| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | a)1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | b) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 7 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 9 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily |
| 10 | Glazed Vitrified tiles Matt/Antiskid finish of size(Size of Tile 600 x 600 mm ) |
| 11 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 12 | a) Hot finished welded type tubes. |
| 13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 14 | Providing and fixing PVC flooring sheets in flooring and skirting in approved pattern on a smooth and damp proof base using rubber based adhessives of approved quality and manufacture like Dunlop S - 758 , Fevicol SR 998 or equivalent , copper strip and other materials required at site including rolling with light wooden roller weighing about 5 Kg all complete as directed by the Engineer - in - charge in approved colour and shade (1 mm thick). (The rate includes the cost of materials , labour other materials required and transportation to various locations etc. complete.) |
| 15 | Providing 2mm thick Polycarbonate solid compact sheet roofing including vertical / curved surfaces, fixed to the frame using polycarbonate joining accessories, rafter gasket, capping bars etc. where ever necessary and applying silicon water tight sealant of approved quality and make, wherever necessary so as to make the roofing water tight and providing necessary aluminium channel at the edge excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required, as per the instruction of the Engineer in charge. |
| 16 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 17 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-charge. |
| 18 | Laying available false ceiling tiles [Appx Area:40sqm] in position in the existing false ceiling grid including necessary cutting etc complete as per the direction of Engineer in charge. |
| 19 | 12 mm cement plaster of mix : |
| 20 | 1:6 (1 cement: 6 fine sand) |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 22 | Two or more coats on new work. |
| 23 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 24 | a)Two coats. |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 26 | One or more coats on old work. |
| 27 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. |
| 28 | In cement mortar |
| 29 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 30 | Carefully Dismantling the existing transaction counter of dimension 9950X600X750mm alongwith 4 Nos side tableof size 750X600X750mm with granite top and SS tube,8mm glass protective measures etc from its current position in the ground floor ofCSC building Guruvayur and relocating in the ground floor of TE building as per the approved layout plan and as per the instructions of Engineer in charge. |
| 31 | Carefully Removing existing damaged pvc flooring [Appx area:40.00Sqm], including all associated adhesive residues, and thoroughly clean the sub floor in preparation for new finish installation as per the direction of Engineer in Charge. |
| 32 | Dismantling the existing collapsible gate[appx area 5 Sqm] in front of CSC at CSC building and refixing in front of the proposedCSC at TE building including all cutting of walls, floors etc and making good etc complete as per the direction of Engineer in Charge |
| 33 | Carefully dismantling existing 12 mm thick frameless toughened glass door shutter [Appx Area:4.00m2] ncluding all fittings, fixed frames at CSC buildingincluding refixing at new CSC at TE building etc all complete as per direction of Engineer-in-charge[Rate includes the cost of floor spring etc complete} |
| 34 | Fixing available aluminium work forpartitions doors with available tubular sections/appropriate Z sections and other sectionsfixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,providing newAluminium snap beading wherever necessary for fixing available glazing / available paneling, new C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 35 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |