Tender For Addn/Altn To Gis Classrooms At Afs Tambaram (8843/E8); 1 Dismantling floor hearth or wall tiling including cement mortor bedding (but not backing) removing the rubbish of the premises complete all as specified and directed by Engineer-in-Charge. 2 Demolition of cement concrete unreinforced floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge. 3 M&L 25mm thicknessplain cement concrete type B-0, 1:2:4 Nominal mix (using 12.5mm graded stone aggregate), as in levelling course of floors etc including formwork complete all as specified and directed by Engineer-in-Charge. 4 M & L glazed ceramic coloured tiles of size 450x300x7 mm thick on vertical surface as in dados, skirting etc, set and jointed in neat cement slurry over and including 10mm thick plaster in cement mortar 1:4, pointed with white/ coloured cement to match complete all as specified and directed by Engineer-in-Charge. 5 M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular )in floors ,area of each tile exc 0.11 sqm but n.exc. 0.18 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, over and including 15 mm thick screed plaster in CM 1:6 complete all as specified and directed by Engineer-in-Charge. 6 M&L Joint free Non skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a coat of Screed bedor bedding layer of mortar 15mm th for laying floor finish in CM 1:4 complete all as specified and directed by Engineer-in-Charge. Make: HR Johnson/Kajaria/Somany 7 M&L Light shade Vitrified ceramic tiles 9 to 10 mm thick (square / rectangular) area of each tile not exceeding 0.36 sqm butin floors set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles over a coat of Screed bedor bedding layer of mortar 15mm th for laying floor finish in CM 1:4 complete all as specified and directed by Engineer-in-Charge.Make: HR Johnson/Kajaria/Somany. 8 All as per item No 7 above but in vertical surface over a coat of rendering 10 mm thick on brick/ concrete surfaces with cement mortar 1:3 as backing coat complete all as specified and directed by Engineer-in-Charge.Make: HR Johnson/Kajaria/Somany 9 Taking down old cement plaster including racking out joint hacking for keys and scrubbing down with water etc., on wall surfaces complete all as specified and directed by Engineer-in-Charge. 10 M&L for rendering 10mm thick in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. 11 M&L for Rendering 15 mm thick inCM 1:4mixed with WPC at the rate as per manufactures instructions complete all as specified and directed by Engineer-in-Charge.Note: WPC shall be measured and paid separately under relevant item 12 Supply only Liquid water proofing compound 13 M&L Rendering 5mm thick in CM 1:3 on as in ceiling of fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. 14 M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of cement based paint complete all as specified and directed by Engineer-in-Charge. 15 M&L for preparation of newly plastered surfaces and applying two coats of Oil Bound Distemper over a coat of alkali resistance primer on wall complete all as specified and directed by Engineer-in-Charge. 16 M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling/ facia complete all as specified and directed by Engineer-in-Charge. 17 Demolition of stone slab of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge. 18 M&L 18 to 20mm thick granite slab (of any type) machine cut bedded jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, grinding & Polishing of type white marble including making holes for provision of gas pipe for LPG cylinder complete all as specified and directed by Engineer-in-Charge. 19 Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and directed by Engineer-in-Charge. 20 Demolition of brick work built in CM including all quoins arches pillars etc complete all as specified and directed by Engineer-in-Charge. 21 M&L fly ash Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. 22 S&F In repair viterous china water closet pedestal pattern with P or S trap including connection to flush and water pipe etc complete all as specified and directed by Engineer-in-Charge.Make : Jaquar/ Parryware/ CERA/ Hindware. 23 Supply only Seat Cover for EWCWhite flat bottom solid with CP hinging device, nuts & bolts etc complete all as specified and directed by Engineer-in-Charge.Make : Jaquar/ Parryware/ CERA/ Hindware 24 Supply and fixing only in repair PVC valveless, syphonic action type, flushing cistern of 10litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed by Engineer-in-Charge.Make : Jaquar/ Parryware/ CERA/ Hindware 25 S & F in repairs ABS body health faucet mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including accessories complete all as specified and directed by Engineer-in-Charge. 26 S&F in repair Vitreous China Wash basin, white, under counter fixing type, size 550 x400mm including coupling excluding taps, chain and plug and porcelain stopper and fixing on existingbrackets complete all as specified and directed by Engineer-in-Charge. 27 S/F in repairs PVCconnections 15mm dia 600mm long (for cold/hot water connection with brass or PTMT flynuts and washer at both ends complete all as specified and directed by Engineer-in-Charge. 28 S&F for angular two way stop cock 15 mm bore chromium plated with crtuch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union fixed as in repairs complete all as specified and directed by Engineer-in-Charge. 29 S&F in repairs 600mmx450mmx5mm thick mirror of selected quality glass mounted on 6mm thick AC Sheet and fixed to wooden plugs aluminium channelframe of suitable size complete all as specified and directed by Engineer-in-Charge. 30 S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge. Make : Jaquar/ SOMA/ Leader/ Zoloto/ Parryware/ Prayag. 31 S&F in repairs rotational moulded polyethylene water storage tanks ISI marked (cylindrical vertical with closed top) hoisted & fixed in position including all fittings and fixtures 1000litres Capacity including including dismantling old water tank and remove from site of height not less than G+1 bldg complete all as specified and directed by Engineer-in-Charge. 32 Taking down GIsteel tubing and connections, 15mm bore including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. 33 Taking down GIsteel tubing and connections, 20 bore including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. 34 Taking down GIsteel tubing and connections, 25 bore including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. 35 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and directed by Engineer-in-Charge. 36 S&F 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.Make : Finolex/ Deutron/ SFMC 37 All as per item No.36 but outer diameter of the pipe is 25 mm complete all as specified and directed by Engineer-in-Charge.Make : Finolex/ Deutron/ SFMC 38 All as per item No.36 but outer diameter of the pipe is 50 mm complete all as specified and directed by Engineer-in-Charge.Make : Finolex/ Deutron/ SFMC 39 Supply and fixed in repairs 15mm bore bib taps,cast copper alloy, with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.Make:Jaquar or Equivalent 40 S&F in repair 15mm bore cast copper alloy chromium plated angle cock with long shank & cup concealed type complete all as specified and directed by Engineer-in-Charge.Make:Jaquar / Soma/ Cera 41 Supply and Fixed in repairs 15mm bore Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure , screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.Make:Jaquar/Soma/ Cera 42 Supply and fixed in repairs 15mm bore Pillar taps, cast copper alloy, with capstan heads,chromium plqated, fancy type, screwed down high pressure, with or without lettered `Hot or `Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.Make:Jaquar/ Soma/Cera 43 Supply and Fixed in repairbrass chromium plated tublar towel rail 20mm dia and 60 cm long including brass chromium plated brackets of type D long between flanges complete all as specified and directed by Engineer-in-Charge. 44 S&F in repair Soap dish, vitreous China white, approximate size 160 x 160 x 90mm , fixed to plugs with chromium plated brass screws on walls complete all as specified and directed by Engineer-in-Charge. Make : Jaquar/ Parryware/ CERA/ Hindware 45 M&L forVitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) including urinal spreader complete all as specified and directed by Engineer-in-Charge. 46 S&F in repairs Bottle trap of PTMT having minimum water seal of 25mm ( min weight of 260gms) for 32mm bore complete all as specified and directed by Engineer-in-Charge. 47 Dismantling cast iron pipes/PVC pipes of any dia and any description including all fittings complete all as specified and directed by Engineer-in-Charge. 48 M & L for UPVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, fixed to walls/trenches,complete all as specified and directed by Engineer-in-Charge. 49 M & L for UPVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, fixed to walls/trenches,complete all as specified and directed by Engineer-in-Charge. 50 M & L for UPVC (SWR) pipes 50mm single socketed, in any length with rubber ring joints, fixed to trenches/walls,complete all as specified and directed by Engineer-in-Charge. 51 M & L for UPVC (SWR) bends 110 mmany radius, complete all as specified and directed by Engineer-in-Charge. 52 M & L for UPVC (SWR) bends75mmany radius,complete all as specified and directed by Engineer-in-Charge. 53 M & L for UPVC (SWR) bends50mmany radius,complete all as specified and directed by Engineer-in-Charge. 54 Taking down chowkhats or frame with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each and removal from site, complete all as specified and directed by Engineer-in-Charge. 55 Taking down chowkhats or frame with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4 Sqm each and removal from site,complete all as specified and directed by Engineer-in-Charge. 56 Taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm each and removal from site complete all as specified and directed by Engineer-in-Charge. 57 S&F for Powder coatedforaluminium Powder coated frame (thickness not less than 50 microns) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge. 58 S&F for Powder coated aluminium door shutters (thickness not less than 50 microns), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, key & locking system, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge.Note : Glass and wirecloth shall be measured and paid separately. 59 S&F for Powder coated aluminium window and ventilator shutters (thickness not less than 50 microns), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle complete all as specified and directed by Engineer-in-Charge.Note : Glass and wirecloth shall be measured and paid separately. 60 S&F in repair aluminium powder coated grills (pattern DG-104) weight of 2.00 to 3.20 Kg/Sqm for windows, ventilators, etc including jointing, cleats etc and fixed with medium screws into walls / frame work etc complete all as specified and directed by Engineer-in-Charge. 61 S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge. 62 S&F Wood Free EPS Factory made solid PVC Moulded flush door shutter 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm thick plain colour prelaminated PVC sheet on back face supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge. 63 S&F MS butt hinges medium weight 100mm long complete all as specified and directed by Engineer-in-Charge. 64 S&F Extruded Aluminium alloy handle fabricated type, anodised of size 100mm complete all as specified and directed by Engineer-in-Charge. 65 S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm complete all as specified and directed by Engineer-in-Charge. 66 S&F in repairs floor door stopper 140 mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring in floors complete all as specified and directed by Engineer-in-Charge. 67 Hacking out old broken glass from metal frame of any thickness incl punching or drilling out old glazing pin/springs clips and providing and fixingnew ones, complete all as specified and directed by Engineer-in-Charge. 68 S&F sheet glass 4mm thick ordinary quality & glazing with oil putty in square n.exc 0.5 Sqm in each paneat any height and any storey complete all as specified and directed by Engineer-in-Charge. 69 S&F in repair for stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with galvanised wire staples complete all as specified and directed by Engineer-in-Charge. 70 M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer-in-Charge. 71 Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets,complete all as specified and directed by Engineer-in-Charge. 72 S&FAnodised aluminium snap grid frame work for false ceiling all as specified Size of grid 605 x 605mm complete all as specified and directed by Engineer-in-Charge. 73 S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engineer-in-Charge. 74 S&F 12 mmPerforated particle board/tiles for insulation and accoustic purposes,600x600 mm in size, fixedwith nails to timberframework or with staple on snap grid timber/GI/Aluminium framework with screws complete all as specified and directed by Engineer-in-Charge. 75 M&L for complete removal of existing treatment of wall, including Washing, rubbing down and stopping of distempered and painted surfaces of pilasters, including cornices and applying two coats of Oil Bound Distemper over a coat of alkali resistance primer and 1mm plaster of paris wall care putty including preparation of surfaces complete all as specified and directed by Engineer-in-Charge. 76 M&L preparation of old surfaces area and applying one coat of white wash on ceiling complete all as specified and directed by Engineer-in-Charge. 77 M&L for complete removal of existing finish and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of old steel or iron surfaces exc 10 cm width or girth,complete all as specified and directed by Engineer-in-Charge. 78 Supply and fixing Hollow PVC sheet wall lining (paneling) consisting of 5mm thick wood grain printed PVC hollow sheet fixed as per manufacturers specifications and as directed) complete all as specified and directed by Engineer-in-Charge.Make:M/s Rajshree plastic wood/ M/s SMP Magma or Equivalent as approved by GE 79 S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and drawing complete all as specified and directed by Engineer-in-Charge. 80 S & F in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall bend to shape, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 81 S & F in repair Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. 82 Material and labour for providing and applying HS TPO membrane of 1.2mm thick over the layer of 200 gsm Geo-Textile with overlap joints of 75mm in both longitudinal and transverse direction of the TPO and sealed properly with hot air welding and terminate TPO at the top of parapet wall with termination strip and fix it by screw at 300mm c/c and sealed with HS jointeal PU on top including surface preparation like remove all loose gravels, dirt, oil, grease and other foreign particles by jet or dry air and clean the surface mechanically or by grinding to make it smooth before application and PCC / cementitious coving of 75mm radius shall be provided at all junctions between vertical and horizontal faces before application of TPO completely as per specification and direction complete all as specified and directed by Engineer-in-Charge.Note :- The work shall need to be carried out through authorised applicator of OEM/ Membrane manufacturer company.Contractor shall submit 10years guarantee bond with security deposit as specified in Particular specification of the CA and also Company back guarantee shall be be handed over by contractor after completion of water proofing work to the department for payment. Pipes over roof shall be realigned as per requirement. 83 M&L for applying two coats of Acrylic based cementitious water proofing paint over one coat of primer complete as per manufacturers instructions and complete all as specified and directed by Engineer In Charge. 84 S&F Self Adhesive water proofing flash bond membrane 100mm wide of make:Bostiq India fixed to joints of AC / Ridge portion / over surfaces of galvalume roof sheets / concrete surfaces etc up to 30m height incl necessary scaffolding and removal of the same after completion of the job complete all as specified and directed by Engineer In Charge. 85 Taking down sub main wiring any description along with PVC conduit/Casing & capping/wooden batten/metal conduit and made good the disturbed surface complete all as specified and directed by Engineer-in-Charge. 86 Taking down unserviceable DB/metal clad boxes any description or size/way including MCCB/MCBs complete all as specified and directed by Engineer-in-Charge. 87 Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store for Servicable one for reuse& unserviceable one for BER process complete all as specified and directed by Engineer-in-Charge. 88 Hanging/Refixing only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge. 89 Taking down Exhaust fan, ceiling rose, dismantling blades and removing fan and blades to store for Servicable one for reuse& unserviceable.one for BER process complete all as specified and directed by Engineer-in-Charge. 90 Refixing only Exhaust fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge. 91 M & L for painting of ceiling fan/exhaust fanany sweep, complete in situ with one coat of synthetic enamel paint by spraying with spray gun including filling cavities with filler, cleaning all dust etc including writing MES NO complete all as specified and directed by Engineer-in-Charge. 92 Taking down old aluminium point wiring (light, fan, socket or power) complete fittings such as switches,sockets,ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-Charge. 93 M/L for point wiring concealed type for One light point controlled by one switch with 1.5 sqmm PVC FRLS insulated,un-sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigidPVC rigid conduit not less than 20 mm dia with its accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision ofsuitable 1.6 mm thick MS pressed steel terminal boxes concealed suitable to modular sockets/switches including modular cover frame and plate in wall for housing of modular switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. 94 All as per item No.93 but for One light point controlled by Two switch 95 All as per item No.93 but for One fan point controlled by one switch 96 All as per item No.93 but for One socket point on Independent board 97 All as per item No.93 but for One socket point on same board with other switches 98 All as per item No.93 but for One call bell point controlled by one bell push 99 All as per item No 93 above but with 2.5 sqmm for power point 15 amps complete all as specified and directed by Engineer-in-Charge. 100 All as per item No 93 above but with 4.0 sqmm for AC point socket outlet 15 amps complete all as specified and directed by Engineer-in-Charge. 101 S&F Modular Switch flush type, 6 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge. 102 S&F Modular switchflush type 6 Amps, Single Pole Two way complete all as specified and directed by Engineer-in-Charge. 103 S&F Modular Switch flush type, 16 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge. 104 S&F Modular Bell push 6 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge. 105 S&F Ceiling rose surface PVC insulatedthree plates JUMBO type 240 volts complete all as specified and directed by Engineer-in-Charge. 106 S&F Modular socket outlet 2/3 pin 6 amps 240 volts flush type. Two module complete all as specified and directed by Engineer-in-Charge. 107 S&F Modular socket out let 6/16 Amp 6pin flush type Two module complete all as specified and directed by Engineer-in-Charge. 108 S&F Modular Fan regulator electronic type with 5 step control suitable for 1200/1400 mm ceiling fan complete all as specified and directed by Engineer-in-Charge. 109 S&F Call bell 230 volts single pole A/C fancy type multi music type bell and including taking out unserviceable old bell complete all as specified and directed by Engineer-in-Charge. 110 S&F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driverwith 22 W LED (4 ft) lampincluding disconecting, removing,and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.( Make: Havells/ Bajaj/ Philips) 111 S&F LED lights fitting 1x 22W, 220V, Suspended architectural LED luminare provides soft-light and glare free symmetrical illumination with (continuous mounting end cap connecting up with three core flexible copper conductor including disconecting, removing and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. ( Make: Havells/ Bajaj/Philips) 112 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.Make: Havells/ Bajaj/Philips 113 S&F in replacement of Mirror light fitting LED luminares New generation energy savingIP65 Mirror light luminaire with opal diffuserwith 10W LED including disconecting, removing,and connecting into electric circuit and testingcomplete all as specified and directed by Engineer-in-Charge.( Make: Havells/ Bajaj/Philips) 114 S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light sourcewith 35W LED 5000K lampincluding disconecting, removing,and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. Make: Havells/ Bajaj/Philips 115 M&L for GI Bracket bend to shape in cold or hot 40mm bore, ISI marked, medium grade and 1.50m long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unserviceable GI bracket complete all as specified and directed by Engineer-in-Charge. 116 Cutting chases, pinning in making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings steps, chills, sunshades, shelves, lintels etc and cutting chases for concealed conduit wiring etc. and making good cutting exceeding 10cm but not exceeding 20cmgirth complete all as specified and directed by Engineer-in-Charge. 117 M&L for sub main wiring two run of 4 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. 118 M&L for sub main wiring two run of 6 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. 119 M&L for sub main wiring four run of 10 sqmm single core PVC insulated unsheathed cablesingle core multistranded FRLS copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 10 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge. 120 S&F Single pole and neutral enclosure with a two pin and earth plug and socket for AC complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. 121 Refixing of Single pole and neutral enclosure with a two pin and earth plug and socket for AC complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. 122 Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 8 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. 123 Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN12 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. 124 Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door typeincluding 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge. 125 S & F MCB 6-32/40 amps,breaking capacity 10 KA , SP 240V complete all as specified and directed by Engineer-in-Charge. 126 S & F MCBs B curve SPN 6-32/40 Amps, breaking capacity 10 KA , 240V complete all as specified and directed by Engineer-in-Charge. 127 Supply and fixing for Isolator Triple Pole63Amps, 10KA 240volts,50Hz complete all as specified and directed by Engineer-in-Charge. 128 Supply and fixceiling fans 1200 mm sweep, energy saving BLDC, 230 V AC 50 HZ complete with down rodincluding necessary wire connection from ceiling rose complete all as specified and directed by Engineer-in-Charge. 129 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including necessary connection from ceiling rose complete all as specified and directed by Engineer-in-Charge. 130 Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4.0 mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work.PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and directed by Engineer-in-Charge. 131 M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4.0 mm thick for inter connecting of earth electrodes complete all as specified and directed by Engineer-in-Charge. 132 S&F PVC non metallic rigid conduit not less than 20 mm dia with itsconduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge. 133 M&L Ceiling fan hook made out of MS bar 10 mm dia bar bend to shape or anchor fastener with hook for shifting/hanging ceiling fans complete all as specified and directed by Engineer-in-Charge. 134 Refixing of LED/CFL light fittings any type including replacing the necessary connections complete all as specified and directed by Engineer-in-Charge.