}

Tender For Addn/ Altn For Roof Treatment And Connected B/R Wks In Offrs Md Accn At Middle Shankar Vihar And Other Certain Minor Works In The Area Of Age B/R-Ii Of Ge (South) Delhi Cantt-10, delhi-Delhi

Military Engineer Services has published Tender For Addn/ Altn For Roof Treatment And Connected B/R Wks In Offrs Md Accn At Middle Shankar Vihar And Other Certain Minor Works In The Area Of Age B/R-Ii Of Ge (South) Delhi Cantt-10. Submission Date for this Tender is 09-09-2025. Shed Construction Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

50746672
Tender For Addn/ Altn For Roof Treatment And Connected B/R Wks In Offrs Md Accn At Middle Shankar Vihar And Other Certain Minor Works In The Area Of Age B/R-Ii Of Ge (South) Delhi Cantt-10
Tender
Indian
Delhi
Delhi
09-09-2025

Tender Details

Tender For Addn/ Altn For Roof Treatment And Connected B/R Wks In Offrs Md Accn At Middle Shankar Vihar And Other Certain Minor Works In The Area Of Age B/R-Ii Of Ge (South) Delhi Cantt-10; 1 Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition (Parapet wall) complete all as specified and as directed. 2 Demolition of Brickwork built in cement mortar including all quioins, arches, pillars etc complete all as specified and as directed. 3 Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and as directed. 4 M & L for demolition of mud in roof, any thickness, including plastering and leeping upto four storey bldg incl necessary scaffolding arrangement and removing from cantonment area or as directed complete all as directed. 5 M&L forCement concrete type B-0, 1:2:4 (12.5mm graded aggregate)as inroof padding, finished even and smooth without using extra cement ,includingcleaningthe concrete surface by steel wire brushes, up to four stories bldgs, complete all as speified and as directed. 6 M&L for complete surface treatment and insulation system over concrete roof surface, including the following operations, complete all as specified and directed by Engineer-in-Charge:a) Cleaning of existing roof surface using wire brush and air blower to remove dust, debris, and loose particles. Cutting open existing cracks in V-groove and sealing with polyurethane sealant or polymer-modified mortar. Repairing unsound surfaces using SBR-based bonding agent and polymer-modified mortar. Where required, filling horizontal depressions using free-flowing micro-concrete.b) Applying single-component, solvent-based, moisture-cured polyurethane resin primer low viscous and high penetrative — using brush/roller at minimum 200 ml/sq.m (adjustable as per porosity). Primer to be mixed uniformly using electric stirrer.c) Applying two coats of single-component, non-UV-resistant polyurethane waterproofing membrane over the primed surface at intervals of 4–6 hours. A 60 GSM non-woven geotextile fabric shall be embedded between coats.Minimum total consumption: 1.8 kg/sq.m, achieving 1.2 mm average dry film thickness (DFT).Membrane performance requirements:• Tensile strength ≥ 1.8 N/mm²• Elongation ≥ 650% (ASTM D412)• Shore A Hardness ≥ 45 (ASTM D2240)• Crack bridging ≥ 1.5 mm at -9°C (ASTM C836)• Solid content ≥ 90%• Complies with ASTM C836 and ASTM C898 7 d) Roof insulation using spray-applied Polyurethane Foam (PUF), applied with a two-component (Polyol and Isocyanate) system, achieving 80 mm average thickness, with closed-cell rigid foam (density: 45–50 kg/m³). Application to be done in layers over a surface with <5% moisture using mechanical spray foam equipment.PUF specifications:• Conforms to IS:12432 Part 3• Thermal conductivity ≤ 0.023 W/m·K @ 25°C (ASTM C518)• U-Value ≤ 0.33 W/m²K (ECBC)• Tensile strength ≥ 400 kPa (ASTM D1623)• Compressive strength ≥ 300 kPa (ASTM D1623)• Closed cell content 96–98% (ASTM D2856)• Fire resistance: Class B2 (DIN 4102)e) Laying 150 GSM non-woven polyester geotextile as a separation/protection layer over PUF, laid loose with minimum 75 mm overlap at all joints.f) Application of high-SRI coating system, comprising:• One coat of self-priming coat (diluted 40% with potable water)• Two coats of PU-modified fiber-reinforced elastomeric membrane• All coats to be applied using brush/roller/spray at 4–6 hour intervalsMinimum total consumption: 1.2 kg/sq.m 8 Performance criteria:• Crack bridging ≥ 1.5 mm• SRI value ≥ 106Note:1. The rate quoted shall be inclusive of all labour, materials, tools and plants, scaffolding, masking/protection of adjacent surfaces, cleaning, consumables, testing, and workmanship. All work shall be carried out strictly as per manufacturer’s specifications and to the satisfaction of the Engineer-in-Charge.2. Water Proofing Treatment shall be carried out by authorized applicator of manufacturer.3. Product and his technical specification as per BoQ item shall be submitted by Contractor to Accepting Officer for his approval.4. MoU between Authorized applicator and contracor shall be sumitted before commencement of Roof treatment Work.5. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment and2.5% of work done amount for srl item No 6.00 or Rs 5000/- which is more shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work or in lieu, contractor may deposit FDR issued from bank for the said amount for 10 years, which shall be released by GE on expiry of satisfactory completion of 10 years period.Make : SIKA/Berger/Asian Paints/STP/Fosroc 9 M & L for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and as directed. 10 Dismantling wrought iron or mild steel/cast iron work of any description (steel window & Grill)complete all as specified and directed. 11 M & L for Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars, window frames, barred iron doors, ladders,framed balusters,walk ways, railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165 complete all as specified and as directed. 12 M & L for preparation of new Steel surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified. 13 M & L for 15 mm bore GI tubing medium grade with all fittings fixed to wall or floor including taking up or down steel tubing and connections 15 mm bore complete all as specified and as directed. 14 All as per srl item No 14.00 here-in-before but 20 mm bore. 15 All as per srl item No 14.00 here-in-before but 25 mm bore. 16 S&F 500 ltr capacity rotational moulded triple layered polyethylene water storage tanks (cylindrical vertical with closed top) white colour hoisted and fixed in position including dismantling of water tanks exceeding 250 ltr capacity but not exceeding 500 ltr complete all as specified and as directed. 17 S&F 1000 ltr capacity rotational moulded triple layered polyethylene water storage tanks (cylindrical vertical with closed top) white colour hoisted and fixed in position including dismantling of water tanks exceeding 500 ltr capacity but not exceeding 1000 ltr complete all as specified and as directed. 18 S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and as directed. 19 S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm bore complete all as specified and as directed. 20 S&F 110 mm uPVC pipes Type A (for rain water), single socketed, in any length with rubber ring joints, fixed to walls including taking down eaves gutters and rain water pipes (any size, material or pattern), including all fittings , heads, shoes, bends,swann necks, etc including taking out of trenches if required for cleaning or refixing or removal to store complete all as specified and as directed. 21 S&F 110 mm uPVC (SWR) Bends/ Tees/ Tapers (any radius), with or without oval access door as required complete all as specified and directed. 22 S & F Stack clamps out of 50 mm x 5 mm flat iron and 6mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for any bore and any type of pipes complete. 23 Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etcincluding removal of debrish from the MOD land complete all as specified and as directed. 24 M & L for rendering 15 mm thick with ready mix mortar other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. 25 M&L for complete removal of existing treatment under (OBD/Oil paint/ white wash etc)by scrapping with mechanical wall sander on wall/ceiling (having mechanical vacuum mechanism) having RPM not less than 1500, sending pad of 80 grit having dia of 7/9to make the surface free from dust, loose paint , removal of nails etc and filling cracks/ holes and windows /doors jams by putty & repairs in good shape by skilled labour complete all as specified and as directed. 26 M&L for waterproof cement based putty of average thickness1-2 mm over the plastered/Old painted wall /ceiling surcafes to make the surface free from dust etc, by skilled labor as per following steps :-Step 1 :-Mix the putty powder by adding water as per manufacturer instructions and mix it with wall mixture with the mixing capacity of minimum 2.5 kg putty per minute Step 2 :-Applying the first coat of prepared mixture with the help of fully automatic airless spray machine of putty application having flow speed of maximum 6 liters per minute with a maximum pressure of 3300 PSI.Step 3 :- Allow 6-8 Hrs time to dry the putty surface. 27 M&L for applying two coat of super quality weather proof exterior emulsion paint over and including one coat of primer using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 m the spray machine should be of reputed manufacturer with Pro guard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and as directed. 28 Excavation in post holes in hard / dense soils , each not exceeding 0.50 cum, getting out, returning filling in and ramming earth in layers not exceeding 25 cm including watering & removing surplus soil to a distance notexc. 50m & making good surface complete all as specified and as directed 29 M&L for cement concrete (1:4:8) Type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. 30 Cutting holes in brick walls in built in cement mortar or cement lime mortar exc half brick but not exc one brick complete alll as specified and as directed. 31 Cutting chases ,pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges or landings, steps, cills, sunshades,shelves,lintel,etc and cutting in chases for concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth complete alll as specified and as directed. 32 M&L for mild steel work in tubular trusses including special shaped washer, cleats etc complete using ERW or induction butt welded tubes confirming to IS: 1161-1979 grade st - 240 complete all as specified and as directed. 33 S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 34 M&L for 100 mm thick cement concrete (1:4:8) Type D-2, (40 mm graded crushed stone aggregate), as in sub-base of floor and similar works complete all as specified and as directed. 35 M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in holdfasts, coping on edges etc including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and as directed. 36 M&L for 60 mm thick factory made, M-35 grade machine pressed precast concrete interlocking paver block of any colour, any shape and size confirming to IS 15658-2006, laid over and including 50 mm laid sand cusioning complete all as specified and as directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail