Tender For Comprehensive Repair And Maintenance To Of Day To Day Complaint Of Internal Electrification Of D-I And D-Ii Zone Area Under Aor Of Ge(S) Mamun; 1 Identifying and rectifyingthe defects pertaining to internal electrification of any type and nature such as taking down defective switch / socket / ceiling rose / lampholders / fan regulator / bell push / LED fitting such as tube light / mirror light /building security light / bulk head / decorative light,call bell / MCB SP / SPN / fittings / fixtures any type, rectification of faulty electric circuits,tightening of loose connections etc. and re-fixing in same position, making good the disturbed surfaces, wall, floors etc to match existing one complete all as specified and directed. 2 Identifying and rectifyingthe defects pertaining to internal electrification of any type and nature such as taking down defective Bakelite sheet of any size / sunken steel box of any size/ MCCBs of any type, rectification of faulty electric circuits,tightening of loose connections etc. Cutting chases, grouting in wall, making good the disturbed surfaces to match existing one, wall, etcshall be deemed included in quoted rate of this item, complete all as specified and directed. 3 NOTES FOR ITEM NO 1 to 2 :-(a)All T&P, Stationeries and trained / skilled manpower will be provided by the contractor for both the complaint cells on daily basis, as directed.(b) Rep of the contractor will collect the complaints at 08.30 Hrs to 04.30 Hrs from complaint cells and attend the complaints immediately. (c) Cost of minor stores such as screws, clamps, insulation tapes, nuts/bolts, thimbels of required size etc shall be deemed to be included in the above quoted item. However, major items such as switch / socket / ceiling rose / holders / fan regulator / bell push / LED fitting such as tube light / mirror light /building security light / bulk head / decorative light,call bell / MCB SP / SPN / fittings / fixtures any type /Bakelite sheet of any size / sunken steel box of any size / MCCBs of any type etc shall be measured and paid separately as Supply onlyunder appropriate items of Schedule A.(d)If contractor fails to rectify the complaint with in 24 hours after reciving, a recovery @ Rs 500/- per complaint shall be made from contractors dues. 4 Supply only switch piano flush button single pole, one way 6 Amps, 240 volts polycarbonate body complete all as specified and directed. 5 Supply only switchpiano, flush button, single pole two way, 6 amps 240 Volt, polycarbonate body complete all as specified and directed. 6 Supply only bell push switch, piano flush button single pole, one way, 5 Amps 240 volts polycarbonate body complete all as specified and directed. 7 Supply only socket outletmulti purpose 2 & 3 pin, 6 Amp, 230 Volts flush type complete all as specified and directed. 8 Supply onlysocket outlet 2 in 1, 3 pin, 6 & 16 Amps, flush type, single pole, oneway,230 Volts complete all as specified and directed. 9 Supply only switch piano, flush type, single pole, oneway, 16 Amps230 Volts complete all as specified and directed. 10 Supply only stepped type two modular electronic mini/deluxe fan regulator 100 watt rotary step complete all as specified and directed. 11 Supply only ceiling rose, 3 phase PVC / polycarbonate, isolated body complete all as specified and directed. 12 Supply onlylamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete complete all as specified and directed. 13 Supply only modular switch, one module,1 way, 10 Amps 240 volts complete all as specified and directed. 14 Supply only modular switch, one module,1 way, 16 Amps 240 volts complete all as specified and directed. 15 Supply only modular bell push 6 Amp, 240 volts, 1 Module complete all as specified and directed. 16 Supply only modular switch, two way,6 Amp, 240 volts, 1 Module complete all as specified and directed. 17 Supply only modular socket, 6 Amp, 240 volts, 2 & 3 pin,2 module, complete all as specified and directed. 18 Supply only modular socket, 6 Amp, &16 Amp, 240 volts, 2 & 3 pin, 2 Module complete all as specified and directed. 19 Supply only modular step type fan regulator 120W, 240 volts,2 Module, complete all as specified and directed. 20 Supply only Bell, Ding Dong AC, 230 volts, single pole complete all as specified & directed. 21 Supply only MCCB 63 Amps, 4 pole, 240 volts, 50 KA complete all as specified and directed. 22 Supply only MCB single pole and neutral, 40 Amps, 240 volts, B-series complete all as specified and directed. 23 Supply only MCB single pole 16 to 32 Amps, 240 volts, B-series complete all as specified and directed. 24 Supply only bakelite sheet of size 5x5 for mounting switches/sockets etc. complete all as specified and directed. 25 Supply only bakelite sheet of size 8x5for mounting switches/sockets etc. complete all as specified and directed. 26 Supply only bakelite sheet of size 10x12 for mounting switches/sockets etc. complete all as specified and directed. 27 Supply only bakelite sheet of size 8x10 for mounting switches/sockets etc. complete all as specified and directed. 28 Supply only sunken steel box, zinc oxide plated of size 4x4 complete all as specified and directed. 29 Supply only sunken steel box, zinc oxide plated of size 7x4 complete all as specified and directed. 30 Supply only sunken steel box, zinc oxide plated of size 9x11 complete all as specified and directed. 31 Supply only sunken steel box, zinc oxide plated of size 7x9complete all as specified and directed. 32 Supply only LED Lamp of 9W, Base B22, BEE 3 Star complete all as specified and directed. 33 Supply only LED tube light fittings (4 feet long), wall mounted 1x20 watt6500K, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficientwith all accessories and making connection using 2 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. 34 Supply only LED light fitting, mirror type with high out put diffuser, 2 feet,10 watt, 220 volt, AC, decorative type with driver holder and LED lamp including three core flexible copper conductor cable of suitable size complete all as specified and directed. 35 Supply only LED Bulk Head luminaries, 10W complete with all accessories and including connector and twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete. 36 Supply only decorativewall light white in colour made up of poly carbonate including 9 watt retrofit LED Lamp complete all as specified and directed. 37 S&F in repair building security LED lightluminaire 30 W, IP 66, IK-07, AC 230 volts, made up of pressure di-cast iron housing complete making connectionusing PVC insulated and sheathed3 core multi stranded copper conductorcable of size 0.50 Sqmm from ceiling rose including MS bracket made of 25/32mm GI pipe bent to shape, fixed to wall with clamps and nuts & bolts for mounting fittings complete all as specified and directed. 38 Supply only building security LED lightluminaire 30 W, IP 66, IK-07, AC 230 volts,made up of pressure di cast iron housing complete PVC insulated and sheathed 3 core multi stranded copper conductorcable of size 0.50 Sqmm from ceiling rose including all as specified and directed 39 Note for srl item No 32 to 37 above:- 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70.4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W.6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. Lenses shall be Modular Type. 8. PCB used shall be MC PCB type. 9. CA No. shall be written on each fitting before installation. 10. The name of manufacturer to be embossed on the fitting. 11. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.12. The defect liability period of LED lights shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over for replacement. 13. A guarantee of 05 years shall be provided by contractor supported by OEM covering all parts of luminaire. Contractor shall deposit security on this account @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/Final Bill. 40 S&F in repair sheet metal encloser,single pole and neutral 240 volt, 20 to 32 Amps with two pin and earth plug and socket plug top complete with single pole MCB complete all as specified and directed. 41 S&F in repair sheet metal encloser for DBs double door single pole and neutral with 200 amps rated bus bar of 08 way, 240 volts complete all as specified and directed. 42 S&F in repair sheet metal encloser for DBs double door single pole and neutral with 200 amps rated bus bar of 12 way, 240 volts complete all as specified and directed. 43 S&F in repair prewired VTPN Distribution board of size not less than 750mmx470mm with provision for & including MCCB as incommer 63 Amp, 04 pole IP 54, 04 way (for incomming MCCB & outgoing MCBs), with copper busbar for each phase, withNeutral bar,Earth bar and cable ties for cable managemet, fully insulated busbar & shrouded Neutral bars, with 63 Amps MCCB, 50 KA, 4 pole, as incomer and SP MCBs of capacity 16-32amps as outgoing complete all as specified and as directed. Note: Cost of MCCBs and MCB, cutting chases, grouting in wallshall be deemed included in quoted rate. 44 M&L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, FRLS PVC sheathed two run (as phase and neutral) and run 6.0Sqmm multistrand PVC sheathed copper conductor cable for earth continuity drawn in & including PVC rigid non metalic concealed conduit 20mm dia with fittings & accessories including cutting chases in walls by using electric cutter andmaking good the disturbed surface by providing cement plaster & white wash/colour wash to match complete all as specified and directed. 45 All as per description of serial item No. 42.00 here in before butin existing Conduit. 46 Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws, canopy screws of suitable size and ensuring all blades screwed properly before refixing including replacement of PVC fan box round sheet as required on site and making electric connection with flexible copper conductor of size 3 core 0.50 Sqmm complete all as specified and directed. Note :- (i) Fan shall be collected by the contractor from MES store yard at thier own arrangement.(ii) Rewinding and supply of replacedparts other than specified in this item , if any,shall be measured and paid seperately.(iii)Rates are deemed to include cost of repair / replacement of parts & servicing. 47 M&L for dismantlingmotor of ceiling fan 1400/1200 mm sweep, AC, 240 volts, any make and taking out burnt winding by cutting, cleaningslouts and re-winding ofmotor with super enameled heat resistant copper winding wire of gauge 35/36 SWG including sleeve work, varnishing with 1st class insulation, greasing, threading, connection with flexible wire 23/0.0076mm copper wire upto connector block and re-assembling and testing for 4 Hrs after repair complete all as specified and directed. Notes:-(i)Motor shall be wound with machine only and repair of ceiling fan shall be undertaken inside office complex of GE(S) Mamun.(ii) Super enameled copper winding wire of make Khaitan /RPG / KEI or equivalent shall be used. (iii) Total weight of binding wire should not be less than 200 gm per fan. Old burnt, retrieved binding wire for credit shall also be taken not less than 200 gm per fan. Contractor shall keep this aspect in mind before quoting the rate. 48 M&L for servicing of exhuast fans of capacity upto380mmincluding taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws, canopy screws of suitable size and ensuring all blades screwed properly before refixing including replacement of PVC fan box round sheet as required on site and making electric connection with flexible copper conductor of size 3 core 0.50 Sqmm complete all as specified and directed. Note : - Rewinding and supply of replaced parts other than specified in this item if any shall be measured and paid seperately. 49 All as perdescription Sr item No 46.00here in before but capacity 450mm to 750 mm. 50 M&L for dismantlingmotor of Exhaust fan 380 mm sweep, AC, 240 volts, any make and taking out burnt winding by cutting, cleaningslouts and re-winding ofmotor with super enameled heat resistant copper winding wire of gauge 35/36 SWG including sleeve work, varnishing with 1st class insulation, greasing, threading, connection with flexible wire 23/0.0076mm copper wire upto connector block and re-assembling and testing for 4 Hrs after repair complete all as specified and directed. Notes:-(i)Motor shall be wound with machine only and repair of exhaust fan shall be undertaken inside office complex of GE(S) Mamun.(ii) Super enameled copper winding wire of make Khaitan /RPG / KEI or equivalent shall be used. (iii) Total weight of binding wire should not be less than 150 gm per fan. Old burnt, retrieved binding wire for credit shall also be taken not less than 150 gm per fan. Contractor shall keep this aspect in mind before quoting the rate. 51 All as per description ofSrl item No 48 here in before but 450-750 mm sweep.Note :- Total weight of binding wire should not be less than 300 gm per fan. Old burnt, retrieved binding wire for credit shall also be taken not less than 300 gm per fan. Contractor shall keep this aspect in mind before quoting the rate. 52 Supply only gun metal bush of ceiling fan of 1200/1400 mm sweep as per existing size, complete all as specified and directed. 53 Supply only capacitor AC 440 volts, 2.5 mfd, ISI marked with copper wire terminal including PVC clamp complete all as specified and directed. 54 Supply only capacitor AC 440 volts, 3.15 mfd, ISI marked with copper wire terminal including PVC clamp complete all as specified and directed. 55 Supply only capacitor AC 440 volts, 4.5 mfd, ISI marked with copper wire terminal including PVC clamp complete all as specified and directed. 56 Supply only ball bearing suitable for ceiling fan/exhaust fan/wall/pedestal fan any type complete all as specified and directed. 57 Supply only shackle assy kit comprising of rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. 58 Supply only ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.00mm suitable for 1400/1200mm sweep ceiling fan of any make complete all as specified and directed. 59 Supply only down rod for ceiling fan made of MS pipe medium grade 15 mm bore,45 to 60 long as required at site, duly drilled holes at both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and spray painted complete all as specified and directed. 60 Supply only superior quality PVC canopy top & bottom of ceiling fan as per existing size & shape complete all as specified and directed. 61 Supply onlymetallic casing set (upper and lower ) for housing ceiling fan motor of size required at site for ceiling fan 1200mm/1400mm sweeppowder coated complete all as specified and directed. 62 Supply onlymetallic exhuast fan/wall mounted fan blade duly powder coated of type, make and colour as of existing exhaust fan, wall mounted fan, suitable for size upto 380mm sweep complete all as specified and directed. 63 All as per description of Srl item No 60 here-in-above butfor size 450mm to 750mmsweep. 64 S&F in repairs cable PVC insulated and overall sheathed with flexible copper conductor 3 core of size 0.5 sqmm complete all as specified and directed. 65 M&L for removing old paint ofceiling fan 1200-1400mm sweepby scraping with sand paper including washing and filling cavaties with filler and applying two coats of heat resistant high quality synthetic enamel paint at workshop by spray painting incl, writing MES No on the ceiling fans as directed. Note:- Paint qaulity and colour shall be get approved by GE. 66 M&L for removing old paintof exhaust fan upto 380mm sweep by scraping with sand paper including washing and filling cavaties with filler and applying two coats of heat resistant high quality synthetic enamel paint at workshop by spray painting incl, writing MES No on the exhaust fans as directed. Note:- Paint qaulity and colour shall be get approved by GE. 67 All as per Sr Item No 64 here in beforebut 450mm to 750 mm sweep exhaust fan. 68 S&F in repairsGI shutter and louvers of exhaust fan upto380 mm sweep as per existing size & shape duly spray painted complete all as specified and directed. 69 All as per Sr Item No 66 here in beforebut 450mm to 750 mm sweep. 70 S&F in repairs PVC fan blade set of suitable size as per existing make and size of exhaust fan upto 300mm sweep, complete all as specified and directed. 71 M&L for lathe work of ceiling fan / exhaust fan of any capacity and make,includingre-alignment to rotor, stater sloter, cleaning welding , bracing and polishing etc and refixing after repair and testing complete all as specified and directed. 72 Supply onlyPVC body of exhaust fan alongwith shutter cover plate of size upto 300mm sweep including all fitments such as screws, gasket cover, canopy of both sides etc complete all as specified and directed. 73 Supply only motor of exhaust fan upto380mm sweep metallic body 230 Volts 50Hz 900RPM (ISI Marked) with copper winding complete all as specified and directed. 74 Supply only motor of exhaust fan from450mm to 750 mm sweep metallic body 230 Volts 50Hz 900RPM (ISI Marked) with copper winding complete all as specified and directed. 75 Supply only outer metallic body of exhuast fan alongwith connected support arm and body frame of size upto 380 mm sweep including all fitments such as screws, gasket cover canopy of both side etc complete all as specified and directed. 76 Supply only outer metallic body of exhuast fan alongwith connected support arm and body frame of size upto 450 mm to750mm sweep including all fitments such as screws, gasket cover canopy of both side etc complete all as specified and directed. 77 M&L for repair & servicing of geysers 50/25 ltr capacity,storage type, by taking down carefully from wall after unscrewing nut/boltsand taking out internal tank, syphon assembly etc, strip opening replacement ofunservicableparts such as water storage tank, syphon assembly, heating element, thermostat etc including descaling of serviceable water stoarage tank and re-assembling and re-fixing in position and testing complete all as specified and directed.Note:Replaced parts / componants shall be measured and paid for separately under the respective item here-in-after. 78 Supply only water tank of geyser 50 ltr capacityinternal glass lined/enameled/ titanium coated,SS 304 steel with 0.7/0.8 Mpa bar pressure conforming to IS as per site requirement of complete all as specified and directed. Note:- (i) The tank shall be tested at site and shall be able to withstand requisite pressure.(ii) Necessary testing equipment shall be arranged by the contractor. (iii) Tank with stud type roundelement shall only be used . Triangular element shall not be accepted 79 Supply only water tank of geyser 25 ltr capacityinternal glass lined/enameled/ titanium coated,SS 304 steel with 0.7/0.8 Mpa bar pressure conforming to IS as per site requirement of complete all as specified and directed. Note:- (i) The tank shall be tested at site and shall be able to withstand requisite pressure.(ii) Necessary testing equipment shall be arranged by the contractor. (iii) Tank with stud type roundelement shall only be used . Triangular element shall not be accepted 80 Supply only brasssyphon assembly of 6 holes / 09 holes as per site requirement for 50 ltr capacity Geyser (ISI marked) including necessary studs screws and rubber gasket/washers complete all as specified and directed. 81 All as per description of Srl item No. 78.00 here in before,but for 25/35 ltr capacity Geyser. 82 Supply only ofthermostat switch (ISI marked) suitable for geyser 25 ltr to 50 ltr, AC 230 volt adjustable range from 0-90 degree celsius as per exisiting size, make and shape complete all as specified and directed. 83 Supply only heating element titanium coated of rating 1.5/2 KW suitable for geyser any type and make as per existing and site requirement including gasket washer (ISI marked)geyser element AC 230 volt complete all as specified and directed. 84 Supply only heating element square/ oval/ round shaped titanium coated of rating 1.5/2 KW special type suitable for existing geyser any type and make as per existing and site requirement incl gasket washer (ISI marked) geyser element AC 230 volt complete all as specified and directed. 85 Supply only heating element, titanium coated of rating 1.5 KW suitable for water heater storage type combination with syphon assy and thermostat complete (Round / Oval / Square type as directed) for 5 star rated geyser as per sample with existing one) of any make and description as required at site including rubber washers (ISI Marked) complete all as specified and directed. 86 Supply onlyouter body suitable for 50 ltr geyser with rust proof made out of CRCA sheet (16 gauge) 1.5 mm thick electro statically powder coated stove enamelled factory made complete with fixing bracket matching with existingand nuts and bolts to fixed to wall complete all as specified and directed. 87 Supply onlyouter body suitable for 25 ltr geyser with rust proof made out of CRCA sheet (16 gauge) 1.5 mm thick electro statically powder coated stove enamelled factory made complete with fixing bracket matching with existingand nuts and bolts to fixed to wall complete all as specified and directed. 88 S&F in repairindicator lamp (green and red ) superior quality with neon lamps (ISI marked ) indicating automatic working of geyser round/square type as per existing andsuitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as spd and directed. 89 S&F in repair cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 2.5 sqmm (ISI marked ) 1100 volts grade complete all as specified and directed. 90 Supply & fixing geyser connection pipes for hot & cold water supply made out of stainless steel wire braided connector with crome finish heavy duty nuts of 15 mm dia size with suitable length and as per existing site conditioncomplete all as specified and directed. 91 Supply & fixinganchor bolt 12mmX100mm long complete all as specified and directed.(Note:- Anchor bolt shall be grouted with hammer drill only) 92 M & L for preparing the old painted steel surface of geyser 50ltrscapacity by rubbing/scratching the old paint and painting with the two coats of synthetic enameled paint whitewith spray gun including writingMES No with black paint of required size and shape complete. 93 All as per description of Srl item No. 90.00 here in beforebut 25 ltr capacity. 94 S&F in repair top / bottom cover plate along with screws for outer bodyof geyser 25-50 ltrs capacity complete all as specified and as directed. 95 Supply onlysafety valve (ISI marked ) suitable for 25 ltr to 50 Ltr geyser capacity as per site requirement and shape and size complete with all as specified and directed 96 Supply onlyspring loaded air release valve (ISI marked) suitable for 25 ltr to 50 Ltr geyser capacity as per site requirement shape and size complete with all as specified and directed 97 S&F in repair fusible plug(ISI marked ) suitable for 25 to 50 Ltr geyser capacity as per site requirement (shape and size) complete with all as specified and directed 98 S&F in repair non return valve(ISI marked) suitable for 25 ltr to 50 Ltr geyser capacity made out of brass for bore dia of pipe 15 mm dia andas per site requirement and shape nd size complete with all as specified and directed 99 Supply onlyhigh density PUFinsulation material non hygroscopic, fire resistant,suitable for 25 to 50 ltr cap geysercomplete complete all as specified and directed.