| 1 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DBDouble Door 8 way ( 2 incoming and 6 outgoing) [Through Rate] |
| 2 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 3 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate] |
| 4 | [23.23.10]MISCELLANEOUS 10. Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 5 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 6 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 7 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 8 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] |
| 9 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 10 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 11 | [24.13.14]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 14.10 Sq mm 2core (Arm.) [Through Rate] |
| 12 | Supply, Installation Testing and Commissioning of Smart Air condition Rack for server installed in Police Stations for CCTV system. The Rack should be having overall dimensions of minimum 800 mm wide x 1380 mm height x 1000 mm depth, IP 54 or IP 55 design, ACDB- minimum 6 Socket 5/15 Amp, Cable Manager 1U MS/PVC- Horizontal, Din rail kit etc. and the work should be complete in all respects with supply of Smart Air condition Rack in Police Stations at different locations in Haryana as per list attached including cartage, loading, unloading and fixing all the existing equipment`s such as Server, 24 port switch etc. with making connections of existing cables and configuration with CHMS in original condition complete in all respect with all labour and petty material required to complete the job upto the entire satisfaction of Engineer-In-Charge with following specification:- 1. Should have internal indoor Air Circular system to maintain the internal temperature of rack up to 30? C suitable for working on 24 x7. 2. The Rack should be capable to reduce the Server Noise level should not be more than 30 dB ( in vaccum enviorment). 3. The Rack should be indoor type with air-conditioning system inbuilt consisting of Cooling Capacity: Minimum 1000W, Air Flow of cooling system: 120 CFM, High static backward curved fan ,alarms for critical failure, Controller Unit with Electronic Microprocessor based LED display 4. Fault Protections with alarming:- High Temperature, Low Temperature, Over load/Under load, Over Voltage/under voltage, Humidity indication with control, Alarm indicators: High Temp Fault, Low Temp Fault and Cooling Fault. 5. Dimension of Indoor AC Unit Should be approximate 445mm X 900mm X 260mm (W x D x H) 6.The rack should be equipped with surge protector with minimum following specification: a)The SPD should be MOV based, Nominal Voltage 240V AC. b)Surge handling Capacity: 20KA (Nominal) and 40 KA (Maximum) @ Impulse discharge current (8/20) µs c) Protection Level: 1.9KV, Response time: = 25 ns (L-N) and = 100 ns (N-G) d) Max. backup fuse with branch wiring: 125 A (G), Short-circuit current rating: 25 kA 7. The smart rack should have inbuilt fire and smoke sensor/ Multi criteria detector with hooter. 8. The rack should have provision with auto cut-off power supply to the equipment`s installed inside the rack in case the temperature inside the smart rack increase above 40 Deg Celsius and restore the power supply when temperature dip below 40 Deg Celsius. Should have LCD / LED display for temperature inside the rack. 9. The Rack should have 24U Usable space (Approximate 800mm Width x 1000mm Depth) 10. Rack should be provided with Aero Acoustic sheet of minimum 10mm for sound proofing with thermal insulation. Rack structure should be made of 1.2 mm thick CRCA sheet with sides and Rear Fixed panels, welded structure as per requirement. 11. Cable entry provision at bottom and back panel (cable gland shall be used for termination of cables, unused openings shall be sealed properly). Rack should be finished with pre-treated powder coating 12. Copper refrigerant piping from indoor to outdoor unit, stand, Conduit pipe with power copper cable 3 core x 2.50 sq mm as per actual requirement at site. |
| 13 | Supply, Installation, testing and commissioning of 4G WiFi Router/ Broadband consisting of minimum following specifications as under:-* Max 1 Gbps Downlaod speed.* 200 Mbps upload speedcomplete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 14 | Supply, Installation, testing and commissioning ofHard Disk consisting of SATA 8 TB survelilanceHDD complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 15 | Supply, Installation, testing and commissioning of8 ports POE Plus Switch (Managed) Industrial Switch working range (-20 Degree toplus 70 Degree Celsius) consisting of 8 Gigabit PoE Ports and 2 Gigabit Uplink ports Transmission Distance :-0-100m, Commercial type working at upto -10 to 50 degree celsius temp., power consumptioless than 5 watt complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 16 | Supply, Installation, testing and commissioning of 4G SIM/ Broadband having unlimited data pack with 200/100 mbps broadband plan for 24 Months complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. (for24 Months2119/- = 50856/-) |
| 17 | Supply, Installation, testing and commissioning of 1 KVA online UPS IGBT based with power backup upto 1 hour includingInbuiltSMF battery, Over Voltage Cut-Off Device and Surge Protection etc., complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 18 | Supply, Installation, testing and commissioning of 5 KVA online UPS IGBT based with power backup upto 1 hour ( control room) includingSMF battery, Over Voltage Cut-Off Device, Surge Protection, rack for battery, cable and connector etc complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 19 | Supplying, Installation, Testing and Commissioning of Wall mount 15/17 U outdoor Rack IP 66 With Front Metal Door Lock and Key: Cooling Fan - 1pc,PDU 5AMP, 6 socket - 1 Pc, Cantilever Tray , customised pole mount bracketand making necessary connections etc. complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 20 | SITC ofDevice Side Patch Cords CAT6 ,2/3 mtrlong, 24 AWG Stranded, Unshielded Polycarbonate plug, Gold over Nickel Contactscomplete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 21 | Supply and Erection of 63 mm Outer dia Plain HDPE Pipe PN-6 Category or 6 kg pressure IS: 4984 laid up to 4 Meter with HDD Machine below in ground complete in all respect. |
| 22 | Digging/Drilling for HDPE PIPE and up to 4 meters below in ground level with trench-less horizontal directional drilling and HDPE pipe of size 50 mm to 160 mm pulling machine (HDD) with all labour and material required to complete the job in all respect. |
| 23 | Carry out the surveys for detection of buried utilities (like water pipes, sewer pipes, gas pipelines, electric cables, telecom cables etc.) Utility Mapping using GPR, EPL, GPS and total Station for upto depth of 5 meters. |
| 24 | Supply, Installation, testing and commissioning of Monitoring Screen consisting of 55`` LED Commercial Screen with HDMI and all accessories complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 25 | S/I/T/C of junction box PVC/ Powder coated for I.O`s (information outlets ) complete in all respect including fixing and making necessary connections with labour and material to complete the job in all respect upto the entire satisfaction of Engineer- in -charge of the work . |
| 26 | Supply, Installation, testing and commissioning of Bullet camera consisting of minimum following specifications as under:* Mega Pixels 8 MP* Optical zoom -3.0X*Video Caputure-MP4* Frame Rate- 30 Per Second* Night Vision and night color* Night Vision range-30 meter* Video Capture resolution-1080P* Connectivity Technoloy- Wirelesscomplete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 27 | Supply and erection of Hot Dip Galvanized octagonal pole 7 Metre Long pole with top dia 100 mm and bottom dia 200 mm sheet Thickness - 4 mmwith base plate of size 400 x 400 x 16 mm including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1 :5: 10, conopy to close the top of the pole, Camera and junction box mounting plate in 4 mm complete in all respects upto the entire satisfaction of Engineer-in-charge |
| 28 | Supplying, Installation,, Testing and Commissioning of 4.5 mtr longARM In Octagonal shape having Top Dia - 70 mm, Bottom Dia - 100 mm Sheet thickness -3 mm with Base plate 200 x 200x 10 mm with SS Rope and Turn Buckle,mounting plate of 4 mm forjunction box and Cameras, Hollow Option for Wiring purposes, complete in all respects upto the entire satisfaction of Engineer-in-charge |
| 29 | Supplying,, Installation, Testing and Commissioning of UTP Patch Panel 24 Port loaded for Cat6 Commercial type working at maximum 50 degree celsius temp. complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 30 | Supplying,, Installation, Testing and Commissioning of CAT 6 Patch cord 1 metre long, 24 AWG Stranded, Unshielded Polycarbonate plug, Gold over Nickel Contactscomplete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 31 | Supply, Installation, testing and commissioning of NVR consisting of minimum following specifications as under:-* support 8 Channel IP camera Input* Max 320 Mbpsincoming bandwidth..* Upto 12 MP resolution preview and playback.* Support 2 SATA Ports upto 10 TB each, 2 USB Ports. Commercial type working at maximum 50 degree celsius temp.complete in all respect upto entire satisfaction of Enigneer-In-Charge of the work. |
| 32 | Supply, installation, testing and commissioning of Server for VMS consisting of minimum following specifications as under:- Hardware for Server * CPU -Intel Xeon Silver 4114 @2.2 GHz 10 Core Processor . * Memory -16GB 32GB RAM *2 X 480 GB SSD for OS and Application in RAID 1 Configuration *4 TB usable Capacity Storage for ANPR Event Transactional Video *Windows Server-2019/2022 *Standard Edition 64-Bit Operating System *4x1Gbps NIC Card complete in all respect upto entire satisfaction of Engineer-In-Charge of the work. |
| 33 | Supply, Installation, testing and commissioning of ANPR/BULLET BOX Camera to be integrated with LPU consisting of minimum following specifications as under:- * 1/1.8`` 4 MP Starlight. * Maximum Resolution : 2688 x 1520@25/30 fps. *Built-in 10mm -50mm lens * The maximum illumination distance is 30 mtr. * Automatic number plate recognition. complete in all respect upto entire satisfaction of Engineer-In-Charge of the work. |
| 34 | Supply, Installation, testing and commissioning of Video Management Software per channel/Camera License complete in all respect upto entire satisfaction of Engineer-In-Charge of the work. |
| 35 | Supply, Installation Testing and Commissioning of stand alone local processing unit as CPU-Intel Core i7, Prcoessor (8C/8T) Hard Drive Capacity-500 GB SSDOS: Ubuntu V20.042 XLAN, 4X USB3.1, 2*USB2.0, 4*SERIAL COM PORTS, 2XDP/HDMI/VGA Ports1xAudio Line out plus Mic, Supports Min. 1x2.5` SATA, and 1xM.2 M Key (2280, PCIex4, Supports NVMe)Operating Temperature: -10 to plus 60 DegreesComplete in all respect upto entire satisfaction of Engineer-In-Charge of the work. |
| 36 | Supply, Installation, testing and commissioning of Client Workstation consisting of minimum following specifications as under:- CPU-Intel Core i7, 64 bits 20Core (8P and 12E Cores) Processor * Memory-16GB RAM * Hard Drive Capacity 500 GB SSD Free Space for Client Including ANPR camera message notification *Windows 10/11-Professional *64 Bit Operating System *1x1Gbps NIC Card *1xNvidia RTX 4070 Graphics Card complete in all respect up to entire satisfaction of Engineer-In-Charge of the work |
| 37 | Supply, Installation, testing and commissioning of Video Management Software and Central ANPR Software consisting of Base License complete in all respect up to entire satisfaction of Engineer-In-Charge of the work. |
| 38 | Supply, Installation, testing and commissioning of Software based Automatic Number Plate Recognition Software Application per Channel License, complete in all respect up to entire satisfaction of Engineer-In-Charge of the work |