Tender For Additional 2Nd Operation Theatre On 6Th Floor Wing ‘A’ At Hbch&Rc, Mullanpur, New Chandigarh, Dist. Mohali, Punjab - 140901.; 1 civil 2 230 mm Brick work in Cement mortar 1:4 (1 cement :4 coarse sand)with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes including of Curing , site preparation mortar cleaning after work as per site requirements. 3 Provisding and applying 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) including rates of curing, surface preparation, cleaning of area after work etc. 4 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 5 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work 6 The Prefabricated operating room Ceiling will constructed from GalvanizedSteelinsulatedpanels.Thesepanelsareproducedinadoublebandlaminationinwhichtwo continuously moving belts of EGP Steel sheets of 0.8 + 0.5 mm are firmly bonded together. The core consists of rigid polyurethane foam, which has been injected under high pressure with a minimum density of 40 Kg / Sq M . Filling of all Joints and Cavities with Metallic Epoxy filler and Sanded flush to provide a joint less finish and then sprayed aseptic wall coating. AntiBacterial film – Silver based. 7 Providing and Fixing of SS Door With Single/Double leafframe size 1.050 m/1200 x 2.1 m x 44 mm thick , With vision panel and Including allaccesorries fixed with Floor spring or Hinges ,air tighting complete in all respect as per direction of Engineer InchargeSS Frame Size 1.5 mm x 120mm x 60 mm 8 Providing and fixing of SS Hermatic sealed Sliding Door fully Automatic and manuall operatedapprox size of 2.00 x 2.100 m. 9 ProvidingandFixing of2mmthickimportedvinylflooring,100%recycledflexiblehomogeneneousand monolayerinconstructionofweight2750g/m2andshouldbemanufacturedbycalenderingandpressing process of size 2 mts x 20 mtrs. in approved pattern, to ensure a dence , smooth surface and non directional design, color dyed as a raw mixture to ensure even color throughout to the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti bacterial and Fungicidal properties . The flooring shall incorporate a specially formulated Evercare TM Surface Treatment having wear resistance of <_ 2.0 mm3 as per EN 660.2 and wear Group T as per EN -649 and should have a residual indentation of - 0.03 mm confirming to EN - 433. The laid flooring shall confirm the fire rating B1 Class as per EN 13501-1. It should have low VOC contain as TVOC after 28 days < 10 Mg/M3 as per ISo 16000-6. The floor finish should terminate attheroom perimeterpassingoveraconcealed cover former andcontinuing upthewallfor 100mm.The joints in the flooring shold be sealed by using a PVC welding bar with flooring. The Vinyl sheet shall be laid & fixed with water based adhesive preferably AROBOND-44 of M/s. Arofine make or VC 31 of M/s. Pidilite Ind. or equivalent as per Manufacturers specifications and direction of Engineer - in -charge . 10 ProvidingandFixing of1.00 mmthickvinylwall cladding,100%recycledflexiblehomogeneneous, to ensure a dence , smooth surface and non directional design, color dyed as a raw mixture to ensure even color throughout to the thickness and its surface should be densely compacted for improving wear and ease of maintenance with Anti bacterial and Fungicidal properties . The joints in the wall shold be sealed by using a PVC welding bar with flooring. The Vinyl sheet shall be laid & fixed with water based adhesive preferably AROBOND-44 of M/s. Arofine make or VC 31 of M/s. Pidilite Ind. or equivalent as per Manufacturers specifications and direction of Engineer - in -charge . 11 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. 12 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 13 Dismantling tile,granite work in floors & wall andfalse ceiling including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 14 Lintel concrete Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 15 Centering and shuttering including strutting, propping etc. and removal of form for :Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 16 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 17 Providing and fixing of 12.5 mm thick tapered edge gypsumfalse ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 18 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 19 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 20 Plumbing 21 Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 23 Deg C)for pipes from 1/2 Inch to 2 Inch. Schedule 40 Pipe to be used from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846. ASTM F441 with only CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings.Installation shall be to as per Technical Manual of manufacturer of pipes & fittings. (Internal Hot & cold water supply) Cost shall be inclusive of making maximum of 7.5 x 7.5 cm chase in wall and floors for the pipe, making good the same by using 1:2 cement mortar over the wire meshand providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints complete as required. 22 20 mm nominal dia Pipes 23 25 mm nominal dia Pipes 24 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : 15mm nominal bore. 25 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 26 Providing and fixing ball valve (brass) 20 mm nominal bore dia of approved quality, High or low pressure, with plastic floats complete 27 Providing and fixing ball valve (brass) 25 mm nominal bore of approved quality, High or low pressure, with plastic floats complete : 28 Providing ,fixing, jointing and testing in positionthe single socket type ‘B’ UPVC pipe for soil, waste and vent installation conforming to IS:13592cut to required lengths including all necessary fittings and specials such as ends,junctions,offsets,end plug, access pieces(plain or door) & single/double- Y .Fixing at wall/ceiling level, below floor level supported byheavy duty GIclamps & hangers,PCC pedestal etc. Making proper connection with rubber seal & lubricant joint of required depth including cutting, chases/holes in floors/walls/slab etc and making good the same after pipe have been duly laid and testing complete.110 mm dia (For soil stack) 29 Providing and fixing of 2 bay Stainless Steel (SS 304 Grade ) Scrub StationAutomatic and foot oprated. As directed by Engineer in charge. 30 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete 31 Providing and fixing 100 mm sand cast Iron grating for gully trap. 32 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 33 Mech. 34 Air Handling units Make - EDGETECH/System Air/CRISTAL(Eurovent Certified) 35 SITC of 50 mm thick Double skin floor mounted TWO TIER Horizontal Air Handling units with thermal break profile,and separate supply fan and return fan along with VCD as specified and Duty Conditions as per specification with 8 RD cooling coil & 2 RD heating coil ,pan type humidifier provision & all other accessories like, pre-filters and additional filtration if required as specified below,outlet cancass connections, Mixing boxes (wherever specified) as under. Units to be suppliedalong with DIDW fan., factory fabricated & assembled made of extruded anodised aluminium hollow sections to make a rigid frame structure. The frame shall be assembled using pressure die cast aluminium joints. The self supporting unit shall consist of sandwiched panel made out of 0.6mm thick pre-plasticide / pre-coated GI sheet outside &0.6mm GI sheet inside (0.6 mm polished stainless steel in case of AHU for Operation Theatre) duly factory fabricated insulated with 23 / 48 mm thick PU foam insulation in between as specified in Bill of Quantities. The insulated panels shall be bolted to mainframe with neoprene rubber gaskets held captive in the framed extrusion to make it leak proof. Suitable airtight access doors / panels with pressure die cast aluminium hinges & nylon handles and locks shall be provided for access to various sections for maintenance. The Entire housing shall be mounted on Extruded Aluminium channel framework having pressure die cast aluminium jointers or the framework shall be joined together with corner plates Condensate. Drain Pan shall be constructed of 18 gauge Stainless steel sheet with all corners welded with uniform slope from all sides leading to drain pan ensuring no stagnation of condensate water. Motor & DriveThe fan motors shall be suitable for 415 ± 10% volts, 50 ± 5 % HZ, 3 phases TEFC SQ. Cage induction motor. The motor shall be specially designed for quiet operation & motor speed shall not exceed 1440 RPM. Drive to fan shall be provided through belt drive arrangement.The fan and motor should be supported on a common base frame supported on spring mounts housed inside the fan section of the AHU. Motors to be energy efficient.Units shall be supplied with additional stand by motors and drive sets.All AHUs to be supplied with dedicated electrical starter