Bids Are Invited For Intelligent Multi-Criteria Detectors For Upgradation Of Fire Protection System - Intelligent Multi-Criteria Detectors For Upgradation Of Fire Protection System Specification Given In Ppe-00157/R0 Please Refer Section 3.1.2, 3.1.3 &3.1.5 Of The Ppe-00157/R0 , Manual Call Point For Upgradation Of Fire Protection System - Manual Call Point For Upgradation Of Fire Protection System Specification Given In Ppe-00157/R0 Please Refer Section 3.1.4 Of The Ppe-00157/R0 , Zone Monitoring Unit For Upgradation Of Fire Protection System - Zone Monitoring Unit For Upgradation Of Fire Protection System Specification Given In Ppe-00157/R0 Please Refer Section 3.1.7 Of The Ppe-00157/R0 , Monitor Module For Upgradation Of Fire Protection System - Monitor Module For Upgradation Of Fire Protection System Specification Given In Ppe-00157/R0 Please Refer Section 3.1.8 Of The Ppe-00157/R0 , Relay Module For Upgradation Of Fire Protection System - Relay Module For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Loop Powered Remote Hooters For Upgradation Of Fire Protection System - Loop Powered Remote Hooters For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Repeat Response Indicator For Upgradation Of Fire Protection System - Repeat Response Indicator For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Fas Control Panel Having 8 Loop Capacity With Redundant Cpu - Fas Control Panel Having 8 Loop Capacity With Redundant Cpu Complete With All Cards/Modules 96 Zones With Two Nos Of Ac To Dc Psu(One Along With Fau And Another Standalone Psu) Housed Inside A Seismically Qualified Electronic Cabinet & Capable Of Accepting 2Nos.Of 240V Ac 50 Hz Single Phase Input And 10 Nos. Of Relays For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Zone Indicating Panel For Upgradation Of Fire Protection System - Zone Indicating Panel For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Fire Alarm Control Panel Having 2 Loop Capacity With Single Controller - Fire Alarm Control Panel Having 2 Loop Capacity With Single Controller Complete With All Cards/Modules 96 Zones, With Two Nos Of Ac To Dc Psu (One Along With Fau And Another Standalone Psu) And Capable Of Accepting 2 Nos. Of 240Vac 50Hz Single Phase Input And 2Nos. Of Relays For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157 R0 , Lcps -Bare Cabinets For Upgradation Of Fire Protection System - Lcps (Bare Cabinets) For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Standalone Ac To Dc Psu-Smps For Lcps For Upgradation Of Fire Protection System - Standalone Ac To Dc Psu/Smps (For Lcps) For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Hand-Switches, Push Buttons, Indicating Lamps For Upgradation Of Fire Protection System - Hand-Switches Push Buttons, Indicating Lamps For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Loop Powered-Cpu Motherboard- Backplane- Bus Powered Relay Modules With At Least 8 Change Over Contacts For Upgradation Of Fire Protection System - Loop Powered/ (Cpu Motherboard/ Backplane) Bus Powered Relay Modules With At Least 8 Change Over Contacts For Upgradation Of Fire Protection System, Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Spares For Fas Control Panel Min. One Type Of Each Card Or 10 Percentage Whichever Is More Standalone Psu Etc. - Spares For Fas Control Panel (Min. One Type Of Each Card Or 10% Whichever Is More Standalone Psu Etc.) For Upgradation Of Fire Protection System,Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Spares For Relays Other Loose Components And Modules. For Upgradation Of Fire Protection System - Spares For Relays Other Loose Components And Modules. For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Test Meter For Smoke Detectors - Test Meter For Smoke Detectors Compatible With Supplied Smoke Detectors , Smoke Detector Removal Tool Kit With 6 M Collapsible-Concentric Rod - Smoke Detector Removal Tool Kit With 6 M Collapsible/Concentric Rod Compatible With Supplied Detectors , Smoke Detector Testing Tool Kit - Smoke Detector Testing Tool Kit Compatible With Supplied Smoke Detector , Aerosol Gas Cans 250 Ml - Aerosol Gas Cans 250 Ml For Testing Of Supplied Smoke Detectors , Heat Detector Tester - Heat Detector Tester Compatible With Supplied Detectors , 1 Pair 1.5Sq. Mm Overall Shielded Hrpvc Insulated Frls Pvc Sheathed Un-Armoured Cable For Upgradation Of Fire Protection System - 1 Pair 1.5Sq. Mm Overall Shielded Hrpvc Insulated Frls Pvc Sheathed Un-Armoured Cable For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , 5 Pair Individually Shielded 1.5Sq.Mm Hrpvc Insulated Frls Pvc Sheathed Unarmoured Cables For Upgradation Of Fire Protection System - 5 Pair Individually Shielded 1.5Sq.Mm Hrpvc Insulated Frls Pvc Sheathed Unarmoured Cables For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , 10 Pair Individually Shielded 1.5Sq.Mm Hrpvc Insulated Frls Pvc Sheathed Unarmoured Cables For Upgradation Of Fire Protection System - 10 Pair Individually Shielded 1.5Sq.Mm Hrpvc Insulated Frls Pvc Sheathed Unarmoured Cables For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , 19 Mm Flexible Gi Conduit For Upgradation Of Fire Protection System - 19 Mm Flexible Gi Conduit For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Supply Of 25 Mm Rigid Hot Dipped Gi Conduit Including Accessories - Supply Of 25 Mm Rigid Hot Dipped Gi Conduit Including Accessories Viz. Elbows,Inspection Bends, Couplers, Checknuts, Fasteners, Gaskets, Lead Rawal Plugs, Saddles, Spacers Etc. For Upgradation Of Fire Protection System, Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Supply Of Nickel Plated Double Compression Brass Cable Glands - Supply Of Nickel Plated Double Compression Brass Cable Glands(Nptor Metric Straight Thread) For Cables Being Supplied Against Item No.21 To 26 Above. For Upgradation Of Fire Protection System Overall Specification And System Requirement For This Product Is Specified In Ppe-00157/R0 , Other Accessories Mcbs Sealing Compound Etc - Other Accessories Mcbs Sealing Compound Etc. For Upgradation Of Fire Protection System , Installation And Commissioning Of The System For Upgradation Of Fire Protection System - Installation & Commissioning Of The System For Upgradation Of Fire Protection System, Overall Specification And System Requirement About Commissioning Is Specified In Ppe-00157/R0 Total Quantity : 15565