| 1 | Civil work: |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (CSI 15.2.2) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.(CSI 2.6.1) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources(CSI 4.1.8) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)(CSI 5.1.2) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars(CS I5.22.1) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, of:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)excluding cost of centering, shuttering, finishing and reinforcement (CSI5.2.2) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand( CSI6.1.2) |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI10.2) |
| 10 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.(CSI 14.1) |
| 11 | 12 mm cement plaster of mix :1:4 (1 cement: 4 course sand)finished with a floating coat of neat cement of mixenternal & external plaster are for height upto 10m from ground level in less otherwise stated.(CSI13.7.2) |
| 12 | Painting twocoat with APEX or equivalent brand weather coat paint on previously treated surface ) including through washing with water including cost of all materials, labour, T&P required for proper completion of work. (CSI No. 13.23+24) |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.(CSI 13.88) |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(CSI4.1.2) |
| 15 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(CSI 12.5) |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (CSI13.62.1) |
| 17 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.(CSI15.60) |
| 18 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit concealed in wall, GP Box, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD131-C) |
| 19 | Wiring point for plug with 1 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit conceled in wall with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit on surface, piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD134-C) |
| 20 | Wiring point for fan /fresh air fan (light duty exhaust fan)with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cablein PVC conduit conceled in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect as per direction of E/I. (PWD123-C) |
| 21 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. (PWD1139) |
| 22 | Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia PVC conduit on surface, with one number 2.5 sq. mm. multistrand copper drawn in conduit complete in all respect. (PWD216-C) |
| 23 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.(CSI29.135) |
| 24 | Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(OLD CSI No. 28.39) |
| 25 | S/R of regulator for ceiling fan of GEC or equivalent make including cost of all labour material, T&P etc. required for proper completion of the work. ( CSI22.60b) |
| 26 | S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve. (PWD C.S.I. No. 1002-B) |
| 27 | Supply and fixing of LED street light fitting having dia cast aluminum body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 production complete in all respect. (PWD1424) |