Tender For Construction Of Additional Building In Hospital Building At Pallipalayam Municipality., Namakkal-Tamil Nadu

Municipal Adminitration And Water Supply Department has published Tender For Construction Of Additional Building In Hospital Building At Pallipalayam Municipality.. Submission Date for this Tender is 10-10-2025. Building Work Tenders in Namakkal Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

51076268
Tender For Construction Of Additional Building In Hospital Building At Pallipalayam Municipality.
Tender
Indian
Tamil Nadu
Namakkal
10-10-2025

Tender Details

Tender For Construction Of Additional Building In Hospital Building At Pallipalayam Municipality.; 1 Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except inrock requiring blasting inclusive of bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers withan initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms at the site, etc., complete complying with standard specification and as directedby the departmental officers.. 2 Foundation 3 Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 4 Supplying and providing Anti termite pre construction treatment using aldrin or dealdrin or heptochlor as per relavent IS 6313 (part II) code including cost of all materials, labour, hore charges for T&P etc complete. 5 Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 6 Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means 7 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require onlynominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener,side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 8 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) 9 For plane surfaces such as R0.45 floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 10 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 11 For plane surfaces RCC Floor slab, roofslab,loft,landing slabs,etc nacessary supports and strutting upto 3.60m height. 12 Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). 13 BASEMENT 14 Ground Floor 15 First Floor 16 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steelreinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 17 BASEMENT 18 Ground Floor 19 First Floor 20 Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,completecomplying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge 21 upto basement 22 Ground Floor 23 First Floor 24 Brick partition walls of 11.50cm thickness using best quality Burnt Clay Brick of size9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 25 Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laidover cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and threecrushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying withstandard specification and as directed by the departmental officers. (The make and brandof the tiles should be got approved by Executive Engineer before use on works) 26 Finishing the top of roof with one course of machine pressed tiles of following size ofapproved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand)12mm thick mixed with water proofing compound conforming to ISS at 2% by weightof cement used and the joints pointed neatly to full depth of tiles with the same cementmortar mixed with red oxide and water proofing compound including curing etc., completecomplying with standard specification and as directed by the departmental officerr 27 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mmuniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportionof brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters ofapproved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 28 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfacesand curing, etc., in all floors complying with standard specification and as directed by thedepartmental officers 29 Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand),12mmthick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curingetc. complete complying with standard specification and as directed by the departmentalofficers. 30 Distempering the Two Coats of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers. 31 Painting New Plastered Wall Surface with Two finishing coats of ready mixed(Emulsion) of approved quality and colour over one coat priming coat in all floorsincluding the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should begot approved by the Executive Engineer before use on works.) 32 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete. PWD SOR P.No 98. M-0651 33 Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 34 Dadooing walls with following best approved quality, white / colour glazed tiles conformingto IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant TileEpoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use onworks) 35 Supplying and fixing of 2000 litters capacity PVC tank of approved quality including cost of all materials like tank fittings, lead .lift, errection etc complete. PWD SOR PGNO:50 36 Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve (Heavy type ) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of G.I.Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements. (D) 37 25mm Gun Metal Valve 38 32mm Gun Metal Valve 39 Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements PWD SOR PG.NO:147 40 25mm Pipe Coupler 41 32mm Pipe Coupler 42 25mm Pipe Elbow 43 32mm Pipe Elbow 44 25mm Pipe BEND 45 32mm Pipe BEND 46 25mm Pipe Tee 47 32mm Pipe Tee 48 25mm Pipe End Cap 49 32mm Pipe End Cap 50 25 mm x 20 mm Reducer 51 32 mm x 25 mm Reducer 52 25 mm x 20 mm Reducer Tee 53 32 mm x 25 mm Reducer Tee 54 25 mm x 20 mm Reducer Elbow 55 32 mm x 25 mm Reducer Elbow 56 25mm Pipe Jet Nipple 57 32mm Pipe Jet Nipple 58 Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications (D) 59 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting 60 S/F in position of Indian Make White/Colour glazed earthen ware lipped mouth Flat Back Urinal of best approved quality with G.I.Pipe connection to suitable length,32mm bell mouthed P.V.C connection ,15mm dia G.M.Wheel valve,fixing the urinal to the wall in positionwith necessary T.W.plugs ,clamps,screws, shellac etc.,including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I.pipe connection and wheel valve ,painting the pipe with two coats of approved paint over one coat of primer and checked without any leakage complete, complying with standard specifications. - White Colour 61 Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with P trap or S trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. 62 Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessaryinternal conection,earth connection etc.,complete (SD 142) 63 Earthing as per ISI Specification with an earth electrode of 2.1mt class B GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc.,and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 222) 64 Supplying and run off 8 SWG GI wire on walls or below ground level with necessary U nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 74) 65 Supplying and fixing of 4 way Single phase DB of 16amps/way with 16amps DPswitch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers(SD 153) 66 Supplying and fixing of 8 way single phase DB of 16amps/way with 16amps DPswitch with metal glad of 500 volt(side handle) with Fuse and Neutral of suitable T.W. Board of size 40cm x30cmx6.3cm with earth connection etc., complete in all respects as directed by the departemental officers(SD 151) 67 Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet (SD 137) 68 Supplying and fixing of 5 A /15A 3 pinflush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 140) 69 Supply and fixing of 20 Amp DP Plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For A.C Plug) (Legrand (MDS/Hager (L & T make) SD 144 70 Supplying and fixing MCB isolator 32A TP with earth connection (Legrand (MDS/Hager (L & T make) P.No :32 71 Wiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5AFT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (5 points per coil) (SD 18) 72 Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC a0.45essories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch,PVC junction box, 16gauge MS switch box 300mm x 200mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed pvc Fan point. (SD 19) 73 Wiring with 2x1.5sqmmPVC insulated SC unsheated CU conductor of 1100 V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall for 5 AMPS 3 PIN C.S. PLUG POINT AT CONVENIENT PLACES including the cost of cable, PVC pipes and specials, brass screws, flush type 5 amps 3 Pin C.S. plug, 16 gauge Msjoint box, 16 gauge MS switch box covered by laminated hylem sheet 3mm thick, cement, labour and making good of the concealed portion with suitable colour for open plug point. (SD 10) 74 Supply and run off 2 of 1.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 55) 75 Supply and fixing of20W 4 Feet LED Fitting with LED Inluding cost of materials, loading and unloading charges etc., Complete 76 Supply and fixing of 6 Metre Length Single Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm LengthInluding cost of materials, loading and unloading charges etc., Complete. PWD SOR Page no 215, M-2118 77 Supply and fixing of 60W LED Street Light Fitting with LED (Philips/Havells) Inluding cost of materials, loading and unloading charges etc., Complete. PWD SOR Page no 169 M-1297 78 Supply and fixing of 18W LED 3000K Round type resessed fittng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling Inluding cost of materials, loading and unloading charges etc., Complete. PWD SOR page 168, M1286 79 Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1 x 1/8 Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1 thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 129) 80 Supplying and fixing 63 A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD 150) 81 Supply and run off 2 of 4sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (SD 57) 82 Supplying and run off 2 of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 1100 V grade on 7/20 GI bearer wire service connection mains (SD 65) 83 Supply and run of 2 of 4 sqmm (56/0.30) PVC insulated SC unsheathed cu.conductor of 1100 V grade in 25mm dia GI pipe (Class B) suitably bent at both ends with necessary angle iron upright and end supports for main.(SD 70 ) 84 Supplying and fixing of 3 nos. of 100A porcelain fuse units 500 Volt of approved brand having ISI mark in T.W Board of suitable size etc., completed. PWD SOR Page no 220, M1394 85 Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection with 1.5 sqmm PVC unsheadthed Cu. cable and making good of the concealed portion, with suitable colour for concealed power plug point (SD 40) 86 Supply and fixing of 32A fuse units on suitable TW board with necessary internal connections for controlling the power plug Inluding cost of materials, loading and unloading charges etc., Complete. TWD SOR Page 220, M1392 87 Supplying and run off 4of 4 sqwmm (56/0.3) PVC insulated SC unsheatherd cu.conductor of 1100 V grade on 7/20 G.I bearer wire service connection mains (SD 67) 88 Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC 110mm Diabend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab includingfinishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centreof the pipe line in addition to those for more than 3.0 metre pipe length, etc., completecomplying with standard specification and as directed by the departmental officers 89 Supply fixing and errection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification 90 CCTV Camera (Q) 91 Network Video Recorder (32 CHANNEL-2 SATA) Pg:154 Sn:34,d 92 Hard disc for NVR 4TB Pg:155, Sn:38,b 93 24 Port Patch Panel Pg:155, Sn:40,e. 94 Rack With Accesssories -42 U RACK Pn:155, Sn:39,g. 95 Armoured LAN & CCTV Cable (CAT-6) Pn:162, Sn:31,b. 96 Led tv for display (Q) 42 LED TV 97 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter.Solid panel PVC door with frame. PWD SOR P. No 84, M-0391 98 Fabricating Supplying and fixing in position of Aluminium anodized natural colour mattfinish Two Panels with fixed glazing ventilator of 0.30m ht at top with alu.Grill of 10 mm thick openable type window in all floors with aluminium sections ofOuter frame: 37.70x33x2mm @ 0.50 kg/m,Centre mullions:59x33x2.50mm @0.936kg/m,Shutter frame : Z section 24.50x33x3mm @ 0.525kg/m,Aluminium clips:0.109kg/m and with neccessary accssories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass including cost of all materials,labours, power consumption required for fabrication, drilling holes in RCC colun slab, masonry walls sherever necessary with power drills to the required extent and makegood to the original conditons after fixing and also as directed. All the Aluminium sections are to the anodised with matt finish under electrically controlled conditons in accordance with Is 1868/1962 for an average anodic film thickness of 15 microns etc.Complete. 99 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from unplasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system whichprovides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles,locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.M-0673 100 Pre-Painted Galvanized Iron Three Track Sliding Windows: Providing and fixing pre-painted three track, three panel sliding system fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 grams / sqm.) with total coated thickness of 0.58mm.Paint specification: Coated sections should be with primer coat of epoxy primer of 5-7 microns thick, finishpainted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns.Dimensions of sections: Section for outer frame three track should be of 92mm x 44mm, section for shutter should beof 35mm x 49mm for window, section for euro groove should be of 25mm x 24mm and for lap strip should be 30mm x 41mm.Fixing details: The frame and shutter sections should be cut to length, joined with corner brackets made of glass filled nylon. Ethyl Propylene Diamine Monomer (EPDM) Gasket should be used all around glass.Accessories: Corner brackets made of glass filled nylon.Gasket made of Ethyl Propylene Diamine Monomer (EPDM). windows.Single wheel rollers for windows should be provided.Glass: Glass shutter and fixed glass portion should be provided with a glass of 4mm pinhead glass.Window frame should be fixed to brick / concrete masonry by using nylon self-expanding caps and driving MS electro plated 80mm long screws into the caps through frames.M-0667.Page No:104. 101 Supply errection and commisioning of 40 kVA Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications.M-2330 Page no :228-2024-2025. 102 Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.(a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works,wherever necessary to install the System in position and intact.250 Litres.M-0721.Page no :118 . 2024-2025 103 Blue Star 2024 Model 1.5 Ton 5 Star Split Inverter AC - White(ID318YKU, Copper Condenser) 1.5 Ton3 Star BEE Rating 2024 : For energy savings upto 15% (compared to Non-Inverter 1 Star) Auto Restart: No need to manually reset the settings post power-cut Copper : Energy efficient, best in class cooling with easy maintenance.Sleep Mode: Auto-adjusts the temperature to ensure comfort during your sleep.(Q) 104 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. M-0851.Page NO :155 105 Supply and delivery of First Aid Box complete with all First Aid Medicines all Including all charges etc., complete 106 Supply and delivery 4 Nos of Fire Buckets made out of 40x40x6mm MS Angle Including all charges etc., complete 107 Supply and fixing of Water CO2 Stored Pressure Type 4.5Kg capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.M-1982.Page no :251 108 Provision for Goods and Service Tax 18%

Key Value

Document Fees
Refer document
EMD
INR 350000.0 /-
Tender Value
INR 3.50 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail