Tender For Special Repair To Building No P 69 M 2 3 At Palampur Mil Station., palampur-Himachal Pradesh

Military Engineer Services has published Tender For Special Repair To Building No P 69 M 2 3 At Palampur Mil Station.. Submission Date for this Tender is 22-09-2025. Building Work Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50975063
Tender For Special Repair To Building No P 69 M 2 3 At Palampur Mil Station.
Tender
Indian
Himachal Pradesh
Palampur
22-09-2025

Tender Details

Tender For Special Repair To Building No P 69 M 2 3 At Palampur Mil Station.; 1 Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed 2 M&L rendering 15mm thick plaster on brick masonry/stone masonry on fair faces of brick wall in CM 1:4 finished even and fair without using extra cement complete all as specified and directed. 3 M&L preparation of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed. 4 Demolition ofbrickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed. 5 M&Lwalling of random rubble, un-courses, well bonded bedded & solidly hearted built in cement mortar 1:6, complete all as specified and directed. 6 All as per srl item No. 5 here-in-above but except stone. 7 Brick work with sub class B bricks, straight or curved on plan on exceeding 6m mean radius, using old size brick, built in cement mortar 1:6, complete all as specified and directed. 8 Providing precast cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM 1:6 complete with joints to match complete all as specified and directed. 9 M&L raking of joints/pointing to squared rubble masonry, coursed or uncoursed in walls in CM 1:3 complete all as specified and directed. 10 S&F PVC (SWR) pipe 75mm bore single socketed, in any length with rubber ring joints, fixed in walls including clamps at joints, top and bottom complete all as specified and directed. 11 Demolition of cement concreteunreinforced in ground floors, kota stone, granite flooring, tiles flooring andpavingsnot exceeding15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed. 12 M&L 75mm thick PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even and smooth with using extra cement complete all as specified and directed. 13 M&L 25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor/path surfaces finishing the surface even and smooth with using extra cement complete all as specified and directed. 14 Supplying & laying Multipurpose court 8 layer synthetic floor based on concrete/ asphalt surface cmplete all as manufacturess instruction with primer, resurfacer, cushion coat, ultra cushion coat, precoat, overline. Complete all as specified and directed. 8 Layers: Multipurpose court system:-Primer: 100% based emulsion to improve bond of acrylic coury system to the concrete or asphalt surfaces.Resurfacer: 1 resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for ITF approved tennis court system and also fills the surface chips voids and conceled repairs while providing a smooth surface for colour coating.Cushion Coat: 1 layer of cushion for asphalt or concrete surfaces in preparation of ITF approved system.Ultra Cushion Coat: 1 layer of cushion for asphalt or concrete surfaces in perparation of ITF approved system.Precoat: 2 layers of based texture topcoat ideal for colour coating Tennis courts and other sports pavement surfacesOverline: 10% based high hiding line paints. 15 Removing excavated soil n exc.50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. 16 Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed. 17 S&F steel work in tubular hollow section trusses including special shaped washer etc. compklete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. 18 M&L preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer, complete all as specified and directed. 19 M&L preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed by engr-in-charge. 20 M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed. 21 M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. 22 M&L laying chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors withgrey cement and pigment over 20cm screed bed in CM 1:6 complete all as specified and directed. 23 Dismantling of old rusted plain or corrugated steel sheeting, any gauge, thickness,including Nainital or similar pattern roof covering etc. complete all as specified and as directed. 24 S&F pre-painted galvalume aluminum zinc coating GIbased corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE) 25 M&L pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, facia and fixed with selftapping screws as specified. (Colour as approved by GE) 26 Dismantling timber scantlings 40Sq.cm and over in section, in any position complete all as specified and directed. 27 S&F second class soft wood in scantlings, clean sawn, timber fixed in repairs for wooden posts/purlins, trusses complete all as specified and directed. 28 S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 29 M&L rendering 15mm thick plaster in CM 1:4 with WPC on brick work or concrete surface or other than fair faces of brick masonry, finished the surface even and smooth without using extra cement complete all as specified and directed. 30 M&L rendering 10mm thick plaster in CM 1:6 on fair faces of brick work or concrete surface of brick masonry, finished the surface even and smooth without using extra cement complete all as specified and directed. 31 M&L preparation of newly plastered/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of cement base paint upto 15m height, complete all as specified and directed. 32 M&L preparation of old plastered/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of cement base paint upto 15m height, complete all as specified and directed. 33 M&L 50mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/foot path complete all as specified and directed. 34 M&L Vitrified Ceramic tiles 10mm thick (square / rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified. 35 M&L Glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/450mm x 350mm x 7mm/450x300x7mm/600x300x7mm thick set and jointed in neat cement slurry,pointed in white or coloured cement to match the colour of tiles, over and including 10mm thick backing coatin CM 1:4 to receive tiles including dismantling,complete all as specified and directed. 36 S&F 40mm thick E-board (Classic) false ceiling of size 610mm x 610mm fixed with GI snap grid frame work of size size as GI tee of size 25x25x1.50mm as main runner, 25x25x1.25mm thick GI tee as cross runner and GI angle of size 25x25x1.25mm at the perimeter, including 4mm GI adjustable suspender of required length, including dismantling complete all as specified and directed. 37 M&L GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed. 38 Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. 39 Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all asspecified and directed. 40 Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed. 41 M&L point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLSPVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and includingPVC concealed conduit / surface Casing Caping of suitable size incl all fittings such as Tee, connector pieces, L-junction etc on joints includingterminated boxes of Modular GI sheet Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement ) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. 42 Description all as per serial item No 40 here-in-before but one 5pin, 6 Amp socket outlet on same boardcomplete all as specified and directed. 43 Description all as per serial item No 40 here-in-before but one 5pin, 6 Amp socket outletindependent complete all as specified and directed. 44 Description all as per serial item No 40 here-in-before but for one 5 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm for phase and earth wire of size complete all as specified and directed. 45 S&Fbell, AC 230 Volts, single pole complete all as specified and directed. 46 S&F Modular Switch one way 6 Amp, one module 240 volts ISI marked complete all as specifiedand directed. 47 S&FSocket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. 48 S&F Socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. 49 S&F Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed. 50 S&F Modular white cover plate 8M complete all as specifiedand directed. 51 S&F Modular white cover plate 6M complete all as specifiedand directed. 52 S&F Modular white cover plate 3M complete all as specifiedand directed. 53 S&F Modular white cover plate 1M complete all as specifiedand directed. 54 S&Fceiling rose, 3 terminal surface type complete all as specifiedand directed. 55 S&Fangle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed. 56 S&F Decorative ultra slim LED Tubelight fitting4 Feetof LEDwith extruded polycarbonate, enviormental friendly energy efficient ready to use, 20watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor forelectrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. 57 Supply and FixLED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed. Crompton/havells/bajaj/orient or as approved by GE 58 M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 10 Sq mm for phase and neutral and one run of 10.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding. 59 S&F factory made CRCA sheet powder coated double door panel board 2mm thick, of size 50X50X16 cm, wall mounted type partially grouted in wall with locking arrangement, handle and making good disturbed surface as well as matching with existing whitewash color/surface and Fixing only existing 4 nos old energy meter with separate compartment including connection complete all as specified and directed. 60 M&Ldistribution board sheet steel powder coated for MCB with rated bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCBs should be same make. 61 S &F in replacementof SPN 40 Amp rating 240V, 10KA C curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 62 S &F in replacementof SPN 63 Amp rating 240V, 10KA C curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 63 S&F in replacement 240V, 10 KA C curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 64 S&F in replacement 240V, 10 KA C curve miniature circuit breaker (MCB) of single poles and current carrying capacityMCB SP 40 to 63 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 65 Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mmby means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrodeand including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thickwith 8mm dia TMT bars at 140mm C/C both ways,with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified. 66 Disconnecting/ Taking down Exhaust fan/Ceiling Fanof any sweep removing and cleaning the dust properly, painting with same colour good quality synthethic enemelled paint after preparing surface for painting with existing color shade oiling and greasing of bearing including refixing and making the conection and testingcomplete all as specified and directed. 67 Disconnecting electronic meters temper proof LCD display and taking in safe custody and refixing the same with caliberation and cleaning and making the conection and testingcomplete all as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail