|
| 1 | Dismantling of brick work or stone/ boulder masonry built in cement or cement lime mortar, including all quoins, arches, pillars, etc. as per the directives of EIC. |
| 2 | Demolition of brick work or stone/ boulder masonry built in cement or cement lime mortar, including all quoins, arches, pillars, etc. as per the directives of EIC. |
| 3 | Removing cement or cement lime mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish |
| 4 | Demolition ofConcrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 5 | Demolition ofCement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for. |
| 6 | Demolition of Reinfiorced Cement Concrete (Reinforcement cut as required to facilitate demolition)) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work. |
| 7 | Dismantling of concentrina coil along with maximum 16 nos. RBT from the angle frame,removal to store and re-fixing in same location after completion of work and after necessary strainghtening, any repair as per the directives of EIC. |
| 8 | Dismanling of Angle frame any type embedded in cement concrete, removal to store and re-fixing in same location after completion of work and after necessary strainghtening, any repair as per the directives of EIC. |
| 9 | Dismantling structural steel work including doors, gates but excluding framedtruss etc. |
| 10 | Dismantling plain or corrugated steel sheeting any gauge, thickness, any pattern in roof coverings. |
| 11 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings. |
| 12 | Rough excavation, in soft/loose soil; n exc 1.5 m deep and n exc 1.5 m in depth and getting out. |
| 13 | Excavating over area, in soft/loose soil; n exc 1.5 m wide and n exc 1.5 m in depth and getting out. |
| 14 | Excavating in trenches, in soft/loose soil; n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out. |
| 15 | Boring holes 300mm dia, 4 m deep in soil for two under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m. |
| 16 | Removing excavated material n exc. 100m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 17 | M & L, Hardcore (Broken stone or boulders) of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface. |
| 18 | M & L, Cement concrete Type C2 1:3:6 (40 mm graded aggregate) in foundations, filling and mass concrete. |
| 19 | M&L, Providing cement concrete Type B-1, 1:2:4 (20mm graded aggrregate) in coping, slightly rounded or chamfered angles and throating including formwork and finishing of exposed face of concrete. |
| 20 | M & L,providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 21 | M & L, Providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses. |
| 22 | M & L, Providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 23 | M & L, Providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 24 | M & L, Providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in columns, pillars, piers, posts and struts etc. |
| 25 | M & L, Providing reinforced cement concrete (design mix) M-25 (20mm graded aggregate) in stairways including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, etc. |
| 26 | M & LBrickwork with subclass ‘B’ oldsize bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:4. |
| 27 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete flat. |
| 28 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, rough finished surfaces of concrete flat. |
| 29 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surfaces of concrete flat. |
| 30 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., rough finished surfaces of concrete flat. |
| 31 | Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing), rough finished surfaces of concrete flat. |
| 32 | Formwork to side of pillars, posts, struts, piers, columns and stanchions, fair finished surfaces of concrete, square, rectangular etc. |
| 33 | M & L, Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 34 | M&L, Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 35 | M & L, Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 36 | S&F, Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting orriveting, etc., and similar work conforming to Fe-290 Gde E-165. |
| 37 | S&F, Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. |
| 38 | S&F, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to woodtrusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165. |
| 39 | S&F, 1.60mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required. |
| 40 | S&F, Rolled mild steel of grade Fe 410 -W (Gde- E- 250) quality- A, in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 41 | Taking down chowkhat or frame not exc. 1.5 sq. m each but with shutters (without taking off shutters from the frames) and removal to store. |
| 42 | Taking down chowkhat or frame exc. 1.5 sq. m and not exc 4.0 sq m each but with shutters (without taking off shutters from the frames) and removal to store. |
| 43 | M&L, 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed |
| 44 | S&F, 30 mm 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats. |
| 45 | S&F, 35 mm, 2nd class HW rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated. |
| 46 | S&F Aluminium, anodised, barrel tower bolts 150mm length of extruded section. |
| 47 | S&F Aluminium, anodised, barrel tower bolts 200mm length of extruded section. |
| 48 | S&F, 300mm Mild steel, sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 boltsand nuts, four on bolt plate and two on staple plate and fixed. |
| 49 | S&F, 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy. |
| 50 | S&F M.S. butt hinges of 125mm size medium weight,cold rolledmild steel . |
| 51 | S&F, 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21. |
| 52 | S&F Extruded aluminium alloy handles, fabricated type, anodised of 150mm size cast type anodised. |
| 53 | S&F Extruded aluminium alloy handles, fabricated type, anodised of 100mm size cast type anodised. |
| 54 | S&F, 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 55 | S & F, Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm. |
| 56 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 57 | M & LRendering 10mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces and rendreing is to be finished even and smooth without using extra cement. |
| 58 | M & LRendering 15mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces and rendreing is to be finished even and smooth without using extra cement. |
| 59 | M & LRendering 10mm thick cement plaster 1:4 on fair faces of brick work or concrete surfaces and rendreing is to be finished even and smooth without using extra cement in ceilings. |
| 60 | Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in cement or cement lime mortar; not previously plastered; and scrubbing down with water etc. to receive plaster. |
| 61 | Preparation of old wall surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of 1st quality distemper oil emulsion as specified in clause 15.14.5 in MES SSR Pt-1 1991as directed by Engg In Charge. |
| 62 | Preparation of new wall surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of 1st quality distemper oil emulsion over Chalk whiting, on plastered surfaces, as specified in clause 15.14.5 in MES SSR Pt-1 1991as directed by Engg In Charge |
| 63 | Preparation of old ceiling surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of 1st quality distemper oil emulsion as specified in clause 15.14.5 in MES SSR Pt-1 1991 s directed by Engg In Charge |
| 64 | Preparation of new ceiling surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of 1st quality distemper oil emulsion over Chalk whiting, on plastered surfaces as specified in clause 15.14.5 in MES SSR Pt-1 1991and as directed by Engg In Charge |
| 65 | Preparation of old wall surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of cement paintspecified in clause 15.7 & 15.15in MES SSR part-1 1991 and as directed by Engg In Charge |
| 66 | Preparation of new wall surface including cracks filling up to 3mmplastered or unplastered brooming down etc and apply two coat of cement paintspecified in clause 15.7 & 15.15in MES SSR part-1 1991 and as directed by Engg In Charge |
| 67 | M & L, 25 mm thickCement concrete type B-0, 1:2:4 (12.5mm graded aggregate) finishing cement concrete surface even and smooth with out using extra cement. |
| 68 | M & L, 40 mm thickCement concrete type B-0, 1:2:4 (12.5mm graded aggregate) finishing cement concrete surface even and smooth with out using extra cement. |
| 69 | M & L, 70 mm thickCement concrete type B-1, 1:2:4 (20 mm graded aggregate) finishing cement concrete surface even and smooth with out using extra cement. |
| 70 | M & L, 100 mm thickCement concrete type B-1, 1:2:4 (20 mm graded aggregate) finishing cement concrete surface even and smooth with out using extra cement. |
| 71 | M&L, 28mm wide Glass dividing strips, 3 mm thick and inserted in position,conform to design. |
| 72 | Preparation of old wood and wooden base surface of any description over 10 cm girtth or width not otherwise described and apply two coat of 1st quality synthetic enamal paint and specified in clause 17.6 & 17.8in MES SSR part-1 1991 and as directed by Engg In Charge ( Make and colour as approved by Engg In Charge). |
| 73 | Preparation of new wood and wooden base surface of any description over 10 cm girtth or width not otherwise described and apply two coat of 1st quality synthetic enamal paint over priming coat of pink primer and specified in clause 17.6 & 17.8in MES SSR part-1 1991 and as directed by Engg In Charge ( Make and colour as approved by Engg In Charge). |
| 74 | Preparation of old steel surface of any description over 10 cm girtth or width not otherwise described and apply two coat of synthetic enamelpaint and specified in MES SSR part-1 1991 and as directed by Engg In Charge ( Make and colour as approved by Engg In Charge). |
| 75 | Preparation of New steel surface of any description over 10 cm girtth or width not otherwise described and apply two coat of synthetic enamelpaint after priming with red oxide and specified in MES SSR part-1 1991 and as directed by Engg In Charge |
| 76 | Preparation of old steel surface of any description over 10 cm girtth or width not otherwise described and apply two coat of Aluminiumpaint as specified in MES SSR part-1 1991 and s directed by Engg In Charge ( Make and colour as approved by Engg In Charge). |
| 77 | M&L, Writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high. |
| 78 | Disconnecting existing tanks (500LTR TANK) , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (DURING DISCONNECTING AND RE FIXING OF WATER TANK ANY DAMAGE TO FITTINGS, GI PIPE, FLOAT VALVE & WATER TANK ETC. WILL BE BORNE BY CONTRACTOR. ) |
| 79 | M&L, cutting out cracks to V-section in existing roofs or terrancing, cleaning out, wetting, grouting with cement and sand slurry 1:3. |
| 80 | M&L for providing APP basedPolymeric membrane roof treatment with following provisions complete all as specified and directed in accordance with manufacturer\"s instructions:- (a) Applying one coat of bituminous primer, polymerized primer oil based coat, evenly @ 0.3 Kg/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the based primer evaporated completely.(b) Applying APP based pre fabricated with non-woven polyester reinforced membrane stabilised with fibreglass strands, not less than 3mm thick, with 100mm side overlap and 150mm end overlap and not less than 3.0 Kg/Sqm by torch application method. |
| 81 | M&L, Providing, cement concrete in roof kerbs,haunching or mud stops, rounded or chamfered on edges type-B0, 1:2:4( 12.5mm graded aggregate). |
| 82 | M&L, Fair Straight orraking cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc.including inserting APP membrane ,rubbed finish and waste and Filleting in any position (section of fillet Exc. 25 but n exc. 50sqcm.) and to any shape in cement mortar 1:4 including all mitres, stops, etc. and fair finished surfaces. |
| 83 | Supply onlyLiquid water proofing compound of any reputed brand. |
| 84 | M&L, Preparation of surfaces of any description over 10 cm width or grith not otherwise described and apply one coat Heat resisting paint (BituminousAluminium paint.) |
| 85 | S & F, Pre- painted galvalume aluminumzinccoating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550Mpaasinroofcovering / claddingtowall,fixedwithself tapping screwsor L-TYPE or J-type as specifiedIS 1 5965approved & marked . with latest marking declared by the manufacturer.Make : TATA, JINDAL, JSW or equivalent. |
| 86 | S & FPre -paintedgalvalumealuminumzinccoatingGI basedPlain steel sheet0.50mm thickof anycolourhavingtensilestrength of 550 Mpa as in roofcovering/ cladding to wall, fixed with self tapping screws or L- type or J-typehookboltsasspecified.IS15965approved&marked.Withlatest marking declared by the manufacturer. Make : TATA, JINDAL, JSW or equivalent |
| 87 | S & F Rolled mild steel Fe-410-W(Gde-E-250) quality-B in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails etc.; fixed with angle cleats or other connecting plates. Make: TATA / JINDAL / SAIL or equivalent. |
| 88 | M & L for underdeck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and kraft paper (FSK), facing with 50 mm projection for overlap and butting comprising of the following:- (insulating material shall conform to BS - 476, Part 4,5, 6 & 7):-“(a) Supply and fix 6 mm dia M S rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof.“(b) Supply and fix 22 SWG GI wires supports for insulation.“(c) Supply and fix chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same |
| 89 | S & F Polycarbonate clear (or coloured as approved) transparent solid 2mm Thick Plain sheet, UV-Resistant surface on both sides, free from pin-holes & bubbles, pasting on insulation material using \"Both Side Self Adhesive Tape\" and fixing on roof / wall clading etc. with self tapping screws or L-type or J-type hook bolts as specified & directed. Insulation material shall be measured and paid for separately. |
| 90 | M&L, Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. |
| 91 | 15mm thick screed bed of 1:4 cement mortar set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 92 | S & F Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 93 | S&F Glazed ceramic coloured tiles (350 x 250 mm) x 7mm OR 450X350X7MMin wall, set and jointed in neat cement slurry and pointed in coloured cement to match. over10mm thick plaster on fair faces of wall, with 1:4 cement mortar. |
| 94 | M&L, applying3mm thick wall care putty on wall. |
| 95 | Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area N exc 150 sq cm. |
| 96 | S&F Solid PVC wood grain printed PVC sheet used Door frame of size 50 mm x 47 mm made out 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixed in opening as per specification & drawing. |
| 97 | S&Ffactory made Solid PVC Doorshutter wood grain printed PVC sheet 30 mmthick ( style) consisting of framemade outof M.S. square tube for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side etc. & fixing in the frame at site as per specification & drawing . |
| 98 | S& F of 500 ltr capacity rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed as per specification. |
| 99 | S&F, 15mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) |
| 100 | S & F of wash basins, vitreous China (flat back or angle back type) any size 550x400mm, including cutting for and pinning inn ends of brackets or erecting stand but exculsive of fixing of supply and waste pipe. |
| 101 | S&F, 32mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms) |
| 102 | S&F, 32mm Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm. |
| 103 | S & F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with PVC valveless syphonic action flusing cistern low level white with inlet ball valve, float and handle including brakets, flush pipe of polyethylene of low or high density PVC 32 mm dia. Fixing in repair |
| 104 | S&F, Vitreous China bowl type urinal flat back, sizeof 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe including connections to flushing pipeand outgoing pipes fixed in repairs. |
| 105 | S&F, 32mm Waste coupling of PTMT (half or full threaded) suitable forurinals, (Minimum weight 32mm-45gms) |
| 106 | S&F, Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 107 | Supply only, 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 108 | S&F, 10 litres PVC valveless, syphonicaction type, flushing cistern,low level, white, with inlet,ball valve, float and handleincluding brackets fixed in repair. |
| 109 | S&F 15 mm medium grade G.I. steel tubes, with all fitting and fixed complete to walls and ceiling or laid in floors. |
| 110 | S&F 20 mm medium grade G.I. steel tubes, with all fitting and fixed complete to walls and ceiling or laid in floors. |
| 111 | S & F 15 mmBib taps standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 90 gms) |
| 112 | S & F,15 mm Pillar taps of PTMT anycolour high pressurescrewedfor iron pipeand fixed.(Minimumweight 15mm-110gms) |
| 113 | S&F 15 mm dia Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms), screwed both ends for iron pipe& fixed. |
| 114 | S&F, Swivel shower of PTMT any colour forfixing with 15mm pipe. (Minimum weight40gms) |
| 115 | S&F, Shower arm 15 mm size, 195mm long withbend of 45degree with flange of PTMT anycolour.(Minimum weight 40gms |
| 116 | S&F 15 mm dia PVC connections with PTMT nuts of length 450mm. |
| 117 | S&F 15 mm dia PVC connections with PTMT nuts of length 600mm. |
| 118 | Supply & fixin repairs, 110 mm bore PVC (SWR) pipes, single socketed , in any length with rubber ring joints, fixed to walls/ceiling & including necessary clanps of required size etc complete all as specified & directed. |
| 119 | Supply & fixin repairs, 75 mm bore PVC (SWR) pipes, single socketed , in any length with rubber ring joints, fixed to walls/ceiling & including necessary clanps of required size etc complete all as specified & directed. |
| 120 | S&F 110 mm dia PVC (SWR) soil, waste and vent pipes single socketed,in any length with rubber ring joints, laid in trenches or in floors. |
| 121 | S&F 110 mm dia PVC (SWR) junction single, ( single T), equal or unequal. |
| 122 | S&F 75 mm dia PVC (SWR) junction single, ( single T), equal or unequal. |
| 123 | S&F 110 mm dia PVC (SWR) bends any radius. |
| 124 | S&F 75 mm dia PVC (SWR) bends any radius. |
| 125 | S&F 110 mm dia PVC (SWR) vent cowl. |
| 126 | S&F, 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement. |
| 127 | Credit of old dismantled mild steel of any description. |
| 128 | Credit of old brick works. |
| 129 | One light point/fan piont controlled by one switch wiring will be done with 1.50 sq.mm PVC insulated sheathed single core copper conductor cable drawn in and including PVC conduit of suitable diameter with IS 9537 (part III) 1983 marking medium grade including accessories surface in wall including PVC insulated, unsheated earth wire with copper conductor of size 1.50 sq mm, pressed steel terminal boxes sunk on wall for mounting of switches, sockets, fans regulator etc. including laminated sheet cover 3 mm thick complete, Make of cable - Anchor/Bontan/Finolex /Havells/Polycab/C&S/Standard or equivalent. PVC conduit : Plaza/Crown/Modi or equivalent. (Note: Red & black colour wire will be maintained for phase & nuetral, Maximum 6 point in each circuit ). |
| 130 | ------Ditto-----but One 3 pin socket outlet 5A point independent circuit. |
| 131 | ------Ditto-----but One 3 pin socket outlet 5A point on same board. |
| 132 | --------Ditto------ as per No.1 above but with 2.5 Sq.mm, (FRLS) PVC insulated copper condutor cable ( for socket outlet 15 amp. Independent circuit) |
| 133 | S&F switch piano, flush type 5A SP one way ISI Marked. Make: Anchor/SSK/Havell\"s/Polycab/C&S/Standardor equivalent. |
| 134 | S & F Switch socket combination outlet 3 pin, 5 & 15Amp, flush type Universal. Make: Anchor/SSK/Havell\"s/Polycab/C&S/Standardor equivalent. |
| 135 | Ceiling rose,3 terminal/PVC/polycarbonate, isolated bodywith M&L. Make: Anchor/SSK/Havell\"s/Polycab/C&S/Standard or equivalent. |
| 136 | S & FLamp Holder PVC/ polycorbonate type with back plate suitable for batten fitting complete.ISI Marked. Make: Anchor/SSK/Havell\"s/Polycab/C&S/Standard or equivalent. |
| 137 | S & F of single pole and neutralDB4 way, 240 volt IP 42 protection, metal double door, universal mounting with 200 Amps rated Bus bar, neutral bar, Earth bar and cable ties for cable management, top & bottom removable gland plates with blanking plates & all connections with copper lugs ISI Marked . DBshall consist of the following :(a) Incommer MCB \"C\" curveSPN 32 Amps, 240 volts AC, 10 KA ISI marked confermed to IS 8828 /IEC 60898 Qty - 1 Nos.(b) Out going MCB \"B\" curve SP 5 to 32 Amps 240 volt AC, 10KA ISI marked confermed to IS8828 /IEC 60898 Qty - 2 Nos.Make: Legrand/C&S/Polycab/SSK/Havell\"s/Anchor/Standard or equivalent. |
| 138 | S & F of single pole and neutralDB8 way, 240 volt IP 42 protection, metal double door, universal mounting with 200 Amps rated Bus bar, neutral bar, Earth bar and cable ties for cable management, top & bottom removable gland plates with blanking plates & all connections with copper lugs ISI Marked . DBshall consist of the following :(a) Incommer MCB \"C\" curveSPN 40 to 60 Amps, 240 volts AC, 10 KA ISI marked confermed to IS 8828 /IEC 60898 Qty - 1 Nos.(b) Out going MCB \"B\" curve SP 5 to 32 Amps 240 volt AC, 10KA ISI marked confermed to IS8828 /IEC 60898 Qty - 6 Nos.Make: Legrand/C&S/Polycab/SSK/Havell\"s/Anchor/Standard or equivalent. |
| 139 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Make: Alomberg, Brand Gorilla or equivalent of Maya/ Simartek. |
| 140 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make: Polycab/C&S/Phillips/Havells/Anchor or equivalent. |
| 141 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make: Polycab/C&S/Phillips/Havells/Anchor or equivalent. |
| 142 | Excavation in trenches not exceeding 0.5m wide and 0.75m depth and getting it out in soft/loose soil for laying of U/G cable. |
| 143 | Sand cushioning in cable trench 15 cm thick including material and labour. |
| 144 | S & L reinforcedprecast concrete cable cover class LV Type 2 flate size 300mmx180mmx40mm with M & L |
| 145 | Returning filling in including spreading, watering and well ramming in layers not exceeding 25cm. |
| 146 | S & L Tube medium grade galvanised 50 mm dia IS markedwith all fittings laid in trenches for protection u/g cables Make : TATA/Jindal/Zenith/Swastic or equivalent. |
| 147 | S & Lof 4 core XLPE insulated and armoured heavy duty cable with stranded Al conductor, 1100 voltage grade, size 25 sq mm including termination both the ends with proper lugs, glands. Make : Gloster/CCI/Havells/Finolex/poly-cab/Zenium or equivalent.. |
| 148 | Earthing complete with GI plate electrode 600x600x6.0mm thick burried directly in ground (earth plate not less than 2.25m below ground level) including excavation of soil, with top edge of the plate not less than 1.5m below normal ground level and duly filled with alternate layer of char coal & salt from 150mm below the plate to 150mm above the plate (total 900mm thick) connected to GI earth strip size 25x4mm in GI protection pipe of size 40mm dia upto 7.5m long by means of nuts, bolts, washers, check nuts of GI steel, fitted with funnel complete all as per procedure and as shown in SSR electrical plate No. 3. Connected to earth test point/earth bus (to be provided near incoming mains) all as specified and testing including RCCearth pit chamber duly cement plaster finished and RCC pit cover 1mX1mX150mm, PCC hard standing surrounding the earth pit chamber, location of the earth pit marked on the nearest wall to be written with paint (for distance & value of earth pit) with material and labour. Earth pit chamber will be made 0.5m above the ground level. |
| 149 | Supply & Fix switch with sheet steel inclosure 415/500V, 3 phase with HRC fuses complete with Neutral link of capacity 32 Amps.Make: English Electric/ SSK /C&S/Standard or equivalent. |
| 150 | Supply & Fix switch with sheet steel inclosure 415/500V, 3 phase with HRC fuses complete with Neutral link of capacity 32 Amps.Make: English Electric/ SSK /C&S/Standard or equivalent. |