Tender For Stock Storageof Division Nerwa Distt. Shimla (HP) (SH:- Electrical installation for EE Office /AE office and Staff, Lab etc)-- 1 Wiring for light point/fan point/exhaust fan/call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVCConduit conductor and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Group ( A.) 2 Wiring for power plug with 2x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduitalong with 1 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.) 3 Wiring for power plug with 4x4 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVCConduit along with 2 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.) 4 Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduitalong with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 5 2x1.5 Sq.mm. 6 2x10 Sq.mm. 7 Supplying & Fixing Metal boxes of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 8 12 modul 8X6 9 6 modul 8X3 10 3 modul 4X3 11 4 modul 5X3 12 2 modul 3X3 13 Supplying and fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 14 S.P. 5/6 Amps one way switch, piano type. 15 S.P. 15/16 Amps one way switch, porcelain base/paino type. 16 5 pn 5/6 Amps socket outlet, poreclain base/piano type. 17 6 pin 15/16 Amps socket outlet, porcelain base/piano type. 18 Supplying and fixing bakelite batten/angle holder including connections etc. as required.with in all leads and lifts as per direction of the Engineer-in-Charge. 19 Supplying and erection of 6 amps, to 32 amps, rating, 10 KA breaking capacity, 240 volts, C curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.Single pole . Cat-A 20 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.40 Amps. Cat- A 21 Supplying and fixing of following way, single pole and netural sheet steel MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels inter-connections phosphatized and powder painted, including earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.Single door-6 way 22 Earthing with G.I. earth pipe 4.5mtr. Long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 23 Extra for using salt and charcoal for pipe earth eletrode complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 24 Supplying and laying 6 SWG G.I. wire at 0.50 mtr. Below ground level for earth electrode conductor, including soldering etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 25 Supply and fixing of LED lamp 9 WATTenergy saving Complete all respect 26 Providing and fixing sleek and decorative strip type fixture with domestic electronic ballast and colored engineering plastic end plates, suitable for 28 watt FTL (T5), complete with all accessoris (excluding the T-8 tube), connections, testing and commissioning etc. as required. 1x 28 watt-FTL (T5) (Category-A with in all leads and lifts as per direction of the Engineer-in-Charge. 27 Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.Ceiling Fan 1200 mm sweep Category-A 28 Providing, Installation, testing Exhaust fanof following size in the existing opening , i/c making the hole to suit the size of the above fan, makinggood the damagesconnectiontesting and commissioning etc. as required. Exhaust Fan light duty (Domestic ) 225 mm sweep. 29 Supplying and fixing Ding-Dong/Electronic musical bell, suitable for D.C./A.C. single phase, 230 volts complete as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 30 Providing and fixingof stationary storage type electric water heater (Geyser) of various sizes by means of expansion -bolt with nuts and washers . i/c embedding of expansion -bolt in the wall , providing and fixing of Non -return valve ,Dead weight safety valve 2No C.P. connection rods 18 long making good the damages , electrical connection , safety valve connectiontestingtesting and commissioning etc. as required 5 lters cap. water heater (Cat -A) 31 Supplying and fixing ceiling rose on the existingjunction box / wooden blockincluding connections etc. as required. 32 Supplying and fixing Solar street lights are raised light sources which arepowed by solar panels generally mounted on the lighting structure or integatedinto the pole itself . The solar panels charge a rechargeable batterywhich powers a fluorescentof LED lamp during the night with in all leads and lifts as per direction of the Engineer-in-e.