| 1 | Providing, laying, testingcommissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia |
| 2 | Providing, laying, testing& commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia |
| 3 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :80mm dia |
| 4 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150 mm dia |
| 5 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB |
| 6 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.150 Amp, 16KA,TPMCCB |
| 7 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 8 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 X 35 sq. mm (28mm) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 X 95 sq. mm (38mm) |
| 11 | Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 12 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 13 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness |
| 14 | Wiring for light point/ fan point/ exhaust fanpoint/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, withpiano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single corecable etc as required.Group C |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 16 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 17 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 18 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep |
| 19 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 250 mm X 60 mm deep |
| 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 22 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator8 way, Double door |
| 25 | Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 26 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 27 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 28 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thicksaddle) |
| 29 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 30 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 32 | Supplying and fixing PVC batten/ angle holder including connection etc. as required |
| 33 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 35 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 36 | \"SITC of Horizontal Centrifugal pump set with Non-clog solid handling impeller to handle storm/ mixed/ sewage water having minimum Discharge of 220 m3/hr at Head15Mtrs, RPM - 1450 RPM (ind.) having suction and delivery size(125mm and 100 mm dia. respectively) mounted on a common base frame coupled with Min. 25 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Packing: Gland Casing- CI, Impeller- CI, Shaft- 40C8 complete with tyre coupling, coupling guard and foundation bolts.\" |
| 37 | Supply installation testing and commissioning Horizontal centrifugal pump set with non clog /mf impeller to handle storm/mixed / sewage water with having min. discharge of 800 m3/hr at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia, mounted on a common base frame coupled with Min. 40 HP or suitable rating (IE-2) three phase, TEFC AC, 415 volts, 50 Hz supply electrical Motor energy efficient complete as required. Mounted on a common base frame as Casing CI, Impeller CI, Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd. |
| 38 | P & Fof M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:-350 mm(8 mm thick),length 0.75 m |
| 39 | P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete as required of following Dia.350 mm(25 mm thickness) |
| 40 | P & Fof M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia:-350 mm(25 mm thickness) |
| 41 | P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 with required nut bolts & packing sheet etc. complete as required of following Dia.- 350 mm, 9.5 mm thick |
| 42 | SITC of Horizontal type, self priming non clog sewage pump, single stage Pump, with CI Impeller, EN8 shaft & Sleeve, with suitable suction & Delivery LPM 1032 at 10 Mtr, Head up to 20 Mtr coupled with 3 phase 1 Induction motor 5 HP, TEFC, 440 Volt, 1450 RPM with coupling guard, Base frame with AVM etc complete as required |
| 43 | Providing & Fixing of MS Bar Screen made out of MS channel size 4\" x 2\" (100 mm x 50 mm) and center covered with MS Flat size 80 x 8 mm duly welded with center to center distance 40 mm and back side supporting channel (100 x 50 mm) duly welded. Work also includes complete Bar Screen fixing in the drain with the help of heavy crane and complete bar screen duly painted with enamel paint. Bar Screen duly fixed in side wall using Mortar, tools and tackles |
| 44 | Providing & Fixing of MS Bar Screenmade out of MS Angle size(75 mm x 75 mm) and center covered with MS Sq bar size 18 mm duly welded with center to center distance 35 mm andduly welded. Work also includes complete Bar Screen fixing in the drain with the help of heavy crane and complete bar screen duly painted with enamel paint. Bar Screen duly fixed in side wall using Mortar, tools and tackles. etc complete as required. |
| 45 | Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming toIS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 80mm |
| 46 | On load change over switch 630 Amp. Open execution type: 2 Nos. (one for DG set and 1 for phase sequence). |
| 47 | S/I/T/Cof cubical type control panel board for three phase star delta starter,three position selection with auto switch for Mono submersible pumping set of following rating complete with single phasing preventer in auto, contactor (25Amp), O/L relay TP, MCB, Voltmeter, ammeter, VSS and indication lamp etc. including lamp etc. including connection etc. as required. (a) 10 H.P. rating Submersible Pump Set Over Load relay (range13-21 Amp) & Contactor (range 25 Amp). |
| 48 | Supply of corrugated & chequered rubber mat for electrical purposes exceeding IS: 5424/ 69 Black or Red in 1 M X 2 M of size.25 mm thickness |
| 49 | Providing and fixing of 600 mm sweep Air circulator, complete with blades, jaal workable on 220/ 240 volts AC supply etc as reqd. |
| 50 | Providing & Fixing Auto transformer starter 50HP (without oil) conforming to ISS specification, tapping provided from 40, 60 & 80% of line voltage fitted with fix and moving contacts ETP grade copper to provide long life fitted with 3 magnetic overload relay of dash pot type adjustable from full load to twice of full load earthing terminal provided suitable for places where motor starting load is high etc. complete as required. |
| 51 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3C*35 sqmm |
| 52 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*95 sqmm |
| 53 | SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switch gears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP& N) |
| 54 | supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) |
| 55 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 56 | SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5%(b) Luminaire Efficacy >=100 Lm/w (c) Power Factor >;=0.95 (d) Protection Class- IP-66 |
| 57 | S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 |
| 58 | Providing & fixing of MS Platformmade out of MS Girder size 8” x 4” (200 x 100 mm) fixing in back sides and center supporting with MS angle iron size 50 x 50 x 6 mm with cross welding and fixing of MS chequred sheet of 7 mm thickness on top side of MS platform, back side of platform duly welded MS railing with 2” dia MS pipe with 3’ 6” height to be fixed at site. Complete plate and railing duly painted with enamel paints |
| 59 | Making, Supply and Fixing of Sluice Gate of size 1.5 Mtr. x 1.9 Mtr. height made fromM.S U Channel of size 100X50mm with making U guide in drain andmaking a rubberarrangement on both end vertically and both end horizontal at bottom side. The gate made from M.S Sheet of 10mm thick with size 1.5 Mtr. x 1.25 Mtr. The sheet should be me dined in both end with rubber to make a leak proof arrangement at both side and running of gate by S.S Spindle, thrust bearing, and G.M Nut with handle at top |
| 60 | Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming toIS 5312 (Part 1 & 2), PN 1.6 complete as required(a) NRV 150mm |
| 61 | Supply, Installation, Testing and Commissioning of AMF panel suitable for 125 KVA DG set with complete accessories as required. |
| 62 | Supply, Installation, Testing and Commissioning of 125 KVA rating Silent DG set CPCB IV+ comprising of engine coupled to alternator mounted on a common base frame along with green,other accessories i.e. Standard Control Panel, Panel, Fuel tank, Battery with leads. |
| 63 | SITC of APFC Panel duly compartmentalized wall mounted / floor mounted cubicle board made from 2mm thick CRCA sheet dust & vermin proof duly powder coated inclusive of suitable size of 4 strip AI. Busbar complete with interconnection providing lugs, inter-earthing, painting etc. i/c providing & fixing below noted accessories;. 1. Suitable Size of INCOMING four pole MCCB, 2. Suitable Size of Analog Ammeter with selector switch C.T. \"s etc.- 1 Set, 3. 500 Volt analog Voltmeter with selector switch - 1 set 4. RYB LED type Indication lamps with Backup fuses -1 Set of three., 5. Power factor meter - 1 set ,6. 14 step APFC relay with aux. Contactor and timer - 1 set., 7. Suitable capacity 4 strip AI. Bus- Bar., 8. Required numbers of OUT GOINGS with suitable sets & sizes of MCCB compatible to KVAR rating of APFC panel for overall maintaining of required P.F. and also confirming to safe running of complete panel etc., 9. Required set of Push button for START I STOP., 10. AUTO I MANUAL Selector switch - 1 No. Complete with all required accessories,connections, interconnection etc as required |