia bore Note :- (i) Excavation and earth work will be measured and paid separately. (ii) Rubber gasket joints shall be deemed to be included in quoted rate. 20 Supply, laying in trenches, under floor, under road, connecting, jointing and testing ductile iron pressure pipe centrifugally cast ISI marked with socket and spigot ends confirming to IS-8329/2000 standard length of K-7 class specification complete all as specified and directed.the including necessaary rubber gasket joints complete of the size 100 MM dia bore Note :- (i) Excavation and earth work will be measured and paid separately.(ii) Rubber gasket joints shall be deemed to be included in quoted rate. 21 Supply and Fixing Air release Valves with two Air outlets conforming to 100 mm dia bore and fixing Up in cast iron water supply mains complete all as specified and directed. 22 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying upto 150 mm dia complete all as specified and directed. 23 M&L of provision of brick masonry valve pit chamber of 3mm thick MS sheet and angle iron frame of 40x40 mm including black bituminous paint and1200x1200x1000 mm size (internal dimensions) including necessary excavation and earth work and frame with cover complete all as specified and directed 24 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure. 25 Supply, install, commissioning and testing factory made (including CPRI type test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz ACsupply system all as specified and directed having busbar chamber with insulated copper bus bars 100 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & 2mm inner and individual compartment for MCCB/MCB & volt/Ampsmeter and 50 x 50 x 5 mm thick angle iron for base frame work.The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. ( KLP Main Panel) 26 Incoming(a) MCCB FP with Termal magnetic release & adjustable type160 A, 36 KA-01 No.Outgoing (a) MCCB FP,63 Amp,16 KA -3 No.(b) Bus bar Aluminium250 Amps- 01 Set of 4(c) Voltmeter size 96x 96mm, 0-600 volts with selector switch -01 No.(d) Ammeter size 96 x 96mm 0-100 Amps, CTs, CTR 0-100 Amps with selector switch - 01 No.(e) Indicator lamp and seletor switch = 1 Set Note: Panel mounted on 2 height pcc platform 27 Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp-04 Nos and MCB SP 6amp-01 No of make sintex/hensel/Fibox 28 S&F of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be basedon Natural light Lux level. Required illuminancelevel for Switching ON is<= 30 lux andfor switching OFF>=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCBs and Auto manual(Sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade SMC Junction box conforming to IP54. For three phase load of 5 KW(Swadeep-02EC5kW3P) with: 3Nos contactors, 3 nos incoming MCBs & 3nos outgoingMCBs of 10-25 Amps each & circuit wiring (copper)of min 10 sqmm.Make:Nature switch:Kakatiya Energy system/Bajaj/Healer, Contactors: BCH/L&t/ SSchneider, MCBs: HAGER /Schneider /L&T (Exora/ AU series ) /C&S. 29 INTERNAL E&M SERVICESSupply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour (or nearest size).(Steel body) 30 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0 .5 KVA

Key Value

Document Fees
INR 3000 /-
EMD
INR 633840.0 /-
Tender Value
INR 6.17 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail