| 1 | Demolition of reinforced cement concrete, (reinforcement cut as required to facilitate demolition) (RCC water tank) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 2 | Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified anddirected. |
| 3 | Removal of vegetation/grass etc including cutting holes into or through brick walls/concrete and removal of small trees/woods etc and making good disturbed surfaces with PCC (1:2:4), type B-0 (using 12.5mm graded crushed stone aggregate) surface area n. exc. 0.50 Sqm, complete all as specified and directed. |
| 4 | Cleaning/uprooting of vegetation/small trees, muds, garbages, waste etc growth on inaccessible RCC roof, AC sheet roof, below wind tie, cleaning of AC sheet/CGI sheet, valley gutter and shaft portion of wall surfaces, back side of toilet portion, complete all as specified and directed. |
| 5 | M & L for brick work withsub class \"B\" bricks, old size bricks, burnt clay, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4), complete all as specified and directed. |
| 6 | Taking out old damaged tarfelt or membran of any description including screed bed or bedding layer and removing of debris to a distance exc. 50m and n. exc.100mand cleaning roof surfaces to remove all loose dust etc, roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water using wire brush, brooming down and applying the following treatment all as directed in order of precedence as stated:(a) Brushing neat cement slury with 3.50 kg of cement per Sqm.(b) 15mm thick screed bed or bedding layer in CM (1:4) mixed with water proofing compoundas per manufacturer instruction on existing roof surface true to level.(c) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (d) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.50 Kgs per Sqm reinforced with non-woven polyester fabric weighing not less than 160gms per Sqm having softening point not less than 15°C, having tensile strength of 650 N/Sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N by torch application. Polymeric membrane shall be taken to a height of 30cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (e) Applying one coat of aluminium paint @ 0.11 Kg/Sgm over APP membrane surface. Note:- (i) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions.(ii) A minimum overlap of 150mm and 100mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.(iii) APP based polymeric membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/1S 16532 2017.(iv) Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. (v) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work.(vi) The work shall be executed through authorised applicators of original manufacturer only.(viI) WPC shall be measured and paid separately as supply only. |
| 7 | Disconnecting existing tanks exc. 500 ltr but not exc. 1000 ltr, set aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed. (Note : Cleaning repairing, etc. shall be measured and paid separately) |
| 8 | Disconnecting existing tanks exc. 250 ltr but not exc. 500 ltr, set aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed. (Note : Cleaning, repairing, etc. shall be measured and paid separately) |
| 9 | S&F rotational moulded polyethylene water storage tanks, (made 100% virgin and food grade plastic), triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1996, hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old unserviceable water tank of any capacity, complete all as specified and directed. |
| 10 | S&F rotational moulded polyethylene water storage tanks, (made 100% virgin and food grade plastic), triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1996, hoisted and fixed in position all as specified in SSR Part I (500 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old unserviceable water tank of any capacity, complete all as specified and directed. |
| 11 | S&Fin repair 20mm boreball valves high pressure of PTMT withepoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass and fixed, complete all as specified and directed. |
| 12 | S&Fin repair tank cover suitable for any type of rotational moulded polyethylene water storage tanks, complete all as specified and directed. |
| 13 | S&F in repair 20mm bore gun metal gate valve with iron wheel screwed both ends for iron pipes, complete all as specified and directed. |
| 14 | Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 15 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 16 | Supply, laying & connecting of 15mm bore GI tubing, medium grade, with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs,fixed to wall and ceiling or laid in floors, complete all as specified and directed. |
| 17 | Supply, laying & connecting of 20mm bore GI tubing, medium grade, with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs,fixed to wall and ceiling or laid in floors, complete all as specified and directed. |
| 18 | Re-fixing old steel tubing and connection, 20mm bore, in new or old position with new fittings, complete on wall/ceiling, complete all as specified and directed.(Note : Serviceable steel tube obtained from taking down shall be re-used) |
| 19 | M&L for 4mm thick pre-painted E-fibre board, designer/decorative, fixed or laid/inserted to and including GI snap grid frame size 605x 605mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required), adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long, including dismantaling of existing unserviceable ceiling boards of any thickness including cover fillets, complete all as specified and directed. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site of work, complete all as specified and directed. |
| 21 | S&F MS framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 22 | M&L for preparation of newsteel or iron surfaces of any description over 10cm width or girth not otherwise specifically provided for and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed. |
| 23 | Demolition of plain cement concrete (unreinfoced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level), complete all as specified and directed. |
| 24 | M&L for 75mm thick PCC (1:2:4)type B-2 (using 40mm graded crushedaggregate) as in plinth protection/apron laid in alternate bays (n. exc. 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic fillar comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and directed. |
| 25 | M&L for post construction antitermite treatment by providing and injecting chemical emulsion (ATT chemical) along with external wall below concrete or machinery apron/floor using chemical emulsion @ 2.25 ltr/RM including drilling and plugging holes etc, complete all as specified and directed. |
| 26 | M&L for post construction antitermite treatment of soil under existing floor using chemical emulsion (ATT chemical) @ 1.00 ltr/hole, 300mm dia apart including drilling and plugging 12mm dia holes with CM (1:2) to match the existing floor, complete all as specified and directed. |
| 27 | M&L forpost construction antitermite treatment at point of contact of wood work by using chemical emulsion (ATT chemical) (in oil or kerosene bases solution) @ 0.50ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed. |
| 28 | M&L for PCC (1:2:4) type B-1(using 20mm graded crushed stone aggregagte) as in surface channels and drains, complete all as specified and directed. |
| 29 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using ex- tra cement including forms, moulds, mi- tred/stopped ends et, complete all as specified and directed. |
| 30 | Taking down cement plaster on brickor concrete surfaces including racking out joints, hacking for key, scrubbing downwith water etc, complete all as specified and directed.. |
| 31 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with water proofing compound on top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately) |
| 32 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. |
| 33 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and directed. |
| 34 | M & L for preparation of newly plastered surfaces of walls and applying two coats of 100% acrylic weather proof exterior emulsion paint of approved colour and shade over a coat of exterior emulsion primer, alkali & fungal resisatance, complete all as specified and directed. |
| 35 | M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed. |
| 36 | M&L for preparation of newly plastered surfaces on wall and applying three coats of white wash, complete all as specified and directed. |
| 37 | M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening primer, complete all as specified and directed. |
| 38 | Cleaning the surfaces of brick/RCC using wire brush , brooming down and washing down with water to remove dust etc. and brushing with neat cement slurry @0.5 kg/sqm with acrylic based polymer modified cementitous composite (as approved by Engr-in-charge) @ 0.50 kg/sqm, complete all as specified and directed. |
| 39 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings, complete all as specified and directed. |
| 40 | S&F pre painted galvalume aluminium zinc coating, GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws, complete all as specified and directed. |
| 41 | S&F pre painted galvalume aluminium zinc coating, GI based plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws, complete all as specified and directed. |
| 42 | S & F 1.00mm thickplain, galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and eaves/straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and as directed. |
| 43 | M&L for preparing old steel surfaces of CGI roof sheet of any description over 10cm width or grith and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc primer, complete all as specified and directed. |
| 44 | M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including concealed, rigid PVC conduit (ISI marked) not less than 20mm dia, heavy duty, including all conduit accessories with and including concealed pressed steel terminal box of suitable size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole including taking down old unserviceable point wiring of any type, size/description and from any position, complete all as specified and directed. |
| 45 | All as per item No 44.00 here-in before but for 3 pin 5 Amp socket point on same board, complete all as specified and directed. |
| 46 | All as per item No 44.00 here-in before but for 3 pin 5 Amp socket point on independent board, complete all as specified and directed. |
| 47 | All as per item No 44.00 here-in before but with 4.0 Sqmm PVC insulated unsheathed multi stranded cable FRLSH type for one 15 Amp 3 pin socket outlet point including PVC insulated 4.0 Sqmm FRLSHtype copper multi stranded conductor as earth wire, complete all as specified and directed. |
| 48 | All as per ser item No. 44.00 here-in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed. |
| 49 | Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduitheavy duty and accessories of not less than 25mm dia ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 6.0 sqmm single core PVC insulated unsheathed copper earth continuity, including cutting chases and making good disturbed surface as per existing surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed.Note: (i)Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length. |
| 50 | Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduitheavy duty and accessories of not less than 25mm dia ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 4.0 sqmm single core PVC insulated unsheathed copper earth continuity, including cutting chases and making good disturbed surface as per existing surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed.Note: (i)Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length. |
| 51 | M&L for point wiring with multistranded copper conductor cable,PVC insulated and unsheathed (FRLSH) size 1.5 sqmm drawn in and includingPVC casing and caping (ISI marked) with fixing accessories, to befixed on wooden gutties or plastic rawal plug, for one light /fan point controlled by one switchwith pressed steel concealed terminal boxes coveredwith 3mm thick laminated sheet / modular plate incl continous earth wire of PVC insulated unsheathed, (FRLSH) multi stranded copper conductor cable of size 1.5 Sqmm for earth wire connected to common earth dolly for one light/fanpoint/bell point controlled by one, one way switch single pole including taking down old unserviceable point wiring, complete all as specified and directed. |
| 52 | All as per item No 51.00 here-in before but one 3 pin 5 Amps socket outlet on the independent board controlled by other swtich, complete all as specified and directed. |
| 53 | All as per item No 51.00 here-in before but one 3 pin 5 Ampssocket outlet on same board controlled by other switch, complete all as specified and directed. |
| 54 | All as per ser item No. 51.00 here in above but for one 16 Amp 3/5 pin switch socket outlet independent point including PVC cable 4 Sqmm FRLSH type multistranded copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed multistranded copper conductor cable FRLSH type for as earth wire, complete all as specified and directed. |
| 55 | S&F in repair switch piano flush button single pole, one way 6 amps 240 volts, complete all as specified and directed. |
| 56 | S&F in repair bell push, flush type, 6 Amps, complete all as specified and directed. |
| 57 | S&F in repair socket outlet 2 in 1, 3 pin 6 Amp, flush type, complete all as specified and directed. |
| 58 | S&F in repair switch and socket combination2 in 1, 5 pin 6 Amp,flush type, complete all as specified and directed. |
| 59 | S&F in repair switch and socket combination 3 pin, 16 Amp, flush type, complete all as specified and directed. |
| 60 | S&F in repair fan regulator, deluxe rotary step type, complete all as specified and directed. |
| 61 | S & F in repair angle lamp holder, PVC/polycarbonate type, complete all as specified and directed. |
| 62 | S&F in repair bell electric, heavy duty, ding dong type, 240 volt, single pole, complete all as specified and directed. |
| 63 | S&F in repair ceiling rose, surface bakelite PVC/ polycarbonate, isolated body with 2/3 terminals, complete all as specified and directed. |
| 64 | M&L for sub main wiring with two run of 6 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable (FRLSH) 1100 Volt grade, drawn through and including PVC casing caping (ISI marked) including all accessories and one run of6 Sqmm single core PVC insulated unsheathed (FRLSH) copper earth continuity conductor including taking down old unserviceable sub main wiring, complete all as specified and directed.(Note : Two runs of6 Sqmm single core cable with one run of earth continuity conductor including PVC casing caping and its accessories shall be measured and paid as one length). |
| 65 | M&L for sub main wiring with two run of 4 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable (FRLSH) 1100 Volt grade, drawn through and including PVC casing caping (ISI marked) including all accessories and one run of4 Sqmm single core PVC insulated unsheathed (FRLSH) copper earth continuity conductor including taking down old unserviceable sub main wiring, complete all as specified and directed.(Note : Two runs of4 Sqmm single core cable with one run of earth continuity conductor including PVC casing caping and its accessories shall be measured and paid as one length). |
| 66 | S & F energy efficient 300mm PVC air ventilating fan, high speed, complete with louvers and connecting wire up to nearest ceiling rose including taking down old unserviceable fan of any sweep, complete all as specified and as directed. |
| 67 | S & F in repair 4mm dia GI wire earth continuity conductor or main earthing lead, ixed to wall on batten or recess or chase or buried in ground or drawn in conduit/pipe or fixed to pole or other indicated situation for loop earthing etc, complete all as specified and directed |
| 68 | S&F in repair rigid non-metallic PVC conduit, medium grade, external dia 20mm exclusive of boxes (junction/terminal) but inclusiveof all tees, bends, elbows, reducers, bellmouth tube ends andfixing accessories such as couplers, lock nuts, saddles, pipe hoos etc, complete all as specified and directed. |
| 69 | M & L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized strip of size 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-I with 50mm thick Pre-cast RCC (1:2:4) type B-I cover slab (reinforced with 8mm dia deformed bar @ 15cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 40mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including taking down old unserviceable earthing of any description, complete all as specified and directed.Note : Proper earthing pit shall be provided with pit cover. |
| 70 | Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity upto 25/50 ltrs comprising of the following works, complete all as specified and as directed :-(a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge.(b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required.(c) Inspect overflaw and vent pipes and remove blockages (if any).(d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points.(e) Check, maintain and re-fixing thermostat and re-adjust.(f) Visual examination of of fusible plugs for its serviceability.(g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution.(h) Checking of indicator lamp for its serviceability.(j) Re-assembling the geyser, re-installed and testing.Note: (i) Spare parts/components of geysers shall be measured and paid seperately as \"supply only\" under respective items. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.) |
| 71 | Supply only heating elements as per site requirement of capacity 1.5 KW, 230 volts ISI marked, complete all as specified and as directed. |
| 72 | Supply only heating elements as per site requirement of capacity 2 KW, 230 volts ISI marked, complete all as specified and as directed |
| 73 | Supply only aperature plate suitable for 25 Ltr capacity, complete all as specified and as directed |
| 74 | Supply only high pressure safety valve, complete all as specified and as directed |
| 75 | Supply only geyser NRV (Non Return Valve) 1/2 inch 0.8 MPa pressure, complete all as specified and as directed |
| 76 | Supply only hot and cold \"304 grade stainless steel re- enforced flexible connection pipe\" 450mm long, ISI marked, complete all as specified and as directed |
| 77 | Supply only thermostate adjustable type 11/20 Amp 240 Volts, ISI Marked, complete all as specified and as directed |
| 78 | Supply only thermostate adjustable type 7/15 Amp 240 Volts, ISI Marked, complete all as specified and as directed |
| 79 | S&F in repair for bib tap cast alloy screwed down with crutches or butterfly handle, screw down for iron pipe of for brass ferrule of size 15mm for GI tubing, complete all as specified and directed |
| 80 | Note: An amount of Rs.53,843.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 81 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |