Tender For Provision Of Maintenance Gate With Guard Room Living Accn And Connected Services At Sigar Mil Stn; 1 SCH A PART-I : BUILDING/STRUCTURESNote: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 2 Design and Construction of Guard rest room with sanitary annex with permanentstructure as mentioned in Architectural drawings and connected accessories, complete all as specified including excavation and earth work, foundation as perdesign, etc., complete with permanent specifications all as shown on Arch drawings and as specified and directed. 3 Design and Construction of Security Office with permanent structure as mentioned in Architectural drawings and connected accessories, complete all as specified including excavation and earth work, foundation as perdesign, etc., complete with permanent specifications all as shown on Arch drawings and as specified and directed. 4 Design and Construction of Escort Waiting room with permanentstructure as mentioned in Architectural drawings and connected accessories, complete all as specified including excavation and earth work, foundation as perdesign, etc., complete with permanent specifications all as shown on Arch drawings and as specified and directed. 5 NOTE: Schedule ‘A’ Part IIto X items have been Prepriced by MES and the Bidders shall insert their lumpsum cost in green field under Column-6 only. 6 Total amount of Sch A Part-II (Site Clearance) 7 Total amount of Sch A Part-III (Internal Water Supply) 8 Total amount of Sch A Part-IV (Internal Electrification) 9 Total amount of Sch A Part-V (Road, Path and Culvert) 10 Total amount of Sch A Part-VI(Sewage Disposal) 11 Total amount of Sch A Part-VII(Area Drainage) 12 Total amount of Sch A Part-VIII(Main Gate) 13 Total amount of Sch A Part-IX (External Electric Supply & DG Sets) 14 Total amount of Sch A Part-X (External Water Supply) 15 NOTE: Schedule ‘A’ Part-IIto Part-X items which are notPrepriced by MES are given in Sch A Part-XI, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as 0.0 are for that purpose. 16 SCHEDULE A PART-XI (MISCELLANEOUS B/R AND E/M WORKS) 17 S & F Angle Holder, PVC/Polycarbonate type with back plate including LED Bulb, 15 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. 18 Supply, Installation, Testing and commisioning Monoblock pump set suitable for 415 V, 3 phase system having capacity 3 HP Flow rate 13-9.4 LPS, Head Range 12-16 m complete all as specified and directed. 19 Supply, Installation, Testing Three Phase digital starter panel with auto switch,Timer and motor safety (TPM-A),Input supply:415V, 50Hz Load capacity: 5 Amp.(3HP),Electronic Overload Protection: 2-20 Amp (settable),Over-voltage protection: above 490V,Under-voltage Protection: Below340V complete all as specified and as directed. 20 M&L for construction of brick masonery valve pit of size 60x60x60 cm (internal dimension) one brick thick wall in built in CM (1:4) on 100mm thick PCC type D2(1:4:8) (using 40mm graded stone aggregate) as in foundation, and rendering 15mm thick plaster in cement mortar (1:4) bothexternally & internally,external plaster shall be up to 15cm below GL, providing valve pit cover made of 3.15mm thick MS sheet/plate,including provision of hinges, handle and locking arrangement with 40x40x5mm angle iron frame fixed on top of valve pit bymeans of hold fast 40 x 40 x 5 mm angle iron frame fixed on top of valve pit by means of MS old fast 40 x 5 mm and 150 mm long, embedded in PCC (1:2:4) type B1 & (using 20mm graded stone aggregate) block of size 230 X 200 X 100mm, including two coats of synthetic enamel paint over a coat of red oxide zinc and handle and locking arrangement including taking down of existing unservicable valve and necessary earth work in any type of soil complete all as specified and as directed specified. 21 S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer complete all as specified and as directed. 22 M&L for GI bracket fabricated out of light grade GI Tubing of 32 mm dia, 1.5 mtr long of one sided Arm type and along with 02 sets of suitable size of clamps and nut & bolts to fix the bracket on steel tubular pole and inclusive of one primer coat, one under coar and one finishing coat of paint (synthetic enamel) complete all as specified and directed by Engr-in-Charge 23 S&F PVC insulated FRLS copper conductor wire 1.0 Sqmm, 3 Core, multistranded cable for Providing Connection from Street Light Fitting to Overhead Line/ Junction Box complete all as specified and as directed. 24 Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 400 Amps for phases andneutral, install on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP54) and painted with two coats of syntheitc enameled paint over a coat of red oxide primer and made out of 3.15mm CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock make Navtal/Harrison and including grouting of panel with necessary PCC work icomplete all as specified.The scope of work includesthe following accessories with ciruit breakers:- INCOMING:- (i) MCCB 4 pole 16 kA,415 Volts,3 phase 63 Amps - 01 No(ii) Digital Multi function meter showing :- Volt meter 0 to 500 Volts, Amp meter 0 to 200 Amps – 01 No(iii) Indicating lamp LED type one set in incoming phases.(iv) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs(v) Connection from MCCB to Busbar shall be of solid Aluminium conductor(vi) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cableOUTGOING:-(i) MCB TPN, 240V, 10 KA, 32 Amps - 01 No(ii) MCB SPN, 240V, 10 KA, 10 Amps - 03 Nos(iii) Security Light Timer complete (Such as Time switch, Power Contactor, MCB TPN) - 01 No 25 Supply installation of 10 KV silent Diesel Engine driven generating set 415 Volts 3 phase 4 wire, engine as per IS 10001/10002 and Alternator as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure , control panel having meter and sound proof canopy as per CPCB norms and including foundation etc, complete all as specified and directed by Engr-in-Charge. 26 S&F 150/160mm PVC (SWR) pipes (ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 27 M& L for Sup Septic tank 3000 ltr (for 12-15 users), complete as directed 28 M & L for 10-15 mm glass fibre reinforcement concrete with mixture of hydraulic cement, silica sand, alkali resistant, glass fibre and water, durable, non combustile and fire resistantcomplete all as specifiedMake:- Swastik/ GRC/ Asian GRC/ GRC India/ UNIStone 29 Design and Details drg of Main Entrance Gate ( Two Way, In & Out width 7.0m each and 6.0 clear ht) incl Sentry Post( Int Size- 1.6m x1.6 m) as per tentative plan and elevation attached for general idea with following parameters:- (a) Concrete Grade-M25: (b) Reinforcment steel- Fe 500D: (c) Seismic Zone -V: Note:- Design and details drg to be vetted from any Govt EnggCollege. complete all as specifed and directed