Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling of floorhearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust, etc including brushing neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed. |
| 3 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick cement mortar 1:4 screed bed for laying of floor finishes complete all as specified and directed. |
| 4 | M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in skirting, dado and risers to steps, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering (backing coat) in cement mortar 1:4 complete all as specified and directed. |
| 5 | Material and labour for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering (backing coat) in cement mortar 1:4complete all as specified and directed. |
| 6 | M&L for machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick cement screed bed in cement mortar 1:4,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 7 | M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick backing coat in cement mortar (1:3) complete all as specified and directed. |
| 8 | Taking down chowkats or frames exceeding 1.50 sqm but not exceeding 4.00 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 9 | Taking down chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 10 | S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and directed. |
| 11 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement and fixing in the frame at site as per specification & drawing etccomplete all as specified and directed. |
| 12 | S&F Pressed steel frames for doors of frame size 105x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 13 | S&F Pressed steel frames for doors of frame size 125x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 14 | Material & labour for PCCtype B0 1:2:4 (12.5mm graded stone aggregate) for fixing hold fasts, angle, etc including necessary form work complete all as specified and directed. |
| 15 | Material & labour for PCCtype C-1 1:3:6 (20mm graded stone aggregate) for filling hollow portion of frame acomplete all as specified and directed. |
| 16 | S & F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 17 | S & F 35mm thick 2nd class hard wood factory made plain framed, panelled shutters (any number of panels) with lock rail and panel of 9mm BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces, the size of rails and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed |
| 18 | S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to recieved glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a), fitted to chowkats complete all as specified and directed |
| 19 | Supply and fixedstainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples including all cuttings, wastage etc, complete all as specified and directed. |
| 20 | S & F 100 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed. |
| 21 | S & F extruded aluminium alloy handles of size 150mm fabricated type anodised complete all as specified and directed. |
| 22 | S&F Aluminium anodised barrel tower bolt of extruded section, 200mm long and fixed complete all as specified and directed. |
| 23 | S & F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast alumimium alloy and fixed complete all as specified and directed. |
| 24 | M & L for 18 mm thick Medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed. |
| 25 | M & L for 18/19mm thick prelaminated particle board, interior grade, prelaminatedone side with decorative choice lamination and other side balancing white with lamination fixed with screw to timber frame work as in repair to cup board shutter and shelf complete all as specified and directed. |
| 26 | S & F 100 mm hasp and staple of aluminium andoised, safety type including bolts to hinges plate and fixed with screws completeall as specified and directed. |
| 27 | S & F brass helical door spring 300mm long including roller and roller plate complete all as specified and directed. |
| 28 | Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 Nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick plain glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc with the following section of frame and shutter complete all as specified and directed:-(a) Sections for shutter:- (i) \"H\" section: 39 x 20 x 1.20 mm thick (ii) \"Interlock\" section: 39 x 20 x 1.20 mm thick(iii) \"Edge & Bottom\" section: 41 x 20 x 1.20 mm thick (b) Section for frame:-(i) Top & Sides: 92 X 29.50X 1.20mm thick(ii) Bottom: 92 X 29.70 X 1.20mm thick |
| 29 | S & F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 30 | Dismantling Wallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed |
| 31 | M&L Anodised aluminium snap grid frame work for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified. |
| 32 | Supply and fix 6 mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and as directed.Note: Frame work for ceiling shall be measured and paid seperately |
| 33 | Taking up or down steel tubing 15 mm boreand connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 34 | Taking up or down steel tubing 20 mm boreand connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 35 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 36 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 37 | M & L for cleaning and removing all scale and dirt, etc, from 500 litre capacity tank and from mouths of circulating pipes, etc complete all as specified and directed. |
| 38 | S & F in repairs 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball (Minimum weight - 210 gms) screwed for iron pipe and fixed complete all as specified and as directed. |
| 39 | Supply and fix 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed complete all as specified and directed. |
| 40 | S&F in repair 600mm x 450mm PVC frame mirror of selected quality glass, mounted on 6mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 41 | S&F in repair wash hand basin, white flat back of size 550 x 400mm including 15mm dia fancy type pillar taps cast copper alloy chromium plated screwd down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts fitted to iron pipe,waste coupling, waste pipe and bracket, PVC connection pipe of 15 mm size with PTMT nuts of length 600mm, etc.including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 42 | S&F in repair sinks with drainage board made up of 1mm thick stainless steel kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 43 | S&F in repairs kitchen plate rackmade of stainless steel sheet not less than0.63mm thick of size 36\"x36\"10\" inch, the hooks for hanging the utensils should be of high quality steel complete all as specified and directed |
| 44 | S & F cordless transparent glass corner shelf9x 9 inch wall mounted complete all as specified and directed. |
| 45 | S&Fin repairs brass chromium plated shower rose 125mm size, including fixing to steel pipe or union complete all as specified and directed. |
| 46 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 47 | Supply and fixed in repairs ofvitreous china squatting pan of Orissa pattern size 580 mmx440mm white withP or S trap front or back inlet and integral foot restIncluding PVC valve less syphonic action flushing cistern type 10 litres capacity with inlet, ball valve, float and handle including bracket, white colour of approved make, flush pipe and PVC connection pipe of 15 mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 48 | S & F in repairs 15mm dia angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 49 | S&F in repair 15mm dia bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed. |
| 50 | M&L for uprooting of tree including roots from walls of bldgs and spraying with acid of required quantity complete from any location of bldg up to 4 storied height and making good disturbed surfaces with cement mortar (1:4) or PCC type C1(1:3:6) using 20mm graded stone aggregate including necessary scafolding completearea exceeding 1 Sqm but not exceeding 2 Sqm (girth of trees 5 to 10 cm) complete all as specified and directed by Engr in charge. |
| 51 | Demolition of precast concrete block walling set in cement mortar complete all as specified and directed. |
| 52 | Material and labour for precast cement concrete type C-1,1:3:6, (20mm graded stone aggregate) block masonry with solid blocks, exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed. |
| 53 | Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) of walls, chajja, fins, facia etc. any height mixed with water proofing compound (for 5mm thick finishing layer only) @ 3 % of weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement including taking down old plaster complete all as specified and directed.Note: (i) Water proofing compound will be measured and paid separately(ii) Cost of scafolding, any height are deemed to be inclusive in the quoted rate. |
| 54 | Supply only integral waterproofing compound |
| 55 | M&L for rendering 10mm thick in cement mortar (1:6) internal surfaces on fair faces of brick work or concrete surfaces, making finished even and smooth without extra cementincluding taking down of cement plaster complete all as specified and directed. |
| 56 | M&L for rendering 15mm thick in cement mortar (1:6) internal surfaces on other than fair faces of brick work or concrete surfaces, making finished even and smooth without extra cementcomplete all as specified and directed. |
| 57 | Material and labour for 5 mm thick rendering incement mortar (1:3)on fair faces of exposed/non exposed concrete surfaces such assoffits of slabs, chajja, facia and simillar work including mixing & application of integral water proofing compound as per manufacture instruction of finishing the surfaces fair and even including taking down of cement plaster of any description including racking out joints for for key scrubing with water complete all as specified and directed. |
| 58 | M&L Preparationj of oldtreated surfaces of steel of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 59 | M&L for preparation of new wall surfaces and applying two coats ofdistemper oil emulsion over a coat of alkali resistant primer complete all as specified and as directed. |
| 60 | Material & Labour for preparation of new wall surface applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 61 | Material and labour for two coats of white wash on newly plastered surfaces of ceiling surface including preparation of surfaces complete all as specified and directed. |
| 62 | M&L for complete removal of existing treatment on walls and applying two coats ofdistemper oil emulsion over alkali resistant primer complete all as specified and as directed. |
| 63 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including complete removal of existing treatment and Washing, rubbing down and stopping of distempered and painted surfaces. |
| 64 | Material and labour forcomplete removal of existing treatment and apply two coat of white wash on surfaces of ceiling including preparation of oldplastered surfaces complete all as specified and directed. |
| 65 | M&L for applying 1mm thick internal wall care putty on wall complete all as specified and directed. |
| 66 | Demolition of cement concrete(un-reinforced) of any description and in anypositionnot otherwise specifically provided for etc complete all as specified and directed. |
| 67 | M&L sunken treatment of Toilet/Bathroom as in following steps:i)Top of RCC slab in sunken portion includingperipheral beams shall be plastered with 15mmthick in cement mortar 1 : 3 using approved waterproofing compound @ 3% by weight of cement finished even and smooth using extra cement,curved at the junctions. ii)Apply two coats of epoxy resin/polymer modified cementations coating like brush bond of FOSROK/SIKA/Pedilite or equivalent, both on floor & beams.iii)Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyondouter surface of wall shall be provided.iv)Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab.Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE. |
| 68 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushedstone aggregate) as in filling to sunken floor (upto 04 storey building) complete all as specified and directed. |
| 69 | M&L for 20mm thick granite (of any type)work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed/bedding layer in cement mortar 1:4 and demolition of existing stone slab complete all as specified and directed. |
| 70 | Taking down eaves gutters, sewage lines andrainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swannecks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 71 | M & L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors including scaffolding complete all as specified and directed. |
| 72 | M & L for 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors including scaffolding complete all as specified and directed. |
| 73 | S & F 110 mm bore PVC (SWR) bends any radius with access door including scaffolding complete all as specified and directed. |
| 74 | S & F 75 mm bore PVC (SWR) bends any radius with access door including scaffolding complete all as specified and directed. |
| 75 | S&F 110mm dia PVC (SWR) junction single,(Single T) equal or unequal with access door including scaffoldingall as specified and directed. |
| 76 | S&F 75mm dia PVC (SWR) junction single,(Single T) equal or unequal with access door including scaffoldingall as specified and directed. |
| 77 | M&L for 100 mm PVC (SWR) nahani trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap complete all as specified and directed. |
| 78 | M&L for 100 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap complete all as specified and directed. |
| 79 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level) and removing debries from site of work complete all as directed by the Engineer-in-Charge. |
| 80 | M&L for 75 mm thick cement concrete type C-I 1:3:6using 20 mm graded stone aggregate as in plinth protection finished fair and even with using extra cementcomplete all as specified and directed. |
| 81 | M&L for cement concrete type C2 1:3:6 using 40 mm graded stone aggregate in surface channels and drains complete all as specified and as directed. |
| 82 | S & F trapezium/triangular shape colour coated UPVC gutter/runner drop for rain water drain in buildings of size not exceeding 150 mm dia with firmly attached down spout of suitable size discharging storm water into PVC SWR pipe of 110 mm dia and similar works etc complete allas specified and directed. Note: The quoted rate shall be deemed to be inclusive of down spouts, drop outlet, Elbow, End cap, Straight connecter, brackets, downspout couple, splash block, out site corner, clamps as required at site as per standard Engineering practice. |
| 83 | S & F weather boarding clean sawn/plain 25mm thick and 225mm wide (V jointed to give 20mm laps) to replace old decayed boarding including cutting out old pieces and removing old unserviceable boarding complete allas specified and directed.Note:-(a) The rate quoted are deemed to be inclusive of two coat of synthetic enamel paint including one coat of pink primer and scafolding work upto 14.00 m. |
| 84 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. |
| 85 | Excavation in trenches not exceeding 1.50 m wide and n exc. 1.5 m in depth; for foundation, etc, or for shaft, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 86 | M&L for providing cement concrete type B2, 1:2:4 (40mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed. |
| 87 | Material and labour for hard core with broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, wateredand rolled/ rammed to a true surface complete all as specified and directed. |
| 88 | Material and labour for 100mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed. |
| 89 | M & L for providing plain cementconcrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 90 | M&L for rendering 10mm thick in cement mortar (1:6) surfaces on fair faces of brick work or concrete surfaces, making finished even and smooth without extra cement complete all as specified and directed. |
| 91 | Material and labour for two coat of white wash on newly plastered surfaces of wall surface including preparation of new plastered surfaces complete all as specified and directed. |
| 92 | Removing surplus excavated materials (soils) upto a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 93 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil all as specified and directed |
| 94 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. |
| 95 | Material and labour for point wiring for One light/fan point controlled by one,one way switch, with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingPVC conduitsincluding necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed as below :-Note:-Rate forCutting, chieseling and making good the existingsurface for complete concealed wiring is deemed to be included in quoted rate, complete all as specified & directed. |
| 96 | All as per Sr. Item No. 94 herein-above but for One 5 Pin 5 Amps socket out let point onindependentboard. |
| 97 | All as per Sr. Item No. 94 herein-above but for One 5 Pin 5 Amps socket out let point on same board alongwith othersuitable switchs. |
| 98 | All as per Sr. Item No. 94 herein-above but for light point controlled by two, 2 way switch |
| 99 | All as per Sr. Item No. 94 herein-above but for bell point controlled by one push button switch. |
| 100 | All as per item No 94 here-in-before but using 2.5 sqmm PVC FRLS insulated copper conductor wire for connecting 15A socket on independent board complete all as specified and directed. |
| 101 | Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way complete all as specifed and directed. |
| 102 | Supply and fixing of switch piano flush type 240 Volts 15 Amps, SP, two way complete all as specifed and directed. |
| 103 | Supply and fixing of bell push piano flush type 240 Volts 5 Amps, one way, complete all as specified & directed |
| 104 | Supply and fixing of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) in independent board complete all as specified and directed. |
| 105 | Supply and fixing of socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) on same board complete all as specified and directed. |
| 106 | Supply and fixing switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) in independent board complete all as specified/directed. |
| 107 | Supply and fixing ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified and directed. |
| 108 | Supply & fixing ceiling fan regulator electronic,Deluxe,rotary, step type, 120/280 V complete all as specified and directed. |
| 109 | Supply and install new metering board powder coated Single door fabricated with 1.6 mm thick CRCA sheet suitable for mounting5 Nos MCB 6 to 32 Amp & 01No of TPN MCB with IP 43 protection, Glazed door with fixing four energy meter and provn of bus bar of capacity 150 Amp with locking arrangement of size not less than 75cmX75cmx15cm. (Taking down of old Unserviceable TPN or meter box and civil work i.e plaster work and repainting of surfaces as in previous is included in the quoated in the item rate). |
| 110 | Supply and fix in repairs MCB SPN DB 8 waydouble door,IP 43 protection, Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09 complete all as specified and directed. |
| 111 | Supply and fix MCB TPN 63 Amps \"C\" series 10 Ka, 240 volts including taking down old U/S MCB completeall as specified and directed. |
| 112 | Supply and fix MCB SPN 40 Amps,10 Ka, 240 voltscompleteall as specified and directed. |
| 113 | Supply and fix MCB SP 6 to 32 Amps, 10 Ka, 240 volts including taking down old completeall as specified and directed. |
| 114 | Supply and fixing Bulb holder angular PVC/Polycarbonate suitable for batten fittingscomplete all as directed. |
| 115 | Supply and fixing LEDBatten fitting 1x18watts including tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting complete all as specified and directed. |
| 116 | S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 117 | Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil including taking down out old earthing material complete all as shown on Electrical plate No 3 of MES SSR-I complete all as specified and directed. |
| 118 | Supply and repair/replacment of sub main wiring with two runs of single core, FRLSH 6 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn through and including PVC casing caping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and one run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 4 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring along with damaged casing caping from wall or roof or floor and making good disturbed surfaces complete all as specified and directed.Note : Two run of 6 Sqmm cable, one run of casing caping and one run of 4 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run. |
| 119 | Supply only LED bulb fitting decoratvie type including fitting and fixture of 6 Watt (Warm white) complete all as specified and as directed. |
| 120 | Supply and fixing of LED building security light fittings in aluminium PDC housing, toughened glass cover, individual LEDs with secondary optics, covered with IP66 protection with inbuilt surge protection of minimum 5KV and of capacity 35/36 W including GI bracket of 40mm pipe all as specified and directed. |
| 121 | S&F Geyser 25 ltrs capacity5 Star rated single phase 230 volts 50 Hz ,2 KW including required number of bolts, nut, grouting/plastering arrangement to fix the geyser properly & safely on wall, Make:- Usha / Havells/ Bajaj / crompton or equivalent make specified in CA.(i) The cost of Necessary grouting/nuts, bolts, PCC, Making good etc. shall be included in quoted rate without claiming any extra cost. |
| 122 | M&L for cutting of circular hole in any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified |
| 123 | Supply and fix exhaust fan, metallic body AC single phase, 230V of size 300mm sweep with, blades, frame and louvers complete all as specified and directed by Engr-in-charge. |
| 124 | Supply & fixing in repair ofceiling fan 1200 mm (minimum) sweep, BEE 5 star rated with BLDC technology, AC single phase 230 volt, without remote Suspended from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling rose/fan complete all as specified and directed. Make:- Usha Model- ENERGIA 32, Havells Model- EFFICIENCIA NEO or equivalent in Orient/Bajaj. Note:- Old unserviceable ceiling fans shall be deposited to MES store. |
| 125 | Supply and repair/replacment ofSub main wiring with two runs of single core, FRLSH 1.5 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 1.5 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 1.5 Sqmm cable one run of conduit and one run of 1.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.Note : Two run of 1.5 Sqmm cable, one run of casing caping and one run of 1.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run. |
| 126 | S&F Calling bell, Ding Dong, AC 230 volts, single pole, complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy