| 1 | Excavating in trenches n\"exc 1.5 m width and n\"exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n\"exc 10 sqm on plan and n\"exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Excavating in post holes (or similar holes) in hard/ dense soil, each n.exc 0.5 cum, getting out and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed. |
| 3 | M&L for PCC (1:4:8) Type D2 ( using 40 mm gradedstone aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed. |
| 4 | M&L for brick work with old size full bricksubclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 5 | M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed. |
| 6 | M&L for formwork for rough finish to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 7 | M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 8 | M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 9 | S&F Pre-painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa, AZ-150 as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, AZ-150 as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. |
| 12 | Removing excavated materialn.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 13 | S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed.Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. |
| 14 | M&L for twocoats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or grith complete all as specified and directed. |
| 15 | M&L for hard core of broken boulders/stone of gauge n exc. 63 mm, deposited, spread,and levellled in layers water andrammed to a true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed. |
| 16 | M&L forPCC (1:3:6) type C2, (40 mm graded stone agg) as in sub base of floor/ hardstanding/ footpath complete all as specified and directed. |
| 17 | M&L for 40 mm thick PCC (1:2:4) type B1(20 mm graded stone agg) as in sub base of flooring /hard standing complete all as specified and directed. |
| 18 | M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, complete all as specified and directed. |
| 19 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and smooth with out using extra cementcomplete all as specified and directed. |
| 20 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:4) surface finished even and smooth with out using extra cementcomplete all as specified and directed. |
| 21 | S&F factory made steel windows with side hung shutters (glazed and gauged shutter both) including box type hinges with steel handle,Z-section handle and steel peg stay complete with glazing bars, dovetailed or welded including a shop coat of red oxide zinc chrome primer complete all as specified and directed.Note :- (i) Measurements shall be taken and paid compositly for frame, glazed and gauged. (ii) Grill shall be measured and paid seperately under respective item. (iii) No extra claim shall be entertained on this ground. |
| 22 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden/ PVC/ aluminium beading, in square n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 23 | S&Fstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or wire staples complete all as specified and as directed. |
| 24 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed, barred iron door, ladders, fencing work ect. conforming to Fe-290 Gde E-165 complete all as specified and directed.Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account. |
| 25 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints and fixed to wall of following size complete all as specified and as directed :- |
| 26 | 75 mm bore |
| 27 | S&F PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of following size complete all as specified and as directed :- |
| 28 | 75 mm bore |
| 29 | S&F stack clamps out of 40 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for following bore of pipe complete all as specified and directed :- |
| 30 | 75mm bore pipe |
| 31 | S&F Stainless Steel non power driven roof top turbo ventilator of fan size 600 mm with base of polycarbonate material complete all as specified and directed. |
| 32 | M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit \"medium grade\" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box suitable for modular fixture with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii)If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding. |
| 33 | One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch. |
| 34 | One 5 pin socket out let 5/6 Amp on independent board. |
| 35 | One 5 pin socket out let 5/6 Amp on same board. |
| 36 | Descrition same all as per item No 29 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed. |
| 37 | S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. |
| 38 | S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. |
| 39 | S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. |
| 40 | S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specifiedand directed. |
| 41 | S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed. |
| 42 | S&F surface mounted LED luminiare 20 watt 4 feet with all accessoried having polycarbonate extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circut protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen perwatt, Inverter LED batten with square profile, inbuilt Lithium Ion battery with charging time 8-10 hours and back up time up to 4 hours, 6500 K internally pre-wired through flexible wire connection with ceiling rose complete all as specified and directed.Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period. |
| 43 | S&F LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electric connection with 1.5 Sqmm, 3 core, PVC insulated copperconductor cable 1100 Volt grade complete all as specified and as directed. |
| 44 | S&F exhaust fan steel body with louver shutter and frame, heavy duty, AC, single phase, 230 V, of size 300 mm sweep, 900 RPM and connecting up including provision of cable from ceiling rose/ connector to exhaust fan complete all as specified and directed. |
| 45 | S&F connecting & testing distribution board of sheet metal enclosures single door, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected:- |
| 46 | DB SPN,4 way |
| 47 | S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps ratinghaving following capacity complete all as specifiedanddirected:- |
| 48 | DB TPN, 4 wayMake : Legrand Cat Part No. 5076 70 or equivalent others make as specified. |
| 49 | S&F connecting & testing MCB, 230V/ 415Vwith rupturing capacity 10 KA of following capacity complete all as specified and directed:- |
| 50 | MCB 6 to 32 Amp, SPN, \"C\" series/ curve, |
| 51 | MCB 6 to 32Amp, SP, \"C\" series/ curve, |
| 52 | S&F connecting & testing MCB, 230V/ 415Vwith rupturing capacity 10 KA of following capacity complete all as specified and directed:- |
| 53 | MCB 16 to 32 Amp, TPN, \"C\" series/ curve, |
| 54 | S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH,PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:-NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii)The quoted rates shall be deemedto be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface.The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs. |
| 55 | 2x4 Sqmm+ 1x4 Sqmm earth wire with PVC conduit 20mm dia or more |
| 56 | 2x2.5 Sqmm+ 1x2.5 Sqmm earth wire with PVC conduit 20mm dia |
| 57 | S&F LED hi- bay light fitting of 100 Watt,having IP 66 degree of protection, cast aluminum alloy material and heat and impact resistance toughen \"A\" clear glass having anti corrosive epoxy powder coated finish with appropriate driver PF> 0.98 and LED lumen efficiency > 120 lumen per watt and 6500K colour temp complete with all accessories pre wired and including connected up with three core flexible copper conductor cable with suitable size complete all as specified. |
| 58 | S&F Type -Four Pole Al Busbarhaving IP 42 protection with enclosure having rated voltage 415 Volt 50 Hz and current rating 100 Amp with 4 out going ways with all necessary electrical connections complete all as specified and directed. |
| 59 | S&F complete air termination assamblycomparising of single pointed air termination aluminium rod 12mm dia, 300mm long, GI pipe (20mm dia and 1.5m length),GI socket/reducer ( 20mm dia), aluminium gutty with inner and outer threaded to fix the rod including PCC/ brick massonry block & wooded gutaka for fixing stand post of GI pipe in PCC/ masonary block complete all as specifiedanddirected. |
| 60 | S&Faluminium strip 25 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed |
| 61 | S&F Air Circulator fans/ Wall fan 230 volts single phase, oscillating 450 mm sweepincl suitable arrangement forfixing on wall by means of nuts & bolts etc as required and complete. |
| 62 | M&LGI Pipe/ Tubes \"light grade\" galvanised with all fitting and fixed of size 40 mm dia bore all as directed.Note: one meter of pipe fixed with each pointer. The connection arrengement of pipe and aluminium pointer by means of clamp, nuts & bolts, welding as required on ground included in the quoted rate. |
| 63 | M&Lfor sackle type insulator, procelain vitreous, 150 mm high and 150 mm dia white or brown or green,wtih 38x5mm steel strap and bolts, working pressure 11000 volts complete all as specified and directed. |
| 64 | S&F ACSR conductor (Rabbit) for lightning protection over shed/ bldg all as directed |
| 65 | M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earthstrip of size 32x6 mm as earthing lead by means ofbolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009)withconected to eath test point including adequate quantity of charcoal dustand comman salt, PCC (1:3:6) type C-1chamber andfor earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both wayswith MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for wateringand 40mm dia medium grade GI pipe as earth lead protection pipe completeall as specified and directed.Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor. |
| 66 | S&F/Laying, connecting and testing of HT cable XLPE insulated screened PVC badded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 11KV (Earthed) as per IS 7098 (Part-II) with stranded aluminium conductor offollowing size complete all as specified and directed:-Note:- 1. The earth work, GI pipe shall be measured and paid sepretely.2. Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc. |
| 67 | 70Sqmm, 3 core. |
| 68 | M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. |
| 69 | Supply and laying cable protection bricks, common burnt clay sub class \"B\" designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. |
| 70 | M&L for road cutting for laying cable and through GI Pipe of suitable size making good with PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) of 150mm X 100mm inrespect ofwidth and thickness complete all as directedby Enger -in- charge. |
| 71 | S&F galvanized steel water tubing(GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :-Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc. |
| 72 | 50mm bore |