Tender For Addn/Altn To Airmen Mess At Af Stn Bikaner; 1 Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for completeall as specified and directed 2 Demolition of mud in roofs, any thickness including plastering & leaping (wheather full or part)removal of debris at a distance exc 250m but not exc 500m and deposited where directed 3 Materialand labourfor providingcementconcrete PCC (1:2:4) type B1 (20mm graded crushed stone aggregate)as in roofpaddingcompleteall as specified and directed 4 M&LforAPPbasedmodifiedpre fabricatedfivelayer3 mm thick andweighingnotlessthan3.0 Kg/Sqmwater proofing membrane reinforcedwithpolyesternon wovenfabricmatwith150 gm/Sqm blackfinishedwith compatibleprimerconformingto IS 3488 @ 0.30 Lit/ Sqm andbonding material85/25bitumen1.2 Kg/Sqmbefore layingmembranelaidbytorchapplicationsideoverlapof 75 mm andoverlapof 100 mm longtitudinally, At thejunctionof roof andparapet walla groveof 20 x 20mmshall be madeatthehtof100 mmandmembrane shall be inserted andsealedwithbituminious masticjoints/overlap shallve saledwithhotbitumen85/25all as directedby Engineer -in- charge. 5 Supply only integral water proofing compound ISI marked.all as directedby Engineer -in- charge. 6 Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of grooves with cement mortar 1:3 all as directedby Engineer -in- charge. 7 M&L for 15 mm thick plaster in CM(1:4) over concrete surfaces of roofs finished even and smooth using extra cement with WPC @ 3% by weight of cement, complete all as specified and as directed.Note:WPC will be measured and paid seperately. 8 M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and no pigments in floors, and cut and polished including 15mm thick screed bed in CM(1:6) ,complete all as specified . 9 M&L for Providing cement concrete 1:2:4 type B0 (12.5 mm graded crushed stone aggregate ) in roof kerbs or mud stops, rounded or chamfered on edges complete all as spd 10 Demolition of reinforced cement Concreteof any description and in any position not otherwise specifically provided for completeall as specified and directed 11 M&L mild steel TMT Bars 10mm dia andover cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip) complete all as specified and directed. 12 M&Lfor RCC type B01;2:4( 12.5 mm gradedcrushed stoneaggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and including form work complete all as specified & directed. Note : reinforcement shall be measeured and paid seperatly. 13 M&Lforbrickwork with sub classBbrickold size burnt clay straightor curvedonplan exc6 m mean radiusand builtin cement mortar (1:6), complete all as specified and as directed. 14 Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified & directed. 15 M & Lfor machine cut Granite slab 15 mm thick fixedfor steps, pillars,window cills, cooking plateforms and like and incl 10mm thick (avg thickness) cement mortar 1:4 screeding and setting coat in cement morter 1:2, 3mm thick, set and jointed with white/coloured cement to match the shade of slab incl cutting, waste, rubbing and polshingetc complete all as spd.Note:- (i) The rate of granite stone shall be deemed to incl for full rounded off corner/edges incl all cutting to make it square or rectangular. (ii) The rate shall also be deemed to incl for cutting and polishing machine and granite polishing to achive the desired granite finish all as spfd. 16 Supply& fixingas in repair vitreous china wash hand basin, white flat back, size 300mm x 450mm including pillar tap 15mm diachromium plated with capstan head with long screwed shanks and fly nuts, and including brass, chromium plated,waste coupling 32mm dia, complete all as specified & directed. 17 Supply and Fixed-in-repair, sinks with drainage board made of stainless steel 1 mm thick, kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x160mm, complete all as specified and directed. 18 S&F 40mm bore dia of discharge pipeBottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260gms/40mm-270gms) complete as specified and directed 19 Dismantling water tanks and removing from site of anycapacity complete all as specified and directed. 20 S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top having screwd down LID cover)tripple layerhoisted and fixed in position, complete all as specified and directed 21 S&F 1000 ltr Rotational moulded polythlyene water storage tanks tripple layer (cylindrical vertical having screwd down LID cover) with close top hoisted and fixed in position, complete all as specified and as directed. 22 Supply and fixing in repairs, fancy type angle stop valve, brass, chromium plated,screwed down, high pressure with quarter turn, screwed for iron pipe or for union, suitable for 15mm bore pipe,complete all as specified and directed. 23 Supply and fixingin repairs long body Bib taps,chromium plated cast copper alloy with quarter turn, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe complete all as specified and directed. 24 M & L for Cutting chases, pining in making good to facings where required & pointing in cement mortar1:3 to ends etc or edges of landings, steps cills,sunshades, shelves,lintels,etc and cutting chases for concealed water tubing and making good,cutting n.exc. 10cm girth in brick walls all asdirected. 25 Taking up or down 15 mm dia steel tubing and connectionand removal from site complete all as specified and directed. 26 Taking up or down 20 mm dia steel tubing and connectionand removal from site complete all as specified and directed. 27 Supply and fixing 15mm bore tubes medium grade galvanized with and incl all fittings complete to walls and ceiling with necessary clamps or laid in floors complete all as specified & directed. 28 Supply and fixing 20mm bore tubes medium grade galvanized with and incl all fittings complete to walls and ceiling with necessary clamps or laid in floors complete all as spd & directed. 29 Supply& fixingPVC connections 15mm size with PTMT nuts of length 450 mmcomplete all as specified anddirected. 30 Supply and fixing as in repair vitreous china squatting pan Orissa pattern size 580 x 440mm, white, with integral footrest (excluding flushing cistern) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor, set with cement concrete,complete all as specified and directed. 31 Supply and fixing as in repair PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC bend for required squat pattern etc, set with concrete and making good to floor, complete all as specified & directed. 32 S&Fas in repairs Chromium plated shower roses 125 mm size fixed with swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. 33 S&F as in repairs 100 mm dia mild steel chromium plated grating with or without waste pipe hole as per requirementcomplete all as specified and directed. 34 S&F in repair tubular towel Rail 600 mm length and20 mm dia of brass chromium plated complete all as specified and directed. 35 S&F in repair stailess steel curtain road 30mm dia of brass chromium plated incl necessary fixing brackets and ornamental fittings , complete all as specified and as directed. 36 S&F in repair soap dish chromiume plated,any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed. 37 Taking down shutters of any description exc 1 sqm but n.exc 2 sqm from chowkhat and removing to or from store as required, complete all as specified. 38 Supplying & fixing in opening solid PVC door frame of size 50mm x 47mm made out 5mm plain colour PVC sheets re-inforced with MS tube Square tube in opening complete all as specified & directed 39 M&L factory made solid panel pvc door shutter 30mm thickconsisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottam rail . paneling of plain colour PVC sheets to be filted in MSframe welded, sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with the solvent cement complete all as spd. 40 S & F 40mm dia cupboard fancy handle fixed with nut screw and washer of mild steel bright finished 41 S & F 40mm width of flaps continuous (piano) hinges mild steel bright finish or electrogalvanised. 42 S&F anodised aluminiumpowder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified 43 S&F anodised aluminiumPowder coatingwindow and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m (with style and rail of size 47.62 x 44.45 x 1.67mm)including necessary joining cleats, glazing clips, ruber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle(1 no) including all necessary builders hardare complete all as specified. 44 Taking down chowkhats with shutter without taking off shutters from the frames (area exc. 1.50 sqm but n. exc. 4.00 sqm each) incl making good the disturbed surfaces complete all as specified & directed. 45 Material & Labour for pressed steel frames with 1.25 mm thick sheet for doors of size 125 x 60 mm for doors with one or more rebate incl necessary fixing lugs, hinges, lock, strike plates of 50 x 3mmwelded with frame and making arrangement for fixing of door spring etc.complete all as specified. 46 Supply and fixing plain, framed, Plain framed, panelled shutter (two panel) 35 mm thick of 2nd class hardwood rail and stylewith lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one coat of pink primer complete all as specified & directed. 47 Supply and fixing glazed and gauged skeleton shutters35mm thick, 2nd class hard wood Hollockopen rebated and prepared to receive glass, gauge etc (with sash bars) edges of framing plain chamfered or rounded fitted with cutand mitred beads for securing glass etcincl priming coat. The size of member of shutters as spfd in SSR Part-1 Section 8 clause 8.24 (a) incl kiln seasoned and chemically pressure treated, complete all as specified & directed. 48 Material & Labour barrel tower bolts aluminium anodised extruded section of size 200 mm complete all as specified & directed. 49 Supply and fixing aluminium fabricated type extruded handles of size 150mm complete all as specified & directed. 50 S&F as in repairs of 300mm mild steel ordinary rat tail rod pattern door spring incl roller and roller plate complete all as spfd. 51 Supply and fixing 300 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing cleap of sheet, cast or extruded sections, bolt not less then 12mm dia with and including a minimum of 6 bolt and nuts ,fixed on plate or staple plate complete all as specified & directed. 52 Supply and fixing Galvanised mild steel wire cloth, in new doors and windows 0.56mmnominal dia of wire and avrg widh of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified & directed. 53 Supply and fixing in repairs, Galvanised mild steel wire cloth, 0.56mmnominal dia of wire and avrg widh of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified & directed. 54 Hacking out old broken glass (any th size, quality or description) from wooden or steel frames glazed with putty or fixed with wooden beads complete all as directed. 55 S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or with clip in squares n.ex.c. 0.50sqm in each pane complete 56 All as per Item No. 56 above but 4mm thick ordinary sheet glass exc 0.5sqm in each pane. 57 Materialand Labour for preparation of newsurfaces of wood & wood based surfaceof any description not otherwise described, over 10 cm width & girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and directed by Engineer-in-Charge. 58 Materialand Labourfor preparation of newsteel & steel based surfaceof any description not otherwise described, over 10 cm width & girth and applying twocoat of synthetic enamel paint over and including a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. 59 M&L preparation of old painted steel surfacesof any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) incl for angle iron,fencing post,Rolling shutter etc,complete all as specified & directed. 60 M&L preparation of old paintedwood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified & directed. 61 Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removal complete all as specified and directed. 62 M&L for non skid ceramic coloured tiles 7-8 mm thick, (square/rectangular) area of each tile exc. 0.11 but n.exc. 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM 1:6, complete all as specified and as directed. 63 M & L for joint free glazed coloured ceramic coloured tiles of 300mm x 450mm x 7mm thick on vertical surface of walls set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles, over and including 10mm thick rendering in CM 1:4, all as specified and directed by engr-in charge. 64 M & L for 50 mm thick cement concrete type C-2 1:2:4 (20mm graded crushed stone aggregate) as in sub-base for tilingor similar works, complete all as specified and as directed. 65 M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick screed bed in CM(1:6) laid and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete all as specified & directed 66 Taking down cement plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed. 67 M&L rendering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. 68 Material and labourrendering 15 mm in cement mortar 1:6 on fair faces of brickor concrete surfaces and finishing the surfaceseven and smooth without using extra cement complete all as specified and directed. 69 M&L rendering 5 mm in cement mortar 1:3 on fair faces of brick /concrete surface of ceilling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. 70 M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed. 71 M&L preparation of newly plastered surfaces of walls including all cornices, pilasters etc and applying two coats of acrylic exterior emulsion paint in camouflage pattern of approved tint / shade(s) over and including a coat ofwater based primer, complete all as specified and directed. 72 M&L preparation of newly plastered surfaces of ceilling / chajja or similar suspended work and applyingtwo coats of white wash complete all as specified and directed. 73 M&L for gunniting work to RCC work in column, flooring, side walls, beam, slab, etc by carefully chipping , removing existing loose/damaged concrete cover etc, and cleaning all exhisting reinforcement bars with wire brush and applying alkaline rust converter primer on exhisting rebars and allowing it to react with rust for 06 hrs and form corrision resistant layer , then applying zinc rich anti-corrosive protective coating on reinforcement bars as per manufacture instructions , and fixing welded wire mesh fabric size 50X50 mm with 3mm dia , and plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 25 mm and making the surface even including 15mm thick plastering in CM 1:4 onconcrete surfaces , finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out complete all as specified and directed.Note.- Where ever reinforcement/MS steel required will be measuredseparately. 74 Supply & fixing hard drawn MS steel wiremesh 80mm x 25mm with 3mm dia wire with Heavy duty nails, Fixing the mesh on the ceiling before gunniting work. 75 Materail and Labour for preparation of plastered or unplastered old surfaces of ceilingand one coat of white wash on ceiling all as specified and as directed by Engr-in-Charge. 76 M&L for3mm thick wall care putty on wall complete all spd and directed 77 M&L for3mm thick wall care putty on ceiling complete all spd and directed 78 Materail and Labour for Complete removal of existingplastered or unplastered old surfaces of walls and applying two coats of oil bound distemper on walls over and including a coat ofalkali resistant priming paint primer,all as specified and as directed by Engr-in-Charge. 79 Demolition of plain cement concrete in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified & directed. 80 Material & Labour for 75mm thick cement concrete type D-2,1:4:8 (40mm graded crushedstone aggt) as in sub base concrete all as specified & directed. 81 M&L PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in plinth protection 75mm thick laid in baysand surfaces finished even & smooth without using extra cement complete all as specified . 82 Takingdownrain water pipes PVC/AC (anysizeor pattern)includingall fitting heads, shoes, bendsswan -necks etc comlete all as sd and directed by EngrinCharge 83 S&F110mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall including clamps as required, complete all as specified. 84 S&F as 110mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified. 85 S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required, fixedcomplete all as specified. 86 S&F 75mm dia PVC (SWR) vent cowl, single, equal or un equal of any length including jointing with solvant cement as required complete all as specified. 87 S&F 75mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified. 88 Material & Labour Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified. 89 M&L for steel work in tubular pipes as in vertical surfaces including special shaped washer such as column complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified 90 M&L for rolled section as in main and cross beam , hip and jack rafters; purlins where connected to common rafters and running rails andm guides for sliding doors fixed with angle cleats or other connecting plates in Fe 290 Gde E-165 complete all as specified 91 M&L Mild steel screw bolt (machine made) dia 11 to 15 mmwith hexagonal or square head at one end and screwed the other or screewd both ends each screwed end to be fitted with washers and one hexagonal nut length of bolt exc 5 cm but n. exc 10 cm long complete all as specified 92 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 93 Dewatering of septic tank/Soakage well, any size any depth, cleaning and taking out effluent water from septic tank by mechanical means as in foul conditions and confined places, filled in closed containers of capacity 5000 Litre each to the full capacity and disposed offat dumping site outside MoD, authorised by Local Administration complete all as specified and directed.Note: Record of disposal of effluent water shall be maintained by the contractor in a pucca bound register. Entry for each trip disposing off the effluent water in container with tractor RC Number carrying the container shall be made in the register and each shall be signed by the Engineer-in-Charge. 94 Desilting of manhole complete by removing all scum, sludge, silt (both organic and inorganic nature) by manual labournor mechanical scraper and disposal of the same and buried in trenches etc, as in foul condition for any depth complete all as specified and directed.Note: Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of deqatering as required and nothing extra shall be admissible to te contractor on this account.(Sludge/ sludge water shall be diposed off in closed container authorized dumping site delared by local administration outside MD land as directed by Engineer-in-charge. 95 Excavation in soft/loose soilin trenches not exceeding 1.5 metrewide / manholes area n exc 10sqm on plan and depth not exceeding 1.5 metreand getting outcomplete all as specified and directed. 96 Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. 97 Removing excavated material to a distance exc. 50 metrebut not exceeding 100 metreand depositing where directed at a level not exceeding 1.5 Metreabove starting point, complete all as specified and directed. 98 Demolition and breaking up drain pipes of150mm dia (Salt glazed ware, AC or Reinforced concrete) set incement mortar complete all as specified and directed. 99 S&F 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed as specified and directed by Engr-in-Charge. 100 M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate concrete bedding to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed 101 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra ement, including forms, moulds, mi- tred/stopped ends etc. 102 M&L factory made precast reinforced cement concrete 1:2:4, or higheras in cover slab of manholes, Drain etc, set in cement mortar 1:4 complete all as specified and directed. 103 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm bore pipes, complete all as specified and directed. 104 M&L for PCC 1:2:4 12.50 mm graded crushed stone aggrgate as in filling of pressed steel hollow frame door chowkhat complete all as specified and directed. 105 S&F sinks without drainage board of stainless made steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed 106 Dismantling of plane or corrugated galvalum, steel sheeting, any gauge, thickness including Nainital or similar pattern roof covring. 107 S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. as specified & Directed 108 M&Lfor Complete removalofexisting/oldtreatmentbymannualy and mechnically andpreparation ofsurfacesusingnecessaryfillingcompound of puttyto obtainsmoothregular/evenfinishusingsandpaperandapplyingtwocoatsofexterior emulsion paint(tint as approved by GE ) over and including a coat of primer, on wall height upto7.50 mt.completeall as specified and directedbyEngineer - in- charge. 109 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc all as specified.Note : Credit for above items should be made as per conditions separately. 110 Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. 111 M & L forPoint wiring complete with 1.5 Sq mm copper conductor single core FRLSH PVC insulated unsheathed 1100 V grade multistranded cable drawn in and including non metallic PVC rigid concealed conduit( not less than 20 mm dia) concealed in wall, ceiling with all accessories such as bends, reducer, spacers, junction boxes, pressed steel terminal boxes MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface , covered with 3 mm thick laminated sheet for mounting switch,sockets, fan regulator etc, including one running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly, complete all as specified and as directed. 112 (a) One light point controlled by one, one way switch 6 A, SP 113 (b)One ceiling fan/exhaust fan point controlled by one, one way switch 114 (c)One 3 point 6 Amps switch socket outlet point controlled by one switch on the same board. 115 (d)One 3 pin 6 Amps switch socket outlet point controlled by one switch on independent board. 116 Description all as per item No 111 here-in-before but using 4.0 Sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.0 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 117 S & F Switch pianotype single pole one way flush type 6 Amps capacity 230 volts. 118 S&F of Socket, two-in-one, 5 pin, 6 Amp, 230 volts, complete all as specified and directed. 119 S & Fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 6 Amps flush type complete all as specified. 120 S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universalcomplete all as specified 121 S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified. 122 S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed. 123 S&F LED lamp 9W complete all as specified and directed by the Engineer-in-Charge. 124 Supply and fixing LED lights fitting 20W, 6500K, efficacy greater than 100 lpw, decorative ultra slim square profile LeD lighting fixture with extruded polycarbonate, environmentalfriendly, energy efficient ready to use pack including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Cat Ref No LHEXACP7in1W020 of Havells or equivalent in list of makes. 125 Supply and fixing LED lights fitting 10W, 6500K, efficacy greater than 100 lpw, decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Cat Ref NoLHEXACP7IN1W010 of Havells or equivalent in list of makes. 126 S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size 127 Supply and fix stepped type electronic ceiling fan regulator AC230 Voltssuitable for 1200 / 1400 mm sweep complete all as specified. 128 Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote operated,complete all as specified and directed 129 S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed. 130 Supply and laying in repairs sub main wiring complete with 05 runs (3 nos for three phase, Neutral & Earthing ) of single core 10 sqmm FRLSHPVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including concealed rigid PVC conduit of 32mm dia ISI marked andaccessories surface fixedon wall /flooretc, complete all as specified and as directed.Note:- 05 runs of cable 01 metre ,01 run of PVC conduit shall be measured and as one unit length. 131 Supply and laying in repairs submain wiring with two single core 10 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid FRLSH PVC conduit of 32 dia, conduit fittings and accessories concealed in wall/floor with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note 1:Three runs of 10 Sqmm cable, and one run of conduit shall be measured and as one unit length. 132 Supply and laying in repairs submain wiring with two single core 4.0 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note 1: Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length. 133 Supply and fixing Vertical TPN DB double door, IP 45 protection with powder coated enclosure 08 way insulated busbar assembly suitable for fixing MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. 134 Supply and fixing sheet Metal enclosure double door type for DB’s 240 Volts Single Pole and Neutral 12 way with 200 Amps rated bus bar complete all as specified andas directed 135 Supply and fixing 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. 136 Supply and fixing MCB, TP, 63Amp, 415V 10KA C curve, complete with connection testing and commissioning. 137 Supply and fixing MCB SPN 40-63Amps , 240 volt, 10 KA,complete all as specified andas directed 138 Supply and fixing MCB single pole 6 to 32 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge. 139 Supply and fix factory made sheet metal enclosure, with socket plug top and MCB Triple pole with a three pin and earth plug and socket complete with and including one Triple pole MCB of capacity 32Amps, 415 Volts, B curve with breaking capacity 10kA etc., complete all as specified and as directed. 140 Supply and fixing Energy saving and environmental friendly long life 35W LED bldg security light having IP66 protection complete with all accessories incl three run of 1.5 Sqmm Copper conductor cable from security light to ceiling rose complete 141 Supply and fixing in repairs GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fittingincluding MS clamps , nuts & bolts of required size complete 142 M&L for Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4mm dia, by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth elelctrode to DBs/main switchincl provn of concrete pit in PCC , GI pipelight grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoalwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed. 143 Supply and fixing Air cooled split unit air conditioner (Indoor & Outdoor) electric driven single phase of capacity of 2 TR, BEE 5 star rated, Inverter AC, Copper, Convertible 5 in 1 Cooling, Multi Sensors, Dust Filter Blue Fins, Self Diagnosis, all as specified and directed by Engr-in-charge. 144 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. 145 Supply, install,commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (ovenbaked) with MS CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level fordoor openingsize 40x78 all as specified. 146 Supply and laying in replacement under-ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 70 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and as directed. 147 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed 148 Removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the straight point 149 Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil. 150 Material andlabour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. 151 Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.