Tender For Addl Altn To Bldg No P 199 At Milit Girinagar Pune 25; 1 B/R PORTIONDismantling plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof covering complete all as specified and directed. 2 S&F Structural rolled steel in plates, girder,channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality A.complete all as specified and as directed 3 S&F Structural steel work conforming to Fe-410 W (Gde E-250) quality A in joist channel,angle or tee section, fixed independently w/o convering plate including necessary cutting,drilling etc. complete all as specified and as directed 4 S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 Complete all as specified and as directed. 5 M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces over 10 cm width or girth, complete all as specified and directed. 6 S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering /cladding to wall fixed with self tapping screws including fixing existing turbines with necessary fixing arrangements (riveting/bolting incl sealing gaps) etc complete all as specified and directed. 7 S & F 2.5 mm dia Nylon wire (Bird proofing), 50 mm size mesh of any colour as approved including all fixing arrangements, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling as in bird proof mesh in hanger and the like etc with necessary scaffolding as required in height of hanger with safety measures complete all as specified and directed.Note : Warranty of 10 years shall be given by contractor on non judicial stamp paper alongwith FDR (Security deposit of 2.5% of quoted amount or Rs 10,000/- whichever is more) w.e.f actual date of completion. Make : Garware, or equivalent as approved by GE. 8 M&L for Brickwork with flyash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. 9 M & L rendering 15mm thick on brick wall or concrete surfacein cement mortar 1:4 mixed , finished even and smooth without using extra cement complete all as specified and directed. 10 M & L for Granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.complete all as specified and as directed 11 S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 12 Excavating in post holes (or similar holes) each n.exc 0.50 cum in any type of soil andgetting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in hard/dense soil complete all as specified and directed. 13 M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation filling or mass concrete or simillar work complete all as specified and as directed . 14 Dismantling fencing wire mesh,any type complete all as specified and as directed . 15 Dismantling posts or struts (wood, steel or RCC), any section, including taking out embeded portion from natural ground and making good disturbed ground complete all as specified and directed. 16 S&F Galvanised chain link fencing of mesh size 50mm x 50mm, line wires of dia 3mm , Galvanised including standards rails, straining bolts, etc including provision of binding wirecomplete all as specified and directed. 17 S&F mild steel round bars 10mm dia in chain link fencing complete all as specified and as directed . 18 S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed to other, or screwed both ends, each screwed end to be fitted with washers and hexagonal or square nut length of bolt n exc 5cm long and dia of neck 11 to 15mm complete all as specified and as directed . 19 M&L for preparation of new steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed . 20 M&L for preparation of new steel surfaces of any description, over 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed . 21 S&F Non structural steel work in fencinf posts and struts including cutting tops to shape as directed, drilling holes, notching for wire, wind ties, etc.; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified directed. 22 E/M PORTIONM&L for point wiring with 1.5 Sqmm size (nominal area) PVC insulated single core multi stranded copper conductor cable FRLSH drawn into and incl PVC casing caping/25mm conduit over and wall sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow crosses and PVC rectangular block with 3mm thick plastic laminated sheet cover as directed for mounting fittings etc like switches sockets and fan regulator incl 1.5 Sqmm size PVC insulated multistranded copper conductor cable as earth continuity conductor and connected to earth dolly for light point controlled by one switch complete all as specified and directed.(a) One light point/fan point/exhaust fan point controlled by one way switch. 23 M&L for point wiring with 4.0 Sqmm size FRLSH (nominal area) PVC insulated single core multi stranded copper conductor cable drawn into and incl PVC casing caping/25mm conduit over the wall sleeves and caps of adequate width and length with modular box and cover plate with frame as per requirement for fitting mounting switch/sockets regulators all accessories and fittings like bends, elbow crosses as directed for mounting fittings etc like switches socket incl 4.0 Sqmm size PVC insulated multistranded copper conductor cable as earth continuity conductor and connected to earth dolly for one 3 pin socket outlet, 15 amps, independant board complete all as specified and directed. 24 Supply and fix wind turbo ventilators 350mm height complete with all necessary fittings above the roof like sheet, screw, nut etc complete all as specified and directed. 25 Supply and fix turboforce wall fan 600mm air circulator 230 Volt single phase 180W air delivery 280 CMM speed 1380 RPM industrial types three bldes complete all as specified and directed. 26 S&F in repair vertical distribution board degree of protection IP43, 415 Volt total modules with 100A incoming MCCB and 4 way outgoing with 250 A rated bus bar Triple pole neutral double door complete with all as specified and directed. 27 S&F and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosing resistant complete with driver and lamp complete including fixing of 50mm GI pipe including cutting of wall/drilling for electric point, mounting post top all as specified and directed. 28 S&F modular socket 6/16 A-2/3 pin combined 3 module complete all as specified and directed. 29 S&F in repair modular switch 1 way 16 A 1 module complete all as specified and directed. 30 S&F ceiling rose three terminals PVC/Polycarbonate, isolated body complete all as specified and directed. 31 S&F modular switch 1 way 16 A 1 module complete all as specified and directed. 32 Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed. 33 Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating complete all as specified and directed. 34 S&F in repairsheet metal enclosure MCB SPN DB 08 Way double door 240 Volt complete all as specified and directed. 35 M & L for submain wiring two run of size 6 Sqmm PVC insulated electric power cable (heavy duty) 1100 Volt Grade FRLSH with stranded copper conductor with 6.0 Sqmm PVC insulated copper conductor earth wire in casing caping of suitable size (two run of 6 Sqmm cable and one of 6.00 Sqmm wire and one run of PVC conduit/casing caping will be measured as one unit) including taking down of existing unserviceable submain wiring complete all as specified and directed 36 Supply & fix 3 core 1.5 Sqmm PVC insulated sheathed multicore copper flexible cable connected with existing point complete all as specified and directed. 37 M&L for earthing with galvanized steel earth plate 60cm x 60cm 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with the top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and swashers of galvanized iron or steel and erth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including necessry excavation and earth work PCC (1:3:6) type C1 earth pit, cast iron pit cover, funnel with water pipe 20mm dia medium grade, 1.5 mtr long and 15mm bore light grade from earth plate to test point or main switch/DB as protection pipe and testing on completion including excavation earth work and disposal of surplus soils complete all as specified and directed. 38 Supply, laying/fixing& testing for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area of 25 Sqmm, 4 core complete including connection with panel with suitable thimble and all connected items complete all as specified and directed 39 Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed. 40 Supply and laying 50mm dis HDPE DWC pipe complete all as specified and directed. 41 M&L for GI pipe light grade 40 mm laid in trenches complete all as specified and directed. 42 Supply, installation, testing commisioning of Bus Bar panel, size 95 cm x 65 cm x 45 cm heigh out door type, platform mounted, totally enclosed, dust and vermin proof, openable from both front and rear side, made out of 3.15 mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50 x 50 x 6 mm angle iron frame work having front and rear hinged doors provision for earth strip connection bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals and apply spray paint with two coats of synethetic enamel paint over a coat of red oxide primer and necessary grouting/foundation all as required at site and comprising.Note : BUS BAR- Copper bus bar system of capacity 400 amp for pole duly colour coaded. 43 S&F MCCB 4 pole, 415 Volt thermal Adjustable type 0.8 to 1In, DPX3 160, 100 AMP with breaking capacity 25 KA, with extended terminal & suitable size of cable lugs and taking down old one complete all as aspecified and directed.