| 1 | Civil work |
| 2 | Excavation work by mechanical means (Hydraulic excavator) manual means in foundation trenches or drain including dressing of side and ramming of bottoms, lift up to 1.5 meter, including getting out the excavated soil as directed, with a lead of 50 meter. |
| 3 | Provide and laying in position cement concrete of specified grad excluding the cost of centring and shuttering - All work up to plinth level:1:1.5:3 (1 cement: 2 coarse sand(zone-III): 4 graded stone aggregate 20 mm nominal size) |
| 4 | Provide and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level:1:2:4 (1 cement: 2 coarse sand(zone-III): 4 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified of reinforced cement concrete, excluding the cost of centring, shuttering, finishing and reinforcement all work up to plinth level:1:1.5:3(1cement 1.5coarse sand (zone-III):3graded stone aggregate 20mm nominal size) |
| 6 | Providing and laying in position specified of reinforced cement concrete, excluding the cost of centring, shuttering, finishing and reinforcement all work up to plinth level:1:2:4(1cement 2coarse sand 4graded stone aggregate 20mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 150 landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level. excluding the cost of centring, shuttering finishing and reinforcement with 1:1.5:3(1cement 1.5 coarse sand 3 graded stone aggregate 20mm nominal size. |
| 8 | First Brick work with common burnt clay F.P.S. (nonmodular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 9 | Random rubble masonry with hard stone in foundation and plinth incl. levelling up with cement concrete 1:6:12 (1 cement:6 coarse sand:12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6(1cement:6coarse sand) |
| 10 | marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) backing filled with a Grout of average 12mm thick in cement mortar 1:3(1cement 3 coarse sand including pointing with white cement mortar 1:2 ( 1white cement 2 marble dust) with an admixture of pigment to match the marble shade(to be secured to the banking by means of cramps which shall be paid for separately) Area of slab over 0.50 sqm. |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202(part I) non-decorative type core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (35mm thick) |
| 12 | Structural steel work riveted bolted or welded in built up sections trusses and framed work including cutting hosting fixing in position and applying a priming coat of approved steel primer all complete. |
| 13 | Providing and fixing in position collapsible gate (Shutter) with vertical channel 20x10x2mm braced with flat iron diagonal 20x5 mm size with top and bottom rails of T- iron 40x40x6mm with 38mm patter with bolt and nuts loading arrangements etc. complete. |
| 14 | Providing and fixing angle T-iron frames for doors, windows, and ventilators of mild steel angle sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 15 | Providing and fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. flat 15x3 mm and nuts & bolts complete. Galvanised M.S. wire gauze with 0.63mm diameter wire and 1.4mm aperture on both sides. |
| 16 | Providing and laying vitrified floor tiles in different size (thickness to be specified by the manufacture) with water absorption\"s less than 0.08% and conforming to IS:15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 incl. grouting the joints with white cement and matching pigments etc.complete size of tile 600x600mm |
| 17 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete up to any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape whereverrequired 0.80mm thick with zinc |
| 18 | 15mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement: 4 fine sand) |
| 19 | 12mm cement plaster finished with a floating coat of neat cement of mix: 1:3 (1 cement: 3fine sand) |
| 20 | Plaster with cement mortar in 1:4 cement and local sand 12-20mm thick i/c supply of all required material labour T&P etc. for the completion of work. |
| 21 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacture of required shade and colour all complete to achieve even shade and colour.as per manufacture\"s specification. |
| 22 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: New work (Two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 23 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 24 | Painting with aluminium paint of approved brand and manufacture to give an even shade:Two or more coats on new work. |
| 25 | Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the wall complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. With cement mortar 1:4(1 cement: 4 finesand) |
| 26 | Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10cm with cement concrete 1:3:6 (1cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete. including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-charge. |
| 27 | Supply and fixing of 4mm thick plain glass with silicon paste and pins including labour, T&P etc. for the completion of work. |
| 28 | Renewal of old putty and replace with silicon paste of glass panes (length) |
| 29 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 30 | Colour washing such as green, blue or buff to give an even shade: New work (two or more coats) with a base coat of white washing with lime. |
| 31 | Painting wood work with Deluxe multi surface paint of required shade. Two or more coat applied @ 0.09 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:one or more coats on old work. |
| 33 | Painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. |
| 34 | Finishing walls with acrylic smooth exterior paint of required shade: old work (Two or more coat applied @ 1.67ltr. /10sqm) on existing cement paint surface. |
| 35 | Old work (One or more coat applied @ 0.90ltr. /10sqm). |
| 36 | Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-charge. |
| 37 | Orissa pattern W.C. Pan of size 580x400mm. |
| 38 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per direction of Engineer-in-charge. |
| 39 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge. 1:3:6 or richer mix. |
| 40 | Demolishing R.C.C work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50meter lead as per direction of Engineer-in-charge. |
| 41 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50meter lead as per direction Engineer-in-charge. (In cement mortar) |
| 42 | Demolishing of brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metre lead as per direction of Engineer-in-charge. |
| 43 | Dismantling bituminous road manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50meter lead as per direction of Engineer-in-charge: |
| 44 | Dismantling of flushing cistern of all types (C.I/PVC/Vitreous china) i/c stacking of useful materials near the site and disposal of unserviceable materials within 50meter lead. |
| 45 | White vitreous china flat back wash basin size 630x450mm with a pair of 15mm C.P. brass pillar taps. |
| 46 | White vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15mm C.P. brass pillar taps with elbow including operated levers. |
| 47 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass china with rubber plug,40mm C.P. brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required: Size 600x450x200mm |
| 48 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. pan 580x440 mm |
| 49 | Providing and fixing white vitreous china pedestal type (European Type/wash down type) water closet pan |
| 50 | Providing and fixing soil, waste and vent pipes: 75mm, PVC |
| 51 | Providing and fixing soil, waste and vent pipes: 100mm, PVC |
| 52 | Providing and fixing soil, waste and vent pipes: 150mm, PVC |
| 53 | Providing and fixing for CI special as C.I. plain band 75mm diameter in C.I. pipe line work i/c labour T&P etc complete |
| 54 | Making of sock pit 2.5m diameter 3.0 meter. Deep with 45x45cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mm dia,1.8 m long complete as per standard design. With common burnt clay F.P.S. brick of class designation 7.5 |
| 55 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement 4 coarse sand) Ordinary cement without any pigment. |
| 56 | Provide and fixing concertina coil fencing with punched tape concertina coil 600 mm diameter 10 meter openablelength, having 50 nos rounds per 6 meter length, up to 3 m height of wall with existing angle iron Y shaped placed 2.4 m or 3 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete ass per direction of Engineer-in charge,(cost of M.S. angle, C.C. blocks shall be paid separately) |
| 57 | 25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse sand) |
| 58 | Providing and fixing aluminium work for doors and partitions with extruded built up standard tubular sections/appropriate Z section and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required diameter and size i/c necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required i/c cleat angle aluminium snap beading for glazing / panelling C.P. brass / stainless steel screws, all complete as per the directions of Engineer-in charge.(Glazing, panelling and dash fasteners to be paid for separately) |
| 59 | providing and fixingfalse ceiling at all heights with GRG Glass fibre reinforced gypsum false ceiling tiles of size of 595x595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225 :1987,Noncombustible as per BS 476( part 4) 1970 and light reflectance of 85% ( minimum) to be laid in true horizontal level suspended on inter- locking metal T-grid of hot dipped galvanised iron section of 0.33mm thick (Galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm,cross-T of size 15x32 mm of length 1200mm and secondary intermediate 600mm suspended fromcelling using galvanised mild steel items (galvanizing @ 80 grams per sqm i.e.50mm long 8mm outer diameter m-6 dash fasteners 6mm diameter fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size 85x25x2 mm galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawlplugs at 450 mm centre to centre and 40mm long dry wall wood screws. the work shall be carried out as per specifications, drawing and as per directions of the Engineer - in- charge.(with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles.) |
| 60 | Specialized technicians |
| 61 | Block board construction flush door with teak wood ply on both faces 35mm thick |
| 62 | Decorative plywood 4 mm |
| 63 | Calcium silicate base compound for jointing calcium silicate tiles |
| 64 | Dehradun white lime |
| 65 | Silicon and acrylic emulsion |
| 66 | White Cement based putty |
| 67 | Acrylic Exterior primer |
| 68 | Water proofing cement paint |
| 69 | Plaster of Paris |
| 70 | Coarse sand (zone 3) |
| 71 | Fine sand (zone 4) |
| 72 | Mild steel round bar 12mm diameter and below |
| 73 | Mild steel round bar above 12mm diameter |
| 74 | Window Glass / Transparent fiber sheet (3mm,4mm thickness) |
| 75 | Stone for masonry work |
| 76 | Water proofing materials |
| 77 | Welding by gas plant |
| 78 | Welding by electric plant |
| 79 | Stone Aggregate (Sigle size): 100 mm nominal size |
| 80 | Stone Aggregate (Sigle size): 80 mm nominal size |
| 81 | Pressed steel door frames (mild steel sheet 1.60 mm) Profile \"\"E\"\" |
| 82 | Provide and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with10.30.1 4 mm thick glass panes 10.30.25.5 mm thick glass panes |
| 83 | Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (SLIT) 150 mm square with a height of 8mm and weighing not less than 100 grams. |
| 84 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead. |
| 85 | Providing and fixing 1st quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make , in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 86 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make , in all colours, shades, except White, ivory Grey, Fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 87 | Providing and fixing P.V.C. waste pipe for sink or wash basin i/c P.V.C. waste fittings complete. (Flexible pipe - 32mm dia) |
| 88 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 (15mm nominal bore) |
| 89 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (15mm nominal bore) |
| 90 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 grams.(15mm nominal bore) |
| 91 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (15mm nominal bore) |
| 92 | Providing and fixing G.I. Union in G.I. pipe i/c cutting and threading the pipe and making long screws etc. compete (New work): every 5meter |
| 93 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 94 | Earth work in excavation by mechanical means (Hydraulic excavated)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10sqm on plan), i/c dressing of sides and ramming of bottom, for all lift, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 95 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-3) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-3) : 8 graded stone aggregate 20 mm nominal size), inside plastering 12 mm thick withcement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with floating coat of neat cement complete as per standard design. |
| 96 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern |
| 97 | Gridding and polis old mosaic floor |
| 98 | Supply and fixing of exhaust fan i/c providing and fixing 12\"\" in toilet and bath |
| 99 | Provide and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level:1:4:8 (1 cement: 4 coarse sand(zone-III): 8 graded stone aggregate 40 mm nominal size) |
| 100 | Brick work with common burnt clay F.P.S. (nonmodular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 101 | Steel work welded in built up sections/framed work, i/c cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required: In grating, frames, guard bar, ladder, railing, brackets, gates and similar works |
| 102 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, i/c applying primer coat of approved steel primer.M.S. tube |
| 103 | Providing and fixing on PVC drain pipes conforming to IS: 13592 Type A, i/c jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion, Single socketed pipes. |
| 104 | Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4(1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1cement 1.5 coarse sand 3 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10(1cement 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (nonmodular) bricks of class designation 7.5 |
| 105 | Providing and fixing soil, waste and vent pipes: R.C.C. (200mm,300mm thickness) |
| 106 | The term \"Bombay sliding window\" refers to a specific type of sliding window, typically made of aluminium, characterized by its horizontal sliding operation and often found in residential settings. These windows are named for their association with the city of Bombay (now Mumbai) and are known for their modern design and durability.Sliding Operation: The window slides horizontally along a track, either single or double-track. Material: Commonly made of aluminium, offering a lightweight yet durable option. Usage: Primarily used in residential buildings. Surface Treatment: Often powder coated for enhanced durability and aesthetics. Appearance: Available in a range of colours and designs, with a modern aesthetic.Size and Dimensions: Rectangular or square shapes, with common dimensions like 1200mm x 1200mm. Glass: Can accommodate various glass thicknesses, such as 5mm clear float glass. |
| 107 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately |
| 108 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. |