panel power/control cabling upto 15 RMT for each ahu. (From electrical panel to AHU motor) including earthing between motor and panel.Technical details as per tender specifications. Filters section for supply section and exhaust section: Make -- MECHMAARK / EQUIVALENT Filter section with 50 mm thick box type pre-filter (MERV-8) & 305 mm thick rigid media type fine filter (MERV-13) mounted on a common filter frame. heat recovery wheel. Make : Ostberg FAN (DIDW Type) Make -- NICOTRA / KRUGER / GREENHECK / EQUIVALENT AC MOTOR (FOR DIDW FANs) Make -- ABB / SIEMENS / BHARAT BIJLEE / HAVELLS efficiency Factor -- IE-2 Cooling and Heating COIL Tube Material -- Copper Tube Thickness -- 0.3 mm Outside dia. -- 9.5 mm Header material -- Copper Coil Casing – GI Blank-off material – GI Fin Material -- Plain Aluminium Fin spacing -- 11-13 FPI Condensing tray -- 18G SS-304 Test Pressure -- 38Kg/Sq.cm.Insulation Material for Drain Tray--25mm thick close cell Nitrile Rubber.The casing shall have heavy gauge GI construction forward curved DIDW imported fan statically & dynamically balanced mounted on EN8 solid shaft or C 40 carbon steel. The supply air DIDW fan shall be forward / backward curved as per BOQ. The fan impeller shall be supported to housing with angle iron frame & pillow block heavy duty ball bearing. The fan shall be selected for a fan outlet velocity below 10 meter / sec. The fan housing with TEFC Sq. Cage motor shall be mounted on a common adjustable base frame on vibration isolators in case the impeller diameter is exceeding 450 mm & rubber turret mounts vibration isolators for fan diameter up to 450mm diameter. The fan motor shall be installed inside the housing of air handling unit to keep low noise level. The fan & motor assembly shall be of aluminum extruded section only.The cooling & heating coil shall be made of aluminium fins and copper tubes of dia.12.5mm or 16mm OD. The minimum no. of fins / cm for cooling coils shall be 4.7 & for heating coil it shall be 2.4. The bonding of aluminium fins with copper should be done hydraulically. The tube thickness shall be 26 G & fin thickness shall be 37 G. The cooling / heating coil should be tested for leaks at a hydraulic pressure of at least 10 Kg / sq.cm. for a minimum period of 3 hours at works. The velocity across face should be limited to 152 metre / minute. In case of chilled / hot water coils the design should be such to limit water velocity to maximum of 2.5m/sFINE FILTER+HRW(4000 CFM/3600 CFM) 150mm SP, 18 TR 36 SITC OF UVGI .CoiloTron / UVC Emitters System inside the floor mounted AHU with accessories shall be included to reduce mold and fungus growth on the coil / drain pan and keep the coil surface clean. Emitters shall be Double Ended Type and each fixture shall have 2 lamps. The lamps shall be high output type 425 mA each. Energy output of the lamp measured 33 (1M) from the Lamp shall not be less than 144 μwpercm². The lamps shall be rated for useful lamp life not less than 11,000 hours Make- Magneto/ Ultrapure. 37 OT SUPPLY MODULEMake - AIRTECH SHEETALUMINIUM HINDALCO/ NALCOSSJINDAL 38 SITC of laminar flow cabinet OT module made out of SS 316 with terminal H14 minipleat hepa filters and aluminium powder coated perforated Grille.Filters shall be considered with a minimum pressure drop Not exceeding 25 mm wc, The module to be suaitable for aluminium low leakage volume control dampers at the inlet of the module, central opening for OT light pendents also to be considered. necessary GA drawings / technical specs to be approved before procurement. These modules to be suitable for ceiling suspension and necessary hooks / fitting arrangements to be provided to install these units along with filters pressure testing, filter integrity testing ports. The inlet connetion size to the Plenum shall be design with a limitation of velocity not exceding 700 fpm.Necessary GA drawings / technical specs to be approved before procurement. This item also include OT validation and neccessary testing of Hepa filteres. Technical details as per tender specifications. 39 2500X1750X450 approxMake Air tech 40 OT RETURN AIR RISERS make- AIRTECH SHEETALUMINIUM HINDALCO/ NALCOSSJINDAL 41 SITC of OT Return air Risers made out aluminium of about 3 mtrs height and bottom filter, collar damper and perforated grill fixing arrangment, complete with pre filter of 20 micron, suitable filter removal arrangement.The filter shall be flange type with outer dimension of 600 x 600 mm complete with perforated grills and grill fixing arrangement.Riser to be insulated with nitrile rubber of 9 mm thickness with suitable adhesive. necessary GA drawings / technical specs to be approved before procurement.Technical details as per tender specifications. 42 DUCTING -AIR CONDITIONING-For OT Make -HINDALCO/ NALCO/BIRGO 43 Supply,installation,testing and commissioning of Aluminium ducting with turning vanes, Aluminium supporting arrangement as per IS 655 and the detailed specifications For OT I.Technical details as per tender specifications. 44 22G 45 THERMAL INSULATION-DUCTS Make - A FLEX, ARMACELL 46 Supply, Installation of thermal insulation of closed cell polyethylene insulation with aluminium foil of the required density and thickness as mentioned in the technical specifications.Technical details as per tender specifications. Note: Insulation thickness mentioned in the specification is only for guidance purpose.Vendor should confirm/select the insulation thickness based on insulation selection calculation from the manufacturer.However the thickness of insulation shall not be less than what is specified in the technical specification. 13mm Thick 47 VOLUME CONTROL DAMPERS Make-AIRFLOW/SYSTEMAIR 48 Supply, installation, testing and commissioning of Extruded Aluminium low leakage multiblade type opposed blade volume control dampers with aerofoil blades and nylon bushes alongwith indication of percent area of opening and having locking arrangement as per approved drawing & specification.Technical details as per tender specifications. 49 FOR LEMINAR 50 MOTORISED FIRE AND SMOKE DAMPERS Make-AIRFLOW/SYSTEMAIR/Dynacraft 51 Supply, installation, testing and commissioning of Motorized fire damper as per approved drawing & specification.Technical details as per tender specifications. 52 ACTUATORS FOR MOTORISED DAMPERS Make -BALIMO 53 Supply , Installation of Actuators for Motorized dampers with wiring, conduits between controller & damper actuator.Technical details as per tender specifications. 54 CHILLED WATER PIPING : make - JINDAL/sail/zenith/tata 55 SITC of Chilled water piping carried out of MS Class C pipes as per IS 1239 for pipes up to 150 mm NB and as per IS 3589 for 200 mm NB and above as per specs and insulated with nitrile rubber of required thickness 25mm thick density 32kg/cu m.Technical details as per tender specifications. Note: Insulation thickness mentioned in the specification is only for guidance purpose.Vendor should confirm/select the insulation thickness based on insulation selection calculation from the manufacturer.However the thickness of insulation shall not be less than what is specified in the technical specification. 56 50 mm NB 57 DRAIN PIPE make - JINDAL/sail/zenith/tata 58 SITC of Drain piping carried out of GI Class B pipes as per IS 1239 and duly insulated with 19 mm thick Nitrile Rubber as per specifications.Technical details as per tender specifications. Note: Insulation thickness mentioned in the specification is only for guidance purpose.Vendor should confirm/select the insulation thickness based on insulation selection calculation from the manufacturer.However the thickness of insulation shall not be less than what is specified in the technical specification. 59 40 mm NB 60 INSULATED BUTTERFLY VALVE Make - Audco/Danfoss/Advance/Castle/Kitz 61 SITC OF Insulated Butterfly valves together with accessories like flanges, fasteners, etc.Technical details as per specifications.Technical details as per tender specifications. 62 50 mm NB 63 PIBC VALVES MAKE - Danfoss/Simens/Flowcon 64 SITC of InsulatedPIBCV suitable for digital pressure read-outs, together with accessories like flanges, fasteners, etc.Technical details as per tender specifications. 65 50 mm NB 66 Y STRAINER Make - SANT/leaer/Rapid cool / DS Engg/ Emerald 67 SITC of Insulated Y type - Strainer with necessary accessories like flanges, fasteners, etc.Technical details as per specifications.Technical details as per tender specifications. 68 50 mm NB 69 SITC of Air Vent complete with pipe nipples, 20 mm NBball valve, etc.Technical details as per tender specifications. Make -ANERGY/ Rapid control / Airtech 70 SITC of 100 mm dial pressure gages, complete with siphon and pet cock.Technical details as per tender specifications. Make - H GURU/Japsin/eEmerald 71 SITC of Marcury type temperature gagesas per specification. (Range 0 - 50°C).Technical details as per tender specifications. Make - H GURU/Emerald/Taylor 72 SITC of 25 mm gate valve-drainTechnical details as per tender specifications. Make -LEDER/ZOLOTO 73 SITC of Hot water piping carried out of MS Class C pipes as per IS 1239 for pipes up to 150 mm NB and as per IS 3589 for 200 mm NB and above as per specs. and insulated with nitrile rubber of required thickness 25mm thick density 32kg/cu m mentioned in the technical specifications.Technical details as per tender specifications.Note: Insulation thickness mentioned in the specification is only for guidance purpose.Vendor should confirm/select the insulation thickness based on insulation selection calculation from the manufacturer.However the thickness of insulation shall not be less than what is specified in the technical specification. MAKE -JINDAL/sail/zenith/tata 74 40 mm NB 75 DRAIN PIPE make - JINDAL/sail/zenith/tata 76 SITC of Drain piping carried out of GI Class B pipes as per IS 1239 and duly insulated with 19 mm thick Nitrile Rubber as per specifications.Technical details as per tender specifications.Note: Insulation thickness mentioned in the specification is only for guidance purpose.Vendor should confirm/select the insulation thickness based on insulation selection calculation from the manufacturer.However the thickness of insulation shall not be less than what is specified in the technical specification. 77 32 mm NB 78 BALL VALVE MAKE- LEDER/ZOLOTO/GG/Rpide Control 79 SITC of Insulated Butterfly valves together with accessories like flanges, fasteners, etc.Technical details as per tender specifications. 80 40 mm NB 81 PIBC VALVES MAKE - Danfoss/Simens/Flowcon 82 SITC of InsulatedPIBC valvesuitable for digital pressure read-outs, together with accessories like flanges, fasteners, etc.Technical details as per tender specifications. 83 40 mm NB 84 Y STRAINER make - SANT/leaer/Rapid cool / DS Engg/ Emerald 85 SITC of Insulated Y type - Strainer with necessary accessories like flanges, fasteners, etc.Technical details as per tender specifications. 86 40 mm NB 87 SITC of Air Vent complete with pipe nipples, 20 mm NBball valve, etc.Technical details as per tender specifications. make -ANERGY/ Rapid control / Airtech 88 SITC of 100 mm dial pressure gages, complete with siphon and pet cock.Technical details as per tender specifications. Make - H GURU/Japsin/eEmerald 89 SITC of Marcury type temperature gagesas per specification. (Range 0 - 50°C).Technical details as per tender specifications. Make - H GURU/Emerald/Taylor 90 SITC of 25 mm gate valve-drain Technical details as per tender specifications. Make -LEDER/ZOLOTO 91 SITC ofAHU electrical PANEL with By Pass arrangement of VFD and VFD space in Panel ( Where AHU haveSupply air and Return Airfan both) make - SPC/ADVANCE/SYSTEM POWER CONTROL 92 5.5/2.2 Kw/HRW/HUMIDITIFIRE/UVGI 93 INCOMING : 94 a.63 A TP MCCB --- 01 Set. 95 b.RYB LED type indicationlights --- 01 Set. 96 c. Digital Type Voltmeter (0-500)V --- 01 Set. 97 BUSBARS : 98 Electrolytic grade (E 91 E),63 Acapacity TPNaluminiumbusbar,PVCheat shrunk insulated, supportedonDMC/SMChaving fault level of 25 KA for 1 second. 99 OUTGOING : 100 a.63ATPMCBfor0.5/0.75/1/ 1.5/ 2/ 3/4/5/6/7/8HPmotor,a fully automaticDOLstarterwithbuiltinsingle phasingpreventer and overloadrelay, digital typeammeter with CTs & selector switch, a set of LED type ON& OFFindicationlights& START-STOP push buttons -02 sets. 101 b.Auto-Manual typeselectorswitchtofacilitate autostartoffansafterrestorationofpower -- 02 Sets. 102 c.Controlwiring& safety circuitas required withStart-Stop PBs stayput orlockabletypeandLED type ON OFF indication lights. 103 SITC of VFD Controller module with RS 405 port compatible with BMS MAKE -FUJI ELECTRIC /ABB/L&T 104 5.5 kw 105 2.2 kw 106 SITC of PAN HUMIDIFIRE 107 A pan type humidifier of required capacity as specified in bill of quantities shall be provided. The pan type humidified shall be constructed from 1 mm thick stainless sheet SS-304 with top cover openable for maintenance. The humidifier shall be complete with quick fill, make up overflow & drain connections. The humidifier shall be insulated with fibre glass of density 32 kg/cm2 & shall be cladded with 22G thick aluminium sheet. The humidifier is divided in two chambers from inside, one bank of heater is always kept on to maintain water temperature between 60 to 70 ºC with thermostat. All controls such as low level cut out, thermostat, float valve shall be provided. It shall be factory wired & tested. The humidifier shall have its own powder coated electrical panel made of 16 G CRCA sheet complete with contactors, MCB Low level cutout, Heating thermostat, fault indicating lamp, high temperature cutout etc. & internally wired 108 SITC of pan humidifire piping work 109 SITC of Copper Power Cabling and control cabling starter panel to AHU with end termination as mentionedbelow 110 3CX6 sqmm for AHU motor and return/exhaust air motor 111 4CX2.5 Sqmm for pan humdifier 112 3Cx2.5 Sqmm for HRW 113 4CX1.5 Sqmm for fire damper & Limit switch 114 2CX1.5 For PIBCV & UVGI 115 GI wire for Earthing 8G 116 Modification and re-routing of existing ducting of Sterile store as per site condition and as decided by Engineer-in-Charge 117 G I Ducts SITC of GI sheet metal of standard dimonsion(900x2500, 1000x2500, 1200x2500)for HVAC ducting work of following sizes for supply air & return air system . The Gl sheets shall be hot dip galvanized with coatling of minimum 120 grams per square meter (GSM) of Zinc. Make : Tata/Sail/Jindal/AMNS/Asian 118 22 G 119 Thermal lnsulationSITC Of closed cell nitrile rubber thermal Insulation Class o for duct Insulation Of standarddimentlon). Material should be supplied in rolls. Make , APL/AFlex / Kflex /Armacell / Aerofoam 120 13 mm 121 Labour rate contract for installation, testing and commissioning of GI duct 22 G. 122 Labour rate contract for installation, testing and commissioning of thermal insulation XLPE 123 Existing fire fighting pipe line removal and blanking main fire fighting system pipe line 124 SCRAFFOLDING CHARGES for AHU Ducting work 125 Shifting, Cutting,welding, Installation, Testing and commissioning ofthefollowingMSclass‘C’pipesof followingdiameterandof6mtr standard lengths for Chilled water lines including insulation. 50 MM Dia 126 Opening, repairing and fixing in brick wall for supply and return air duct 127 Hub room/ UPS room split AC out door shifting and testing, commissioning all work vendor scope. 128 SITC OF Copper pipe with insullation and wire for split Acs. 129 SCRAFFOLDING CHARGES for Split AC out door shifting work 130 Supply and testing of Split AC drain pump 131 MGPS 132 Supply & Installation, Testing and Commissioning of double Articulated arm Anaesthesia moveable arm pendant with 800mm long arm having weight carrying capacity of 150 Kg, Six electrical sockets 5/15 ampere, one data point, two adjustable shelves , one drawer with shelf and 6 nos. of gas outlets O2-2 nos. , Air 4 bar - 1 Nos.Vacuum -2Nos, N2O- 1 Nos. & AGSS- 1 Nos outlet. Medical Infusion IV pole - One set. Make - Drager, 133 Supply & Installation, Testing and Commissioning of double Articulated arm Surgeon pendant with 800mm long arm having weight carrying capacity of 150 Kg, Eight electrical sockets 5/15 ampere, one data point, two adjustable shelves , one drawer with shelf and gas outlets O2-2 nos. , Air 4 bar - 1 Nos.Vacuum -2Nos, N2O- 1 Nos. & AGSS- 1 Nos outlet. 134 SITC OF Terminal Units (Gas Outlets) with O2 flowmeter, Vaccum unit, probes/Adaptors as per NFPA, CSA UL Listeed as per NFPA 99. Make- Aktive/ MR 135 Oxygen 136 Vacuum 137 Air(4 Bar) 138 Air(7 Bar) 139 N2O 140 CO2 141 SITC of Copper pipes used will be solid drawn, seamless, deoxidized, non arsenical, half hard, tempred and degreased, manufactured as per EN 1057 PART I , Table- x of 1971 and chemical composition as per BS-6017 of 1981. Make- Mexflow/Mandev/Janya 142 28mm OD * 1mm thk 143 22mm OD * 1mm thk 144 15mm OD * 1mm thk 145 12mm OD * 1mm thk 146 SITC of Valves Boxes with pressure gaugesMake- Aktive/ MR 147 6 Gas Services (O2, Vac, N2O, Air 4, Air 7, CO2) 148 SITC of Area Alarm Make- Aktive/ MR or 149 6 Gas Services (O2, Vac, N2O, Air 4, Air 7, CO2) 150 Electrical 151 Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Make: Polycab/Havels/KEI/RR Kabel/FinolexOverall size 25sq.mm (3½ Core) Armoured (On-Surface) 152 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Make: Dowel/Braco/Comet3½ X 25 sq. mm (28mm) 153 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . Make: Schneider/L&T/Legrand8 way (4 + 24), Double door 154 Supply and erection of Miniature Circuit Breaker MCBs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-Make: L&T/Schneider/LegrandMCB Four Pole63amp. (10kA, Curve-C) 155 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: L&T/Schneider/Legrand40 A 156 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: L&T/Schneider/LegrandSingle pole (20A MCB) 157 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.Make: Polycab/Havels/KEI/RR Kabel2 X 4 sq. mm + 1 X 4 sq. mm earth wire 158 Supplying and fixing suitable size weather proof IP66/IP65 box on surface or in recess, including providing and fixing modular socket outlet and modular switch, connection etc. as required.Make: Legrand (Grey Plexo box & adaptor with PVC membrane - 3 module)16A Socket controlled with 16A switch 159 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: L&T/Schneider/Legrand25 A 160 Supplying and fixing suitable size weather proof IP66/IP65 box on surface or in recess, of 2 pole for DP RCCB with connection etc. as required.Make: Legrand (Plexo3 boxes for DX3) 161 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make: Conduit - AKG/BEC/PrecisionWire - Polycab/Havells/KEIGroup C (Primary Point) 162 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.Group C ( Secondary Point) 163 Supplying and fixing suitable size weather proof IP66/IP65 box on surface or in recess, including providing and fixing modular socket outlet and modular switch, connection etc. as required.Make: Legrand (Grey Plexo box & adaptor with PVC membrane - 2 module)Modular RJ-45 Modem Jack for Computer (One Module) 164 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required.Make: Commscope/Schneider/Molex/beldon1 run of Cable 165 Providing & Fixing of LED slim type two film X-ray viewer box with digital clock with minimum size of 800 X 450 mm, flush in wall, IP 65 or above. 166 Providing & fixing of Recessed mounted clean room luminaire with 1x 30W lamp, (600mm x 600mm), CCT (K) 6500.Make: Wipro 167 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. (For AHU at Terrace floor)Upto 35 sq. mm (clamped with 1mm thick saddle) 168 Supply of 4core 10 sq. mm PVC insulated FRLS-H copper armoured cable 1.1 kv grade, as per IS standards (For AHU). Make: Polycab/KEI/Havells/RR Kabel 169 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required. (For AHU at Terrace floor & 6th floor Electrical room to UPS room)150 mm width X 50 mm depth X 1.6 mm thickness 170 SITC of chemical earthing (Chemical to enhance earth bonding improving compound) using copper earth electrod of tube/rod of 3 Mtrs Length including chamber with cover etc as required. 171 Providing & Laying of 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable (for earthing) 172 Supply and erection of heavy duty 10 sq. mm Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely. 173 Supplying and fixing of following sizes of medium class PVC/Steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 174 Supplying and fixing FP sheet steel enclosure on surface/ recess along with63 amps 415 volts “C” curve FP MCB complete with connections, testing and commissioning etc. as required. 175 Surgeon Control Panel:Providing & Fixing of touch screen surgeon control panel, flush in wall, with sensors, comprising of all following:Day Time ClockLapse Time ClockDimmer Set for peripheral internal lightHands free telephone (Compatible with SIP/IP EPABX Telephone exchange)Medical Gases status/AlarmIndicator and Control for temperature and humidityIndicator for Hepa filter statusNote: Should have Bypass arrangement in case of control panel malfunction. 176 Local Patient Call system:Supply, Installation, Testing & Commissioning of LAN based Content Management Software must have Integrate with HIS, Multi user Login with role based access, real time monitering of display status, Data security with password protection and encrypted transfer, customise templet for OT schedule board & Emergency alert override, including 43 inches LED Display with ceiling mounting kit, Android 12.0 and above, 4GB Ram, 32 GB memory, Ports- 2xHDMI, 1xUSB, 1xRS232, 1xRJ45, 1xDVI-D, 1xVGA. Brightness-(nits) 350, Contrast Ratio 5000:01:00, The whole system must be in a metal enclosure with all required accessories and connecting cables (HDMI/VGA/USB/LAN/etc) for display to PC. 177 SITC of 24 Port Cat6 Patch panel, fully loaded, rack mount complete with I/O socketMake: Commscope/Schneider/Molex/beldon/Legrand 178 SITC of Toll-less RJ 45 I/O socket outlet including cover/face plate.Make: Schneider/Molex/beldon/Legrand