}

Tender For Creation Of Psychiatrist Therapy Room Including Electrical Work, bilaspur-Himachal Pradesh

All India Institute Of Medical Sciences has published Tender For Creation Of Psychiatrist Therapy Room Including Electrical Work. Submission Date for this Tender is 25-08-2025. Building Work Tenders in bilaspur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50725216
Tender For Creation Of Psychiatrist Therapy Room Including Electrical Work
Tender
Indian
Himachal Pradesh
Bilaspur
25-08-2025

Tender Details

Tender For Creation Of Psychiatrist Therapy Room Including Electrical Work; 1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 2 Cement mortar 1:6 (1 cement : 6 coarse sand) 3 12 mm cement plaster of mix : 4 1:4 (1 cement: 4 coarse sand) 5 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 6 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 7 With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. 8 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. 9 Two coats. 10 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 11 Hot finished welded type tubes 12 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 14 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 15 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and 1S: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 16 For fixed portion:Powder coated aluminium (minimum thickness of powder coating 50 micron) 17 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 18 Powder coated aluminium (minimum thickness of powder coating 50 micron) 19 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 20 125 mm 21 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2}), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 22 10 x 120 mm 23 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . 24 With float glass panes of 5 mm thickness (weight not less 25 Providing and fixing of the 4mm XLPE sheet with aluminium facing over the Wall surface with glue and sealed all over laping with weather resistant silicon after cleaning the Wall from dust and dirt undulations if any as per Direction of Engineer-In-Charge. 26 Providing and fixing of the 6mm Insureflector sheet both side aluminium facing over 4mm XLPE Sheet (Already Pasted) with glue and sealed all over laping with weather resistant silicon as per Direction of Engineer-In-Charge. 27 Providing and Fixing GI Grid system includes GI Stud having Size 48 mm X 36 mm X 34 mm X 0.50 mm, length 3600 mm, and Floor Channel Size 50 mm X 32 mm X 32 mm X 0.50 mm, length 3600mm is fastened vertically/ horizontally at every 600 mm centers with 50 mm Thick 1000 GSM Polyester Wadding infilled between the Frame work as per Direction of Engineer-In-Charge. 28 Providing and fixing 11 mm Sound Barrier Board( Composite Fibre Board with Black Sound Barrier Membrane) of Size 600x1200 mm Square Edge of Density 1500 Kg/m3 to be Installed on G.I Frame (Already Paid) as per Direction on Enigneer-In-Charge 29 Providing and Fixing Wooden Acoustical wall paneling Slats Up to 8ft Height made out of HDMR board Pre- laminated, perforated wooden grooved slats patterns 15-2/30-2/15- 3/28-4/60-4mm backline with black acoustical fleece having NRC value not less than 0.70, tongue-groove edge for a seamless look, Fire Resistance as Per BS:476 Part-7, Clause O, linear dimension size 128mm x 2440mm x 16mm thick having density more than 850 Kg /m3, weight 12.8Kgs/m2 installed by using GI strut system.. Aluminum core cross channel having thickness 0.80mm, length 3000 mm, web 15 mm and 25 mm, depth 19 mm and flanges of 7 mm Both Side is then fixed perpendicular to the GI Stud with the help of Metal Screw at every 600mm C/C infilled with 25 mm/800 GSM Polyester Wadding. Then wooden slats are tongue and grooved with the help of special design Z clip as per Drawing and Design. .(GI stud cost has been taken in Item No. 3). 30 Providing and fixing first class steam beech wood lipping/moulded beading or taj beading of size 70x50mm fixed with wooden adhesive of approved quality and screws/nail on external edges of stage .The work shall be executed as per drawings ,specifications & instructions of engineer in charge. 31 Providing and Fixing Fully Perforated Gypsum Plaster (PERFORNA-G) Board MAKE: GYPTECH/SAINT GOBAIN /ARMSTRONG of size 1200x1830x12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in- charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 32 Providing and fixing of 50mm thick thermal bonded non woven polyester wadding of 100GSM behind the perforated gypsum board . ( MAKE- Gyptech / Nowofill/Dupont) 33 Providing and fixing Rockwool Acoustical False Ceiling Tile (AKOSTIKA) WHITE FOR HALL AREA With Textured Paint & Anti-Fungal Coating at all heights of size 595mm X 595 mm X 20 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) > 85%, NRC 0.9, Confirm to Anti Bacterial Activity Test (JIS Z 2801: 2010) & Resistance to Fungal Attack As per ASTM: (G21-15) in true horizontal level paseted on gypsum board with rubber base adhesive .The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (MAKE:GYPTECH/ARMSTRONG/ECOPHON) 34 Providing and fixing 75 mm Thick Fire Cum Acoustical Door Finished with Laminated on Both side. Door shall be made in 2nd Class Teak/Sal Wood Frame in 45 X 75 mm. Door shutter shall have 8mm Commerical Ply Laminated on both side.Polyster Wool Insulation of 50mm/1000 nn GSM Density shall be kept between Wooden Frame. 6mm Thick Calcium Silicate Board of Ramco IndustriesLtd to fixed on Both Side of the Wooden Frame. Door Chouwkhat should be made of 125mm X 75mm of 2 nd ClassTeak/Sal Wood Dully Polished with 80 mm Patam. 100 mm Hinges 4 Nos. S.S handles 300- 350 mm Two Sets, 100 mm Tower Bolts ins, Door Stopper 1 nos and Lock Arrangement as required . (Make : Ozone, Godrej, Dorset or Equivalent) 35 Supply ofWonderfloor Heavy Duty Premium PVC Wooden Planks manufactured with multi-Layers technology. Highly suitable to handle heavy footfalls. This flooring is termite resistant, moisture resistance & fire resistant. TimberlandMaestro 3.0 mm thickness of size 152.4mm x 914.4mm as per EN 427 in wooden surface texture, high strength wear layer of 300 microns, having Density of 5.50/kg sqm. Dimentional Stability as per EN 434, Fire Rating as per EN 13501-1, Horizontal & VerticalBurning Test as per IS 15061-2002. Slip Resistance R9 as per DIN 51130, Abrasion Resistance as per EN 660-2 wear Group T. Suitable/Continuous use of Castor Chair as per EN 425,Sound Absorption 6db as per ISO 140-8/EN ISO 717-2. WonderGuard PUR surface protection for anti-stain and ease in maintenance , and skirting in approved design and shade , Complete all as per the instruction of the engineer in charge 36 Supplying & drawing Following sizes of FRLS PVC insulated copper conductor ,Single core cable in the existing/recessed steel/pvc conduit as required . 37 2x1.5 sq mm 38 3x4 sq mm 39 Supplying & Fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed condiut as required . 40 25 mm 41 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 42 Supplying and fixing modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required 43 5/6 A Switch 44 15/16 A Switch 45 3 Pin 5/6 A socket Outlet 46 6 pin 15/16 A Socket Outlet 47 Supplying & Fixing Folllowing Sizes/Modules .GI box alongwith modular base & cover plate for modular switches in recess ets. as required . 48 3 Module ( 100mmx75mm) 49 6 Module ( 200 mmx75mm) 50 LED Panellight 2x2ft., (System lumen efficacy>135 lm/Watt) Supplying, installation, Testing & Commissioning of Panellight 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC140270 Volt,freq50/60hz,Operatingtemprange-15degto40degcentigrade,internalsurge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED,Driver& electrical circuitry),of minimum50000 Burning Hours with , 70% of initial Lumenmaintained tilllife ends ,CCT 3000°K /4000°K /5700°K /6000°K/6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more thanthe specified rating and Fixture shall be of relevant BIS standard andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/Embossing/Screen printing on housing. completeinallrespecti/cconnectionswith 1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm) 51 36 watt 52 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU),surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU),copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation offollowing capacity with Scroll / rotary compressor. The system shall be ableto deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 yearOriginal Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 53 2.0 TR with 5 Star BEE Rating 54 Supplying and drawing of UTP 4 pair CAT 6 LANCable in the existing surface/recessed steel/PVC conduit as required 55 1 run of cable

Key Value

Document Fees
Refer document
EMD
INR 41840.0 /-
Tender Value
INR 20.92 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail