| 1 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Supply of R.C.C. pole(size 0.15x0.10x1.80) 1.8 mtr. Height with 5 nos. hole/stepul for fixing of barbed wire all complete as per instruction of E/I. |
| 3 | Fixing of R.C.C. pole in 1:3:6 cement concrete in cement coarse sand and stone aggregate including digging pit of size 0.45x0.45x0.45m and supply of concrete including all labour T&P etc. complete as per instruction of E/I. |
| 4 | Supplyof twist type silver barbed wire with approximate weight of 140-150gram/meter complete as per instruction of E/I. |
| 5 | Fixing of barbed wire in fixed poles including all labour & T&P complete as per instruction of E/I. S.I.No-513 |
| 6 | Supply, fixing and hoisting of 6.00-7.00 m. spanCantilever Structure in position with one vertical post of 6.00 M. clear height from the top of R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick MS plate at bottom supported with 10 mm thick MS plate stiffners & two nos. 8 mm thick MS plates at top welded with structure of 40 mm NB (M) pipe comprising ofhorizontal, vertical & bracing pipe of 32 mm NB (M) as per structural design requirements & approved drawing with vertical & lateral clearance given in clause 802.2 & 802.3 including one coat of primer and two coats of synthetic enamel paint on the whole structure & installed as per clause 802.7 over a designed support system made up of concrete including excavation, lean concrete 1:4:8 cement, coarse sand and approved 20 mm grit and R.C.C. 1:2:4 with cement, coarse sand and approved 20 mm grit complete for fixing the complete structure in position as per direction of E/I charge. With 7 years warranty. Rates include design, fabrication, supply,transportation and erection of the signage structure inclusive ofalltaxes, royalty,etc. all T&P/machine material and labour required for proper completion of the work. |
| 7 | Retro Reflective Signs (Type-IV Sheet) for single sideProviding and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, aluminum composite panel (ACP) as base board. micro prismatic retro-reflective sheet and electro cut colored overlay film/latex printing. The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron. No panel size shall be more than one sqm and each panel shall be braced diagonally (one way only) with MS angle. The MS frame module shall have length not more than 3 mtr. The aluminum composite panel (ACP) shall have a thickness of 4mm with 0.5 mm thick skin of aluminum on both sides. The ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM. D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm |
| 8 | Supply and fixing of portable complex of 29\" x 15\" size of each room as per specification of attached quatation (Foundation, cabin, verandah, toilet, kitchen & transport complete) and as per instruction of engineer in charge complete in all respects but excluding GST. |
| 9 | Development of Camp Office area as per site and as per instructions of engineer incharge. |
| 10 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 |
| 11 | Providing and laying of interlocking concrete Block pavement having thickness 80 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) |
| 12 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR-16.69) |
| 13 | Providing and fixing of M.S. informatory sign board with frame of 40X40X5mm angle iron and diagonal braces of 25X5mm flat iron. 16 S.W. gauge M.S. Sheet shall be fixed on the M.S. Frame including one coat of ready mixed priming paint and two coats of apporved superior quality ready mixed paint on the whole structure and also painting letters on M.S. Sheet firmly fixed to the ground with 15 grade cement concrete 45X45X60cm B.G.L. Complete as per approved drawing and direction of Engineer-in-charge. (A.R.) |