Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-09-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-10-2025 |
| 2 | 24-09-2025 | Date corrigendum 1 | Date | 27-09-2025 |
| 3 | 11-09-2025 | drawings | Other | 25-09-2025 |
| Sl. No. | Item Description |
| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 2 | SCHEDULEA PART (I)PREPRICEDBUILDING SSR |
| 3 | Lumpsum price worked out by the tenderer for BUILDING & STRUCTURE WORK as listed in Schedule ‘A’ Part-I |
| 4 | Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II |
| 5 | Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III |
| 6 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IV |
| 7 | Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERTS/HARD STANDING as listed in Schedule ‘A’ Part-V |
| 8 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI |
| 9 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VII |
| 10 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII |
| 11 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-IX |
| 12 | Lumpsum price worked out by the tenderer for BOUNDRY WALL AND GATE as listed in Schedule ‘A’ Part-X |
| 13 | Lumpsum price worked out by the tenderer for COOLING APPLIANCE as listed in Schedule ‘A’ Part-XI |
| 14 | SCHEDULE \"A\" SEC-XII (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \"RS 0.00\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 15 | M&L for constructing Septic tanks designed to carrry sewage and sullage water, exc in any type ofsoil,PCC 1:4:8 below foundation, Brick work in CM 1:4 in walls, Base slab, Baffle walls and roof slab (M-25 concrete) including beams etc with vent shaft manhole openings with cover connections etc complete for 25users complete all as specified and shown on drawings No TD/SZ/504 Sheet 1/1. |
| 16 | M&L for constructing Septic tanks designed to carrry sewage and sullage water, exc in any type ofsoil,PCC 1:4:8 below foundation, Brick work in CM 1:4 in walls, Base slab, Baffle walls and roof slab (M-25 concrete) including beams etc with vent shaft manhole openings with cover connections etc complete for 10users complete all as specified and shown on drawings No TD/SZ/504 Sheet 1/1. |
| 17 | M&L for Construction of Brick Masonry SOAK WELL OF SIZE 1.6 M DIA & 3.0 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No. SZ/2020/TD/45 sheet 1/2 to 2/2 |
| 18 | Supply Installation, testing & comissioningintregral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 18 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 18W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along along with sample approval. The LED Luminaire & It\"s driver both should be BIS registered contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Drivercomplete all as specified and as directed. |
| 19 | Supply Installation, testing & comissioningIntegral / batten LED 2ft, 10 watt 220 V, luminaire made of CRCA/extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 2000 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant.The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it\"s driver both should be BIS registered. Contractor shall submit the following reports before supply of sample approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and as directed. |
| 20 | Supply, installation, testing and commissioning of recessed Mounted square luminaire made of CRCA & with single piece molded polycarbonate diffuser. The diffuser shall be so designed that it does not protrude below the luminaire/ceiling & is able to give more volumetric light & higher vertical illumination. The luminaire shall be so designed that it emits light from the inner side walls of the luminaires & shall be hollow from center.The hollow portion of the luminaire should an option to be covered with customizable backplate or un-cut grid ceiling tile. Luminaire shall deliver minimum system lumens of 1500 lumens with a minimum efficacy of 100 lm/W & system wattages ≤ 15W. It should have CCT of 6500°K CRI ≥ 80, SDCMss. The life shall be L70850@ 50K Hrs. The luminaire driver shall have THD≤10% @ full load, PF ≥ 0.90@ full load, internal surge protection of 2KV, operating voltage range of 140V-270V.The luminaire shall have serviceability of Class B. The luminaire shall be IP20 compliant. The fixture design should be with flicker free operation having ripple ≤ 5% the LED driver should comply to IEC61000.3.2,2009 for Harmonics, IEC61347-2-13, 2006 IN Conduction WITH IEC61347-1 ED 2.0, 2007 for Electrical safety, CISPR 15/EN 55015 (9 khZ TO 30MHz) for RFI, EMI/EMC, IEC 62384 for driver performance test. The luminaire driver shall have efficiency of ≥85%. The luminaire driver shall be of the same make /manufacturer/ brand as that of LED luminaires. The luminaire & driver shall have BIS registration & the bidder shall submit the BIS certificate along with technical BID. The LED luminaire manufacturer should have in-house NABL accredited lab to conduct type test, factory acceptance test before dispatch of material,LM79 test & IK test. The bidder shall submit the NABL accreditation of LED luminaire manufacturer alone with technical bid. The bidder shall submit the type test of luminaires & LM79 test reports issued by NABL accredited lab before supply of material. product complying to above specs in signify, LT or Endo complete all as specified and as directed. |
| 21 | S & F Bldg security light fittings high-quality group control enabled integrated LED Building security Light with a minimum system lumen of 3000 lm and system wattage not exceeding 25W with a nominal system efficacy of 110 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10.Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only & shall be from either Lumileds, Osram, Nichia, Cree & APT Electronics make or equivalent. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it\"s driver both should be BIS registered. contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver and including 1.2m long 32mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making electrical connection using 1.5sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting complete all as specified and as directed |
| 22 | S & F Wall mounted type fans of 200 mm sweep, 03 blades aerodynamically balanced with 60 degree oscillation, working Voltage range 230 V, with service value not less than 1.2 BEE 5 star rated with brush less direct current motor(BLDC), the super efficient BLDC motor 50Hz and Noise level not more than 64 dB with 2 years warranty complete all as specified and as directed. |
| 23 | M & L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 4sqmm complete drawn in new PVC concealed conduit 20mm dia and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and as directed.Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with PVC conduit altogether shall be measured as one unit. |
| 24 | M & L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 4 x 4sqmm complete drawn in new PVC concealed conduit 20mm dia and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and as directed.Note: (i) 4 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with20mm dia PVC conduit altogether shall be measured as one unit. |
| 25 | M & L for sub main wiring with PVC insulated unsheathed copper conductor multi stranded FRLSH type 1100V grade 2 x 6sqmm complete drawn in new PVC concealed conduit 25 mm dia and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLSH type cable for continuous earth wire and duly connected to common earth dolly complete all as specified and as directed.Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with 25mm dia PVC conduit altogether shall be measured as one unit. |
| 26 | S & F Modular blanking plate modular type suitable for fixing in modular switch board,complete all as specified and as directed. |
| 27 | S & F power unit suitable for upto 2.0 ton Air Conditioner having push ON-OFF push button switch, motor starter type, single phase, 4 module with and including modular metal flush box with cover plates complete all as specified and as directed. |
| 28 | S & F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specifiedand as directed. |
| 29 | S & F Modular TV socket RJ 46 suitable for housing modular frame plate complete all as specifiedand as directed. |
| 30 | S & F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and as directed. |
| 31 | S & F Surge Protection Device (SPD) 4 module, 25 KA,3Ph+N Right, T1+T2, limp12,5 KA per pole, T2-60KA, complete fixed in Essential DB and making connections by using necessary thimble/washers etc of copper/brass material complete all as specified and as directed. |
| 32 | Supply, installation, testing and commissioning of Smart energy prepaid Meterconfirming to IS-16444: 2015 (Reaffirmed 2020) and as amended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty complete all as specified and as directed. |
| 33 | M&L for making boring hole upto 150 mm dia under road , pavement, hard standing by any means manually / using trenchless technology and inserting HDPE pipe for cable protection complete all as specified and as directed. Note: HDPE Pipe shall be measured and paid separately under respective item of the schedule. |
| 34 | Supply, Installation, testing and commissioning of Package type/ unitised 11KV/433V Outdoor Sub-station, 100 KVA made from GI enclosurecomplete as required confirming to IEC 62271-202 only and relevant IS specifications including K-10 temperature class as applicable for the rating, Internal Arc of 21KA/1 Sec. IAC AB on 1:2:4 PCC foundation of suitable size extending 500mm all around the outdoor enclosure and 1000mm height (above the ground level ) complete with suitable sizes of GI pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40X40X5 mm MS all along with the corner of the foundation of CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply .Package Substation will have the following equipment :- HT Switchgear :-11 KV 630 Amps 21 KA / 3Sec Non Extensible Ring Main Unit Compact Switchgear consisting ofdirect cable module & 1 No motorized Circuit Breakers Modulein SF6 insulated stainless enclosure with sries trips, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through IC x 95 sq. mm Aluminium XLPE cable - 1 No.Vacuum Interrupter & RMU shall be of same make to ensure life cycle optimization.Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along wtih series trip coil (Modbus RS485 complaint.Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.SF6 Gas pressure indicator.Operating sequence of VCB must be O-0.3sec-CO-3 Mins CO - Protection CT shall be minimum 40/1A, 2.5VA, 5P10 - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 95 Sq.mm AI XLPE Cable, incoming cable termination is included within the scope of work - 1 set. |
| 35 | Contd/---TRANSFORMER: -11/0.433KV, 100KVA, 50Hz, OFF load Tap Changer switch, Three Phase, natural ester oil type transformer in corrugated tank (i) Standard IS : IS : 2026 and IS 1180 with latest amendments (2021)(ii) Losses as per 1180 level 2 and Temperature rise shall be as per IS 1180 with latest amendments(iii) Outdoor Installation(iv) Vector group : Dyn 11(v) Rating 100 KVA(vi) Cooling System : KNAN (K for Ester oil)(vii) Winding ; Copper(viii) Magnetic Core : Prime grade of M4 or better(ix) High voltage : 11 KV - 50 Hz(x) Low Voltage : 433 V - 50Hz(xi) System highest Voltage : 12 KV at the HV side(xii) Percentage Impendence Value : As per IS 1180(xiii) Manufacturing testing laboratory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of prime core with second grade / defective core materials(xiv) Insulation Level :HV Power Frequency (KV rms) : 28 KV HV, Impulse withstand voltage (KV peak) : 75 kVp(xv) Tapping : +5% to -15% OLTC @ 2.5%(xvi) HT Termination - Cable Box(xvii) LT termination - cable box and with all accessories i.e. first filling of filtered dehydrated oil and confirming to ID & standard accessories required. |
| 36 | Contd/-----LT PANELLVS PANEL 300 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A./sq.mm; LT panel made up of 1.5/2 mm thick CRCA sheet.INCOMER FROM TRANSFORMERMCCB 4 Pole, 415 Volt, 50 Hz with Microprocessor release 160 Amp with breaking capacity 25KA - 01NoSmart energy Meter (IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head existing End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per existing AMR infrastructure available in the station. The smart meter may be based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (300/5) complete- 01 NoOutgoingMCCB 160A, 50KA, 4 Pole - 2 Nos (for AMF/LT Panel of DG & One spare) & MCB 32 Amps SPN, 10KA, - 2 Nos (For Type-I qtr & spare)25KVAR APFC panel with minimum4 steps as per following tentive steps(10KVAR X1, 5KVAR X3 ) |
| 37 | Contd/-----(i) The APFC Panel shall be sourced directly from the OEM only. The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of Engr-in-Charge. Toensure safety, reliability and accountability of component co ordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall preferably manufacturer PFC components and switchgear. The OEM\"s specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEM\"s only will be accepted & factory acceptance test will be carried outat OEM\"s plant only.(ii) The APFC Panel shall have 10% extra space for future expansion.(iii) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerance, typical GADs, etc for approval of the Garrison Engineer.(iv) The Capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with EMS. The APFC panel should have the capability for environmental monitoring where it is able to provide the real time data for the temperature and humidity inside the panel ambient. The environmental sensors shall be used with a access point, which can be used for multiple sensors, using Green Power wireless communication protocol to transfer the information on real time basis the exact and detailed temperature monitoring. All Civil works such as PCC/RCC foundation, Platform, Filling trench and pedestal etc as per CSS manufacturer\"s recommendation are included in scope of work. |
| 38 | Contd/-----OUTDOOR ENCLOSUREOutdoor type enclosure of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable designed for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment illumination lamp with door operated switch shall be provided for each compartment. |
| 39 | Supplying, erecting & fixing in true vertical position Steel tubular swaged poles (for two pole structure) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metre long), as per IS-2713 including painting with one coat of black bituminous paint throughout internally and externally up to ground level and remaining external surfaces of poles shall be painted with two coats of aluminum paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed.Note: Excavation, earthwork, PCC foundation & coping shall be measured and paid separately under prevalent schedule. |
| 40 | S & FLED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including with necessary brackets / pipes clamps & nuts & bolts for holding the street light fitting and three core copper flexible cable of 1.5 Sqmm as required at site. |
| 41 | S & F UPS for 30 Minutes backup, three phase AC input 300 to 450 Volts, and out put 415 Volts plus or minus 1% complete of capacity 20 KVA complete with and including tubular batteries of suitable capacities as per OEM recommendation and including necessary battery lead connections, lugs, thimbles, nuts, bolts etc complete all as specified and as directed. NOTE:- Quoted rate shall be deemed to inclusive of PCC / MS Work including locking arrangement for protection of UPS & Battery. |
| 42 | Supply, installation, commissioning and testing of High galvanized mast light, shaft in two sections for height 15 metre suitable for, with raising lowering system comprising, head frame, luminaries carriage suitable to install 8 Nos luminaries in symmetrical arrangement along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lighting arrester spike including excavation, earth work and RCC foundation as per recommendation of OEM of high mast and painting complete all as specified and as directed including the following items(a) Foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template(b) Suitable copper cable for JB to individual luminaries connections including MCBs.(c) Outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial digital time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos 9 Amps contactors and raise lower push button, Incoming 25 sqmm 4 core XLPE cable and outgoing 16 & 2.5 sqmm cable terminals. |
| 43 | S & F LED based Flood light, suitable for installation on high mast pole of height 15 M, housing made up of pressure die cast aluminum Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 140 lumen/Watt and a minimum system lumen output of 8400 lumens and maximum system wattage not less than 120 Watts. The LEDs used shall of CCT 5700°K, CR≥70 & SDCM≤5. The Life shall be 50000Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07.The fixture driver should have an operating voltage range of 140-270 V, In-built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10KV SPD bolted inside the luminaire.The luminaire driver & SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire & it\"s driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver. |
| 44 | S & F on wall door plate single sided signage board made out of stainless steel plate with grooving and painting letters complete all as specified and as directed.Note:- The size of board and the size of writing letters as per site requirement. |
| 45 | S & F on ground/wall/hanging on roof single sided sign board made out of 4 mm thick acrylic sheet with reflective vinyl film letters of suitable size including necessary LED light fitting, hanging arrangements/fixing on ground with stainless steel pipe complete all as specified and as directed. Note:- The size of board and the size of writing letters as per site requirement. |
| 46 | S & F powder based MAP 90 fire extinguisher 4 Kg capacity ISI mark IS: 15683 complete all as specified and as directed. |
| 47 | Supply, install, test and commissioning ofLT FEEDER PANEL, TPN 415 Volts, 50 Hz,outdoor cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incomingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable alley aluminium bus bar suitable for carrying of current300 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB\"s (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-Incoming:a) MCCB , AC, 4 Pole, 415 Volt, 50 Hz with Microprocessor release 160 Amp with breaking capacity 16 KA - 01 No.(b)3Ph Multifunction Meter, Model B, class 1, 5A with Relay - 01 Set.(c) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breaker” |
| 48 | Contd..........Outgoing:-(a) MCCB AC 3 Phase 415 V, 50Hz, 4 pole 40 A capacity 16kA with adjustable type thermal and magnetic setting release - 02 Nos. (one Spare)(b) MCCB, AC, 4 Pole, 415 V, 50Hz, 16 KA, capacity 125 Amps with adjustable type thermal and magnetic setting release - 02 No. (one for ECHS Bldg & one for Spare).(c) MCB TPN, 32 Amps - 02 Nos(For pump house & one Spare )(d) MCB SPN, 32 Amps - 04 Nos (one for High mast light, two for Street lights & one Spare).(e) MCB SPN 20 Amps - 01 Nos. (for Sentry post). (f) Digital timer switch Astronomical, double pole complete. |
| 49 | M & L for Loop in Loop out box of FRP made with IP65 Protection of thermoplastic breaker box with metric knock out for cable entry & exist , combi climate cable glands IP 66/67 for cable entry and grommets IP 65 for conduit for cable exist with MCB 6 Amp SP 10KA C curve terminal as PVC connector heavy duty 32 Amp 4 Way for cable with necessary fixing arrangement and cable gland etc complete all as specified and as directed. |
| 50 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 80 KW (100 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Imphal(Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering80 KW (100 KVA) atoutdoor atmospheric conditions at Imphal, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lubrication oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lubrication oil, oil pressure, over speed etc) fuel tank and first fill of lubrication oil and other consumables etc .(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 80 KW (100 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications. |
| 51 | Contd /-(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition.(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: - Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum busbar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload |
| 52 | Contd /-(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer\"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level |
| 53 | S & F Refrigerator electric driven capacity195 litres BEE 5 star rated complete all as specified and as directed. |
| 54 | S & F electronic type Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and current carrying capacity 1.0 KVA complete all as specified and as directed. |
| 55 | S & F electronic type Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and current carrying capacity 2.0 KVA complete all as specified and as directed. |
| 56 | S & F electronic type Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and current carrying capacity 4.0 KVA complete all as specified and as directed. |
| 57 | M & Lfor earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. complete all as specified and as directed. |
| 58 | M & L for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32mmx6mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and as directed .Note : - Length of earthwire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately. |
| 59 | M & L for earthing with Copper earth plate electrode of size 60cm x 60 cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of Copper/brass using Copper strip 20x3mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 25mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and directed by Engr-in-Charge.Note : - Length of earth wire and protection pipe in above mentioned item is considered upto 7.50 m length, additional length required shall be measured and paid separately. |
| 60 | S & F 80mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and as directed. |
| 61 | Supply, installation testing and commissioning open well horizontal type submersible pumpset, electric driven motor 3 Phase, insulation class B, voltage range AC 350 to 440 Volt, flatter efficiency curve, 50Hz, CED coating, head 30 mtr, discharge 450 LPM, suction and delivery dia as per standard design of OEM suitable for delivery 450 LPM discharge at delivery pipeinclusive of suitable length (from submersible motor to starter) submersible cable PVC insulated and sheathed flat submersible cable with stranded copper conductor of size 3 core 6 Sqmm 1100 Volts grade including lugs and fixed in submersible pump & starter etc complete all as specified and as directed. (1 W + 1 SB). |
| 62 | Supply, installation, commissioning and testing of LT feeder pillar box of size 900x1200x300 mm,outdoorcubical type, floor mounted, vermin proof factory made of CRCA Sheet 3.15 mm thickand MS angle of size 40x40x5mm having suitable legs, double door both side openable with locking and key arrangement with two Nos pad lock50 mm make Godrej/Harison,powder coated with three phase, 415 volts, 50 Hz, AC supply all as directed by Engr-in-Charge and comprising of the following:-(a) INCOMING(i) MPCB, 3 Pole, 415 Volts, 32 Amps, breaking capacity 25 KA having thermal setting 100% and magnetic setting upto 70% - 01 No(b) OUTGOING(i) Fully automatic submersible star delta pump starter with auto unit, 3 phase 415 volts, relay range (10-16) with short circuit protection including contactors complete for5 Hp Submersible Motor - 02 No (ii) Single phase preventer - 01 No(iii) Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) INDICATING DEVICES(i)LED indicating lamp with holder for main supply indicating RYB (set of three) - 01 Set(ii) Indication lamp for starter power ON/OFF - 01 Nos |
| 63 | M & L for construction of valve chamber of size 950mm X 950mm X 950mm (Internal dimensions) including necessary earth work in any type of soil, PCC 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in base concrete, brick work (one and half brick thick) in CM 1:6 with 20 mm thick cement plaster internally and externally (15cm depth below GL) in two layers of (12 mm and 8 mm) in cement mortar 1:4, 3 mm thickmild steel sheet cover and 50 mmx 50 mm x 6mm thick mild steel angle iron frame including locking arrangement, handle etc, frame welded to base plate of size 150 mm X 12 mm thick (All structural steel are grade E-165 and conforming to IS 15911: 2010), base plate fixed with all fixing arrangement in 200 mm thick PCC coping 1:2:4 type B1 (using 20mm graded crushed aggregate) including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash as per drawing No. TD/EM/6 sheet Nos 1/2 & 2/2 of HQ CE Shillong Zone complete all as specified and as directed. |
| 64 | S & F chromium plated health faucet with 15 mm bore 1.2 mitre long tube acrylic type complete all as specified and as directed. |
| 65 | S & F 20 mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for CPVC or for union complete all as specified and as directed. |
| 66 | S & Fchromium plated health faucet with 15 mm bore with 1.2metre long flexible and wall hook including making connectioncomplete all as specified and as directed. |
| 67 | M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and as directed. |
| 68 | S & Fconcertina coil 600mm dia made from galvanised iron, wire dia 2.5mm central core wire made from high tensile carbon wire conforming to IS 4454/Part-I/Grade-SM duly hot dipped galvanised, UTS 1670 N/mm Sqr, zinc coating with minimum 230GSM weight per coil 8.5Kg complete all as specified and as directed. |
| 69 | M & L for Broken glass coping on top of walls in CM 1:3 on top of wall as per shown in drawing complete all as specified and as directed. |
| 70 | Boring for Bored cast in situ piles of dia 450mm and 6 metres in soil and getting out and disposal of spoil to a distance 1.5 Km using DMC method (Direct mud circulation) complete all as specified and as directed. |
| 71 | M & L for reinforcement cement concrete M-30 (Design Mix), (Using 20 mm graded crushed stone aggregate ) as in cast-in-situ bored pile foundationcomplete all as specified and as directed. |
| 72 | Supply only 4mm dia mild steel galvanisedchain link fencing 75mm x 75mm wire mesh made up into mattresses or cages, lapped, wired and laid in position complete all as specified and as directed. |
| 73 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolt etc including provision of binding wire complete all as specified and as directed. |
| 74 | S & F Sink cock for SS Sink of 15mm dia cast copper alloy chromium plated, wall mounted type (Swan neck) with crutch or butterfly handle fixing in CPVC pipe complete all as specified and as directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail