| 1 | (A) SH: Demolishing Work |
| 2 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for replacing or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc. complete as per direction of the Engineer-incharge. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material with all lifts and upto 50 l lead etc. complete as per direction of the Engineer-in-charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge:In cement mortar. |
| 5 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:(13.30.2 ) With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 6 | Dismantling GS sheet roofing including ridges, hips, valleys, gutters wind ties etc. includingdismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 7 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 8 | (B) SH: RCC Work |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work upto plinth level: (4.1.2) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoplinth level.5.19.4 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement.5.2.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.20.4 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | (C) SH: Flooring Work |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 10.42.1 Soluble Salt Stainfree vitrified tiles 10.42.1.1 Size of tile 60x60 cm |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 10.42.1 Soluble Salt Stainfree vitrified tiles 10.42.1.1 Size of tile 60x60 cm |
| 16 | (D) SH: Brick Work |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 18 | First class brick work in foundation and plinth including cost of all materials as required complete:(6.1.2 ) In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 19 | (E) SH: Roofing Work |
| 20 | Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers fillled with white lead and including a coat of approved steel primer and two coats of aproved paint on overlappping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the coast of purlins, rafters and trusses and including cutting to size and shape wherever required.(11.1.2) 0.63 mm thick wih zinc coating no less than 275 gms/m2 |
| 21 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.(11.4.2) 0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 22 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(9.12 .1) Hot finished welded type tubes |
| 23 | (F) SH: Finishing Work |
| 24 | 12 mm cement plaster of mix(12.1.2) Cement mortar 1:3 (1 cement : 4 fine sand) |
| 25 | Neat cement punning. |
| 26 | Finishing walls wih water proofing cement paint of required shade of appproved brand and manufacture on old work (one or more coats) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 27 | Distempering with oil bound washable distemper of approved brand and manfacture and of required shade on old work (one or more coats), to give and even shade as required complete as per direction of the Engineer in charge. |
| 28 | Finishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.28.1 New work ( two or more coats applied @ 3.84 kg/10 sqm) |
| 29 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :(12.24.1) New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 30 | Finishing with epoxy paint ( one or more coats ) of approved brand and manufacture at all locations prepared and applied as per manufacturer\"s specification on old work including preparation of surface etc. as required complete as per direction of the Engineer in charge:On steel work. |
| 31 | Painting on G.S. sheet with synthetic enamel paint (one or more coats) of approved brand and manufacture of required colour to give an even shade on old work including preparation of surace as required complete as per direction of the Engineer in charge. |
| 32 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : (12.37.1) New work (two or more coats) including a coat of appropriate steel primer but excluding a coat of mordant solution |