Tender For Comprehensive Maintenance Of Otm Accn At Dscc Under Ge Dronachal; 1 Demolition of Brick or Stone Masonry built in cement mortar etc completecomplete all as specified and directed. 2 M & L for brickwork with Fly ash Bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge 3 M & L for brickwork with sub-class `B` bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge 4 Demolition of cement concrete in ground floor, (unreinforced) paving nexc 15 cm thick (below or above GL) incl tiling if any complete all as specified and directed 5 M&L forcement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as infoundation, filling, subbase and mass concrete complete all as specified & directed. 6 M & L PCC (1:3:6) type C-2 using 40mm graded stone aggregate 75 mm thick as in plinth protection finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed 7 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. 8 M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles over and incliding screed bed 15mm in CM (1:4) complete all as specified and directed. 9 M&L glazed ceramic colour tiles, in vertical surfaces350x 250x 7 mm/ 450X 350X 7mm thick thick set and jointed in neat cement slurry and pointed in white or colou cement to match fixed over 10mm thick CM (1:3) as in backing coat complete all as specified and directed. 10 M&L for Vitrified ceramic coloured light shade 10mm thick(square/rectangular) polished,area of each tile not exceeding 0.36 Sqm as in floors over and including 20mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified& directed 11 M&L for Vitrified ceramic coloured light shade 10mm thick(square/rectangular) polished,area of each tile not exceeding 0.36 Sqm on vertical surfaces such as skirting, dado and risers to steps etc over & including 10 mm thick rendering in CM 1:4 set& jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified & directed. 12 M&L Sand filling under floor/pavementor in foundation including watering and consolidation 13 M&L machine pressed precast concrete interlocking paver block in any shape and size confirming to IS-15658-2006of 60 mm thickness M-35 grade with grey cement andpigment (reflective type) complete all as specified and as directed. 14 M&L Granite of 20mm thick (of any type and colour) work (table rubbed/grinding/ moulding and polished) in steps,jambs,pillars, window cills,cooking platforms, wash basin counter and likeover and icluding 20 mm screed bed in CM 1:3all as specified and directed. 15 M&LPCC 1:2:4 type B1(using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, mass filling/ levelling coarse as it bedding coarse and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed 16 M&L for Taking down of cement plaster in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. all as specified and directed 17 M&L for 20 mm thick rendering in CM 1: 4 on faces of brick or concrete surface, shall be done in two coats comprising 5mm thick in CM 1:4 mixed with water proofing compound @3% by weight of cement and over a backing coat of 15mm thick in CM 1:4and finished with trowel to an even and smooth surfaces without using any extra cement complete all as specified and directed.Note : Water proofing compound shall be measured and paid in respective item 18 Supply only Integral water proofing compound 19 M&L for 15 mm thick renderingbrick or concrete surface in CM 1: 6 finishing the surfaces fair & even without using extra cement complete all as specified and directed. 20 M&L for 10mm thick rendering onfair faces of brick or concrete surface in cm 1:3 finishing the surfaces fair & even without using extra cement as in ceiling complete all as specified and directed. 21 M & L Preparation of new plastered surface wall and applying two coat of Exterior weather proof water base emulsion paint over a coat of white cement basedputty complete all as specified and directed. 22 M & L for preparation of newly plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed by the Engr-in Charge. 23 M&L for prepration of new ceiling surfaces, applying 3coat of white wash on ceiling all as specified. 24 Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and as directed by the Engineer-in-Charge 25 Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by the Engineer-in-Charge 26 Taking down and re-fixing of old aluminum doors Shutter in same opening with necessary required repairs and fittings including galss rubber bedding door frame rubber bedding and glazing clips(Glass pan, floor hydraulic spring handles, mortice lock and tower bolt will be measured and paid separately) area exc 1.50 sqm but n.exc 4.00 sqm each 27 S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified. 28 Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solovent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in M.S. frame welded sealed to the stiles and rail with suitable PVC sheet beading and jointed together with solvent cement supply and fixing in the frame at site as per specification and drawing. 29 S&F Powder Coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified and as directed. 30 Hacking out old glass (any thickness size quality or description) from wooden frame or stone, concrete or brick surrounds glazed with putty or fixed with beads all as specified and directed. 31 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed 32 S&F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed 33 M&L12mm thick Prelaminated particle board, exterior grade,prelaminated both side with decorative choice lamination , fixed to aluminium door, partitions complete all as specified and as directed. 34 S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperure 1.180 mm and fixed and with tinned tacks or galvanised wire staples, complete all as specified. 35 S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kgaluminium extruded section body complete all as specified and as directed. 36 S&F for floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor complete all as specified and directed 37 S&F for 150 mm aluminium handles, cast type, anodised complete all as specified. 38 S&F for ISI Marked 200mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified. 39 S&F 300mm long aluminium allooy anodised sliding door bolts with hasp and staple (bolt type) & fixing clip of sheet cast or extruded section & fixing bolt & sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. 40 S&F for 100mm Mild steel butt hinge complete all as specified and directed. 41 S&F 4-levers Aluminium Mortice lock, vertical type, size 100 mm complete all as specified and directed 42 M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. 43 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified. 44 Dismantling of wall and celing hard boards/AC sheets and plywood in any thickness & any positionincluding cover filletscomplete all as specified and directed 45 S & F Anodised aluminium snap grid of size 605 x 605mm frame work for false ceiling all as specifiedcomplete all as specified and as directed. 46 M&L Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paidseparately) complete all as specified and directed 47 Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as spfd. 48 Dismantling timber scantlings 40 sq. cm and over in section, for unframed work in any position complete all as specified and as directed. 49 S&F steel work as in rafter, purlins, posts tubular (round/square/rectangular shape of pipes as approved by Engr-In-Charge) including postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 grade St-240 Complete all as specified and as directed. 50 S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed 51 S&F in repair 6mm thick coloured polyicarbonate sheet (ISI marked) with shelf drilling steel screw with washer on roof and joint of two sheet will be filled with silicon weather proof sealent and cover with aluminum strip of size of 50x3 mm top and bottom and fixed with shelf drilling steel screw with washer on roof complete all as specified and directed. 52 S&F in repair for 3 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with bolts and washer in roof, wall etc complete all as specified. 53 Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 54 Supplying and laying of GI tubing Dia 15mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 55 Taking up or down 20mm mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 56 Supplying and laying of GI tubing Dia 20mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 57 Taking up or down 25mm mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 58 Supplying and laying of GI tubing Dia 25mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 59 S&F 25mm bore gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed. 60 S & F in repair of ISI marked 15mm bore stop valves/angle valve concealed fancy type cast copper alloy, chromium plated with long shank and cup , screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified. 61 S&F 15 mm Pillar taps, cast copper alloy, chromium plated fancy type, chromium plated, screwed down high pressure, with or without letter hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixing complete all as specified and directed by engr in charge.Make : Prayag or equivalent 62 Supply and fixing in repair for ISI marked 15mm bore, fancy type bib tap of chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge. 63 S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed. 64 S & F for in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge 65 S&F brass chromium plated tubular towel ring complete all as specified and as directed by the Engineer-in-Charge 66 S & Fbrass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge 67 S&F in repair for vitreous China wash basin, white, flat back, size 450x300mm including PVC connections 15mm size with PTMT nuts of length 450mm,waste coupling, 40mm pvc waste pipe of suitable length, brackets,and cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed by the Engineer-in-Charge. 68 S&F in repair vitrous china white oval type under counter WHB of size not less than 195x600x425mm of first quality fixed all as specified and directed. 69 S & F in repairs Vitreous China squatting pan, `Orissa` pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PVC SWR P or S trap complete all as specified and as directed by the Engineer-in-Charge. 70 S&F in repair vitreous china wash down water closed pan (pedestal Pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including plastic seat cover complete all as specified and directed. 71 Supply and Fixing in repairs for 10 ltrs capacity PVC Valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets flushing cistern, PVC flushing pipe of suitable length and PVC connection 450mm long. complete all as specified and as directed by the Engineer-in-Charge 72 S&F in repair Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe) including urinal spreader complete all as specified and directed. 73 S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to wall with PVC clamps complete all as specified. 74 S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorss complete all as specified. 75 Supply & Fixing repair PVC Bath Cabinet mirrorcomplete all as specified and as directed by the Engineer-in-Charge 76 S&F in repair brass CPwall mixer for mixinghot and cold water screwed down for iron pipe and fixed. 77 S&F in repair brass CP centre hole mixer for (WHB) mixinghot and cold water screwed down for iron pipe and fixed 78 S&F in repair waste coupling 40mmsuitable size for kitchen sink of PTMT (half or full threaded) complete all as specified and directed 79 S&Fin repair40mm bore PVC waste pipe for kitchen sink one mtr long complete all as specified and directed. 80 S&F in repair 32mm bore PVC waste pipe for wash basin one mtr long complete all as specified and directed. 81 S&Fin repair 100mm dia CPgrating (Minimum weight 25 gms) all as specified and directed. 82 S&Fin repair PVC connection 15 mm size with PTMT nuts of length 600 mm all as specified and directed. 83 S&F in repair Plastic water closet seat,closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. 84 S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as spfd & directed 85 S&F in repair for replacement of Jet spray with holder on EWC in repairs all as specifie and directed complete Make : As per sample approved by GE 86 S&F in repair health faucets CP with 1.2 mtr long CP flexible pipe complete all as specified and as directed. 87 S&F in repair two way C.P. Bib cock 15mm dia complete all as specified and as directed. 88 Dismantling water tank capacity exc 500 ltrs but nexc 1000 ltrs and removing to stores complete all as specified and directed 89 Hoisting & Fixing 500 Ltr rotational moulded polyethylene water stotage tanks(cylinderical verticle with closed top) hoisted & fixed in position complete all as specified and directed. 90 Hoisting & Fixing 1000 Ltr rotational moulded polyethylene water stotage tanks(cylinderical verticle with closed top) hoisted & fixed in position complete all as specified and directed. 91 M & L for preparation of old plastered surfaces of wall and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required sharde & colour, as per manufacturers specification over a coat of 1mm thick putty complete all as specified and directed by the Engr-in Charge. 92 M & L for preparation of old plastered/unplastered surfaces of Ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required sharde & colour, as per manufacturers specification over a coat of 1mm thick putty complete all as specified and directed by the Engr-in Charge. 93 M&L for preparation of old plastered/unplastered and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. 94 M&L preparation of old surface of ceiling and applying Two coat white wash complete all as specified and as directed 95 S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame with5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified 96 M&L Preparation of old decorated surfaces of wall/ceiling including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spotsand removing stopping nails and applying two coat of plastic emulsion on walls/ceiling over primer and a coat of 1mm thick white cement based wall care putty all around including complete sanding of existing surface treatment with sand paper or iron patti / flat / mechanical sanding machine complete all as specified and directed. 97 M&L for Preparation of old painted surfaces of Steel/ steel based materials exc 10cm width or girth and applying one coat of synthetic enamel paint as directed and specified. 98 M&L for preparations ofold wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints all as specified and directed. 99 Waterproofing of terrace with Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnaum Product code 5662 OR Berger PU RoofKoat 100 (A) Surface Preparation(i) All surfaces should be dry and free from contamination such as oil, grease, loose particles, decayed matter, moss, algal growth, laitance and all traces of shutter release oils and curing compounds.(ii) All loose and de-bonded concrete/ screed shall be removed and proper repairing to be carried with polymer modified mortar. Washing the roof-terrace surface and making it dust free.(iii) The careful sealing of existing cracks & joints before the application is extremely important for log lasting waterproofing results. Clean concrete cracks / hairline cracks, of dust, residue or other condemnation. Fill all prepared cracks with acrylic flexible crack filler Dr. Fixit Cracks-X Paste OR Asian SmartCare CrackSeal OR Berger Homeshield Crackfill Paste.(iv) Cracks more than 5mm fill all repaired with Polymer modified cement sand mortar in the ratio of 1:3 duly admix with Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus @ 10% by weight of cement.(v) Pre wet the surface prior to application of primer and allow surface water to evaporate to make surface saturated dry (SSD) condition 101 (B) Bond Coat(i) Applying Dr Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus a SBR latex based bonding chemical used for repairs & waterproofing, at a ratio 1:1 one part chemical one part cement. Make sure bond coat is done properly and spreader evenly to the entire surface with brush or roller. 102 (C) Pre-Coat Application(i) Applying one coat of Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus with cement @ 1:1.5 one part chemical, one and a half part cement and lay 45 GMS fiber mesh on still wet coat of URP. Make sure fiber mesh sticks to the surface evenly. 103 (D) Primer Application(i) Apply one coat of acrylic based primer Dr. Fixit Primeseal Primer OR Asian PU Magnum Resin & Asian PU Magnum Hardner OR Berger SealOPrime (diluted with water in the ratio of 2:1) spreading at the rate of 8-10 /Sq.mt /Litre. Allow the primer to air cure for 4-6 hours.(E) Coating Application(i) Stir well before use. Apply 1st coat of Dr. Fixit HydroShield PUD plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. 104 (E) Coating Application (Contd(ii) Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90° to the first coat and 3rd coat at 90° to the second coat. Ensure there are no pinholes or air bubbles on the membrane surface. (iii) Apply second coat of Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat. Ensure there are no pinholes or air bubbles on the membrane. (iv) Apply third coat of Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat to achieve total dry film thickness of 800 to 1000 microns at forced coverage @ 2- 2.1 /litre/Sq.mt in 3 coats. Ensure there are no pinholes or air bubbles on the membrane. (v) Make sure glass fibre mesh is completely embedded. Surface should be smooth after the application. Check to see no void surface is left untreated / uncoated.(vi) All the concrete / masonry pedestals present on the roof, constructed for supporting the water tanks or pipe lines or dish antenna/solar panel, etc., also should be coated with extra coat of same material incorporating reinforcing fabric.(vii) Allow the system to air cure for 7 days prior to carry out ponding test.Note:- System comes with 10 years waterproofing warranty from Manufacturer or Authorized Applicator. 105 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 106 M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multi-stranded copper conductor FRLSH in and incl PVC casing and capping ISI marked 20/30 mm size or as required at site incl with its fittings and fixture such as tees, bends, elbows and juction boxes all moduler type surface mountingetc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal complete all asspecified and directed.Note :- Modular PVC Surfacemounting boxes and for mounting switch ,socket withmodular frame plate and covercomplete all as specified and directed 107 (a) One light/Fan/Exhaust fan point controlled by one switch. 108 (b) One 3 pin socket outlet 5 Amps on independent board. 109 (c)One 3 pin socket outlet on same board. 110 M&L for wiring complete 2.5 Sq.mm single core multi standard copper conductor FRLS PVC insulated 650/1100 Volts drawn through non metalic rigid PVC casing capping including necessary accessories like bends lees and elbows etc fixed on wall/ceiling including sunken type pressed steel terminal boxes of suitable size with plastic laminated white/coloured top sheet cover 2 mm thick including 1.5 Sq.mm FRLS PVC insulated copper green wire for earth wire complete for 3/5 pin 15 Amps switch socket combination complete all as directed by Engineer-in-Charge. 111 S&F in repairs modular switch flush single pole one way 6 Amps. 112 S&F in repairs socketmodular outlet 5 pin with gang box 6 Amps 113 S&F in repairs socket modular outlet 5 pin 15 Amp with gang box multipurpose. 114 S&F in repairs modular switch flush single pole one way 15/20 Amps. 115 S&F in repairs sheet metalsingle pole and neutral encloserwith a two pin and earth plug and socket complete with one MCB SPN 20 amps, 240 V. 116 S & F in repairs Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top 117 Supply and fixing in repair of MCCB forDPX 415 Volts 100 Amps 4 pole with breaking capacity of 25 KALegrand/ Schinider/ C&S 118 Supply & Fixingin repairs MCB DB TPN 415 Volts 200 Amps rated bus bar having 4 way single door shutter. 119 Supply & Fixingin repairs MCB DB SPN240 Volts 200 Amps rates bus bar having 4 way double door shutter. 120 Supply & Fixing in repairs MCB DB SPN 240 Volts 200 Amps rates bus bar having 8 way double door shutters. 121 S&F in repairs MCB TPN 415 Volts of capacity 63 Amps complete all as directed by Engineer-in-Charge. 122 S&F in repairs MCB SPN 240 Volts of capacity 40 Amps complete allas directed by Engineer-in-Charge. 123 S&F in repairs MCB SP 240 Volts of capacity 5 to 30 Amps complete allas directed by Engineer-in-Charge. 124 S&F sub main wiring4 Sqmm with three runs of 4 sqmm single core multi stranded copper conductor in PVC conduit including all fitting fixed on wall/ceiling including4 Sqmm PVC insulated copper earth wire connected to earth including taking down, complete all as directed by Engineer-in-Charge. 125 S&F sub main wiring6 Sqmm with three runs of 6 sqmm single core multi stranded copper conductor in PVC conduint including all fitting fixed on wall/ceiling including6 Sqmm PVC insulated copper earth wire connected to earth including taking down, complete all as directed by Engineer-in-Charge. 126 Supply & fix in repairs recess mounted LED 15 Watt Ultra slim recess-mounting round LED downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins for larger surface area finished in epoxy powder-coated white to deliver high-efficacy light output and uniformity, utilising edge-lit technology. 127 Supply & fix in repairs ceiling mounted LED light fitting 36 Watt Recess-mounting ultra-slim LED 2x2 edge-lit tile in aluminium extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as directed by Engineer-in-Charge. . 128 Supply & fixin repairsceiling mounted LED light fitting 36 Watt surface panel ultra-slim LED 2x2 edge-lit tile in aluminium extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as directed by Engineer-in-Charge. . 129 S&F in repairs LED flood light fitting 150 watt LED floodlight luminaire High-efficiency IP65 innovative LED floodlight with pressure die-cast aluminium housing and toughened glass in the front with unique flood optics to ensure uniform distribution and savings upto 50% as compared to conventional system 130 Supply & fixin repairs Wall mounted LED - 20 W Linear Aluminium High Lumens output LED batten made from aluminium extruded channel, powder coated with opaque diffuser for glare free light complete with accessories all as specified and directed. 131 Supply & fix in repairs Wall mounted LED batten 10 watt LED - Linear Batten made from Polymer extruded channel, with opaque diffuser for glare free light, complete with accessories all as specified and directed. 132 S&F in repairs LED lamp 9/10 W, 230VAC, 50Hz, cool white single phase with all fitting and fixing accessories complete all as specified and directed. 133 S&F in repairs LED inverter lamp 20 W, 230VAC, 50Hz, cool white single phasewith all fitting and fixing accessories complete all as specified and directed. 134 S & F in repairs modular stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd 135 S&F in replacement piano type switch single pole 230 volt flush type 5 Amps 136 S&Freplacement piano type switch single pole 230 volt flush type 16 Amps.(Normal switch) 137 S&F in replacement switch socket combination withpvc gangbox 6/16 Amp as per existing ISI mark.(Normal type) 138 S&F in replecement switch socket combination with pvc gangbox6 Amp as per existing ISI mark. 139 Supply and fixing in ,replacement ELCB 63 Amps, 4 pole 140 S & F in repairs Modular Metal flush box 3 module 141 S & F in repairsModular White cover plate 3 module 142 S & F in repairs Modular Metal flush box 6 module 143 S & F in repairsModular White cover plate 6 module 144 S& Fin replacement of PVC 3 Pin plug top 15 Amp complete as specified 145 S& Fin replacement of PVC 3 Pin plug top 5 Amp complete as specified 146 S&F energy saving and enviornment friendly long life LED security light fitting 1 x 36W LED, versatile, pressure die cast aluminium IP-66 protection with high power LED as light source and arcylic cover etc incl all accessories prewired complete including mounting on bracket and necessary connection to ceiling rose etc & suitable bolts and nuts with washers, connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqmm three core from ceiling rose to fittingincluding taking down the old one, complete all as specified and directed. 147 M & L for Servicing of1200/1400 mm ceiling Fan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes and painting including replacing of un serviceable part like bearing gun metal bush condensor of suitable capacity and re-assembling the same and complete all as directed by Engineer-in-Charge. 148 M & L for Servicing of 250/300/350mm Exhaust Fan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including replacing of un serviceable part like bearing gun metal bush condensor of suitable capacity and re-assembling the same and complete all as directed by Engineer-in-Charge. 149 Supply and fix building security light bracket, bend to 120 degree angle, made out of 32 mm bore, galvanised iron, light grade tubing (approx 1.2 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc.and two coats of synthetic enameled paint over a coat of red oxide primer including taking down the old unserviceable one complete all as specified and directed. 150 Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6.3mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron wire of4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and earth wire protected by galvanized pipe light grade 40 mm bore and thorugh test point including necessary earth work and excavation in any type of strata, andGI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete 151 M&L earthing complete with copper plate of 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level withcopper strip 20 x 3 mm as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixedin continuous layer 15 CM all around the plate and balance pit will be filled with vigitable soil approved byengineer in charge, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI framewith cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe of suitable size protection for earthing lead from earth pit to test point complete & making connection 152 M&L for installing and commissioning Copper coatedChemical Earthing electrode oflength 3 mtr, inner dia of 40 mm and outer pipe of dia 76 mm with minimum thickness of 250 micron, after boring 20 metre deep, 150 mm in diain hard/soft soil with help of boring machine,filling the bore hole withblack cotton soil upto 17 mtrs level i.e below the electrode bottom level, filling remaining portion by pouring suitable chemical bentonide compoundduly mixed with water and filling earth enhancement material (minimum approx. 30 kg) into the augured hole in slurry form and allowed to set, covering of the composite structure (earth electrode + earth enhancement material), covering remaining portion with backfill soil/ material, welding copper strip with existing head of earth electrode including necessary PCC earth pit work and including all necessary nut, bolts, washers etc complete 153 Taking down unserviceable geysers of any capacity and make from each location by disconnecting and sealing all electrical and water lines for annual maintenance/servicing. Overhauling, dismantling the same for repair/replacement of unserviceable parts, including brazing to inner tank, cleaning, taking out sludge from inner tank and washing with cleaning solution and reassembling and refixing the same in each original location/ position, connecting all electrical and water connections including provn of 2.5 Sqmm 3 core sheathed multi-stranded copper conductor flexible cable from connector block to geyser and testing complete all as specified and directed. (NOTE (a) New parts shall be measured and paid separately under Supply only rates here-in-after. (b) Minor parts, if any, not mentioned in the schedule but required for smooth functioning of geysers are deemed to be included in the rate of the item.) 154 Supply only PVC inlet pipe, 15mm bore, 450 long including both end check /end nuts and washers. Make 155 Supply only PVC steel braided outlet connection pipe, 15mm bore, 450 mm long including both ends check nut & washer complete. 156 Supply only heating element of any type 1500 Watts. 157 Supply only heating element of any type 2000 Watts. 158 Supply only thermostat of any type suitable for 25 ltrs capacity geyser. 159 Supply only internal assembly complete with packing ring, bolts, nuts & washers suitable for 25 ltrs capacity geyser. 160 Supply only thermal cut off ISI marked suitable for 50/35/25 ltrs capacity geyser. 161 Supply only fusible plug made of brass having lead alloy fuse suitable for 25 ltrs capacity geyser. 162 M & L for painting geyser of capacity 25 ltrs complete, in situ, with two coats of synthetic enamel paint, white, by spraying including filling cavities with filler, denting after scrubbing down old paint using emery paper, cleaning, washing etc. and writing MES No complete all as specified and directed. 163 S&F in repairs change over 32 Amps 4 pole 415 V complete all as directed by engr-in-charge. 164 S&F in repairs change over 63 Amps 4 pole 415 V complete all as directed by engr-in-charge. 165 Attending daily complaints of DSCC and 14 Acre land area by deputing adequate number of Skilled teams of qualified Electrician and helper any time of the day ( Minimum 01 Skilled Electrician & 02 Helper ) for repair / tightening of end terminals of street light fitting, Flood light, LED strip on poles , High Mast light , Post top lanten of any size/capacity at anyheightand repair the street lights, Flood lights and Post Top lanten having minor faults i.e loose connections, carbon deposition , Shiftingand refixing the same etc and makethe light functional.After rectifying the defects of the electricalsystemreplace the U/S items such as street light , flood lights, LED strips, MCBs TPN ,connection plate , thimbles and timmersmall pieces of electrical cables PVC insulated copper multistranded conductor of sizes 2.5 Sqmm to 6 Sqmm twin core and length not increasing 1.5 mtrs completeall as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill) and In Addition one 16 mtrs hight hydraulic vehicle with driver & operatorof the same team will opearte and manage day to day street light Complaints and update the status of complaints on daily basis and confirmed throgh concerned JE E/M daily as per directed by Engr-in Charge. 166 Note:- (i)Complaint shall be done within 24 hrs afterintimation by JE E&M Engineer-in-Charge failling whichpenalty of Rs 250 per day per complaint will be levied on contractor.(ii) One supervisorwill report to JE E/M , Engineer -in-Charge on daily basis with complaint register. (iii) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis ( Format as per provided by the Engineer in Charge.(iv)This item pertains to attending complaints ofstreet light/flood light/LED strips on poles/High mast, MCB, & timer panel including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge.(v)Items shall be measured and paid seperately under respective item of Sch A 167 S&F in repair of Automatic Street Light Switch Three phase with Nature Switch-03 as the controlling unit for automatic switching of street lights based on LUX level of Natural light. The Sensor (Nature switch) along with suitable power contractor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust proof, Electric Shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) confirming to IP54. The contractor, MCB and circuit Wiring should suitable enough to take load5 KW equally distributed over 3 phase (4 KW/Phase). The contractor rating 25 Amps (4-pole) and MCB(single pole) rating : 20-25 Amps(SP-03 Nos), complete all as specified and directed.Make. Nature Switch Model No SWADEEP-02EC 5 KW3P or equivalent makes in Legrand/L&T/GE. 168 M & L for replacement of LED aviation light luminaries comprising of aluminium housing with polycarbonate enclosure complete Make : Bajaj/Philips/Havells complete after taking down the old unserviceable one all as directed. 169 M&L for taking down High Mast light fittings mounting on cage from High mast pole of 12.5/16/20 mtrs heightfor repairing of LED/MH light fitting of any size/type and reinstalling the fitting/cage back to its position after carrying out repairs all as directed by EIC (Cost of LED spare parts will be measure seperately) 170 M&L for rewinding ofexisting burntmotor 2 HP of high mast light fitting with replacement winding wire and refixing the same alongwith proper alingment with steel rope etcincluding electrical connection and testing complete all as directed by Engr-in-charge. 171 Supply and replacement of Existing High mast panelfront door openable with 3.0 mmthickness MS sheet of size 0.9x0.6x0.6mpowder coating paint including locking arrangement , Panel internal wiring of suitable size wire alongwith 63 Amp MCCB as incomer and 03 Nos 40 Amps MCB as outgoing and mounting on 40x40x6 mm MS angle and grouted in PCC completeincluding one coat synthetic enamel paint complete all as per directed by Engr-in-charge 172 Supply and fixingin replacementoutdoor type IP66 thermoplastic polycarbonate cable entry junction box of size 155 x 210 x 92 mm, weather proof with knockouts for cable entry- black colour with necessary cable connector link inside the box and fixing arrangement by clamp, nut bolts etc fixied on pole/ walls complete all as specified and as directed. Make - 173 Supply & fixing in replacement of new generation energy saving and environmental friendly long life LED street light 60 watt made up of pressure dia cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07by using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed.Make : Havells, Cat No-ENDURAPEARLNEOL60WLED757PASYTOPC or equivalent of Philips/Jaquar. 174 S&F in repairs aluminium strip of size 25 x 4 mm fixed to wall/ pole with aluminium saddles andscrews for roof/ down conductor above ground/ buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after 175 S&F in repairs Copper strip of size 20 x 3 mm fixed to wall with copper saddles andscrews drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit shall be measured and paid separately under appropriate items here in after 176 S&F in repairs fixing Galvanised iron strip of size 32 x 6 mmfixed to wall with Galvanised iron saddles andscrews / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit/pipe shall be measured and paid separately under respective item of works