}

Tender For Conversion Of Rural Scs To Ssk-Health Wellness Center At Howrah Harishpur(S) Sc,Udaynarayanpur, udaynarayanpur-West Bengal

District Health And Family Welfare Samiti has published Tender For Conversion Of Rural Scs To Ssk-Health Wellness Center At Howrah Harishpur(S) Sc,Udaynarayanpur. Submission Date for this Tender is 11-09-2025. Building Work Tenders in udaynarayanpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

51038429
Tender For Conversion Of Rural Scs To Ssk-Health Wellness Center At Howrah Harishpur(S) Sc,Udaynarayanpur
Tender
Indian
West Bengal
Udaynarayanpur
11-09-2025

Tender Details

Tender For Conversion Of Rural Scs To Ssk-health wellness center At Howrah Harishpur(S) Sc,Udaynarayanpur2 Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. In ground floor including roof. Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor 125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts), reassambling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (b) 20 mm. thick plaster (1:6) i) In ground floor (c) 15 mm. thick plaster (1:6) 1) In ground floor (c) 10 mm. thick plaster (1:4) i) In ground floor (ceiling) Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturers specified rate) for concrete of various grades. Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm x 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrrje) 1) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/Sq.m white cement for joint filling with pigment. Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia, rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass/copper hooks including pointing in cement mortar (1:2) (1 white cement: 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (b) Area of each Granite slab above 1.00 Square meter. Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35mm thick shutters (single leaf) Supplying, fitting & fixing of 2-Track/3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to 15 733-1983 & 15 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film i) Natural White a) 2-track sliding windowe Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units (iv) fixed glazing Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. viii) 4mm thick coloured/tinted/smoke glass Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vi) 100 mm x 50 mm x 1.25 mm (For Door) (v) 75mm. x 60mm. X 3.15mm. tron socket bolt of approved quality fitted and fixed completed. (d) 225 mm long x 10 mm dia. Bolt Anodised aluminium decorative handle [hexagonal/fluted) of approved quality fitted and fixed complete. (i) 150 mm plate x 10 mm dia rod x 12 mm hexagonal/fluted. (i) tron hasp bolt of approved quality fitted and fixed complete with 16 mm. dia. Rod with centre bolt and round fitting (b) 250 mm long Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded PVC. multichamber hollow section having dimensions 60mm x 50mm 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. PVC 26 Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos, built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.5. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/-0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100mmx20 mm with wall thickness of 1.2 mm (+/-0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges/hasp bolt/tower bolt/door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete. The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc. i) in ground floor Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisły IS: 4020 door testing performance criteris (1) 66mm x 90mm Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick (a) Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete in all floors: (i) 4mm, thick (weighing 7.4 kg/sq.m.) (b) Rendering the surface of walls and celling with white cement based wall putty of approved make and brand (1.5mm thick) Removing old scales, blisters etc. of interior surface of walls, relling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (In Ground Floor) a) One coats Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. Two Coats Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. In Ground Floor: a) One coats. Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. c) Super Protective 100% Acrylic Emulsion. (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs. In Ground Floor (ii) Grill weighing 10-16 Kg./sq.mtr and above. (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. including using of approved putty etc. on the surface, if necessary. 1) On timber or plastered surface: With super gloss (hi-gloss) Two coats (with any shade except white) a) In ground floor ii) On steel or other metal surface: With super gloss (hi-gloss) Two coats (with any shade except white) a) In ground floor Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). i) In Roof a) With 0.5 mm thick steel M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161-1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. i) For trusses spanning up to 12.00 m 50mm Dia Pipe (Heavy type) Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./W.I. gate etc. with point welding at not more than 150 mm apart complete in all respect as per design including cost of all labour and materials. Repairing collapsible gate by cutting out all ribets as necessary re assambling all members including welding pieces of channels, strigthing bend bars & rebating with new revets and fitting in position & painting two coats Painting with ready mixed Black Japan of approved make & brand including smoothing surface (b) two coats Supplying fitting & fixing PVC pipes of approved make of (medium duty) conforming to ASTMD-1785 and threaded to match with G.1. pipes as per IS 1239(Part-1) with all necessary accessories, specials vir. socket, bend, Tee, Union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the center line measurements of the total pipe line including all specials. No separate will be made for accessories, specials. Payment for painting will be made separately). b) For Concealed Work 15mm 20 mm (b) For Exposed Work PVC Pipes 40mm dia Supplying, fitting and fixing bib cock or stop cock. (b) (ii) Chromium plated lib Cock short body (Equivalent to Code No.511 & Model-Tropical/Sumthing Special of ESSCO or similar brand) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No.5053 & Model-Florentine of Jaquar or similar brand) Supplying fitting & fixing gunmetal wheel Valve of approved brand & make tested to 21 kg per squire centimeter. (25mm dia) 40mm dia Supplying, fitting and fixing whitevitreous china Best quality approved make Wash Basin 550mmx400mm size Supplying, fitting and fixing pillar cock of approved make (1) CP Pillar Cock-15 mm. (Equivalent to Code No.-507 & Model-Tropical/Sumthing Special of ESSCO or similar brand). CP Pillar cock with 200 mm extended liver handed Supplying fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC couplin at one end fitted with necessary clamps. (1) 600 mm long Supplying, fitting and fixing approved brand P.V.C.CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (i) 600 mm long Supplying, fitting and fixing towel rail with two brackets (1) 25 mm dia and 600 mm long Supplying, fitting and fixing Anglo-Indian W.C. In white vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (b) With S trap (with vent) Supplying, fitting and fising 10 litre P.V.C. low-down cistern conforming to 1.5. specification with P.V.C. Fittings complete.C.I. brackets including two coats of painting to bracket etc. Supplying, fitting and fixing 32 mm dia flash pipe of approve make with necessary fixing meterials & clams complete. C.P flash pipe Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges Plastic (hallow type) white. Supplying, fitting and fixing best quality indian make mirror 5.5 mm thick silver as per ISI specification Frame size 550 mm x 400 mm Supply UPVC pipes (B type) and fittings conforming to IS: 13592-1992 A) (i) Single sacketed 3m length. b) 110mm A) (1) Single socketed 3m length. (a) 75 mm (B) Fittings ii) Plain Tee- 110 mm dia (B) Fittings ii) Plain Tee 75 mm dia )Bend-110mm dia x) Bend-75mm dia xi) Door Bend (T.5.) a)75mm (b) 110 mm Labour for fitting and fixing UPVC pipes for above ground work including cost of joint materials etc. fitting & fixing all necessary specials, cutting pipes, cutting holes in walls or RC floor where necessary and mending good all damages excluding the cost of masonry or concrete work if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for under ground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer in charge (A) Above Ground 1) 110 mm dia ii) 75mm dia ELECTRICAL WORK Supply & Fixing of 20 W, 240 V 4 ft single LED with box type fittings incl. all accressroies directly on wall with suitable size MS fastener Make-Philips fätings cat. Ref BN100C LED405-6500 PSU L120 GR, Fixing only single fluorescent light fitting complete with all accessories. directly on wall/ceiling with HW round block and suitable size of MS fastener [Analysed Rate Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/celling with HW block and ceiling plates, nipples etc. as required Supply & Delivery at site 9 watt LED Bulb, Efficacy> 90 lm/W, Base Cap:-822 (Make-Crompton] or equivalent of Havells, Philips etc. Approved by EIC Supply of 45 W, 240 V LED flood/street light on the roof of the header arm of the pole. Make- Philips SmartBright Street, BRP 052 LED 045 CW SLMR FG S1 PSU GR. [Analysed Rate) Fixing only outdoor/street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes/providing clamping arrangement & necy. Gl reducer as required. S&F 40 mm Gl pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl, painting etc. Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy, length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) [PWD/GS Page: C4 Item: 28] Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy, connections etc Supply & Fixing GI sheet (205WG) metal Cowl with MS flat iron frame & Gl wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Exhaust fan (12) Supply & delivery of Sweep:- 48 (1200mm) AC ceiling fan, 50-70 Watts, Speed:->-350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL/equivalent of EPC or USHA STRIKER PLUS or CROMPTON [Approved by EIC] Supply 500 mm 3 Blade Ceiling Fan (Black)(Make-Orient/Crompton) Supply of Sweep:-12 (300mm) sweep heavy duty, 50-60 Watts, Speed:->-900 RPM, Air delivery:->=1145 CMM, exhaust fan make: (Orient/EPC/Havells/Usha) [Approved by EIC] Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32 A(SP)(Make-Havells) Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection 32A(DP)(Make-Legrand) Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(2+4 way) (Maker-Crabtree/L&T) Supply and fixing of 240 V, 32 A DP Main Switch on flat iron frame on wall with nuts, bolts etc. Make- Havells [PWD/GS Page: D1 Item: 1 (a).] Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required(As per Drawing no. 470 of PWD Specification Book-May 1991) 2 bars 240 V, 63 A Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy, fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface) Average run 8 mtr Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision meke) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy, fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI/PVC switch board with 3/4 Module top cover plate on wall incl. necy, connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface) On Board Supplying & Fixing Gl Modular Switch Board of the following sizes complete with three no, suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 8 Module 4 Module 12 Module Supply & Fixing 240 V6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module Gi Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy, connections with PVC Cu wire and earth continuity wire etc. Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module Gi Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [UPS Board] Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with Indicator (Brand approved by EIC) & necy. Connections. [UPS Board] Supplying of 1.1 KV. Grade PVC insulated conductor of following cables (make: Polycab/Gloster/Havells) 25 sqmm 2 core (UD & MA Page-11 item no-1) -Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting Supplying and fixing compression type gland complete with brass -gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: For 2 core upto 25 sqmm Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 2 core 25 sqmm cable Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/flooras required and making connection to equipments with bolts, nuts, washers, cable lugs etc.as requiredand mending good damages [Stranded Gl wire 7/14 SWG] Excavation of soil for installation of Earth Electrode and filling & ramming [For Soft Soil] Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long Gi bolts, double nuts, double washers incl. S & F 15 mm dia Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium Gl pipe

Key Value

Document Fees
Refer document
Tender Value
INR 7 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail