Tender For Spl Repair To Bldg No T-21 Of 50 Mvh Cl-Iii And Provn Of Cemented Hardstanding At Eqtn Sec At Ota Gaya; 1 Demolition of cement concrete(unreinforced ) in ground floors and pavings not exceedidng 15cm thickness(below or aboved ground level) complete all as specified and directed 2 M&L For Machine cut kota stone slab flooring 20-25mm thick over and incl 20mm thickcement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed 3 M &L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm in CM 1:4 and jointed complete all as specified and directed 4 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed 5 M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius,old size bricks built in CM 1:4 complete all as specified and 6 Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed 7 M & L for rendering 10mm thick internal surfaces on brick work in cm 1:6 in and finishing surfaces even and fair without using extra cement complete all as specified and directed 8 M & L for rendering 15mm thick in two layerson external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC 3% by wt of cement complete all as specified and directed by engr in charge.Note:-WPC measured and paid separatly 9 Supply only integral water proofing compound of approved brand/ make.complete all as specified and directed 10 M&L preparing New plastered surfaces of wall and applying complete wall with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed 11 M&L preparing Old plastered surfaces of wall and applying complete wall with1.0 mm Wallputty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed 12 Preparing Old plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed 13 Preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed 14 Taking down chowkhats or frames not exc 1.5 Sqm ( without taking shutters from the frame). 15 Taking down chowkhats or frames exc 1.5 Sqm ( without taking shutters from the frame). 16 M&L for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified and directed 17 M & L for providing cement concrete Type C1 1:3:6 using 20mm graded stone aggregate as in Hold fast block. 18 M & L two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed 19 M&Lfor 35mm thicksecond class hardwood glazed and skelton doorshutters (Three panels) open rebated and prepared to receive glass / gauge etc edges of framing plain chamfered or rounded with cut and mitred beads for securing glass/gauges etc with sash bars size of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a)complete all as specified and directed 20 M&L for 30 mm thick Flush shutters, solid core construction, with block board core plywood face panels on both side, commercial type on both sidesincluding 5 mm thick edging/beading on exposed to view on sides & topcomplete all as specified and directed 21 M&L two coat of synthetic enamel paint over new woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete all as specified and directed 22 S&F 125 mm long Stainless steel butt hinges with steel hinge pin etc complete all as specified and directed by engr in charge 23 S&F 200mm long aluminium anodised barrel tower bolt and fixedcomplete all as specified and directed by engr in charge 24 S&F 150mm long aluminium anodised handle cast type and fixed D Typecomplete all as specified and directed 25 S&Falluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 300 mm long complete all as specified and directed 26 S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed 27 S & F Powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws,etc complete all as specified and directed by engr in charge. Note : (i) Glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item.(ii) Item shall be paid as per weight of aluminium section (iii)The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight.(iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 28 S&F Aluminium Partition wall of section as in frame size 63.5 X 38.1 x 2mm thick of make Jindal or Equivalent, incl 8mm thick Glass / 12mm thick prelaminated particle boardpaneling including MS Channel ( Size of paneln.exc 1.5 Sqm each ) and all necessary fittings all as approved 29 S&F 5mm thick tinted glass in aluminium doors & windows with rubber packingincluding hacking out old broken glass complete all as specified and directed by engr in charge. ( any thickness, size from aluminium beading ) 30 S&F in Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding/Staples directed 31 M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, framed guard bars; barred iron doors and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 32 Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed by engr in charge. 33 S & F of Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed by engr in charge. 34 S&F 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed by the Engineer-in-Charge. 35 S & F in repairs of 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system complete all as specified and directed 36 Supply & Fixing in repairs Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers complete all as specified and directed. 37 Surface excavation not exceeding 30cm deep and averaging 15cm deep getting out in Soft/loose soil for foundation etc. 38 M&L for Hard core of gauge n exc 63mm thick of broken bricks spread leveling watering ramming to true surface complete all as specified and directed 39 M & L for 100 mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in surface of hardstanding finished even and smooth without using extra cement including spike rolling to surfaceor making impression of expanded metal, whilst the concrete is green complete all as specified and directed. 40 M & L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed. 41 M & L for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ all as specified and directed. 42 Removing of excavated Soil n exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed 43 Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches, ceiling roses, pendent, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed at site. 44 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. 45 Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/ concealed/ existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 46 Taking down ceiling fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M Gaya complete all as specified and as directed. 47 M & L for point wiring using approved colour coding as per IS with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- 48 (a) One light point controlled by one way switch 5 Amps 49 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator 50 (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. 51 (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. 52 Description all as per item No 5 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 53 S & F switch piano flushtype, single pole, one way and 5/6 Amp single complete. 54 S & F socket outlet 2 in 1, 5 pin, 5 amp, 230 volts complete all as specified and directed. 55 S &F switch socket combination2 in 1, 3 pin, 6 and 15 amp flush typeuniversal. 56 S & Fstepped type fan regulator flush type complete all as specified and directed 57 S & F ceiling rose, surface bakelite with 3 terminals, ISImarked for batten fitting complete all as specified. 58 S & F for sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 59 S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 60 S&F in replacement of MCCB 4 pole, 100 to 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed. 61 S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 62 S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 63 M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 64 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. . 65 S & F building security lightfitting 1 x 35/36 W LED new generation energy saving & environmental friendly long life LED street/bldg security light made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having top opening including driver compartment driver with IP66 protection and impact resistance of IK07 including with suitable for 32mm dia medium grade G I bracket not exc 1.5 mtr length made to shape & fixing on pole/wall with 2 nos of MS clamp including necessary connection from LT OH line/buildings 66 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. 67 Re-fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories complete all as specified and as directed. 68 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 69 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm x 3.5 Core passing through DWC HDPE / in trench including necessary connection with lugs and cable gland etc complete all as specified and directed. 70 Galvanised iron steel tubes, ISI marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified. 71 Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr in depth in hard/dense soil for taking up/ laying of cable and getting out complete all as specified and directed. 72 Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. 73 Removing surplus soil to a distance n.exc 50 mtr and making good the disturbed surfaces complete all as specified and directed. 74 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. 75 Supply and laying for brick of common burnt clay, sub class B old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other complete all as specified and directed. 76 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.