}

Tender For Improvement Modernization Of Infrastructure In F V Market Kathua Bwo Construction Of Hall ( Under Capex Budget 2025 26), kathua-Jammu And Kashmir

Public Works Department has published Tender For Improvement Modernization Of Infrastructure In F V Market Kathua Bwo Construction Of Hall ( Under Capex Budget 2025 26). Submission Date for this Tender is 10-09-2025. Building Work Tenders in kathua Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50950980
Tender For Improvement Modernization Of Infrastructure In F V Market Kathua Bwo Construction Of Hall ( Under Capex Budget 2025 26)
Tender
Indian
Jammu And Kashmir
Kathua
10-09-2025

Tender Details

Tender For Improvement Modernization Of Infrastructure In F V Market Kathua Bwo Construction Of Hall ( Under Capex Budget 2025 26)- 1 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable materialin cement mortar, all leads & lifts. 2 DemolishingRCC work manually /by mechanical means including stackingofsteel bars anddisposal of unserviceable material ,all leads & lifts. 3 Earth work in excavation in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and the like not exceeding 10sqm on plan, depth upto 1.5mtr.including disposal of excavated earth incl. all leads andlifts. 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, incl. all leads and lifts 5 Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber,grades and cross sections. Finished work including materialand labour incl. all leads, lifts & carriage of material by MT / H.L. 6 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) . 7 Providing and laying in position cement concrete of specified grade incl.curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) . 8 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) . 9 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1.5:3 (1 cement : 1.5coarse sand :3graded stone agg. 20 mm nominal size). 10 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½::3 (1 cement : 1½ coarse sand :3graded stone agg. 20 mm nominal size) . 11 Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). 12 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level TheMetreo-Mechanically Treated bars of grade Fe-500D or more. 13 Centring and shuttering including strutting propping etc and removal of form work for 14 Foundations, footings, bases of columns etc. for mass concrete. 15 Suspended floors, roofs, landings, balconies and access platfoMetres. 16 Edges of slabs and breaks in floors and walls under 20 cm wide 17 Columns, pillars, piers, abutments, posts and struts. 18 Arches, domes, vaults upto 6 m span 19 Lintel, beams, plinth beams, girders, bressumers and cantilevers. 20 Brick work with F.P.S. bricks of class designation 75in foundation and plinth. in cement mortar 1:6 ( 1 cement : 6 coarse sand). 21 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. 22 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand). 23 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 24 12mm cement plaster of mix 1 : 4 ( 1 cement : 4fine sand) 25 15mm Cement plaster on the rough side of single or half brick wall of mix 1: 6 ( 1 cement : 6 coarse sand) 26 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 27 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. 28 Providing gola 75 x 75 mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 10mm down gauge) incl. finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75 x 75 mm deep chase. 29 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 30 Providing and fixing 16 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour or shade(Area of slab upto 0.5 sqm) 31 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work 32 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick top cover 33 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete 34 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets. 25mm dia (heavy type). 35 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cementconcrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). 36 Providing and fixing aluminum work for doors, windows ventilators and partitions with extruded built up standard tubular sections/appropriateZ. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with dash fastener of required dia and size including necessary filling up of gaps at junctions i.e. at top, bottom and sides with required EPDMrubber/neoprene gasketfelt etc.Aluminum sections shall be smooth, rust free, straight, milted and jointed mechanically wherever required includingcleat angle, Aluminum snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge( glazing, paneling and dash fasteners to be paid for separately.) For fixed portion Powder coated aluminum ( minimum thickness of powder coated 50 microns) 37 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) 38 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Sal wood 39 Providing and fixing 35mm thick glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class deodar wood 40 Providing and fixing 35mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second class deodar wood 41 Providing and fixing panelling orpanelling and glazing inpanelledorpanelledandglazedshuttersfordoors, windows and clerestory windows (Area of openingfor panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick , Particle Board 12 mm thick plain particle board flat pressed, three layer or graded wood particle board medium density grade IS: 3087 marked. 42 Providing and fixing 35mm wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :Second class deodar wood 43 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer -in-charge. (Cost of aluminum snap beading shall be paid in basic item.)With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) 44 Providing and laying vitrified floor tiles in size of tile 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% & conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) incl. routing the joints with white cement and matching pigments etc. complete 45 Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 46 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 47 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 48 Providing and fixing uplasticized PVC connection pipe with brass unions 30 cm length15 mm nominal bore 49 Providing and fixing P.V.C. waste pipe for sink or wash basin incl. P.V.C waste fittings complete: Semi rigid pipe 32 mm dia 50 Providing and fixing Stainless Steel A ISI304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board610x510mm bowl depth 200mm 51 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes 52 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.20mm nominal outer dia pipes. 53 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 54 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 55 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mmdiametre 56 Providing and fixing on wall face un-plasticized - PVC moulded fittings /accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion.Bend 87.5°110 mm bend 57 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm 58 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm 59 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm 60 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm 61 Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 62 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm 63 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick 64 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 65 Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work 66 Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 67 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood) havingVOC content less than 50 grams/ liter 68 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work 69 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-15 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge 70 Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer- in-charge.With average thickness of 120mm and minimum thickness at khurra as 65 mm 71 Disposal of malba within an avg. lead of 3 Kms 72 Carriage of sand by mechanical transport incl. loading/unloading within a lead of 10 kms 73 Carriage of stone aggregatebelow 40 mm by mechanical transport incl. loading /unloading within a lead of 10 kms 74 Carriage of Bricks by avg lead of 10 Kms.Incl. loading/unloading complete 75 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. 76 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 77 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 78 2 X 2.5sq. mm + 1 X 2.5 sq.mmearth wire 79 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 80 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 81 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 82 2 X 16.0sq. mm + 1 X 6.0 sq.mm earth wire 83 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 84 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 85 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 86 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 87 Bell push 88 5/6 Amp switch 89 3 pin 5/6 Amp Socket outlet 90 15/16 Amp Switch 91 6 pin15/16 Amp Socket outlet 92 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm) 93 Supplying & fixing of Electrical Accessories 94 4 Deep Box 95 5 Fan Box 96 Ceiling Rose 97 Fan sheet 98 Round sheet 99 Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan.2-0 100 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). 101 25 mm 102 32 mm 103 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. 104 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 105 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 106 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB /Isolator) 107 8 way , Double door 108 16 way , Double door 109 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator) 110 4 way (4 + 18), Double door 111 6 way (4 + 24), Double door 112 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 113 Single Pole 114 Single pole & neutral 115 Triple pole & neutral 116 Supplying and fixing following rating and poles230/ 415 V, 10 KA, C curve M.C.Bs in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 117 Single pole & neutral 63 Amp 118 Triple pole & neutral 63 Amp 119 Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required. 120 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 121 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 122 Supply installation testing and commissioning of IP:20 AluminiumBatten 20W-22 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The inputvoltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. 123 Supply installation testing and commissioning of IP20 led downlighter 15 W-18 W +/- 1 WLED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. 124 Supply installation testing and commissioning of BLDCCeiling Fan 1200 mm 230V 28 W with Speed RPM 350 with miimum Air delivery 220 CMM including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 125 Mirror light LED fitting with 9/11W LED lamp 126 Supplying,Installation,Testing and Commissioning of Cubical Type Indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)Main L.TPanel .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagrambefore start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall beCPRI /ERDA/ANY NABL ACCREDITED LAB approved.( Total 03 nos. panels required (1) 18 cft for Main LT panel outdoor type (2) 6 cft for Sub Distribution panel Library premises (3) 6 cft for Sub Dustribution Panel Auditorioum) 127 MCCB 320 A F.P 36 Kawith Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%(For Incomer main supply of Main LT Panel) 128 MCCB 200 A F.P 36 Kawith Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%(01 no for Incomer of DG Supply of Main LT panel and 01 for ootgoing to changeove of main LT panel) 129 MCCB 100 A F.P 30 Kawith Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%(05 for outgoing of Main LT Panel in which 03 are spares, 01 no for Mini Auditorium Sub panel& 01 no for LibrarySub Panel) 130 Onload change over Switch FP 200 Amp(Front operated)( In Main LT Panel) 131 Onload change over Switch FP 100 Amp(Front operated)(01 no inLibrary Sub Panel & 01 no in Auditorium Sub panel) 132 Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch, Indicating Lamps,C.T Set etc(02 in Main LT panel & 01 in Mini Auditorium Sub Panel,01 in Library Sub Panel) 133 Aluminium Bus Bar 500 Ampset of 4 strips(Main LT Panel 134 Aluminium Bus Bar 300 Amp set of 4 strips(Main LT Panel) 135 Aluminium Bus Bar 200 Amp set of 4 strips(Sub Panel) 136 Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required . 120 mm dia (OD-120 mm & ID-103 mm nominal) 137 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 138 10 sq. mm 2 core 139 50 sq. mm 3.5 core 140 95 sq. mm 3.5 core 141 300 sq. mm 3.5 core 142 Providing and Fixing LED Lamp 9 W

Key Value

Document Fees
INR 1500 /-
EMD
INR 115860.0 /-
Tender Value
INR 57.93 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail