| 1 | Schedule \"A\" |
| 2 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft and loose soilcomplete all as specified and as directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, andgetting out in soft and loose soil complete all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. |
| 6 | Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 7 | M&Lfor PCC 1:3:6 type C2 using 40mm graded aggregate as in walls or retaining walls, any thickness, size or shape including pilasters,buttresses columns, pillars boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 8 | M & L for PCC 1:4:8 Type D2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand) |
| 9 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 10 | M&L hardcore of gaugen exc 63mm, broken stone or bouldersdeposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface completed all as specified and directed. |
| 11 | M&L for 75mm thick cement concretetype D21:4:8 (using 40mm graded stone aggregate) as in subcompleted all as specified and directed. (Using Dimapur Sand) |
| 12 | M&L for 40mm thick plain cement concrete1:1.5:3 Type M20 nominal mix (using 20mm graded crushed stone aggregate) as in floor, finishes even and fair to receive floor tiles complete all as specified and directed. |
| 13 | M&L for glass dividing strips 3mm thick and width of strip 38mm complete all as specified and directed. |
| 14 | M & L for rendering 10mm thick plaster incement mortar (1:6) on fair faces brick work or concrete surfacesfinish the surfaces even and smooth without using extra cement complete all as specified and as directed. (using Dimapur Sand) |
| 15 | M&L for rendering 15 mm thick on other than fair faces of brick work in cement mortar (1:4) using water proofing compound @ 2% by weight of cement as per manufacture instruction and finishing the surface even and smooth without using extra cement complete all as specified and directed.(Using Dimapur Sand)[Note: WPC will be measured and paid separately) |
| 16 | Supply only intergral water proofing compound complete all as specified and directed. |
| 17 | M&L for preparation of new plastered surfaces applying two coats of cement base paint over a coat primer complete all as specified and directed. |
| 18 | M&L for preparation of surface plastered or unplastered new surface on wall and applying three coats of white wash complete all as specified and directed. |
| 19 | S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A)complete all as specified and directed. |
| 20 | S&F mild steelFramed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165including pintel hinges,stops,sliding bolt,monkey bolt etc complete all as specified and directed. |
| 21 | S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes conforming to Fe 410-W (Gde-E-250 quality A)complete all as specified and directed. |
| 22 | S&F Exe. 4Kg Weight per sqm Welded steel wire fabric supplied and fixed to wood or steel members expanded metal complete all as specified and directed. |
| 23 | M&L for preparation of newlypainted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 24 | S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedcomplete all as specified and directed. |
| 25 | S & F 150mm mild steel barrel tower bolt,stove enamelled black,with bright bolt and fixedcomplete all as specified and directed. |
| 26 | S & F 125mm long mild steel pressed handles, oval type,stove enamelled blackcomplete all as specified and directed. |
| 27 | S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. |
| 28 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 29 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 30 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection with 150 mm wide saucer drain including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) |
| 31 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade \"A\" complete all as specified and directed. |
| 32 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 33 | M&L for 5mm thick plaintinted sheet glass ordinary quality in squares not exc 0.5 Sqm each pane for aluminium window complete all as specified and directed. |
| 34 | M&L for 100mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 35 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed with grey cement and pigments and pointed in neat cement slurry in floors including 15mm thick sreed bed in CM 1:6 complete all as specified and directed. |
| 36 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 37 | One ceiling/exhaust fan point controlled by one, one way switch |
| 38 | One socket outlet 5 Amps 5 pin on independent board |
| 39 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 40 | All as per item No. 35.00 here-in-above but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 41 | S&Fmodular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 42 | S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 43 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 44 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 45 | S&Fmodular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 46 | S&F Sheet metal enclousre(for DB\"s when MCB to be used) Triple pole and neutral double door with rated bus bar 200 Amps, 4way, 415 Volts without MCB complete all as specified and directed. |
| 47 | S&F MCB TPN, 415 V, 63 Amp with breaking capacity 10KA \"B\" series complete all as specified anddirected. |
| 48 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. |
| 49 | S&F MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 50 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 51 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 350mm x 300mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 52 | M&L for submain wiring with 2 single core 6.00 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 1 X 6.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed.(Note : Two run of single core cable and one run earth wire will be measured as one length) |
| 53 | S&F LED flood light 30 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and incl eassy to instl with base plateconnection complete all as specified and directed. |
| 54 | Supply and Fixing ceiling fans complete with blades, down rods including electronic regulator and remote accessories , 230 V, 1200 mm sweep.Min air deleivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 55 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately) |
| 56 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 57 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 58 | Supply and laying wellburntsub class‘B’ bricks( designated 75) locally available best quality, laid dryin trenches forprotection of underground cable complete all as specified and directed. |
| 59 | Supply, laying, Jointing and testing in repair of LTUG cable XLPEinsulated,PVC bedded galvanised steel strip or wirearmoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 3.5 core laid in trenches/ on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |