}

Tender For Providing Repair And Maintenance Of Electrical Appliances And Wiring In Infosys Foundation Red Cross Sarai At P.G.I.M.E.R Campus, At Sector-12, U.T. Chandigarh., Chandigarh-Chandigarh

Chandigarh Administration Engineering Department has published Tender For Providing Repair And Maintenance Of Electrical Appliances And Wiring In Infosys Foundation Red Cross Sarai At P.G.I.M.E.R Campus, At Sector-12, U.T. Chandigarh.. Submission Date for this Tender is 09-09-2025. Electrical Products Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

50757830
Corrigendum : Tender For Providing Repair And Maintenance Of Electrical Appliances And Wiring In Infosys Foundation Red Cross Sarai At P.G.I.M.E.R Campus, At Sector-12, U.T. Chandigarh.
Tender
Indian
Chandigarh
Chandigarh
09-09-2025

Tender Details

Providing Repair And Maintenance Of Electrical Appliances And Wiring In Infosys Foundation Red Cross Sarai At P.G.I.M.E.R Campus, At Sector-12, U.T. Chandigarh.- 1 DSR Item No. 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2 Single pole 3 Double pole 4 Triple pole and neutral 5 DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holesin cubicle panel, making connections, etc. as required. 6 100 A,30KA,FPMCCB 7 DSR Item No.1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 8 1 x 1.5 Sq.mm 9 3 x 1.5 Sq.mm 10 3 x 2.5 sq. mm 11 3 x 4 sq. mm 12 DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 13 DSR 1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 14 6 Module 15 8 Module 16 12 Module 17 DSR ITEM NO.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 18 25 mm 19 DSR Item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 20 5/6 A switch 21 3 pin 5/6 amp. socket 22 15/16 A switch 23 6 pin 15/16 amp. socket 24 DSR 2.2 Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply,earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 25 DSR 1.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flickerfree (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/cconnections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved byEngineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)18- 22 watt 26 Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. 27 Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD300-6-1)/ Bajaj make (Supreme DLX)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only. 28 Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP)/ Crompton (EXHD380-6-1)/ Bajaj (Supreme DLX)/Orient (Industrial Heavy Duty)/ Usha (Turbo HEDF900RPM) make only. 29 DSR 1.16 LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltageprotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135lm/Watt output . LM79 & LM80 Test report from NABL lab for all testingrequired for LED fixtures as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).250 watt 30 DSR 1.13 LED Street light fixture, powder coated pressure die castaluminum body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LEDfixture powder coated pressure die cast aluminum body with driver asper the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMCAs per CISPR 15 , lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).90 watt 31 S/E of 400 amp. 415 volt 4 pole change over switch with MS enclosure. The change over switch should be of Havells/ L&T/ Schneider/ ABB/ Hagar make only. The change over switch should be installed in existing cubical panel/ angle iron board including drilling holes in cubical panel angle iron board making incoming and outgoing connection with suitable rating of copper wire, copper strip etc as required. The job includes cost of labour and other petty material required to complete the job to the entire satisfaction of Engineer-in-charge of work.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-09-2025 Tender Extend2 Date 04-09-2025
2 04-09-2025 Tender Extend3 Date 09-09-2025
3 27-08-2025 Tender Extend1 Date 01-09-2025

Key Value

Document Fees
Refer document
Tender Value
INR 4.87 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail