Tender For Provision Of Storage Accommodation At Island Grounds Under Ge Chennai; 1 Surface dressing n,exc 15cm deep and averaging 15cm deep & getting out in soft & loose soil complete all as specfied and directed. 2 Surface excavation n,exc 30cm deep and averaging 15cm deep & getting out in hard & dense soil complete all as specfied and directed. 3 Excavation in trenches n,exc 1.5m wide and n,exc 1.5m in depth,etc and getting out Soft/loose soil for foundation etc., n exc 10 sqm on plan complete all as specifed and directed. 4 Excavation in trenches n,exc 1.5m wide andexc 1.5m in depth,etc and getting out Soft/loose soil for foundation etc., n exc 10 sqm on plan complete all as specifed and directed. 5 Excavation in trenches n,exc 1.5m wide and n,exc 1.5m in depth,etc and getting out hard/dense soil for foundation etc., n exc 10 sqm on plan complete all as specifed and directed. 6 M&L PCC 1:4:8 type D2 ( 40 mm graded aggreage ) as in foundation filling and mass concrete complete all as specified and as directed. 7 M&L Mild steel TMT bar of 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing clips complete all as specifed and as directed. 8 All as per item no.5 above,but5mm diaand over upto and including 10mm dia in stirrups, spacer and binder complete all as specifed and as directed. 9 M&L forreinforced cement concrete design mixM-30 using 20mm graded aggregates for rafts,footings ,foundation beams , plinth beams,base for columns etc and mass concrete complete all as specifed and directed. 10 M&L for reinforced cement concrete design mixM-30 using 20mm graded aggregates as in columns, pillars, piers, post and strutscomplete all as specified and directed. 11 M&L for reinforced cement concrete design mixM-30 using 20mm graded aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 12 M&L for reinforced cement concrete design mixM-30 using 20mm graded aggregates in slab supported on walls, beams and colums in floors,roofs ,landing ,balconies,canopies,deck slabs and in shelvesand the like complete all as specified and directed. 13 M&L for reinforced cement concrete design mixM-30 using 20mm graded aggregates in chajjas complete all as specified and directed. 14 M&L for reinforced cement concrete design mixM-30 using 20mm graded aggregates in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres etc., complete all as specified and directed. 15 Use and waste of formwork to sides of concrete foundations, footing ,bases of columns, raft and raft beams, sides and soffits if any of foundation andplinth beams and similar work; vertical to batter make rough finished surfaces complete all as specifed and as directed. 16 Use and waste of formwork to sides ofpillars, posts, struts, piers, columns and stanchions and similar work; make rough finished surfaces complete all as specifed and as directed. 17 Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, also splays between floors and beams; make rough finished surfaces complete all as specifed and as directed. 18 Use and waste of formwork to suspended slabs such as roof slabs, floor slabs, floor slabs landings and similar work; not exceeding 200mm thick; make rough finished surfaces complete all as specifed and as directed. 19 Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs n exc 20cm wide sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed. 20 Use and waste of formwork to chullah hoods, chajjas, troughs and similar items includingedges complete all as specified and as directed. 21 Use and waste of Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed. 22 M&L for Pre Antitermite treatment to the backfill in contact with foundation at the rate of 7.5ltrs of emulsion per sqm of vertical surface (Area of sub structure in contactwith backfill to be measured) complete all as specified and directed. 23 M&L for treating the top surface of filled earth at the rate of 5ltrs of emulsion per sqm ofsurface complete all as specified and directed. 24 M&L for treating the soil under plinth protection at the rate of 5ltrs of emulsion per sqm ofsurface area complete all as specified and directed. 25 Returning filling including Spreading and leveling with excavated earth including watering removing in layers n,exc 25cm thick complete all as specified and directed. 26 M & L for pre cast cover slab in RCC 1:2:4, type B1, using 20mm graded stone aggregatefor manhole, set in cement mortar 1:6 including necessary form work complete all as specified.Note : Reinforcement steel will be measured and paid separately. 27 Removing excavated material n. exc 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and all as specified. 28 M&L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specifed and as directed. 29 M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specifed and as directed. 30 M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed. 31 M&L for rendering 15mm thick in CM 1:4 in two layers 5mm thk using WPC over 10mm thick on brick work/concrete wall surface and finished even and smooth without using extra cement complete all as specifed and as directed. 32 M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick concrete surfaces and finished fair and even complete all as specified. 33 Supply only Liquid water proofing compound (Make SIKA/ FOSROC /CHOKSEY) 34 M&L for rendering 10mm thick in CM 1:6 on brick work/concrete wall surface and finished even and smooth without using extra cement complete all as specifed and as directed. 35 M & L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick concrete surfaces and finished fair and even complete all as specified. 36 M&L for rendering 5mm thick on concrete surfaces of ceiling in cement mortar 1:3 including finished even and smooth without using extra cement complete all as specifed and as directed. 37 M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. 38 M&L for hard core of gauge n,exc 63mm, deposited , spread and levelled in layers n,exc 15cm thick, watered and rammed to a true surface broken stone. 39 M&L for 100mmthick cement concrete type D-2 1:4:8 as in floor/sub base complete all as specifed and as directed. 40 M&L 100mm Cement concrete1:5:10 type E2 using 40 mm graded stone aggregate thick as in sub base in path / hardstanding complete all as specifed and as directed. 41 M&L for 25mm thick PCC 1:2:4 type B0, (12.5mm graded aggregate) as in flooring complete all as specified and directed. 42 M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishingsurface even and smooth without using extra cementcomplete as specified and directed. (Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and every turning/ corners.) 43 M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with Grey cement and no pigment over 15mm thick screed bed of CM1:4complete all as specified and directed. 44 M&L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed in 1:4 screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed. 45 M&L for Kota stone slab 20-25mm thick in steps, skirting, dado and pillar laid over 15mm thick cement screed in 1:4 including pointing, moulding the edges in white cement (1:2) using marble dust with admixture of pigment to match with shade of kota stone complete all as specified and directed. 46 M & L for Non skid ceramic coloured joint free tile 7 to 8 mm thick Concept tiles design as approved (Square or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqmin floors etc of pattern as approved over and including 15 mm thick screed bed in Cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. 47 M&L for glazed coloured ceramic Concept designer tiles of7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE,fixed in vertical surfaces such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick all as specified and directed. 48 M&L for preparation of new concrete surface by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as directed:-(a) Applying Ist course of 15 mm thick cement screed in CM 1:4 over concrete surface.(b)Applying 2nd course of bituminous primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(c)Applying 3rd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(d) Applying 4th course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufacturers instructions. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, complete all as specified and directed. 49 Cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under.(a)Applying 1st course of bituminous (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed.(b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm.(c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufacturer instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. Note: All above treatment will be measured as one unit of square metre and paid accordingly.Note:- WPC will be measured and paid separately. 50 Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make: APEX ofAsian or equivalent of shalimar / Nerolac/ Berger. 51 M&L for three coats of white washing on newly prepared wall surfaces complete all as specified and directed. 52 M&L for three coats of white washing on newly prepared ceiling surfaces complete all as specified and directed. 53 Preparation of new plastered surface of walls and applying two coat of cement base paint over one coat of chalk whitening complete all as specified and directed. 54 M&L for Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.supplied and fixed 55 M&L for Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed. 56 S&F Plain framed, panelled shutter 35mm thick (two panel) with lock rail & panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. 2nd Class HW rail & style of size as per IS: 1003 (Part I), kiln seasoned & chemically pressure treated complete all as specified and directed. 57 S&F Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge mitredcut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall in repairs by drilling 100mm long MS screws using PVC fastener all as per specification and directed. 58 S&F Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing and all as directed. 59 S&F Butt hinges, 100mmsize extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 medium weightcold rolled mild steel etc., complete all as specified and directed. 60 S&F Butt hinges, 100mmsize medium weightcold rolled mild steel Etc., complete all as specified and directed. 61 S&F Aluminium anodisedbarrel tower bolts of extrudedsection 150mm long all as specified. 62 S&F Aluminium anodised barrel tower bolts, extruded section of size 200mm long all as specified. 63 S&F Aluminiumhandlescast typeanodised 125 mm size complete all as specified and directed. 64 S&F Aluminiumhandlescast typeanodised 150 mm size complete all as specified and directed. 65 S& F Aluminium alloy, anodised sliding door bolts 300mm long with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified and as directed. 66 S& F 140 mm over all length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed infloor complete all as specified and directed. 67 M & Lstainless steel curtain rodswith L clamps and with suitable globe brackets and brass screws all as specified 68 M&L for applying two coat of Synthetic enamel paint over a coat of pink primerforwooden surfaces including necessary preparation of new wooden surfaces of any description exc. 10cm width or girth complete all as specified and directed. 69 M&L for applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and directed. 70 S&F aluminium powder coated sliding window (for width 1.00 above and openable for below 1.50 M width)using aluminium section weighing not less than 0.495 Kg per RM for frame and 0.48 Kg per RM for sliding shutters includingaluminium anodised snap beads, screws andfixed alongwith same sectionin three rolling sliding shutters two for fully glazed with 5mm thick tinted glass fixed with glazing clips, and one for wiremesh shutters) etc(The rate is inclusive of all fixings of builders hard ware such as wirmesh hinges, bow handles, locking arrangements etc complete all as directed by Engr-in-Charge. 71 S&F aluminium powder coatedventilators using aluminium section weighing not less than 0.48 Kg per RM for frame louversaluminium anodised snap beads, screws andfixed alongwith with 5mm thick frostes/pin headed glass fixed with glazing clips, and one for wiremesh shutter fixed on frame etc(The rate is inclusive of all fixings of builders hard ware such as wirmesh, hinges, bow handles, locking arrangements etc complete all as directed by Engr-in-Charge. 72 S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings, including drilling and necessary welding to reinforcement and filling with PCC 1:2:4 Type B0 1:2:4 framework of water tanks & similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. 73 M&L for Second class Hard wood,plain solid straight chowkats and frames rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fitted all as specified and as directed. 74 M & L for PCC 1:2:4 type B-0 using (12.5 mm graded crushed stone aggregates ) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, filling in steel frames,kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and directed. 75 M & L for providing PCC 1:3:6, type C1 (using 20mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified. 76 M & L for providing PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in surface channel complete all as specified. 77 M & L Providing precast cement concrete type B0 1:2:4( 12.5mm graded crushed stone aggregates) set in CM 1:4 as inlouvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed. 78 S & F12mm thickplywood, grade BWR,fixed with screws to timber frame worktype BB with decorative laminate type1 0.90mm thick of surface finish colour and pattern as approved and other side white lamination type 1 , 0.5mm thick fixed with approved adhesieve as per manufacturers instructions complete all as specified and directed. 79 S & F 18 mm thick Prelaminated Particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed. 80 M & L for 6mm thick external teak wood lipping over 18/19mm thcik particle board/plywood fixed with nailscomplete all as specified and directed. 81 S&F continuous (piano)hinges mild steel,bright finish or electro galvanised width of flaps (when open)in mm 30mm complete all as specified and directed. 82 Supply and FixLocks, drawer, cupboard shutters grade I, size 75 mmBrass4 levers complete all as specified and directed. 83 S & F stainless steel Cabinet Hinges/self closing hinges (Bombay Hinges) complete all as specified and as directed 84 S & F Magnet closures to cabinet cupboards complete all as specified and as directed 85 M&L for small articles such as hold fasts etc. of Flat Iron 25 x 3, Grade confirming to Fe-290 Gde E-165 complete all as specified and as directed 86 M&L for preparing small articles such as hold fasts, end of posts etc. of area n.exc 0.1Sqm and treated with Cresote Oil/ black bituminous paint etc complete all as specified and as directed 87 M&L preparing of wood and wood based materials, steel, and iron work, new or old and treating ends of posts, backs of chowkats, etc, area tarred exc 0.1 sq m but n exc 0.5 sq m each and treated with tar or coat tar black paint complete all as specified and as directed 88 M&L for Type C1 1:3:6 (20mm graded aggregate) for fixing of hold fast complete all as specified and directed. 89 M&L for Type B0 1:2:4 (12.5mm graded aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves, filling in steel frames and the like complete all as specified and directed. 90 Supply & Laying of CPVC Pipes 20mm outer dia pipeSDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all as specified and directed. 91 Supply & Laying of CPVC Pipes 25mm outer dia pipeSDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete all as specified and directed. 92 S & F Vitreous china wash down water closet (pedestalpattern) incl seat cover white (excluding fixing bolts flushing cistern and flush pipe ) as specified 93 M & L for 150mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified & as directed. 94 M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) for concrete bed to drain pipe including packing under and haunching against the sides of pipes laid and tested for 150mm dia pipes, all as directed. 95 S&F PVC low level flushing cistern 10 ltrs capacity with complete accessories, PVC flush pipe, PVC over flow pipe, etc. and connected to water closet as per manufacturers instruction and asdirected by the Engineer in charge including removal of existing cistern etc. complete all as specified and as directed 96 S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrsand S&F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe complete all as specified and as directed 97 Supply and fix25mm bore Gun metal globe / Gate valve conforming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings/ fixutres like nipple, union etc, complete all as specified and directed. 98 S&F 15mm dia bib taps fancy type, chromium platedwith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule as specified 99 S&F 15mm dia pillar taps fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes as specified 100 S&F 15mm dia Brass stop valves/Angle chromium plated, fancy type with long shank and cup concealed type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union all as specified. 101 S&F health faucet (hand shower with 1 M flexible tube) with wall hook, chromium plated complete all as specified and as directed. 102 S&F 15mm PVC connection 450mm long of superior quality as specified. 103 S&F soap dish, matt finished chromium plated (MCH/Colour CP) complete all as specified and directed. 104 Supply and Fix looking mirror 600mm x 450mm bevelled edgeon selected quality mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and framed with aluminium channel all round etc., complete 105 S&F PVC waste pipe for wash hand basin/Urinal (size 31/32mm x 800mm length) complete all as speified and directed 106 S&F Tubular towel rail, brass chromium plated 20mm diaD type, 60cm long between flanges, complete all as specified and directed. 107 S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, all as specified and directed. 108 S & F PVC (SWR) pipes 110mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor etc complete all as specified anddirected. 109 S&F PVC (SWR) pipes in spouts etc., single socketed in any length with rubber ring joints laid in trenches or in floors etc of 110mm dia complete all as specified anddirected. 110 S & F PVC (SWR) pipes 75mmsingle socketed, in any length with rubber ringjoints fixed to walls /floor complete as in spouts etc complete all as specified anddirected. 111 S&F PVC (SWR) bends with oval access door 110mm complete all as specified anddirected. 112 S&F PVC (SWR) bends with oval access door 75mm complete all as specified anddirected. 113 S&F PVC (SWR) vent cowl 110mm complete all as specified anddirected. 114 S&F PVC (SWR) juncton single (single T ) equal or un equal withaccess door 75 mm complete all as specified and directed. 115 S&F PVC (SWR) juncton single (single T ) equal or un equal withaccess door110mm complete all as specified anddirected. 116 Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid) 117 Supply and laying burnt bricks, old size, sub class B, laid flat adjacent to each other, perpendicular to cable with width equal to length in trenches for protection of cable all as specified and as directed. 118 Supply and lay GI tube light grade 40mm bore with all fittings laid in trenches/ floor suitable for road crossing etc., complete all as specified and as directed. Note: Excavation and earth work required shall be measuredand paid separately. 119 Supply and lay in trenches,under road/ floors/ along poles or fixed on wall etc. ofXLPE insulated, screened, PVC bedded, galvanised strip or wire armoured, heavy duty LT,UG cable with aluminium conductor, 1100 volts grade of cross sectional area 50 Sqmm 3.5 core including connecting up using suitable size aluminium lugs testing and commissioningall as specified and directed. 120 Cutting existing GI water tubing of size 50mm in position for insertion of Tee of 50 x 50 x 40 mm sizefor bore of pipe GI 40 mm including excavation complete all as specified and directed 121 Supply and lay galvanised steel water tubing 40mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., laid in trenches complete all as specified anddirected. 122 Supply and lay galvanised steel water tubing 25mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc.,fixed complete to walls and ceilings or laid in floors complete including all as specified anddirected. 123 Supply and fix40mm bore Gun metal globe / Gate valve conforming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings/ fixutres like nipple, union etc, complete all as specified and directed. 124 M&L for point wiring of size 1.5 sqmmwith PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through new non metallic rigid PVC conduit including accessories,including cutting/chasingconcealed in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for complete for :- (a) one light point controlled by one switch 125 (b) one fan/exhaust point controlled by one switch 126 (c ) one 3 pin socket outlet 5 amps on the same board controlled by one switch. 127 (d)one 3 pin socket outlet 5 amps on independent board controlled by one switch. 128 (e) one bell/buzzer point controlled by one bell push 129 As per above items No 124 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed. 130 As per above item No. 124 for One 3 pin socket outlet. 15 amps, independent, with cables 4 sq. mm size complete all as specified( for Geyser ) 131 S& F for modular cover plate with frame 3 module complete all as specified and directed by Engr-in-Charge 132 S& F for modular cover plate with frame 4 module complete all as specified and directed by Engr-in-Charge 133 S& F for modular cover plate with frame 6 module complete all as specified and directed by Engr-in-Charge 134 S&F modular switches suitable fortype AC 240V, 6 amps 1 modulecomplete all as specified and directed by Engr-in-Charge 135 S&F modular socketssuitable fortype AC 240V, 6 amps 2 modulecomplete all as specified and directed by Engr-in-Charge 136 S&F modular switches suitable fortype AC 240V, 16 amps 1 modulecomplete all as specified and directed by Engr-in-Charge 137 S&F modular power sockets suitable fortype AC 240V, 16 amps 2 module complete all as specified and directed by Engr-in-Charge 138 S&F modularfan regulator suitable fortype AC 240V, 2 modulecomplete all as specified and directed by Engr-in-Charge 139 S&F modular bell switchsuitable fortype AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge 140 S&F call bell of multi music type A/C 230 voltscomplete all as specified and directed by Engr-in Charge 141 S&F ceiling rose , polycarbonate, isolated bodywith 2 to 3 terminalscomplete all as specified and directed by Engr-in Charge 142 Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200mm sweep. Five star rated with brushless direct current motor, complete all as specified and directed 143 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers , complete all as specified and directed 144 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 225/250m complete all as specified and directed 145 S & F 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed by the Engr-in-Charge. Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or equivalent Philips/Bajaj. 146 S & F 10 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed by the Engr-in-Charge. Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or equivalent Philips/Bajaj. 147 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified and directed 148 S&F MCB Power unit with 4 module steel box consisting of 3 pin 24 Amps socket with Plug top and MCB SP 25 Amps, suitable for operation of AC & Geysers etc., (Make :- Havells/Legrand/Anchor) 149 S&F sub main wiringcomplete with two runs of 10 sqmmPVC insulatedunsheathed single core multistrand copper conductorcable of 1100 volts grade drawnthrough new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceilingwith one run of 10 sqmm PVC insulatedunsheathed copperconductorcable as earth continuity conductor all as specified and directed by Engr-in-Charge.Note:- two runs of PVCinsulatedcable 10 sqmm+ one run 10 sqmmof earth wire and one run of conduit including accessories shall be measured as one length. 150 S&F sub main wiringcomplete with two runs of 4 sqmmPVC insulatedunsheathed single core multistrand copper conductorcable of 1100 volts grade drawnthrough new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceilingwith one run of 4 sqmm PVC insulatedunsheathed copperconductorcable as earth continuity conductor all as specified and directed by Engr-in-Charge.Note:- two runs of PVCinsulatedcable 4 sqmm+ one run 4 sqmmof earth wire and one run of conduit including accessories shall be measured as one length all as specified and directed (fo AC point) 151 S&F MCB distribution board made ofCRCA sheet, powder coatedpaint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 6 way MCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection complete all as specified and directed 152 S&F MCB distribution board made ofCRCA sheet, powder coatedpaint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection complete all as specified and directed 153 S&F MCBTPN100Amps 415 Volts C-Curvecompleteall as specified and directed by Engr-in Charge 154 S&F MCBSPN40-63Amps 415 Voltscompleteall as specified and directed by Engr-in Charge 155 S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts completeall as specified and directed by Engr-in Charge 156 Earthing complete with galvanisedsteel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion. 157 Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed