}

Tender For Room Construction Work In Government School In Village Kahani Nagla - Civil Works 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On , ghaziabad-Uttar Pradesh

Rural Development Department has published Tender For Room Construction Work In Government School In Village Kahani Nagla - Civil Works 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On . Submission Date for this Tender is 28-08-2025. Building Work Tenders in ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50814687
Corrigendum : Tender For Room Construction Work In Government School In Village Kahani Nagla - Civil Works 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On
Tender
Indian
Uttar Pradesh
Ghaziabad
28-08-2025

Tender Details

Tender For Room construction work in government school in village Kahani Nagla - CIVIL Works 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per DSR-2023 S.I No. 2.8.1 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per DSR-2023 S.I No. 4.1.8 4 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as per DSR-2023 S.I No. 5.1.2 5 Centering and shuttering including stutting, propping etc. and removal of form.Foundation as per DSR-2023 S.I No. 5.9.1 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)Above Plinth Lvl as per DSR-2023 S.I No. 5.2.2 7 Centering and shuttering including stutting, propping etc. and removal of form.Column as per DSR-2023 S.I No. 5.9.6 8 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR-2023 S.I No. 6.1.2 9 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per DSR-2023 S.I No. 2.27 10 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto Plinth Lvl as per DSR-2023 S.I No.5.1.2 11 Centering and shuttering including stutting, propping etc. and removal of form.Beam /Band as per DSR-2023 S.I No. 5.9.5 12 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) as per DSR-2023 S.I No. 2.25 (a) 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) as per DSR-2023 S.I No. 6.4.2 14 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (Slab) as per DSR-2023 S.I No. 5.3 15 Centering and shuttering including stutting, propping etc. and removal of form.Slab as per DSR-2023 S.I No. 5.9.3 16 Steel reinforcement for R.C.C. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per DSR-2023 S.I No. 5.22 B.1 17 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. As per DSR-2023 S.I No. 13.9.1 18 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Outer Side as per DSR-2023 S.I No. 13.4.2 19 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Inner Side as per DSR-2023 S.I No. 13.5.2 20 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand )Below Plinth as per DSR-2023 S.I No. 13.5.1 21 Providing & laying rectified glazed ceramic floor tiles of size 300x300 mm or more ( thickness to be specified by the manufacturer), of 1st quality confirming to IS:15622, of approved make, in colours white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grounting the joints with white cement and matching pigmrnts etc., complete as per SI no. 11.39 22 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. as per SI no. 11.37 A 23 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per DSR-2023 S.I No. 13.46.1 Two Coats 24 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per DSR-2023 S.I No. 13.41.1 Two Coats 25 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as per DSR 2023 S.I. No -13.80 26 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. As per DSR-2023 S.I No. 12.41.2 27 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. As per DSR-2023 S.I No.12.22 28 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. as per DSR-2023 S.I.No.10.2 29 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.as per DSR-2023 S.I.No.10.25.2 30 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece as per DSR-2023 S.I.No.10.5.2. 31 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.as per DSR-2023 S.I.No.10.25.2 32 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per DSR-2023 Sl no. -13.62.1 33 Providing and Laying Intergal cement based water proofing treatment ( Brick Coba)including prepartion of surface as required for tratment of roofs, balconies teraces etc. As per DSR-2023 22.7 34 Electrical Works 35 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. as per DSR(E&M)-2022 Sl no.1.10.3 Group-C 36 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductorsingle core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.as per DSR(E&M)-2022 Sl no.1.12 37 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.as per DSR(E&M)-2022 Sl no.1.14.1 38 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.as per DSR(E&M)-2022 Sl no.1.14.2 39 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.as per DSR(E&M)-2022 Sl no.1.31 40 SupplyingandfixingsuitablesizeGIboxwithmodularplateandcoverinfronton surfaceorinrecess,includingprovidingandfixing6pin5/6&15/16Amodular socket outlet and 15/16 A modular switch, connections etc. as required.as per DSR(E&M)-2022 Sl no.1.32 41 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.as per DSR(E&M)-2022 Sl no.1.25 42 Supplying and fixing brass batten/ angle holder including connection etc. as required.as per DSR(E&M)-2022 Sl no.1.34 43 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.as per DSR(E&M)-2022 Sl no.2.10.1 Single pole 44 Supplying and fixing following rating, four pole, (three phase and neutral), 415 V,residual current circuit breaker (RCCB), having a sensitivity current 30 n1A in the existing MCB DB complete with connections, testing and commissioning etc. as required.as per DSR(E&M)-2022 Sl no.2.15.3 63 Amp. 45 Supply and fixing of LED Tube Light with batten suitable for upto 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. - CAT-AAA. As Per UPPWD-1413 46 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate material and driver set complete in all respect. CAT-AAA. As Per UPPWD-1410 47 Supply and fixing of M.S sign board of prescribed size 1.20m *2.75 m with angle 40*40*6 mm iron angle and 1 mm thick ms iron sheet including painting and letter writing complete. As per SE RED Meerut, Sanction letter No.1108 Dated 09.10.18

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 27-08-2025 Date Date 28-08-2025

Key Value

Document Fees
INR 2360 /-
EMD
INR 32940.0 /-
Tender Value
INR 16.47 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail