Tender For International Archives & Heritage Center,Tvm - General Electrical Work. - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 2 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 3 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 4 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 5 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 6 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 7 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 8 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 9 1.24.6Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 10 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 11 90.10.3.32Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator 12 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 13 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 14 1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 15 1.27.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) 16 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) 17 1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 18 OD93342/2025-2026Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 19 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 20 1.14.10Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire 21 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 22 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 23 1.14.9Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire 24 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 25 1.18.2Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 26 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 27 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 28 2.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door 29 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door 30 2.3.4Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door 31 90.11.1.10Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 32 90.11.1.11Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) 33 90.11.1.12Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) 34 90.11.1.14Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43) 35 90.11.1.16Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 36 90.11.1.20Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 37 OD93518/2025-2026Supplying & fixing DP / FP pole sheet steel enclosure on surface / recess for mounting MCB / Isolator complete with connections, testing & commissioning etc. as required. 38 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole 39 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Double pole 40 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Triple pole 41 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 42 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 43 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 44 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 45 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 46 2.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 47 90.14.10.21Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.400A, 70 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC 48 OD95139/2025-2026 Supplying and fixing 40-63A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 49 OD96472/2025-2026 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overload protection (RCBO), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 50 OD96473/2025-2026 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overload protection (RCBO), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 51 OD96474/2025-2026Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker with overload protection (RCBO), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 52 8.1.2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade offollowing size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 53 OD93589/2025-2026 Supply of 3 core 300 sq.mm HT XLPE UG armoured cable as per the standards. 54 10.4.4Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 55 10.5.4Supplying and making outdoor cable1 kit completewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductorcable of 11 KV grade as required :300 sq. mm 56 90.12.1.29Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 50 sq mm 57 90.12.7.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp 58 90.12.7.33Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm 59 90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm 60 90.12.7.36Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm 61 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 62 90.12.7.42Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 63 OD95188/2025-2026Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KVgrade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 64 90.12.7.2Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 65 90.12.7.28Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 66 90.12.7.30Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 67 90.12.7.41Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 68 OD96783/2025-2026 Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 69 OD96800/2025-2026Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 70 9.1.1Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.2 X 6 sq. mm (19mm) 71 9.1.2Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm) 72 9.1.21Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 35 sq. mm (32mm) 73 9.1.22Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 50 sq. mm (35mm) 74 9.1.23Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 70 sq. mm (38mm) 75 9.1.26Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 150 sq. mm (50mm) 76 9.1.27Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 185 sq. mm (57mm) 77 9.1.30Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 300 sq. mm (70mm) 78 9.1.32Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) 79 9.1.33Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) 80 9.1.34Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 25 sq. mm (28mm) 81 4.1.2Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 82 4.1.4Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 83 4.1.6Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness 84 4.26.Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness 85 4.3.2Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness 86 4.3.4Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness 87 90.12.10.3Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size 88 90.12.10.4Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size 89 90.12.12.13Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size 90 1.34Supplying and fixing brass batten/ angle holder including connection etc. as required. 91 1.41Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 92 90.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. 93 90.4.6Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan. 94 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 95 OD94872/2025-2026Supply, conveyance and Installation of IP 66/ IP 67 weather proof 250x200x105mm cable junction boxwith all accessories as required. 96 OD94873/2025-2026Supply of surface/suspended industrial 40W LED batten with reflector with extruded aluminium housing,HET/PC diffuser with minimum output of 5200 lumens & 130 lumen/watt, LED CRI>80, CCT 5700 (+/- 300K),L70 B50 75,000 burning hours with valid LM 80, photo biological safety report & LM 79 report, driver with p.f > 0.95 and THD < 10%, surge protection upto 3kV, input voltage range 140-300V conforming to SELV standards with all accessories as required. 97 OD94874/2025-2026Supply of recessed mounted 36 Watts LED 2x2 back litlight with CRCA housing, HET diffuser with minimumof 4320 lumens & 120 lumen/watt, LEDCRI>80, CCT 5700 (+/- 300K), L70 50,000 burninghours with valid LM 80, photo biological safety report & LM 79 report, driver withp.f > 0.95 and THD < 10%, surge protection upto 4kV, input voltage range 140- 300V conforming to SELV standards with all accessories as required. M.S frame shall be provided if required for POP / Gypsum ceiling. 98 OD94875/2025-2026Supply of IP 65 round surface mounted 10 Watts LED downlight with aluminum diecast powder coatedhousing, polycarbonate diffuser with minimum output of 1000 lumens & 100 lumen/watt, LED CRI>80, CCT5700 (+/- 300K), L70 50,000 burning hours with valid LM 80, photo biological safety report & LM 79 report, driver with p.f > 0.9 and THD < 10%, surge protection upto 2.5kV, input voltage range 150-270V conformingto SELV standards with all accessories as required 99 OD94876/2025-2026Supply of round surface mounted 9 Watts LED downlight with aluminum heatsink, polycarbonate diffuser with minimum output of 1080 lumens & 120 lumen/watt, LED CRI>80, CCT 5700 (+/- 300K), L7050,000 burning hours with valid LM 80, photobiological safety report & LM 79 report, driver with p.f > 0.9 and THD < 10%, surge protection upto 2.5kV,input voltage range 100-265V conforming to SELV standards with all accessories as required. 100 OD94877/2025-2026Supply of recessed 15 Watts LED round backlit down light with Aluminium housing with minimum output of 1800 lumens & 120 lumen/watt, , HEP diffuser, LED CRI>80, CCT 4000 (+/- 300K), L70 50,000 burning hours with valid LM 80, photo biological safety report &LM 79 report, driver with p.f > 0.9 and THD < 10% conforming to SELV standards with all accessories as required 101 OD94878/2025-2026Supply of Surface mounted IP 65 10W LED bulkhead with minimum output of 1000 lumens & 100 lumen/watt with high pressure die cast aluminium polycarbonate diffuser, LED CRI>80, CCT 5700 (+/- 300K), L7050,000 burning hours, driver with p.f > 0.95 and THD < 10% conforming to SELV standards with all accessories as required.single core cable and earthing etc. as required. 102 OD94879/2025-2026Supply of Surface mounted 2 feet 10Watts LED linear light with extruded aluminum housing, with minimumoutput of 1000 lumens & 100 lumen/watt, LED CRI>80, CCT 5000-6000, L70 50,000 burning hours, driver with p.f > 0.9 THD < 10% conforming to SELV standards with all accessories as required.Wires/Cables shall be terminated properly as per the standards. 103 OD94880/2025-2026Supply of Surface mounted 4 feet 20Watts LED linear light with extruded aluminum housing, with minimumoutput of 2000 lumens & 100 lumen/watt, LED CRI>80, CCT 5000-6000, L70 50,000 burning hours,driver with p.f > 0.9 THD < 10% conforming to SELV standards with all accessories as required.Wires/Cables shall be terminated properly as per the standards. 104 OD94881/2025-2026Supply and installation of 9/10W B22 LED lamp with 90 lumen/watt in existing holder with all otheraccessories etc. as required 105 OD94882/2025-2026Supply of 400 mm sweep Wall fan working on 230V single phase A/C and other fixing accessories etc.complete as required 106 OD94883/2025-2026Supply of 225 mm sweep Light Duty Exhaust fan in metal frame working on 230V single phase A/C and other fixing accessories etc. complete as required 107 OD94861/2025-2026Supply and Installation of 100A TPN isolator (cubicle type) in suitable enclosure with all accessories asrequired. 108 Supply and Installation of 63A TPN isolator (cubicle type) in suitable enclosure with all accessories asrequired 109 OD94863/2025-2026Supply, installation, testing and commissioning of 250A FP Automatic transfer switch in suitableenclosure, interconnections etc complete and as required. 110 OD94864/2025-202Supply, erection, commissioning of additional length of exhaust M.S B-class pipes with long radius bend fromresidential silencer with necessary clamps, fixtures, civil works and painted with heat resistant to a maximum of 20m in stages with suitable sizes including suitable rain gaurd for top. Fixing shall be done with proper clamps, expansion bolts, support angle of suitable size fixed on the wall inside the duct as instructed by the Engineer. 111 OD94866/2025-2026Installation, Testing & Commissioning of 160kVA DG set complete with CPCB approved acoustic enclosureresidential silencer etc as per requirements from Statutory Authorities namely KSEB/Electrical Inspectorate and all relevant standards. The rate shall include the first filling of required diesel for the DG set or as per the requirement. 112 OD94867/2025-2026Supply of 160kVA (CPCBIV+ compliant) diesel generator set comprising of diesel engine, 6 cylinders /in-line with CRDI pump, radiator/water cooled turbo charged after cooled with a base mounted integral fueltank, 12V/130Ah battery with leads & terminal connectors, along with standard control panel with 4P MCCB (with UV & OL protections), panel mounted 12V DC SMPS battery charger, digital energy meter, rated capacity CTs, digital EFR, electronic genset controller, remote monitorig system, exhaust gas emission processed through DOC+SCD+ASC after treatment system, suitably optimized to meet stringent noise & smoke emission standards as laid down by MoEF / CPCBIV+ engine coupled wit AC alternator in IP23 protection, single bearing, self excited, self regulated through AVR & acoustic enclosure fabricated out of CRCA sheet steel after 7 tank process surfacepretreated with foam material as per CPCB norms - Sound level - 75dB (A) at one meter from enclosure surface in free field conditions with all accessories as required. 113 OD94868/2025-2026Supply, installation & testing of TOD meter, testing & re-installation of CTs & PTs (From USS) with allaccessories as required at TMR and obtain certificate as per the standards. 114 OD94869/2025-2026Supply and erection of Emergency push button station in suitable enclosure and giving neccesaryconnections. 115 OD94870/2025-2026Installation, testing and commissioning of 200 KVA Unitised substation with HT load break switch, drycast resin transformer, cable end termination facility etc complete. as follows. This includes thetransportation of U.S.S from the yard to the transformer room mounting, levelling etc.complete 116 OD94871/2025-2026Supply of 200kVA indoor USS, 11kV/433V 3phase, vector DYN-11 transformer with off circuit tappingsfrom +5% to -10% in steps of 2.5% changeable on off circuit by tap links provided with WTI & LV terminalssuitable for PVCA cable, Neutral CT, Earth fault relay, HV terminals connected to 11KV, 26.3kA, 630A load break switch with incoming suitable for XLPE cable with HT HRC fuses, CTs, PT, provision for fixing TOD meter and output connected to 11kV seal off bushingsto the transformer. It should be ECBC compiant 117 OD94849/2025-2026 MSB 118 OD94848/2025-2026 APFC Panel 119 OD94847/2025-2026Supply, conveyance, erection, testing and commissioning of cubicle type, dust and vermin proof,floor mounted, front operated MV panel board (Form 3B or above) confirming IS/IEC 61439 standards,made out of 16 SWG thick CRCA sheet, powder coated after 7 tank process, fully compartmentalised complete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel with all accessories etc as per the latest requirement of local authority complete with all connections and interconnections for the following panels. 120 OD94846/2025-2026Common panel -conveyance, erection, testing andcommissioning of cubicle type, dust and vermin proof,floor mounted, front operated MV panel board (Form 3B or above) confirming IS/IEC 61439 standards,made out of 16 SWG thick CRCA sheet, powder coated after 7 tank process, fully compartmentalisedcomplete with hinges and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel with all accessories etc as per the latest requirement of local authority complete with all connections and interconnections for the following panels. 121 5.14Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 122 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 123 90.16.1.4 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 124 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 125 90.16.5.4Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 126 OD94844/2025-2026Earthing with G.I. earth plate 1200 mm X 1200 mm X 12 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 127 6.12Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 128 6.14Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required. 129 6.2Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 130 6.7Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 131 6.8Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 132 5.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required 133 7.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 134 2.21Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 135 OD94838/2025-2026Supply and Providing of first aid box with sterile adhesive bandages, cotton, band- aids, anti-septic,lubricant, soap etc. as required 136 OD94839/2025-2026 Providing suitable rubber gloves as per the standards 137 OD94840/2025-2026Supply and Providing First Aid Chart duty framed and placed in a conspicious location for clear vision. 138 OD94841/2025-2026 Supply and Providing 1 No of 9 Litre capacity GI Fire Bucket painted in post office red with primer coat ofred oxide and written with white paint FIRE mounted on MS angle frame work/wall bracket filled with finesand, painting the bracket/ floor stand including making good the damages,colour washing etc. asrequired. 139 OD94842/2025-2026 Supply and Providing 2.00 mm thick, 3.3kV, Synthetic elastrometric fire retardant insulating sheet as per IS15652 standards. 140 OD94843/2025-2026 Supply and Providing 6kg ABC Type fire extinguisher with hose and clamps including fitting it to wall asrequired 141 OD94836/2025-2026 Approval & Sanction - Preparation of all drawings, computing the actual connected load, submitting the work completion report, obtaining power allocation & power connection fromKSEB.along with approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energisation certificates from Electrical Inspectorate & commissioning the installation in the premises. The rate shall include the charge for preparation of SLD, laminating and displaying it in designated area. The Transformer, DG, panels shall be ordered after getting the scheme approval. All statutory payments will be reimbursed on production of the original receipts. 142 Connection charges - KSEB 143 Extra Charges Provision for GST