Tender For Strengthening Upgradation Of Government Agriculture Work shop Talab Tillo, Jammu Under Css Scheme Rkvy Raftaar For Fy 2025-26- 1 Earth work in excavation by manual means in trenches for foundations, drains,pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soils: 2 Providing and filling river bed material in layers not exceeding 20 cm in depth, consolidating eachdeposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 3 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) 4 15mm Cement plasteron the rough side of single or half brick wall ofmix: 1 : 4 ( 1 cement : 4 coarse sand) 5 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2mm thick 6 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter 7 Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work 8 Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 9 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) 10 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. 11 Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 12 Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 13 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). 14 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcementwith 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete 16 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 17 Centering and shuttering including strutting, propping etc. and removal of form for. 18 Foundations, footings, bases of columns etc 19 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 20 Suspended floors, roofs, landings, balconies and access platforms. 21 Edges of slabs and breaks in floors and wallsUnder 20 cm wide 22 62mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 23 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. 24 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : Of area of 3 sqm. and below 25 Providing in positionOFFICE TABLE as per theper the design, material selectedby intendenting department and as specified by Engineer-in-charge (6x3) 26 Engaging of Labour for shifting of hardware material in store before and after work and dumping of unwanted material like old windows and mulba from site to dumping area. 27 Dismantling manually/ mechanically including stacking of serviceablematerial and disposal of unserviceable material within 50 meters lead asper direction of Engineer-in-charge: 28 Water bound macadam road. 29 Bituminous road. 30 Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50mmthick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 16.94.1 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 31 Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed withpigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : 32 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) 33 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) 34 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With ACP sheet 35 Providing and fixing glazing in aluminum door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With floating glass panes of 4.0 mm thickness (weight not lessthan 10.00 kg / sqm) 36 Providing and Fixing 0.50 wire gauge panelling fixed in aluminum doors windows shutters and partition frames 37 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(250x16mm) 38 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 39 (200x10mm) 40 (150x10mm) 41 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.(125mm) 42 125mm 43 100 mm 44 Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 45 125x75x4 mm 46 100x75x4 mm 47 Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 5mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws.Second class deodar wood 35 mm 48 Repair of L- shaped sofa set ncluding -polish of exposed wood change of all fabric and seat cushionsthe item shall be verified by the intending department before purchase. 49 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mmfor doors, windows and clerestory windows with ISI marked M.S. pressed butthinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge : Second class deodar wood 35 mm 50 Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 51 Providing and fixing of fabricated structure ceiling panels 40 mm thick with 0.63 mm hard dipped galavanised steel sheet on both sides with 50 mm thick layer of riged CFC free close cell polyurethene foam insulation density 40kg+- 2kg/sqm.(including all materials fixtures and fittings all complete job including labour. 52 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or crossbands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 53 Providing fixing of blinds for windows incl all fixtures and fitting and necessary arraangement etc complete job. (superior quality) 54 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) 12 mm thick Marine plywood conforming to IS: 710 55 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:2nd class teak wood 50 x 12 mm 56 Provding and fixing sunmica wood paper lam art sheets at walls including all cost of materials labour etc as per directions of Engineer-in-charge. 57 Engaging Electrician and Helper for refixing of switches,electric points, otherminor electrical works including cost of new materials if required. 58 Electrician 59 Helper 60 Providing and fixing UV stabilized fiberglass reinforced plastic sheetroofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’hooks, bolts and nuts 8mm dia. G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS: 10192 and IS: 12866. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2mm thick flat 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (600x600mm) 62 Carriage of materials (10km lead) 63 Sand 64 Aggregate Above 40mm 65 Aggregate Below 40mm 66 Brick