}

Tender For Construction Of C.S.R. Phc Center At Distt- Chandauli - Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The , kanpur-Uttar Pradesh

Uttar Pradesh Small Industries Corporation Limited has published Tender For Construction Of C.S.R. Phc Center At Distt- Chandauli - Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The . Submission Date for this Tender is 13-09-2025. Building Work Tenders in kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50986990
Tender For Construction Of C.S.R. Phc Center At Distt- Chandauli - Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The
Tender
Indian
Uttar Pradesh
Kanpur
13-09-2025

Tender Details

Tender For Construction Of C.S.R. Phc Center At Distt- Chandauli - Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 2 Filling of carted earth in plinth including supply of necessary quantity of earth from a distance not exceeding 8km from the side of work and including watering dressing etc. required for proper completion of work.(lead up to 30m & lift 1.5m) 3 Providing & laying cement concrete in 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggreagate 40mm nominal size) including supply of all materials,labour and T & P etc. required for completion of work and curing complete including cost of form work in foundation and floors 4 Sand Filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8km from the side of work and including watering dressing etc. required for proper completion of work.(lead up to 30m & lift 1.5m) 5 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:2:4 (M-20) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. 6 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:2:4 (M-20) in slab excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. 7 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:2:4 (M-20) in beams excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item. 8 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin over all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage and over lapping and hookes required for completion of the work TMT Fe 500 9 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 10 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 11 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortarin super-structure includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall less than 12cms. (1:4 cement : coarse sand) 12 Mild steel & iron work of small size & section such as holding down bolts hold fast tie rods garting etc (when not included in & over all rates) brought to required form including supply of steel & its wastage including cost of bolts nuts if required for proper completion of the work includind fabrication of holes in door chowkhats and nosing (Angle iron door frame) 13 Supply & fixing of flush door commercial quality conforming of IS 2202 part 1 (1983) including fixing of wooden cleats & stoppers and including fixing & adjustment of hinges ,bolts,locls,handles springs,fitting with necessary screws to be supplied departmentally 14 Fixing Chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonary for holdfast embedding hold fast in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 ( 1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size) painting two coats of approvedwood preservative to sides of chowkhats and making good the damage to walls and floors as required complete including disposal of rubbish to the dumpingall complete as per direction of Engineer in charge. 15 (a) Door chaukhats 16 (b) Window chaukhats 17 (c) Ventilator chaukhats 18 15mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand) plinth plaster 19 15mm cement plaster on rough side of single or half brick wall with cement mortar of mix1:6 cement & Coarse sand 20 12mm thick plaster with cement mortar in proportion of 1:6 cement & Coarse sand 21 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 22 P & L Ceramic Glazed floor tiles of size 300 x 300mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS:15622 of approved make in colours such as White, Ivory,Grey,Fume Red Brown,laid on 20mm thick cement mortar 1:4 ( 1 cement :4 coarse sand), Jointing with grey cement slurry, @3.3Kg/sqm including pointing the joints with white cement and matching pigment etc complete. 23 Supply and fixing 6 mm (1/4)thick china white glazedtiles inflooringorin skirting or dado laid with1:3 cement and approved coarse sand mortar finished with whitecement slurry jointing and polishing complete includingsupplyof allmaterials, labour and tool sand plantsetc.required forproper completion of the work.(Dado/skirting) 24 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 25 Finishing walls with putty (1 mm thick) approved brand and manufacture and of required shade and undacorated wall surface to give even shade over including curing and cost of all material labour T & P etc required for proper completion of work. 26 Distempering two coat with oil bound distemper of approved brand & manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J & N ,Shalimar Asian paints after throughly brushing the surface free from mortar droppings and other foreign matter & also including preparing the surface even with plaster of approved synthetic material & sand paperd smooth including cost of all materials labour T & P etc complete required for proper completion of the work. 27 Painting two coat over priming coat (but including cost of priming coat) on woodsurfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 28 Providing & fixing stainless steel sliding door bolts ISI markeddyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 10mm 29 P/Fixingstainless steeltower bolts ISI marked dyed to required colour or shade with necessary screws etc. 250 mm x 10mm 30 Providing & fixing stainless steelhandleswith screwsand 150mm long.SI marked 31 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete 600x600xmm size tiles 32 Providing and laying water proofing treatment on roofs of slabs by applyingcement slurry mixed with water proofing cement compound consisting ofapplying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqmmixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paidfor separately. For the purpose of measurement the entire treated surface will be measured.dsr2021/22.6 33 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 34 P & L DPC 40mm thick with cement concrete consisting of 1:1.5:3 ( 1 cement :1.5 coarse sand: 3 approved 20mm graded stone grit) and including water proofing material as approved by the Engineer in charge in the proportion as specified by manufacturer. 35 Painting on DPC with two coats of air blown VG-10 grade @ 1.70kg/sqm approximate including cost of fuel if any 36 Cement concrete flooring 1:2:4 ( 1 cement :2 coarse sand: 4 graded stone of size 12.5mm nominal size)laid in one layer finished with floating coat of neat cement (25mm thick floor) for apron 37 Providing and fixing glass strips of 25mm wide and 2.8 to 3.7mm thick in joints of floor and skirting at the time of laying floors flush with floor level including labour,tools,plants etc. complete 38 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work 39 Antitermite in Foundation and Plithe with 5 Step as per SOR 40 External water supply and Sanitation 41 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 42 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Flat back wash basin size 630x 450 mm with a single 15 mm C.P. brass pillar tap. 43 Providing and Fixing Stainless Steel grating of approved quality and colour.125 mm diameter 44 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter 45 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 46 90 mm O.D. 47 110 mm O.D. 48 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 49 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 50 Size 75 mm 51 Size 110 mm 52 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735.Size 75/90 mm 53 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735.Size 110 mm 54 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.Size 75x75x75 mm 55 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735.Size 110x110x110 mm 56 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete 110mm 57 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 58 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 59 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 20mm dia nominal outer dia pipes 60 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes 61 Providing & fixing CP brass bib cock of approved quality conforming to IS 893115mm nominal bore 62 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore 63 Providing and fixing brass stop cock of approved quality. 20mm dia nominal bore 64 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) 20mm dia nominal bore 65 Supply and fixing of UPVC S.W.R. pipe type B confirming to IS 13592 includimg jointing the pipeswith rubber ring ,lubricant and UPVC SWR couplar confirming ti IS 14735. Also including excavation of trenches cutting iof walls and holes and repairing walls,floors anf refilling the trenches as before but excluding supply and cost of other fittings such as elbow,bend,tee and Y tee ncluding suplly of all material labour and T&P Required for proper completion of work 160mm diameter 66 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)around U P.V.C SWR pipe including bed concrete as per standard design160mm dia. 67 Providing and fixing square-mouth S.W. Gully trap class SP-I complete with C.I. grating brick masonary chamber with water tight C.I. cover with frame of 300x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: with common burnt clay F.P.S.(non modular) bricks of class desiganation M-150. 150x100 mm. size P type 68 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 450mm deep including CI cover with frame With FPS bricks of class designation 150 69 Septick Tank & Soak pit 70 Indian Marka Hand Pump 71 Electrical Work Internal And External 72 Wiring Point for light 1.5 Sqmm FR PVC insulated multistrand single core copper conductor cable in heavy gauge PVC conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit (Sch. 131-C & 187-A) 73 Wiring Point for fan/fresh air Fan (Light duty exhaust Fan) with 1.5 sqmm FR PVC conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit (Sch. Nos.. 133-C & 187-A) 74 Wiring Point for plug 1.5 sqmm FR PVC insulated multistrand single wire copper conductor cable but in PCV conduit with 1.5 sqmm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit (Sch. Nos.. 134-C & 187-C) 75 S/F of Power Plug with 15 amp/250 Vatt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mmx 100 mmx 50 mm size with pheNos.lic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washe Sch no 1139-A 76 W/P for call bell with 1 sqmm FRPVC Insulated multistand .complete. Sch 135-C 77 Supply and wiring of sub main with two Nos.. FR PVC insulated 1100 v. grade multistrand single core copper conductor cable in 20mm dia 78 a)2.5 sqmm (1304-C) 79 b)4.0 sqmm (216-C) 80 S/F of 6 amp to 32 amp MCB (10 KA) (Sch. Nos.. 1002) 81 S/F of surface/flush mountingSPN DB Box (Consumer Unit) with 40 amt DP insolater for incomming but without MCB, complete in all respect 82 b)8 way (sch. No. 1036-A) 83 S/F of 6 watt LED Down Light ..complate item 84 S/F of 12 watt LED bulb 85 S/F of LED Tube light with battern suitable for up to 1x22 watt LED tube light fitting including tube on surface complete in all respect …. Completed (Sch No. 1413) 86 S/F of Sheet steel enclosure surface/flush mounting fitted with 20 AMP 2 Pin .. Complete. Sch. No. 1031 87 S/F of 1.5 Tones Split AC with 4 kva stablizer make-LG, Voltas, Videocon 88 S/F and making connection of folloing FPMCBS complate in all respected 89 63 amp DPMCB sch no-1011 90 S/f of 400 mm wall fan …..completed(Make Khaitan, Polar, Bajaj etc.) 91 S/F of 300 mm Fresh air fan .. Complete Make Bajaj, Khaitan, Polar. 92 S/F of call bell of ISI marked MDFEG/Teak Ply Board... complete (Sch. No. 1101) 93 Wiring point for HP MV/SV lamp in PVC conduit 1.5 sqmm FRPVC multistrand copper conductor cable… complete (Sch. 136-C 94 S/F 30 to 40 Watt LED street light… complete. Sch. 1420 95 Supply and burying 600 mmx 600 mmx 6.0 mm GI plate vertically for earthing with its top atleast 3 mtr below ground level complete with 20mm dia GI pipe and funnel for watering and one earthing lead of two Nos.s. 8 to 10 SWG GI wire in 15mm dia GI pipe Sch NO. 702 96 S/F of Electronic fan dimmer, 300/400 w ISI marked… complete(Sch. No. 1203-B) 97 BOUNDARY WALL 98 Earth workinexacavationin trenches forfoundationsand for pipes cables etc. in ordinary soil(loan clay or sand) including liftupto1.5 m and dressing ofsidesandrammingofbottom sand disposal ofsurplusexcavated earth as directed by the Engineer i/c withina lead of 50m.(PWD-251) 99 Providing and layingin cement concrete 1:5:10 (1 cement :5 fine sand :10 graded stone aggregate 40 mm nominal size) andcuring complete,including cost ofform-work,in foundation and floors.(PWD281) 100 R.c.c. workwith cement approved coarse sandand2cm. (3/4) guageapprovedstoneballastin the proportion 1:2:4in lintels of doors and windows excludingsupply of reinforcement and its fixing and binding the same with 24 BWG binding wire andincludingnecessary centering and shuttering etc.and also including supplyof all materials,labour andtoolsand plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-20. (PWD-283) 101 As in item 90 but for thelighterbeams i.e. having spans upto 6 m.(PWD- 285) 102 As in item 3 abovebut inR.C.C.Raft foundation and footingwithapproved stoneballast. (Using1:2:4Mix concrete)(PWD- 287) 103 As in item 5 above but in R.C.C. columns in1:1.5:3having strength not less than M-200(PWD- 289) 104 Same as in itemno. 7 above but 1:6 in super-structureaboveplinth levelup to floor two level ( up to two storeys ) including necessarycutting and mouldingofbrickworkas required andalsoincludinghoney combed brick work in thickness of wall more than 12cms.(PWD- 309 ) 105 Same as in item no.7 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below.(PWD-307+309+310A+310) 106 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. (PWD- 504) 107 12 mm cement plasterinsingle coat on rough sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 coarse sand 108 Finishingwallswith water-proofing on cementpaint of approved make such as super snowcem,durrocem,robiacem,guttucem supercem qualityandof required shade overone andincludingonecoatwhite cementprimertogiveaneven shade after thoroughly brushing the surface to powdered materialsincluding curing and cost of all materials.(PWD-660+661) 109 Supply andfixingM.S. Grill (PWD-502) 110 Painting Ist coat over priming coat (but excluding cost of priming coat) on steel andothermetalsurfacesup to 10 cm. widthorgirthorsmall articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolitesuperlac,DULUX specified brushingtogiveanevenshadeand including cleaningthe surfaceofall dirt,dust and other foreignmatter sand paperingand stopingincluding cost of all materials, labour toolsandplants etc. required forpropercompletion of the work. (Pwd 641+642) 111 Earth workinexacavationin trenches forfoundationsand for pipes cablesetc. in ordinary soil(loan clay or sand) including liftupto1.5 m and dressing ofsidesandrammingofbottom sand disposal ofsurplusexcavated earth as directed by the Engineer i/c withina lead of 50m.(PWD-251) 112 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.16.79dsr 113 Providing and laying of Rubber Moulded Interlocking Concrete Block Pavements having thickness 80 mm including leveling and dressing of surface to required level and slope, spreading and moisting 30cm thick local sand on bend,filling joints with local sand etc. for proper completion of work as per drawing and technical specification. 114 M-150 brick work in 1:4 cement and coarse sand mortar in foudation and plint including suplly of all material, labour and T&P 115 Add For Electrical External Service Connection

Key Value

Document Fees
INR 1180 /-
Tender Value
INR 18.96 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail