| 1 | Taking down chowkats or frames exceeding 1.50 sqm but not exceeding 4.00 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed |
| 2 | Taking down chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 3 | S&F Pressed steel frames for doors of frame size 125x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 4 | S&F Pressed steel frames for doors of frame size 105x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed.Note : Filling of hollow portion of frames with PCC shall be measured and paid separately. |
| 5 | Material & Labour for PCC 1:2:4 type B0 (Using 12.5mm graded stone aggregate) as in filling of pressed steel frame, complete all as specified and as directed. |
| 6 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and directed. |
| 7 | S&F second class hard wood 35mm glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars),edges of framing plain, chamfered or roundedfitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a) and fitted to chowkhats complete all as specified and directed. |
| 8 | S&F 35 mm thick factory made second class hard wood plain framed panelled shutter (Two panel) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm veneeredparticle board with commercial veneering on both faces. The size of rails and style as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 9 | Supply and fix Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2 mm thick Moulded PrelamPVC sheet on the front face & 2mm plain colour PVC sheet on back face, andfixing in frame at site as per specification and drawings complete all as specified and directed. |
| 10 | Supply and fix aluminium anodised (powder coated) ventilator frame (section for frame63.5 X 38.1X 1.40mm thick) with shutter(section for shutter 41 x 20 x1.5mm thick)(bottom half portion fixed and top half portion with louverincluding all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia and average width of aperture 1.40 mm outside vent with staple and suitable wall angle of size 25.4 x 25.40 x 1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc. complete all as specified and as directed.Note: The quoted rate by the contractor shall be inclusive of taking down ventilators of any size and any description and making good to match the existing surfaces. |
| 11 | Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with (2 Nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick plain glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc with the following section of frame and shutter complete all as specified and directed:-(a) Sections for shutter:- (i) \"H\" section: 39 x 20 x 1.20 mm thick (ii) \"Interlock\" section: 39 x 20 x 1.20 mm thick(iii) \"Edge & Bottom\" section: 41 x 20 x 1.20 mm thick (b) Section for frame:-(i) Top & Sides: 92 X 29.50X 1.20mm thick(ii) Bottom: 92 X 29.70 X 1.20mm thick |
| 12 | M&L for preparation of new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 13 | M&L for preparation of newsteel surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primeron steel surfaces complete all as specified and directed . |
| 14 | Supply and fixedstainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or stainless steel wire staples including all cuttings, wastage etc. complete all as specified and directed. |
| 15 | S&F 150 mm long extruded aluminium alloy handles, fabricated type, anodizedcomplete all as specified and directed. |
| 16 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 17 | S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as specified and directed. |
| 18 | S&F 100 mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 19 | S & F mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 20 | Supply and fixing of helical door spring of size 300 mm long including roller plate complete all as specified and as directed |
| 21 | S & F in repairs20mm dia tubular curtain rod, brass chromium plated complete all as specified and directed. |
| 22 | S&F in repair brass chromium plated brackets for curtain rod of any size complete all as specified and directed. |
| 23 | Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) of walls, chajja, fins, facia etc. any height mixed with water proofing compound (for 5mm thick finishing layer only) @ 3 % of weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement including taking down old existing plaster complete all as specified and directed.Note: (i) Water proofing compound will be measured and paid separately(ii) Cost of scafolding, any height are deemed to be inclusive in the quoted rate. |
| 24 | Supply only Integral waterproofing compound |
| 25 | Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqmm over newsurfaces complete all as specified and directed. |
| 26 | Material and labour for 10 mm thick rendering in cement mortar (1:6) onfair faces of brick work or concrete surfaces,finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over wall care putty, minimum 1.0 mm thick and a coat of alkali resistant primer complete all as specified and directed. |
| 28 | Washing, rubbing down and stopping of distempered surfaces on any type of wall including preperation of old surfaces and applying two coats of oil bound distemper of any tint with 1mm wall care putty where ever required complete all as specified and directed by Engineer -in-Charge.Note: Wall care putty shall be measured and paid separately. |
| 29 | Washing, rubbing down and stopping of distempered surfaces on any type of ceiling including preperation of old surfaces and applying two coats of oil bound distemper of any tint with 1mm wall care putty where ever required on ceiling surfaces complete all as specified and directed.Note: Wall care putty shall be measured and paid separately. |
| 30 | M&L for applying 1mm thick wall care putty on internal wall complete all as specified and directed. |
| 31 | M&L for applying 1mm thick wall care putty on internal ceiling complete all as specified and directed. |
| 32 | M&L for preparation of old plastered surfaces and applying two coats of white wash on ceiling surfaces complete all as specified and directed. |
| 33 | M&L for preparation of old plastered surfaces of walls and applying one coat of white wash on wall surfaces complete all as specified and directed. |
| 34 | Material & Labour for preparation of old painted surface of wall and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives complete all as specified and as directed. |
| 35 | S&F Hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing on and including GI frame as per specifications including taking down existing wall panelling and similar work complete all as specified and directed. |
| 36 | Dismantling wall and ceiling boards (fibre,pulp, insulation etc.) or insulation boards / slabs/ blankets, any thickness, including fillets complete all as specified and as directed. |
| 37 | M&L for anodised aluminium snap grid frame work for false ceilingof size 600mm x 600mm including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified. |
| 38 | S&F decorative PVC ceiling board of superior quality of size 600mm x 600mm x 5mm thick fixed in aluminium snap grid frame work including fixing accessoriescomplete all as specified and as directed.Note: (I) Frame work shall be measured and paid separately under respective item. (II) Colour and design PVC ceiling board shall be approved by GE. |
| 39 | Dismantling AC/CGI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and make good for aluminium earthing strips after fixing of sheets complete all as specified and directed. |
| 40 | Fixing only plain or corrugated galvalume aluminium zinc coating PPGL based corrugated/Trapezoidalsteel sheet 0.50mm thick as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.Note: Serviceable sheet as obtained from dismantling item here-in-before. |
| 41 | S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed . |
| 42 | S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed . |
| 43 | Material and labour for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering (backing coat) in CM 1:4including demolition of existingtiles and cement mortar bedding (but not backing) and removing from site and rubbish of the premisses complete all as specified and directed. |
| 44 | Material and labour for coloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor over and including 15mm thick screed bed/bedding layer in cement mortar 1:6 including demolition of existing floor tiles and bedding layers and removing from site and rubbish of the premisses complete all as specified and directed. |
| 45 | M & L for vitrified ceramic tiles 8 to 10mm thick light shade(square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm as in floor, etc. set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor laid over and including 15mm thick screed bed/bedding layer in cement mortar 1:6 including demolition of existing floor tiles and bedding layers and removing from site and rubbish of the premisses complete all as specified and directed. |
| 46 | M&L for machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick cement screed base in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including demoltion of kota stone slab and removing from site and rubbish of the premisses complete all as specified and directed. |
| 47 | M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick backing coat in cement mortar (1:3) including demolition of existingkota stone slab and cement mortar bedding (but not backing) and removing from site and rubbish of the premisses complete all as specified and directed. |
| 48 | Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc and applying roof treatment with the following steps and specifications:- a) Applying cement slurry over concrete surfaces @3kg/sqm. b) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement or @ 200ml per 50 Kg of cement or as per manufacturer\"s instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof (levelling course).c) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @0.25 litres per sqm conforming to IS : 3384-1986.d)Applying evenly one coat of blown hot bitumen of grade 85/25@ 1.20Kg square metre on primed surfaces.e) A layer of APP based polymeric membrane, 3mm thick(minimum), weighing 3.5 kg/m2 reinforced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. f) Applying evenly one coat of aluminium paint @ 0.10litre per square metre over the APP based polymeric membrane. |
| 49 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level) and removing debries from site of work complete all as directed by the Engineer-in-Charge. |
| 50 | M & L for 75 mm thick cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in sub base of floor complete all as specified and directed. |
| 51 | M &L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 52 | M & L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed. |
| 53 | M&L for cement concrete 1:2:4 Type B-I (using 20mm graded stone aggregate) as in edging of path (interlocking paver) and the like including weathering slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces complete all as specified and directed. |
| 54 | S&F in repairs 15mm dia bib tap standard of PTMT any colour high pressure screwed for iron pipe (minimum weight - 90gms) and fixed complete all as specified and as directed. |
| 55 | M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good disturbed area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap complete all as specified and directed. |
| 56 | Supply & fixing in repairs vitreous chinaurinal half stall type size (465x355x265) white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including60mm long brass screws pointing around urinal back in cement; fixing flushing cistern with brackets, grating and union including waste pipe and PVC connection pipe of 15 mm size with PTMT nuts of length 600mm, etc complete all as specified and directed. |
| 57 | S&F in repair wash hand basin, white flat back of size 550 x 400mm excluding pillar taps but including waste coupling, waste pipe and bracket, PVC connection pipe of 15 mm size with PTMT nuts of length 600mm, etc.including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 58 | Taking up or down steel tubing 15mm boreand connections including cleaning for refixing or removal to store and S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 59 | Taking up or down steel tubing 20 mm boreand connections including cleaning for refixing or removal to store and S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 60 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 20 cm girth in brick walls etc complete all as specified and directed. |
| 61 | M&L for treatment to sunken floor of Toilet/Bathroom as in following steps:-i)Top of RCC slab in sunken portion includingperipheral beams shall be plastered with 15mmthick in cement mortar 1:3 using approved waterproofing compound @ 3% by weight of cement finished even and smooth using extra cement,curved at the junctions. ii)Apply two coats of epoxy resin/polymer modified cementatious coating like brush bond of FOSROK/SIKA/Pedilite both on floor & beams.iii)Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyondouter surface of wall shall be provided.iv)Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE. |
| 62 | M&L 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stoneaggregate) as in topping of floor to receive floor tiles complete all as specified and as directed. |
| 63 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushedstone aggregate) as in filling to sunken floor complete all as specified and directed. |
| 64 | S&F in repair 10 litres capacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern including PVC connection pipe of size 15 mm dia, 450 mm long with PTMT nuts complete all as specified and directed. |
| 65 | Supply and fixed in repairs vitreous china squatting pan, Orissa pattern of size 580 mm x 440mm white withP or S trap, front or back inlet and integral foot rest (Excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 66 | S&F in repairs 15 mm dia pillar tap, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 67 | Taking down eaves gutters, sewage lines andrainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swannecks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 68 | M & L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and directed. |
| 69 | M & L for 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and directed. |
| 70 | S & F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 71 | S & F 75 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 72 | S & F 110mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door including necessary scafoldingupto any height complete all as specified and directed. |
| 73 | S & F 75mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door including necessary scafoldingupto any height complete all as specified and directed. |
| 74 | Supply & fixing sheet glass ordinary quality 4mm thick glazing in square/ rectangle not exc 0.50 sqm each pane with oil putty or aluminium beads fixed to steel/aluminium frame, etc. including scaffolding upto 14 m completeall as specified and as directed. |
| 75 | Supply & fixing sheet glass ordinary quality 4mm thick glazing in square/ rectangle exc 0.50 sqm each pane with oil putty or aluminium beads fixed to steel/aluminium frame, etc. including scaffolding upto 14 m completeall as specified and as directed. |
| 76 | M&L forrepair and rendering 10mm thickin CM 1 :3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of visible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm gradedstone aggregateincluding necessary scaffolding work for double/single storey bldgs complete all as specified and directed. |
| 77 | M&L for 75 mm thick cement concrete type C2 1:3:6using 20 mm graded stone aggregate as in plinth protection finished fair and even with using extra cementcomplete all as specified and directed. |
| 78 | M&L for cement concrete type C2 1:3:6 using 40 mm graded stone aggregate in surface channels and drains complete all as specified and as directed. |
| 79 | Supply & Fix half round colour coated UPVC gutter/runner drop for rain water drain in buildings of size not exceeding 150 mm dia with firmly attached down spout of suitable size discharging storm water into PVC SWR pipe of 110 mm dia and similar works etc complete allas specified and directed. Note: The quoted rate shall be deemed to be inclusive of down spouts, drop outlet, elbow, end cap, straight connecter, brackets, down spout couple, splash block, out site corner, clamps as required at site as per standard engineering practice. |