Additional 5 Mva Installation At 33/11 Kv S/S Rajnikhand And Other Associated Work. - Dragging, Loading, Carriage And Unloading Of Following Store Materials With Proper Stacking From Esc Daliganj To Je Dumps Store And From Je Dump Store To Work Site Withi, Lucknow-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Additional 5 Mva Installation At 33/11 Kv S/S Rajnikhand And Other Associated Work. - Dragging, Loading, Carriage And Unloading Of Following Store Materials With Proper Stacking From Esc Daliganj To Je Dumps Store And From Je Dump Store To Work Site Withi. Submission Date for this Tender is 10-09-2025. Transformer Supply Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50987138
Additional 5 Mva Installation At 33/11 Kv S/S Rajnikhand And Other Associated Work. - Dragging, Loading, Carriage And Unloading Of Following Store Materials With Proper Stacking From Esc Daliganj To Je Dumps Store And From Je Dump Store To Work Site Withi
Tender
Indian
Uttar Pradesh
Lucknow
10-09-2025

Tender Details

Additional 5 MVA Installation at 33/11 KV S/S Rajnikhand and other associated work. - Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. 2 33 KV VCB 800 Amp. 750 MVA 3 33 KV Control Pannel single circuit Transformer 4 33KVCurrent Transformer 200/100/1 5 11 KV Incoming VCB 600/300/5A, 350 MVA 6 11 KV Out going VCB 200/100/5A, 350 MVA 7 11 KV VCB Bus coupler, 350 MVA 8 11 KV 3x300mm2 XLPE Cable 9 11 KV3x300mm2Outdoor Termination Kit 10 11 KV3x300mm2Indoor Termination Kit 11 11 KV3x185mm2 XLPE Cable 12 11 KV3x185mm2Outdoor Termination Kit 13 11 KV3x185mm2Indoor Termination Kit 14 33 KV 3x300sqmm XLPE cable 15 33 KV Jointing Kit Outdoor 3X300sqmm XLPE Cable. 16 33 KV Lightening Arrester 17 33 KVBus Isolator 18 Battery charger 24 Volt 19 Battery set12 Nos. x2 Volts ,200Ah 20 ACSR Panther Conductor for Bus Bar 21 ST pole 11 mtr long 22 M.S.Angle 65x65x6 sq mm 23 Polymeric 11KV Pin Insulator 24 M S Earthing Rod 240x20 mm 25 11 kv pin with nut 26 1x240 LT XLPE Cable 27 MS Channel 125x65mm 3.5m long 4 Nos Pieces 14M@13.1 Kg. Mtr. With wastage 28 MS Angle 75x75x6, 2.6M 2 Nos Total 5.2@6.8 Kg./M with wastage 29 MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr. 30 MS channel 100x50 mm 31 Rail 105 Lb 8 MTR. LONG 32 Earthing of substation Switchyard. 33 Supply of MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for laying of main earth matin extantred switchyard &pannel earthing Bridge 160 ckt. Mtr. 34 Supply of MS Round Bar 32 mm dia (6.21 Kg. per mtr.) for making M.S. Earth electrod 32x3000 mm (14no.x3.0mtr.) 35 Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete (10mtr.x15mtr.) as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all material ) 36 Cutting ,fabrication and driving of earth electrode of size 32x3000 mm 37 Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor ) 38 Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms. 39 Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel). 40 Painting of all structures equipment Newly Constructed only 41 Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 Mas 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8using M.S bar of 12 mm dia for reinforcementthe work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department) 42 Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB. 43 Fabrication & erection of 11 KV cable exposure type double pole with the provission ofcable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms. 44 Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt) 45 Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structureas per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. 46 Erection of structures, grouting, plinthing of ALL structuresequipment. 47 Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment . 48 33 KV VCB 49 CT 200/100/1-A 50 33 KV lightning Arrestors 51 Bus/Line Isolator 52 Fabrication & Erection of Neutral Stand structure with foundation 53 Commissioning and Testing of5 MVA T/F & Control cable laying & Termisnation by using cable gland & Lugs 54 Jumpering complete T/F bay with ACSR panther Cond. and required L clamp with nut & Bolts from 33 KV existing bus bar & 33 KV cable to T/F (with copper L piece)other all required work. ( Except Panther Conductor all required material provided by Contractor.) 55 Laying ofDouble circuit 11 KV 3x300 sq mm XLPE cable in normal soil/allready Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench. 56 Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panelwith proper taping with the help of empire tape. PVC tape and connectors. 57 Hoisting of 11KV3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6 dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor). 58 Laying of Single circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench. 59 Hoisting, jumpering, clamping of 11KV 3x185 sq mm XLPE cable on 11 KV panelswith proper taping with the help of empire tape. PVC tape and connectors. 60 Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench. 61 Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle as per RESPO Norms 62 Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system as per Site Condition with cleaning of Existing Trench.( all the material shall be provided by contractor) as per norms 63 Copper Control Cable 2x2.5 Sq. mm. 64 Copper Control Cable 4x2.5 Sq. mm. 65 Pipe boring type earthing minimum 20 mtr deepfrom ground level or upto water level with B class G.I. pipe 2 dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor) 66 PG Clamp Panther to Panther 67 Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms 68 33 KV T/F Control panel 69 11 KVBus coupler, 350 MVA 70 11 KV Incoming VCB 600/300/5A 71 11 KV Out going VCB 200/100/5A 72 Grouting,Plinting and Painting of new erected 11M long ST poles of single pole support,double pole cableexposures and end type poles of 33 KV lines 73 DiggingofPitinkachcha/Pakkalandindepthupto1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 33 KV line on 11 M long ST Pole and 11 mtr. PCC Pole refilling with ramming of earth. 74 Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms. 75 Construction of pole plinth 300mm x 450 mm above ground levelin 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. 76 Painting of new erected ST pole with two coat of red oxide paint,POredpaintattopofpole2M &balancebytwo coatsof bestqualityaluminiumpaintISIof Burger/Nerolac/Asian mark as pernorms. 77 Supply of following auxiliary material 78 Rabber mat 2x1.5 Mtr. 79 Erection of 24 V batteries set with charger including stand (except 24 V batteries set with charger all the material & stand shall be provided by contractor) & initial charging complete set. 80 High Pressure Testing 81 Dismantlingof fencing & toe wall20 mtr.& Refixingof fencing & toe wall4 mtr 82 Shifting of Capacitor Bank with structure Isolator & Cable stand 83 Return balance material to LESA store daliganj and other work in site area

Key Value

Document Fees
INR 3540 /-
EMD
INR 11430.0 /-
Tender Value
INR 11.42 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail