Tender For Repair And Replacement Of Certain Electric Wiring Fitting And Fixtures In Otm Accn At Raiwala Mil Stn; 1 Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit,medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade(Color coding of wires shall be Phase-Red, neutral-Black and earth-Green wire all as specified ) galvanised sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including whitecover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. 2 All as per above item No.1but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed. 3 All as per above item No 1 but for One 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed . 4 All as per above item No.1 but controlled by two, two wayswitch5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed . 5 All as per above item No.1abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed . 6 All as per above item No.1 above but for existing concealed conduit inside wall, ceilingetc(light, fan, call bell) complete all as specified and directed . 7 All as per above item No.1but for existing concealed conduit inside wall, ceilingetcbut for One 3pin/5pin 5/6 Amps socket out let on same board with other switches, with cables 1.5 sq mm size,complete all as specified and directed . 8 All as per above item No.1 but for existing concealed conduit inside wall, ceilingetcbut forOne 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed . 9 All as per above item No.1 but for existing concealed conduit inside wall, ceilingetc but controlled by two, two wayswitch5/6 Amps. With cables 1.5 sq mm size complete all as specified and directed . 10 All as per Item No 1 abovebut for existing concealed conduit inside wall, ceilingetc with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed . 11 Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLSH PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLSH PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed .(a)All as per above item No.11for One light/fan/exhaust fan point controlled by 1 No,one way 5/6 Amp switch. 12 (b) All as per above item No.11 for One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. 13 (c) All as per above item No.11 for One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. 14 Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLSH PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLSH PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed . 15 S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzall as specified and directed by Engr-in-Charge. 16 Supply and fixing switch modular , one-way 16Amps,1 module 240 Volts ACall as specified and directed by Engr-in-Charge. 17 Supply and fixModular Socket outlet, 6A - 3 pin, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge. 18 Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module230 volts, 50 hz all as specified and directed by Engr-in-Charge. 19 Supply and fixing switch modular typesingle pole, two way 6 Amp, 1 moduleISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge. 20 Supply and fixing bell push modulartype single pole one way 6 Amps, 1 module with with indicator, ISI marked all as specified. 21 Supply and fixing step socket type modular fan regulator 120/280 V, 100 W, 2 module with 5 Steps, all as specified. 22 Supply and fixing bell ding dong AC 230/240 volts single pole , all as specified. 23 Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals all as specified 24 Supply and fixing in repair decorative wall light fixture made up of Polycarbonate with including one no. 9 W LED lamp with B22 base and complete all as specified and directed by engineer-in-charge.Make-Havells Cat Part No-LHFOFTE1TZ1W012(Apple) or equivalent in Philips/Crompton/Bajaj 25 Supply and fix in repairs /replacement switch piano 230 volts, AC, flush typesingle pole, one way 5/6 Amps ISI marked all as specified and directed. 26 Supply and fixin repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way-ditto-. 27 Supply and fix in repairs/replacement, socket out let3 pin 5/6 Ampsflush type 28 Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC all as specified and directed of ISI marked 29 Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed. 30 Suupply and fixing in repair step socket type fan regulator 120/280 V , ISI marked all as specified and directed by Engr-in-Charge. 31 Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .Make- legrand / ABB/ Schnider/L&T/Siemens 32 Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar. all as specified and directed .Make- legrand / ABB /Schnider/L&T/Siemens 33 Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V AC 4 way with 200 Amps rated bus bar. all as specified and directed . 34 Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified and directed . 35 S&F MCB’s single pole and neutral, 10 KA, 32 Amp to 40 Amp 240 Volts,and of C series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996,including taking down old one complete all as directed. 36 S&F MCB’s single pole, 10 KA ,6 Amp to 32 Amp 240 Volts,and of B series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996, including taking down old one complete all as directed. 37 Supply and fixing MCB TPN/ FP 63 Amp to 100 Amp, 415 V AC C series 10 KA rupturingwith required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996, including taking down old one complete all as directed. 38 Supply and fixing single pole and neutral enclosure modular type with a two pole and earth plug socket complete with one, single pole MCB 20 Amps 10 KA rupturingcapacity 240 Volts AC all as specified. 39 Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portionall as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. 40 Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit or more medium grade surface/ concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected withmain earth dolly including cutting chasing and making good disturbed portionall as specified and as directed .Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. 41 Supply and fixing sub main wiring four single core 4 Sqmm PVC insulated unsheathed stranded copper conductor cable (FRLSH) 1100 volts graded drawn in for three phase and one for netural & including rigid PVC conduit 25 mm dia or more medium grade concealed in wall as per existing along with 4. Sqmm PVC insulated unsheathed copper conductor cable (FRLSH) as earth wire connected with main earth dolly including cutting chassing and making good disturbed portion all as specified and directd. Note: Four runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. 42 Material and labour for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/ 2 way- 8 way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulatrs etc including white cover plate complete and connect existing circuit wiring with new switches &testing complete all as specified and directed.Note:- 1 payment will be done for each module as per rates quoted by the contractor 2.switch /sockets /regulators will be paid seperately. 43 Dismantling and taking down U/Spoint wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder,etc including CI/Pressed steel terminals, switch box excluding conduit when in wiring in existing conduit, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. 44 Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc excluding conduit when in wiring in existing conduit complete all as specified & as directed. 45 Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified 46 Supply and fix in repair/replacement new surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output with lumen efficiency >100 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed. Make Havells Cat No LHEXACP7IN1W010 Pride Plus Neo Batten or equivalent in Philips/Bajaj etc 47 Supply and fix in repair/replacment new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 65 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, and LED lumen efficiency > 140 lumen per watt, CCT should be between 5700° K- 6500 K including fixing on new bracket including making necessary electricconnection with 1.5 sqmm , 3 core, PVC insulated copperonductor cable 1100 Volt grade complete all as specified and as directed by Eng-in-Charge .Make Havells Cat No LHETAVU7PA7J020 or equivalent in Philips/Bajaj etc 48 S & F in replacement fresh air exhaust fan AC single phase 230/240 Volt of size 300 mm sweep, metallic body powder coated painted finish, Power consumption- 50 W, Air displacement -1290 Cum/Hr, RPM-900 complete with louvers including making whole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed .Make: Havells/Bajaj/Crompton 49 S & F in replacement ventilation air exhaust fan AC single phase 230/240 Volt of size 250 mm sweep,non-metallic high quality engineering plastic, air delivery 680 cmm Power consumption- 36 W, RPM-1200 complete with louversand two years warranty including making hole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed.Make: Havells/Bajaj/Crompton 50 S & F in replacement ventilation air exhaust fan AC single phase 230/240 Volt of size 300 mm sweep,non-metallic high quality engineering plastic, air delivery 680 cmm Power consumption- 36 W, RPM-1200 complete with louversand two years warranty including making hole and grouting of nut bolts etc and making good the disturbed surfaces of wallcomplete all as specified and directed.Make: Havells/Bajaj/Crompton 51 M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directedNote - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items.