}

Tender For Provision Of Weather Shed Near Testing Hall, Misc Br Works And Tensile Entrance For Admin Building At 5 Afsb Under Ge (Af) Borjhar., borjhar-Assam

Military Engineer Services has published Tender For Provision Of Weather Shed Near Testing Hall, Misc Br Works And Tensile Entrance For Admin Building At 5 Afsb Under Ge (Af) Borjhar.. Submission Date for this Tender is 09-09-2025. Shed Construction Tenders in borjhar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

50746641
Tender For Provision Of Weather Shed Near Testing Hall, Misc Br Works And Tensile Entrance For Admin Building At 5 Afsb Under Ge (Af) Borjhar.
Tender
Indian
Assam
Borjhar
09-09-2025

Tender Details

Tender For Provision Of Weather Shed Near Testing Hall, Misc Br Works And Tensile Entrance For Admin Building At 5 Afsb Under Ge (Af) Borjhar.; 1 Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) unreinforced of any description,complete all as specified & directed. 2 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ Loose soil. 3 M & L for PCC 1:2:4 type B2 using 40 mm graded stone aggregate as in foundation complete all as specified & directed by Engr-in-Charge. 4 S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.of I. S.1161-1979 grade St.-240 complete all as specified & directed by Engr-in-Charge. 5 M & L for MS plates, plain or chequered, cut to shape, hole drilled & welding with connected members complete all as specified & directed by Engr-in-Charge. 6 M & L for two coats of synthetic enamel painting over a coat of red oxide primer to iron & steel surfaces exe 10 cm width & girth incl preparation of surface complete all as specified & directed by Engr-in-Charge. 7 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed by Engr-in-Charge. 8 S&F 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet colour having tensile strengthof 550Mpaas in roof covering/ cladding to wall, fixed with self tapping screws and bituminous washers as in roof complete all as specified & directed by Engr-in-Charge. 9 S&F 0.50 mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet colour having tensile strengthof 550Mpaas in roof covering / ridging/ cladding/ valley gutters/eaves gutter to wall, fixed with self tapping screws and bituminous washers as in roof complete all as specified & directed by Engr-in-Charge. 10 S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to steel post incl all accessories with 110mm bore complete all as specified & directed by Engr-in-Charge. 11 S&F PVC (SWR) bends of any radius 110mm bore complete all as specified & directed by Engr-in-Charge. 12 S&F Bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required: hooks (stay), heavy for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks forhanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed by Engr-in-Charge. 13 S&F Stop ends (for spigot or socket ends) or nozzles of 100mm dia complete all as specified & directed by Engr-in-Charge. 14 S&F Drop ends (for spigot or socket ends) or nozzles of 100mm dia complete all as specified & directed by Engr-in-Charge. 15 Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50 mtr and making good surface in soft/ loose soil. 16 M&L for PCC 1:3:6 type C-2 (40mm grade aggregate) in foundation filling and mass concrete etc complete. 17 S&F for MS work angle iron as in fencing post, struts incl cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mess) incl all necessary drilling bolting or reveting etc and similar work conforming to Fe-290 Gde E-165etc complete. 18 Supply only for mild steel TMT bars as in straining bars of size 10mm dia etc complete all as specified and directed. 19 S&F of MS flat iron, round or square bars conforming to Grade E-165 (Fe- 290) for fixing chain link fencing, all as directed. 20 S&F for mild steel screw bolts,purpose made with hexagonal or square head at one end and screwed the other end or each screwed end to be fitted with washers and one hexagonal or square nut dia exc 5cm but not exc 10mm, dia meter of the neck 9 in 11to 15mm all as specified and directed. 21 S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed. 22 Supply only mild steel galvanised chain link fencing of size or type complete all as specified and as directed by Engineer-in-charge. 23 Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, bars etc. including provision of binding wire compete all as specified and as directed. 24 M&L for Brick work with sub class B bricks using old size bricks straight or curved on plan on any radious in half brick thick wall built in CM (1:4) etc complete all as specified and directed. 25 M&L for 15mm thick rendering CM 1:4 on other than fair faces of brick or concrete surfaces of external walls finished even and fair complete all as specified and directed. 26 M&L for PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as infoundation and mass concrete complete all as specified & directed. 27 Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete 28 M&L two coats of cement based paint on plastered surfaces in preparation of surfaces on walls complete all as specified and directed. 29 M & L for RCC 1:2:4 Type B 1 using 20 mm aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. 30 M & L for RCC 1:2:4 Type B1 using 20 mm aggregate as inprecast cover slab and set in CM (1:4) 31 M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) 32 M & L for Brick work with sub class B bricks using old size bricks, exe 6 mtr mean radious, built in CM 1:6 complete all as specified and directed. 33 M & L for RCC Nominal mix (1:2:4) type B1 using 20mm graded stone aggregate for concrete as in Lintel beam complete all as specified and directed. 34 M & L for Formwork to sides& soffit of lintel beam etc flat fair finished surface complete all as specified and directed. 35 M & L for Steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. 36 All as per Serial item 35.00 here in above but 8 to 10 mm dia as in stirrups, binders etc 37 M & L for Rendering 15 mm thick on fair faces of brick worksurfaces in CM (1:4) as in external plastering, in two layers (10 + 5) top coat of 5 mm to be mixed with WPC@ 3% of cement, finished even and smooth without using extra cement 38 Supply only Integral water proofing compound. 39 M & L for Rendering 10 mm thick on other than fair faces of brick worksurfaces in CM (1:6) as in internal plastering, finished even & smooth without using extra cement complete all as specified and directed. 40 M & L for preparing thenew plasterd surface of external wall & applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. 41 M & L providing and applying plaster of paris putty average 1.0 mm thicknesss over plastered surfaces and prepare the surface even and smooth complete all as specified and directed. 42 M & L forpreparing the new plasterd surface of Internal wall & applying two coats of Oil bound distemper to walls with distemper, white or tinted including chalk whitening on plastered surfaces of wallls complete all as specified and directed. 43 S & F pressed steel door frame of size 105X65mm with one or more rebates including all necessary fixture lugs, hinges, lock strike plate complete all as specified and directed. 44 S & F 35mm thick flush shutter solid core construction with block board core and plywood faced panels, commercial type on both sides complete all as specified and directed. 45 S & F 150mm aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 46 S & F 125mm aluminium anodised handles cast type complete all as specified and directed. 47 S & F 100mm long medium weight cold rolled mild steel butt hinges complete all as specified and directed. 48 S & F Supply and fixing factory made uPVC white colour Two track two panels sliding window upto 1.50 m height made of (big series) frame 67 x 50 mm & sash bar of 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsizefor fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware’s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately). 49 Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 50 S & F 4.00mm thick ordinary sheet glass in squares exc 0.5 sqm each pane complete all as specified and directed. 51 M & L for two coats of synthetic enamel paint over a coat of pink primer to wooden surfaces over 10cm width or girth including preparation of new surfaces complete all as specified and directed. 52 S & F for Mild steel rag or lewis bolts screwed one end with hexagonal or square nut and washer and other end enlarged and jagged or lewised exc 15cm and not exc 30cm long, Dia of bolt 12 mm complete all as specified and directed. 53 M & L for RCC 1:2:4 (Nominal mix) type B1 20mm graded aggregate concrete in foundation including rafts, footings, basement/ bottom slabs and mass concretecomplete all as specified and directed. 54 Use and Waste for Formwork to sides of concrete foundations raft sides and soffits (if any) of foundation and similar work including flat fair finished surface complete as specified and as directed. 55 Supply and Fixing of Pre fabricated cantilever tensil structure made with750 to 850 GSM blackout fabric sheet (Special fabric) with tensile strength(wrap/weft) of 3500/3500 N/cm and tear strength (wrap/weft) of 450/400 N including MS super structure hollow tube column (139x3.60mm),Outer frame pipe & Arch pipe truss section of M.S hollow tube (76x3)mm,MS base plate (350x350x12)mm,MS purlin pipe (48x3)mm inlcuding foundation bolts and aluminium flat bar of (25x3)mm thick ,SS fittings grade 304 and all MS fixture required as per struturalbasic technical specificationrecommended by the Consultant/ Manufacturer complete all specified and directed by Engg-in-charge. 56 Note: (i) The area of canopy of fabric only to be measured for payment purpose. The other structural members required for supporting of the fabric all as per manufacturers instructions shall deemed to be included in the quoted same rate.(ii) The foundation care shall be measured andpaid separatelyMake of Fabric : Sioen/ Serge ferrari of fabric or as per make approved by E-in-Cs Branch. 57 Surface dressing not exceeding 15 cm deep as in soft / loose soil. 58 M & L for bringing approved earth from outside MD land forming embankment including raising earth, spreading in layer not exc 30cm thick, watering, ramming/rolling and finished to required gradient, size and shape etc, not exc 1.50mtr from the base complete all as specified and as directed. Note: (i) Payment shall be made for solid quantity arrived after consolidation. (optimum moisture contact with 95% proctor density to be achieved) (ii) Before execution of this earth shall be tested /checked for suitability to use. 59 M&L for hardcore of broken stone or boulder of gauge not exceeding 63mmdeposited spread and levelled in layers not exceeding 15mm thick, watered and rammed to a true surface as in sub base of floor complete all as specified and as directed. 60 M&L for 100mm thick PCC 1:3:6, Type C-2 using 40 mm graded stone aggregate as in sub base of hardstanding, complete allas specified and directed. 61 M & L for 75 mm thick PCC 1:2:4 Type B1 using 20 mm graded stone aggregateas in hard standing, finishing surface even and smooth without using extra cement, & making impression of expanded metal whilest the concrete is green, complete allas specified and directed. 62 M&L for rendering 15 mm thick in cement mortar (1:6) onfair face of brick work of walls, finished even & smooth without using extra cement complete all as directed. 63 Material and Labour for forming 20 mm thick expansion joints to full depth, filled with pre-form bituminous filler and top 30mm primed and sealed with sealing compound, grade A complete all as specified and as directed. 64 Forming contraction (Dummy)joints 65mm deep x 10 mm wide, filled with sealing compound grade A, complete all as specified and as directed. 65 Material and labour for Point wiring with 1.5 Sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable inand incl rigid PVC conduit concealed / PVC surface conduit with sunk cast iron/ pressed steel terminal boxes of adequate size with suitable thickness hylum laminated sheet, cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm (FRLSH) PVC insulated andunsheathed multi stranded copper conductor cable as earth wire (green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. 66 All as per serial item No 63.00 here in before but for one 3 pin 5 Amp socket outlet on independent board. 67 Supply and fixing of switch piano flush type 240 Volts 6 Amps, SP, one way complete all as specifed and directed. 68 Supply and fixing of switch socket outlet combination 2 in 1, 3 pin 6 Amps 240 volts flush type (non shuttered) complete all as specified and directed. 69 Material and labour for 100W Deluxe Fan Regulator with 5 step speed control ISI marked, complete all as specified and directed by Engr-in-charge 70 Material and labour for ceiling rose surface bakelite two to three terminal isolated body fixed on PVC round block, 6A, Pilot 2 Plate, complete all as specified and directed by Engr-in-charge 71 Supply and fixing of LED fitting 1x18watts including Tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5 cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. 72 Supply and fix in repairs of DB 4 way MCB SPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed. Make : Legrand / Indo asian / Havells or its equivalent in specified makes in CA. 73 Supply & fix in repair of MCBs single pole neutral (SPN) 6 to 32 Amps with 10 KA breaking capacity of C series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. 74 Supply & fix in repair of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of C series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. 75 M&L of sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area4.0 Sqmm drawing into and including PVC conduit pipe of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. 76 Make : KEI/Havells/Anchor/polycabNote : (i)Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. 77 Supply, Installation, Testing and Commissioning of 1200 mm sweep BEE 5 star rated BLDC ceiling Fan, ISI marked, power less than or equal to 28watt, Class of insulation: B, Safety Rope, 100% copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.00, Air delivery minimum 215 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, Blade Thickness : 1.08 mm , Electronic step regulator compatible for speed control, temperature rise 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC, Leakage Current 210 Micro Amp Max, Two Ball Bearings , Powdercoated, Surge Protection ( electronics ) upto 4 KV, Shall withstand 1.5 Kv, 50 Hz AC between current carrying and non-current carrying metal parts without any flash over for 1minute, Provision of Safety wire for additional safety of fan for falling down and all remaining accessories including safety pin, nut bolts, washers etc.Make : USHA / Havells/ Atomberg or as per make approved by E-in-Cs Branch. 78 M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanizediron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thickRCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced withsuitable handle and angle iron frameand necessary excavation and earth work in any type of soil etc. complete all asspecifiedand as directed includingtesting on completion. Note: The rate quoted shall inclusive of GI wire 4 mm dia with GI pipe protection 15 mm, light grade up to 7.5 m.

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
INR 43.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail