| 1 | Dismantling and removing partition wall including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead per 1 sqm. |
| 2 | Dismantling and removing door, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead per 1 sqm. |
| 3 | Dismantling and removing ceiling including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead per 1 sqm. |
| 4 | RCC work M-25grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 N. / Square mm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using 12 mm. to 20 mm. size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned (20 mm. size chips not to exceed 25 % ) to be mixed in concrete mixture with approved grade cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days and finishing the exposed surface smooth providing grooves or beads wherever necessary including centering & shuttering cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P, required for the work etc. complete in all respect as per direction of the Engineer in charge. |
| 5 | Providing & fixing TOR Fe-500 reinforcement bars for RCC work of required diameter of approved quality with straightening, cutting, bending, binding welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing fan hooks, hoisting, lowering and laying including cost, conveyance and taxes of M.S. Rods or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction ofE-I-C. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement.) |
| 6 | Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden centering materials with all necessary bracing, ties and supports with level centering covered with bituminous paper including provision of necessary holes and pockets, fan hooks or boxes, switch and board insert plates, clamps and extension bars etc. as per the direction of the Engineer-in-charge and dismantling and removing the shuttering after the required interval from the date of casting, including cost of all materials with transportation, taxes, loading and unloading etc. and all labour, sundries, T&P scaffolding etc. complete. |
| 7 | a)Fifth floor |
| 8 | Fly Ash brick masonary work using (250mm x 120mm x 80mm) size K.B bricks having crushing strength not less than 75 kg/cm2 in cement mortar mix (1:6) on (250mm thick) masonary walls after immersing the bricks for 6 hrs in water before use in superstrure and similar type of work as per drawings. including cost, conveyance, all taxes, royalties, loading and unloading of all materials, including cost of all labour, scaffolding, wateringand curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. |
| 9 | Providing 12mm thick cement plaster to the outside surface of masonary wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats only to proper plumbs and level as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties,labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge |
| 10 | Providing 16mm thick cement plaster to the inside surface of masonary wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plastered surface smooth using wooden floats only to proper plumbs and level as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties,labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge |
| 11 | Providing & Painting two coats with Plastic Emulsion panits of approved shademake or equivalent over a coat of primer and pop by means of roller to inside surface of new walls and ceilling, including preparation of base and finishing the surface smooth including all cost ofmaterials, labour, scafolding, T & P etc. complete as pe the direction ofE-I-C. |
| 12 | Supplying, fitting and fixing in position 7-8mm thick ceramic floor tile of Kajaria/NITCO/JOHNSON ofsizes not less than 12\"X12\"of premiumquality and size inall floors & steps with application of 20 mm thick cement mortarof ( 1: 3)in proper slop and filling the gaps with white cement and colouring the surface with silicon paint finished as per the design & drawing with all cost of materials, labour,conveyance, taxesT&P and complete as per the direction of the Engineer-in-charge |
| 13 | Supplying, fitting and fixing in position 6.5-6.7mm thick ceramic concept walltile with borders of Kajaria/NITCO/ JOHNSON/ EURO of premium quality and size not less than 12\"X12\" in dadoes in all floors at all heights and riser of stepswith application of 12 mm thick cement mortarof ( 1: 3)in proper slop and filling the gaps with white cement and colouring the surface with silicon paint finished as per the design & drawing with all cost of materials, labour,conveyance, taxesT&P and complete as per the direction of the Engineer-in-charge |
| 14 | Supplying, fitting and fixing of Unplasticised Poly Vinyl Chloride (UPVC) (Fenesta/NCL VEKA Ltd) Sliding windows -60 Series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5mm for outer outer frames and window sash of 39mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised upto 50 microns of minimum thgickness of 1.5mm prefabricated and wellded through fusion welding and the window frame shall be fitted with 6mm thick clear toughened glass of saint gobain make duly fiuxed with EPDM weathering seal resistant and the system is to be installed using reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site, etc. including cost and conveyance of all materials, accessories, labour charges and product confirming to ASTMD 638-14,EN-477-95 and other applicable codes and standards. |
| 15 | 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin,moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856,complete as per direction of Engineer-in-charge. |
| 16 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 17 | Polishing work of Mosaic flooring and dado in floor and remove the debris upto 50mt distance from the site complete in all respect as per design and direction of Engineer-in-charge. Fifth Floor |
| 18 | Skirting |
| 19 | Providing average 25mm thick grading Concrete with (1:2:2) using 6mm black hard granite chips using 2% water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance and sundries, T&P etc. complete as per direction of the Engineer -in-charge. |
| 20 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 21 | Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type Modular switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire-Finolex / Polycab / L&T/ Anchor/ Havells) (Make of Modular Box-Great white/ Legrand / Roma/ Havells ) |
| 22 | Single light point controlled by one 6A switch or first light point or group control - Group-C . |
| 23 | Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. (Make of wire-Finolex/ Polycab /L&T/ Anchor/ Havells) |
| 24 | Supply & fixing of 5 / 6 amp socket outlet on existing switch board with6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connectionas per direction of Engineer in Charge. |
| 25 | Supply, fixingwith recessed wiring to 5 / 6 amp socket outlet on separate board250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connectionas per direction of Engineer in Charge. |
| 26 | Supply & fixing of 2 x 6 amp socket outlet controlled by 2 nos6Amp on separate board, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connectionas per direction of Engineer in Charge. |
| 27 | Supply & fixing of 3 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch (Computer) ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge. |
| 28 | Supply & fixing of 6 pin 16 amp socket outletwith 16Amp Switch, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. |
| 29 | Recessed wiring for A.Csocket outlet with 20/25A modular plug socketincluding all accesories and connection as per direction of Engineer in Charge. |
| 30 | Supplying and installation of 32A DP Switch for AC modular type of reputed make as approved suitable for 240V including all accesories and connection as per direction of Engineer in Charge. |
| 31 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Excess running mtr for subsequent point of group control ) |
| 32 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (From BDB to Switch Board & 16A socket points ) |
| 33 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For AC ) |
| 34 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.(Make-Philips/ Bajaj/ Havells/ Crompton) |
| 35 | 24W LED Square Recessed fitting (for Dinning Hall ) with all connections of Philips catalouge RC380B LED25S-6500 G5 L60W60 PSU OD or equivalent |
| 36 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. |
| 37 | Dismantling of existing electrical installation and handover the materials to concerned authority with making good the damages caused complete as required and as per direction of Engineer-in-charge. |
| 38 | Providing all materials, labour, T&P for laying of following dia CPVCpipesS.D.R - 13.5 as per IS-15778 with ISI mark including fixing of required size CPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw etc. including testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Hot water and inside the toilet - Make - Ashirwad, Astral,Supreme 20mm diamete |
| 39 | 25mm diameter |
| 40 | Providing all material, labour,T&P for fitting & fixing offollowingwater supply fittings of Brass Ball Valve with jointing materials etc. including testing the joints with required water pressure. The cost inclusive of all taxes, duties, transportation, scaffolding etc. all complete as per specification & direction of EIC.Make - Zoloto, Jainsons 25mm dia brass ball valve |
| 41 | 20mm dia brass ball valve |
| 42 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes & making good the damages as per specification complete. |
| 43 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. |
| 44 | Providingall materials, labour, T&P for fitting and fixing white glazed vitreous china water closet(European pattern Coupled Closets) with solid seat cover ,control plate & Cistern with Lid of standard quality approved makeincluding supply of sutaible for EWC bolt & clamp including cost of all taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. JAGUAR- CNS-CHR-963SSP - EWC,JCS-WHT-2400- CISTERN,JCP-CHR-292415 - CONTROL PLATE |
| 45 | Providing all materials and labour for fitting and fixing offollowing size white glazedvitreous chinawash hand basinof approved make with supply & fixing of basin bolts & screw,32mm PVC waste pipe of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4)etc. with all taxes, duties, transportation etc. all complete as per direction of EIC. JAGUAR- OPS-WHT-15305- basin,Jaquar - ALD-CHR-769L250X190 -trap,JAGUAR- ALD-CHR-709 - waste coupling |
| 46 | Providing all materials , labour ,T&P and fittings and fixing of different water supply(CP onBrass) fitting as per IS specification & approved make offollowing sizes and specification with leak proof threaded joints with threadseal tape or any other method as required,including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge.Make : Hindware/Jaquar.15mm dia CPBib cock(short body)with wall flangeJAGUAR- CON-CHR-037KN |
| 47 | 15mm dia CPAngle stop cock with wall flange JAGUAR- CON-CHR-053KN |
| 48 | 15mm C.P.Pillar CockJAGUAR-FLR-CHR- 5031NG |
| 49 | CP Soap dishJAGUAR-ACN-CHR-1131N |
| 50 | CP square Towel Ring JAGUAR-ACN-CHR-1121N |
| 51 | Hand shower (Health Faucet),flexble tube&wall Bracket JAGUAR- ADL-CHR-573GA |
| 52 | Shower headJAGUAR-OHS-CHR1989GA |
| 53 | Shower headarm JAGUAR-SHA-CHR-477 |
| 54 | CP 20mm dia x 610mm long towel rod JAGUAR- ACN-CHR- 1111SM |
| 55 | 15mm dia steel braided connection pipe JAGUAR- ALD-805B |
| 56 | Two way 15mm dia CPBib cock(short body)with wall flange JAGUAR- FUS-CHR-29041 |
| 57 | Providing all materials , labour ,T&P and fittings and fixing of Following Size on Extension piece (S.S/CP onBrass) approved make offollowing sizes and specification with leak proof threaded joints with spun yarn and white zinc or any other method as required including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge. |
| 58 | Providing all materials, labour & fitting and fixing 100mm PVC multi floor trapwith cement mortar (1:4) with all taxes, duties etc. all complete as per specification & direction of Engineer-in-charge. Make - Ashirwad, Astral, Supreme |
| 59 | Providing all materials, labour, T&P for fitting and fixing of UPVC SWRpipes (Type-B) confirming to IS-13592/1992 with latest revision & ISI mark both below & above ground level or fixing on wall surface upto 7th floor roof including scaffolding wherever necessary with requisite testing. The cost inclusive of all taxes, transportation, loading & unloading etc. all complete as per specification & direction of the Engineer-in-charge.Make : Ashirwad/ ASTRAL/ORIPLAST/SUPREME/EQUIVALENT. |
| 60 | 110mm diameter |
| 61 | Providing all materials, labour, T&P, fitting and fixing of following dia UPVC SWR fittings of approved make confirming to IS14735/1992 with ISI mark both below & above ground level or fixing on wall surface upto 7th floor roof including scaffolding wherever necessary with requisite testing. The cost inclusive of all taxes, transportation, loading & unloading etc. all complete as per specification & direction of the Engineer-in-charge. Make : Ashirwad/ ASTRAL/ORIPLAST/SUPREME/EQUIVALENT.110mm S Trap |
| 62 | 110mm P Trap |
| 63 | 110mm Cross Tee |
| 64 | 110mm Single Tee with door |
| 65 | 110mm Single Tee Plain |
| 66 | 110mm Plain Bend |
| 67 | 110mm Door Bend |
| 68 | 110mm Vent Cowl |
| 69 | PVC clamp suitable for 110mm dia pipe |
| 70 | 110x75 Reducing Y without door |
| 71 | 75mm Cross Tee |
| 72 | 75mm Plain Bend |
| 73 | Fixing 600x450mm bevelled edge mirror of superior glass mounted on6mm thick A.C sheet or plywood sheet and fixed to woodenplugs with Chromium Plated brass screws and washers complete as per specification and direction of the Engineer in charge |
| 74 | Providing and fixing Suspended Gypsumboard/Armstrong false ceiling (single layer) in different levels , recesses ,flat areas as per design with G.I. framework (of perimeter channels, intermediate channels and ceiling sections) and 12.5 mm tapededge gypsumboard screw fixed to ceiling section as per design , complete with fixing and finishing of tapered and square edges of board with jointing compound paper tape and 2 coats suitable primer including all cost of materials , labour, overheads, T & P etc., complete as per direction of the Engineer-in-Charge.Ceiling to be levelled and free from cracks. Arrangements are to be made to accomodate lightingfixtures, and to be tied with perimeter channels withrequired hard wares etc .complete. |
| 75 | Providing and fixingWall panelling/Partition made out of12 mm ply,1 mm thick laminate( overpartition/ wall panellingfor design ) complete with necessaryHardwood etc. as per the detail design including the cost of all materials, labour, overheads and T & Petc. complete .as per the direction of the Engineer in charge. |
| 76 | 35mmflush doorshutters both side laminated with 4mm thick veener with all labour, iron fittings, and wooden hinged cleats etc fitted and fixed complete in all respect. But excluding the cost of iron fittings as per specification approved by the Department. |
| 77 | Providing, fitting & fixing Floor Spring of Dorma /equivalent make including cost of all materials,labour, Transportation, placing in positionetc. complete.as per the direction of Engineer -in-charge. |
| 78 | Providing, fitting & fixing Door Handle of 450mm long of Dorma/ equivalent make including cost of all materials,labour, Transportation, placing in position etc.complete.as per the direction of Engineer-in-charge. |
| 79 | providing & fixing ofroller blinds in position at all levels with louver made of polyster base febric of approved shade |